Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
convert_decimal_to_bcd1 | 406B | msrc_UNKNOWN | Details | ||
convert_decimal_to_bcd2 | 404F | msrc_UNKNOWN | Details | ||
convert_decimal_to_bcd3 | 406D | msrc_UNKNOWN | Details | ||
convert_bcd_to_decimal1 | 406C | msrc_UNKNOWN | Details | ||
convert_bcd_to_decimal2 | 4050 | msrc_UNKNOWN | Details | ||
load_defaults | 40E9 | Load Defaults | Load Defaults: Restores the Control Unit to its ex-factory settings. | msrc_UNKNOWN | Details |
restart_method | 40EA | Restart Device | Restart Device - the transmitter will be restarted. | msrc_UNKNOWN | Details |
set_date_method | 40EB | Set Present Date | Set the current date on the control unit. | msrc_UNKNOWN | Details |
basic_setup_method | 40EC | Basic Setup | Set up the control unit to measure Sludge Density using known information. | msrc_UNKNOWN | Details |
alert_status_method | 414A | Active Alerts | msrc_UNKNOWN | Details | |
refresh_alerts_method | 4140 | Refresh Alerts | Select to update alerts. | msrc_UNKNOWN | Details |
alert_status_ROM_checksum_error_method | 4141 | F: ROM Checksum Error | msrc_UNKNOWN | Details | |
alert_status_EEPROM_signature_error_method | 4142 | F: EEPROM Signature Error | msrc_UNKNOWN | Details | |
alert_status_EEPROM_checksum_error_method | 4143 | F: EEPROM Checksum Error | msrc_UNKNOWN | Details | |
alert_status_RAM_test_error_method | 4144 | F: RAM Test Failure | msrc_UNKNOWN | Details | |
alert_status_retries_olim_method | 4145 | M: Retries Out of Limits | msrc_UNKNOWN | Details | |
alert_status_pv_olim_method | 4146 | A: PV Out of Limits | msrc_UNKNOWN | Details | |
alert_status_current_fixed_method | 4147 | A: Current Fixed | msrc_UNKNOWN | Details | |
no_active_alerts_method | 4148 | No Active Alerts | msrc_UNKNOWN | Details | |
loop_test | 1002 | Loop Test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
dac_trim | 1004 | D/A Trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
applied_rerange | 1007 | Apply Values | Applied values- Perform a device rerange by applying the desired Upper Range Value and Lower Range Values to the device input | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |