Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
read_charac_table_method | 40AB | Read user defined curve | msrc_UNKNOWN | Details | |
flow_graph_method | 4095 | Update Chart | Update Chart | msrc_UNKNOWN | Details |
reset_changed_flag | 40B3 | Reset Configuration Changed Flag | msrc_UNKNOWN | Details | |
init_read_events_method | 4809 | Read the newest events | msrc_UNKNOWN | Details | |
next_read_events_method | 480B | Read next 20 events | msrc_UNKNOWN | Details | |
previous_read_events_method | 480A | Read previous 20 events | msrc_UNKNOWN | Details | |
m_auto_calibration_method | 4044 | Start Automatic Calibration | Select which calibration to run: 1) Travel Calibration 2) Tuning 3) Travel Calibration and Tuning 4) | msrc_UNKNOWN | Details |
m_one_step_calibration_method | 4045 | Start One Point Calibration | Start one point calibration | msrc_UNKNOWN | Details |
cancel_any_calibration | 4C6F | msrc_UNKNOWN | Details | ||
modify_parameters_method | 4C70 | Modify Parameter Values | Modify any integer or floating point type parameter in the device. | msrc_UNKNOWN | Details |
read_selected_events_method | 480C | Events | List selected events one at a time. Listing starts always from the latest event. Press ENTER to view the next event or ABORT to quit. You can select from 6 different classes. | msrc_UNKNOWN | Details |
warn_event_read_end | 4D65 | msrc_UNKNOWN | Details | ||
set_predefined_curve_method | 4ACF | Init Table with Predefined Curves | Send one of the predefined flow modification curves to the device. You must set Modification Type to 'Custom Table' to use this curve. You can select 1) Linear Curve 2)1/25 Curve 3)Quick 1/25 Curve 4)1/33 Curve 5)Quick 1/33 Curve 6)1/50 Curve 7) Quick 1/50 Curve | msrc_UNKNOWN | Details |
edit_charac_table_method | 4AD0 | User Defined Curve | Edit flow modification table points one by one. You must set Modification Type to 'Custom Table' to use this curve. NOTE: You must go thru the whole list to update the table. | msrc_UNKNOWN | Details |
warn_about_updating | 4C71 | msrc_UNKNOWN | Details | ||
start_offline_tests_method | 4852 | Start Offline Tests | You can select which offline test to start. You can start tests with default parameters or change them if you wish. | msrc_UNKNOWN | Details |
cancel_test | 4C72 | msrc_UNKNOWN | Details | ||
lock_unlock_device | 1073 | Lock/Unlock Device | Lock/unlock local interface. Locking also prevents other master writing parameters via HART interface. | msrc_UNKNOWN | Details |
device_lock_status | 4C73 | Local User Interface Lock | Shows if device is locked and which master has locked it. | msrc_UNKNOWN | Details |
reset_counters_method | 4C74 | Reset Counters | Resets certain diagnostics counters. Be careful to use this command since you may lose very important data! | msrc_UNKNOWN | Details |
identify_nd9000_method | 4C75 | Identify Device | Device should show scrolling text 'DEVICE ACCESSED' on its display. | msrc_UNKNOWN | Details |
show_device_mode_method | 4C76 | Device Mode | Show the device mode (or modes). | msrc_UNKNOWN | Details |
show_device_status_method | 4C77 | Device Status | Shows alarm and error conditions reported by the device. | msrc_UNKNOWN | Details |
check_cut_offs_method | 4AD7 | msrc_UNKNOWN | Details | ||
check_split_range_method | 4AEF | msrc_UNKNOWN | Details | ||
