sensor_setup_meth | 427C | Sensor Selection | This selection must be made to enable calibration parameters to be visible for the selected sensor type. | msrc_UNKNOWN | Details |
api_setup | 42C0 | API Setup | This method will step the user through setting up the API parameters. | msrc_UNKNOWN | Details |
mmi_auto_zero | 42B8 | Perform auto zero | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_a | 42D0 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_b | 42D1 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_c | 42D2 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_d | 42D3 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_fd | 42D4 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
temp_offset_cal | 4300 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
temp_slope_cal | 4301 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
write_discrete_assignment_meth | 4293 | Assign Discretes | Assigns a discrete to an action. Select none for no discrete assignment. | msrc_UNKNOWN | Details |
read_discrete_assignment_meth | 4294 | Read Action Assign | For a selected discrete action, reports the associated discrete assignment. | msrc_UNKNOWN | Details |
review_discrete_assignment_meth | 4295 | Action Assignments | Cycles through the discrete actions and reports the associated discrete assignments. | msrc_UNKNOWN | Details |
read_di_1_state | 4277 | Read Discrete In | Reads the state of the Discrete Input. | msrc_UNKNOWN | Details |
read_di_2_state | 4278 | Read DI 2 | Reads the state of the Discrete Input. | msrc_UNKNOWN | Details |
read_do_1_state | 4274 | Read DO 1 | Reads the state of the Discrete Output. | msrc_UNKNOWN | Details |
read_do_2_state | 4275 | Read DO 2 | Reads the state of the Discrete Output. | msrc_UNKNOWN | Details |
read_do_3_state | 4276 | Read DO 3 | Reads the state of the Discrete Output. | msrc_UNKNOWN | Details |
fix_do_1 | 426E | Fix Discrete Out 1 | Outputs a user-programmed discrete state to the discrete output. | msrc_UNKNOWN | Details |
fix_do_2 | 426F | Fix Discrete Out 2 | Outputs a user-programmed discrete state to the discrete output. | msrc_UNKNOWN | Details |
fix_do_3 | 4270 | Fix Discrete Out 3 | Outputs a user-programmed discrete state to the discrete output. | msrc_UNKNOWN | Details |
fix_frequency | 426D | Fix Frequency Out | Outputs a user-programmed frequency to the frequency output. | msrc_UNKNOWN | Details |
fix_ao_1 | 426B | Fix Analog Out 1 | Фиксированный аналоговый выход - позволяет пользователю вручную управлять выбранным аналоговым выходом путем установки в любое значение | msrc_UNKNOWN | Details |
analog_1_trim | 4271 | Trim Analog Out 1 | Цифровая-аналоговая регулировка - обеспечивает калибровку выбранного аналогового выхода, по внешнему образцовому прибору крайних рабочих точек аналогового выхода | msrc_UNKNOWN | Details |
fix_ao_2 | 426C | Fix Analog Out 2 | Фиксированный аналоговый выход - позволяет пользователю вручную управлять выбранным аналоговым выходом путем установки в любое значение | msrc_UNKNOWN | Details |
analog_2_trim | 4272 | Trim Analog Out 2 | Цифровая-аналоговая регулировка - обеспечивает калибровку выбранного аналогового выхода, по внешнему образцовому прибору крайних рабочих точек аналогового выхода | msrc_UNKNOWN | Details |
scaled_dac_trim_ao2 | 4273 | Scaled AO2 trim | Цифровая-аналоговая регулировка по масштабу - обеспечивает калибровку аналогового выхода, по внешнему образцовому прибору крайних рабочих точек аналогового выхода | msrc_UNKNOWN | Details |
self_test | 426A | Самотестирование | Instructs transmitter to perform internal self test. | msrc_UNKNOWN | Details |
start_total | 4264 | Start totalizer | Enables the internal totalizers to begin counting. | msrc_UNKNOWN | Details |
stop_total | 4265 | Stop totalizer | Prevents the internal totalizers from counting. | msrc_UNKNOWN | Details |
reset_all_total | 4266 | Reset all totals | Resets internal totalizers. | msrc_UNKNOWN | Details |
reset_mass_total | 4267 | Reset mass total | Resets internal totalizers. | msrc_UNKNOWN | Details |
reset_vol_total | 4268 | Reset volume total | Resets internal totalizers. | msrc_UNKNOWN | Details |
