Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
coarse_zero_up | 401B | Coarse Zero Up | Coarse increase of the zero output | msrc_UNKNOWN | Details |
coarse_zero_down | 401C | Coarse Zero Down | Coarse decrease of the zero output | msrc_UNKNOWN | Details |
fine_zero_up | 401D | Fine Zero Up | Increase the zero output slightly. | msrc_UNKNOWN | Details |
Little_Endian | 401E | Little Endian | msrc_UNKNOWN | Details | |
fine_zero_down | 401F | Fine Zero Down | Decrease the zero output slightly. | msrc_UNKNOWN | Details |
save_zero_changes | 4020 | Save Zero Changes | This saves the value of the Zero potentiometer. If it is not saved, the Zero potentiometer will revert back to the last saved value when power is cycled. | msrc_UNKNOWN | Details |
fine_span_up | 4021 | Fine Span Up | Increase the span output slightly | msrc_UNKNOWN | Details |
fine_span_down | 4022 | Fine Span Down | Decrease the span output slightly | msrc_UNKNOWN | Details |
save_span_changes | 4023 | Save Span Changes | Save the span adjustment. If it is not saved, the Zero potentiometer will revert back to the last saved value when power is cycled. | msrc_UNKNOWN | Details |
restore | 4024 | Restore Factory Settings | This method will restore zero and span to factory set values | msrc_UNKNOWN | Details |
reset_msa | 4025 | Reset MSA Flag | This method will reset the More Status Available (MSA) Flag. | msrc_UNKNOWN | Details |
reset_cc | 4026 | Reset CC Flag | This method will reset the Configuration Changed (CC) flag. | msrc_UNKNOWN | Details |
span_caution | 4027 | Caution | A calibrated pressure source is required. Adjusting the span without a calibrated pressure source can cause inaccurate readings! | msrc_UNKNOWN | Details |
current_caution | 4028 | Caution | This current is for reference only. Do not trim or calibrate the unit based on this current reading always use an calibrated external current meter. | msrc_UNKNOWN | Details |
Read_4_Max_Pressure | 4029 | Read Peaks | Display the four peak pressures that the device has measured after it left the factory and how long the device had been on when the peak accured. Clicking OK or Abort will close this window. | msrc_UNKNOWN | Details |
readtimeon | 402A | Time On | This is the time, in hours, that the unit has been on since it left the manufacturing facility. Clicking either OK or Abort will close this window. | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Abbruch Rückk. zu normal | msrc_UNKNOWN | Details | |
warning_message | 1017 | Kreis auf Handbetrieb | msrc_UNKNOWN | Details | |
Name | ID | Label | Description | Type | Source |