名称 | ID | 标签 | 描述 | 类型 | 源代码 |
---|---|---|---|---|---|
LF600_self_test | 411E | Self test | Self test of conveter | msrc_UNKNOWN | 详细信息 |
LF600_loop_test | 411F | Fixed pls out | Fixed pulse test; Fixed pulse output. When you use fixed pulse output function, set digital output function to PULSE OUTPUT. | msrc_UNKNOWN | 详细信息 |
LF600_cnt_ctrl | 4120 | Cnt ctrl | Counter control; Counter START or STOP, RESET | msrc_UNKNOWN | 详细信息 |
static_flow_zero | 405B | Zero adj | Still water zero adjustment is possible only when the flow rate value is within the range of +/-1.25m/s. | msrc_UNKNOWN | 详细信息 |
flow_cal_0 | 4099 | Flow cal 0% | Using the converter's internal calibration circuit, 0% flow rate calibration can be performed. | msrc_UNKNOWN | 详细信息 |
flow_cal_50 | 40C1 | Flow cal 50% | Using the converter's internal calibration circuit, 50% flow rate calibration can be read. | msrc_UNKNOWN | 详细信息 |
flow_cal_100 | 409A | Flow cal 100% | Using the converter's internal calibration circuit, 100% flow rate calibration can be performed. | msrc_UNKNOWN | 详细信息 |
ex_curr_dsp | 409B | Exc curr dspl | You can monitor the exciting current value. | msrc_UNKNOWN | 详细信息 |
LF600_D_size | 4121 | Meter size | Meter size of detector | msrc_UNKNOWN | 详细信息 |
LF600_flange_types | 4122 | Flange type | msrc_UNKNOWN | 详细信息 | |
LF600_pass_word | 4123 | Password | The password function is provided to protest the settings and adjustment of the functions affecting the flow rate measurement. | msrc_UNKNOWN | 详细信息 |
limit_of_change | 405F | Limit of change | The rate-of-change limit is used to control sudden changes of the converter's flow rate signal output when excessive noise is contained in the flow rate signal. The rate-of-change limit (set in percent value to the span of measuring range) and control limit time (set in second) are used, and if the flow rate signal sampling value exceeds the rate-of-change limit value based on the previous average value of the flow rate signal, the converter rejects the sampling value and outputs the average value including the maximum value of the rate-of-change value. Rate-of-change limit 0 to 30% / 50ms (in increments of 0.1%) Control limit time 0 to 20s (in increments of 1s) | msrc_UNKNOWN | 详细信息 |
LF600_manual_zero | 4124 | Manual zero | Manual zero adjustment value can be set within the range equivalent to +/-1m/s (+/-10% of the maximum range 10m/s). | msrc_UNKNOWN | 详细信息 |
preset_counter | 4061 | Preset value | Preset count can be set within the range of 0 to 99999999. | msrc_UNKNOWN | 详细信息 |
LF600_alarm_set | 4125 | Alarm set1 | Setting of high alarm or low alarm, empty alarm | msrc_UNKNOWN | 详细信息 |
LF600_alarm_set2 | 4126 | Alarm set2 | Setting of high/high(HH) alarm or low/low(LL) alarm | msrc_UNKNOWN | 详细信息 |
alarm_upper_value | 4062 | High alarm | High limit of the flow rate, at which an alarm is generated, can be set as % value of the span flow rate of the set maximum range. High alarm values for flow rate can be set within the range of -10% to 110% (percentage to Range 1) in increments of 0.1%. | msrc_UNKNOWN | 详细信息 |
alarm_lower_value | 4063 | Low alarm | Low limit of the flow rate, at which an alarm is generated, can be set as % value of the span flow rate of the set maximum range. Low alarm values for flow rate can be set within the range of -10% to 110% (percentage to Range 1) in increments of 0.1%. | msrc_UNKNOWN | 详细信息 |
alarm_upper_value2 | 4127 | HH alarm | High/high limit of the flow rate, at which an alarm is generated, can be set as % value of the span flow rate of the set maximum range. High/high alarm values for flow rate can be set within the range of -10% to 110% (percentage to Range 1) in increments of 0.1%. | msrc_UNKNOWN | 详细信息 |
alarm_lower_value2 | 4128 | LL alarm | Low/low limit of the flow rate, at which an alarm is generated, can be set as % value of the span flow rate of the set maximum range. Low/low alarm values for flow rate can be set within the range of -10% to 110% (percentage to Range 1) in increments of 0.1%. | msrc_UNKNOWN | 详细信息 |
LF600_press_keypad_pre_warning | 4129 | 设置回路为手动 | msrc_UNKNOWN | 详细信息 | |
LF600_press_keypad_post_warning | 412A | 注意——回路可能被返回自动控制 | msrc_UNKNOWN | 详细信息 | |
LF600_multi_range_hysteresys | 412B | Range hys | Range hysteresis is the dead band used when multiple ranges are switched. You can set the hysteresis within the range of 0 to 25% in increments of 0.1%. | msrc_UNKNOWN | 详细信息 |
LF600_count_rate | 412C | Count rate | Count rate must be set so that the pulse output at 100% output is within the range below: 3.6 to 36000000 pulse/h (0.001 to 10000 pulse/s). | msrc_UNKNOWN | 详细信息 |
pulse_width | 4060 | Pulse width | The pulse width must be set to a value within the range of 0.3ms to 500ms. The pulse width must be set to 40% or less of the period of pulse frequency at 100% output. If the pulse width is set to 0, it will be automatically set to 40% of the period of pulse frequency at 100% output. In this case, the pulse width setting mode remains in the Manual mode. If the calculation result exceeds 100ms, it will be forcibly set to 100ms. | msrc_UNKNOWN | 详细信息 |
main_unit | 40C5 | Main unit | Display main unit - Main unit on LCD of converter. | msrc_UNKNOWN | 详细信息 |
sub_unit | 40C6 | Sub unit | Display sub unit - Sub unit on LCD of converter. | msrc_UNKNOWN | 详细信息 |
return_to_normal | 1016 | 中止返回正常 | msrc_UNKNOWN | 详细信息 | |
transmitter_loop_test | 1023 | 回路测试 | 回路测试——允许用户将选择的模拟量输出手动调节至选择的常数输出值。 | msrc_UNKNOWN | 详细信息 |
transmitter_dac_trim | 1024 | D/A修正 | 数字到模拟修正——允许对选择的模拟量输出进行标定,在模拟量输出的操作端点有外部参考。 | msrc_UNKNOWN | 详细信息 |