batch_ctl_meth | 4269 | Batcher cntrl | Allows the user to start, stop, end, inhibit, reset or resume a batch. Also allows user to print batch ticket or inhibit batch totalizers. | msrc_UNKNOWN | Details |
pc1_stat | 42CB | Статус | When set, indicates that the Discrete Event has reached its programmed trigger point. | msrc_UNKNOWN | Details |
pc2_stat | 42CC | Статус | When set, indicates that the Discrete Event has reached its programmed trigger point. | msrc_UNKNOWN | Details |
pc3_stat | 42CD | Статус | When set, indicates that the Discrete Event has reached its programmed trigger point. | msrc_UNKNOWN | Details |
pc4_stat | 42CE | Статус | When set, indicates that the Discrete Event has reached its programmed trigger point. | msrc_UNKNOWN | Details |
pc5_stat | 42CF | Статус | When set, indicates that the Discrete Event has reached its programmed trigger point. | msrc_UNKNOWN | Details |
do1_stat | 4308 | Status DO1 | When set, indicates that DO 1 has been triggered. | msrc_UNKNOWN | Details |
view_xmtr_status | 4242 | View status | Reports any currently active device status information. | msrc_UNKNOWN | Details |
write_alarm_severity_meth | 429B | Write Severity | Allows the user to change the severity level of an alarm. The alarms are represented by their alarm number. For example, A26 is 26 and A102 is 102. | msrc_UNKNOWN | Details |
read_alarm_severity_meth | 429C | Read Severity | Reports the severity level of the selected alarm. The alarms are represented by their alarm number. For example, A26 is 26 and A102 is 102. | msrc_UNKNOWN | Details |
review_alarm_severity_meth | 429D | Review Severity | Reports the severity level of all the alarms. | msrc_UNKNOWN | Details |
reset_historical_alarm_log_meth | 429E | Reset Alarm Log | Resets historical alarm log. | msrc_UNKNOWN | Details |
abort_auto_zero | 42FF | Aborts Auto Zero operation and continues to use previous zero offset value. | msrc_UNKNOWN | Details | |
leave_fixed_do1_mode | 4302 | Exits fixed mode and returns the discrete output to its active state. | msrc_UNKNOWN | Details | |
leave_fixed_do2_mode | 4303 | Exits fixed mode and returns the discrete output to its active state. | msrc_UNKNOWN | Details | |
leave_fixed_do3_mode | 4304 | Exits fixed mode and returns the discrete output to its active state. | msrc_UNKNOWN | Details | |
leave_fixed_freq_mode | 4305 | Exits fixed mode and returns the frequency output to its active state. | msrc_UNKNOWN | Details | |
mmi_leave_analog_fixed_current_mode1 | 4306 | Выход из режима фикс. тока | Выход из режима фиксированного тока - выводит выбранный аналоговый выход из режима, в котором выход был зафиксирован в постоянное значение, и переводит выход в режим, в котором он соотвествует входным данным | msrc_UNKNOWN | Details |
mmi_leave_analog_fixed_current_mode2 | 4307 | Выход из режима фикс. тока | Выход из режима фиксированного тока - выводит выбранный аналоговый выход из режима, в котором выход был зафиксирован в постоянное значение, и переводит выход в режим, в котором он соотвествует входным данным | msrc_UNKNOWN | Details |
abort_send | 42FE | msrc_UNKNOWN | Details | ||
must_send_pv | 4001 | msrc_UNKNOWN | Details | ||
must_send_sv | 4003 | msrc_UNKNOWN | Details | ||
must_send_tv | 4005 | msrc_UNKNOWN | Details | ||
must_send_event_var | 4309 | msrc_UNKNOWN | Details | ||
must_send_units | 4010 | msrc_UNKNOWN | Details | ||
must_send_scaling | 4129 | msrc_UNKNOWN | Details | ||
must_send_fi_scaling | 4130 | msrc_UNKNOWN | Details | ||
must_send_fault_level | 414A | msrc_UNKNOWN | Details | ||
warning_message | 1017 | Установить ручн. реж. контура | msrc_UNKNOWN | Details | |
scaled_dac_trim | 1005 | Scaled AO1 trim | Цифровая-аналоговая регулировка по масштабу - обеспечивает калибровку аналогового выхода, по внешнему образцовому прибору крайних рабочих точек аналогового выхода | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Отмена возврата в норм. сост. | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | Выход из режима фикс. тока | Выход из режима фиксированного тока - выводит выбранный аналоговый выход из режима, в котором выход был зафиксирован в постоянное значение, и переводит выход в режим, в котором он соотвествует входным данным | msrc_UNKNOWN | Details |