check_setpoint_method | 4AD8 | msrc_UNKNOWN | Details | ||
check_supply_pressure | 4B17 | msrc_UNKNOWN | Details | ||
check_temperature_low | 4B18 | msrc_UNKNOWN | Details | ||
check_stiction_low | 4B15 | msrc_UNKNOWN | Details | ||
check_load_for_open_low | 4B16 | msrc_UNKNOWN | Details | ||
check_valve_pos_alimit | 4D64 | msrc_UNKNOWN | Details | ||
meth_warn_diag_reset_select | 4B2F | msrc_UNKNOWN | Details | ||
m_init_flow_mod_table_defaults | 4C78 | Init Table With Default Curve | msrc_UNKNOWN | Details | |
m_set_predefined_curve_method | 4075 | Init Table with Predefined Curves | Send one of the predefined flow modification curves to the device. You must set Modification Type to 'Custom Table' to use this curve. You can select 1) Linear Curve 2)1/25 Curve 3)Quick 1/25 Curve 4)1/33 Curve 5)Quick 1/33 Curve 6)1/50 Curve 7) Quick 1/50 Curve | msrc_UNKNOWN | Details |
m_multipoint_step_test | 4878 | Start Test | msrc_UNKNOWN | Details | |
m_set_predefined_multipoint_test | 4877 | Initialise Multipoint Step Test with Predefined Steps | Set one of the predefined step set to Multipoint Step Test values | msrc_UNKNOWN | Details |
m_get_mpst_offline_test_results | 4965 | msrc_UNKNOWN | Details | ||
m_get_dlt_offline_test_results | 49E0 | msrc_UNKNOWN | Details | ||
m_get_deadband_offline_test_results | 4967 | msrc_UNKNOWN | Details | ||
m_get_voat_offline_test_results | 49F7 | msrc_UNKNOWN | Details | ||
m_get_vlv_analysis_test_results | 4A61 | msrc_UNKNOWN | Details | ||
m_send_predefined_curve_method | 4076 | Send User Curve | Send User Curve | msrc_UNKNOWN | Details |
m_dynamic_loop_test | 49D5 | Start Test | msrc_UNKNOWN | Details | |
m_set_predefined_D_loop_test | 49D4 | Initialise Dynamic Loop Test with Predefined Values | Set predefined values to Dynamic Loop Test | msrc_UNKNOWN | Details |
m_valve_analysis_test | 49EB | Start Test | msrc_UNKNOWN | Details | |
m_set_predefined_valve_analysi_test | 49EA | Initialise Valve Analysis Test with Predefined Values | Set predefined values to Valve Analysis Test | msrc_UNKNOWN | Details |
m_valve_deadband_test | 4A6A | Start Test | msrc_UNKNOWN | Details | |
m_set_predefined_valve_deadband_test | 4A69 | Initialise Valve Deadband Test with Predefined Values | Set predefined values to Deadband Test | msrc_UNKNOWN | Details |
init_read_events_method_new | 4AC9 | Newest events | msrc_UNKNOWN | Details | |
previous_read_events_method_new | 4ACD | Previous 10 events | msrc_UNKNOWN | Details | |
next_read_events_method_new | 4ACB | Next 10 events | msrc_UNKNOWN | Details | |
set_default_status_config_method | 40B6 | Enable All Statuses | msrc_UNKNOWN | Details | |
disable_all_status_config_method | 40B7 | Disable All Statuses | msrc_UNKNOWN | Details | |
m_get_prs_up_flash_data | 4D42 | msrc_UNKNOWN | Details | ||
m_get_prs_down_flash_data | 4D59 | msrc_UNKNOWN | Details | ||
change_pressure_unit_method | 4D12 | Pressure Unit | msrc_UNKNOWN | Details | |
change_temperature_unit_method | 4D13 | Temperature Unit | msrc_UNKNOWN | Details | |
m_show_burst_command_configuration | 4D10 | Show Burst Mode Configuration | msrc_UNKNOWN | Details | |
m_configure_burst_command | 4D11 | Configure Burst Mode Messages | msrc_UNKNOWN | Details | |
warning_message | 1017 | Установить ручн. реж. контура | msrc_UNKNOWN | Details | |
Name | ID | Label | Description | Type | Source |