Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
sensor_setup_meth | 414F | Sensor Selection | This selection must be made to enable calibration parameters to be visible for the selected sensor type. | msrc_UNKNOWN | Details |
mmi_auto_zero | 4164 | Perform auto zero | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_a | 416E | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_b | 416F | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_c | 4170 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_d | 4171 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_fd | 4172 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
temp_offset_cal | 418F | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
temp_slope_cal | 4190 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
fix_frequency | 414A | Fix Frequency Out | Outputs a user-programmed frequency to the frequency output. | msrc_UNKNOWN | Details |
fix_ao_1 | 4149 | Fix Analog Out 1 | Saída analógica fixada- Permite o usuário a manipular manualmente a saídaanalógico para o valor de saída da constant selecionada | msrc_UNKNOWN | Details |
analog_1_trim | 414B | Trim Analog Out 1 | Digital para ajuste analógico- Permite a calibração da saída analógica selecionada com uma referência externa nos endpoints de operação da saída analógica | msrc_UNKNOWN | Details |
self_test | 4148 | Auto teste | Instructs transmitter to perform internal self test. | msrc_UNKNOWN | Details |
start_total | 4143 | Start totalizer | Enables the internal totalizers to begin counting. | msrc_UNKNOWN | Details |
stop_total | 4144 | Stop totalizer | Prevents the internal totalizers from counting. | msrc_UNKNOWN | Details |
reset_all_total | 4145 | Reset all totals | Resets internal totalizers. | msrc_UNKNOWN | Details |
reset_mass_total | 4146 | Reset mass total | Resets internal totalizers. | msrc_UNKNOWN | Details |
reset_vol_total | 4147 | Reset volume total | Resets internal totalizers. | msrc_UNKNOWN | Details |
alarm1_stat | 4162 | Status Event1 | When set, indicates that Event 1 has reached its programmed setpoint. | msrc_UNKNOWN | Details |
alarm2_stat | 4163 | Status Event2 | When set, indicates that Event 2 has reached its programmed setpoint. | msrc_UNKNOWN | Details |
view_xmtr_status | 412B | View status | Reports any currently active device status information. | msrc_UNKNOWN | Details |
abort_auto_zero | 418D | Aborts Auto Zero operation and continues to use previous zero offset value. | msrc_UNKNOWN | Details | |
leave_fixed_freq_mode | 4191 | Exits fixed mode and returns the frequency output to its active state. | msrc_UNKNOWN | Details | |
mmi_leave_analog_fixed_current_mode1 | 4192 | Deixar o modo fixado atual | Modo Atual de de de deixar fixo – Leva a saída analógica do modo onde a saída foi um valor constante, e retorna a saída para o modo onde a saída segue a entrada | msrc_UNKNOWN | Details |
abort_send | 418E | msrc_UNKNOWN | Details | ||
must_send_pv | 4001 | msrc_UNKNOWN | Details | ||
must_send_sv | 4003 | msrc_UNKNOWN | Details | ||
must_send_tv | 4005 | msrc_UNKNOWN | Details | ||
must_send_event_var | 4193 | msrc_UNKNOWN | Details | ||
must_send_units | 400D | msrc_UNKNOWN | Details | ||
must_send_scaling | 40D1 | msrc_UNKNOWN | Details | ||
must_send_fault_level | 40E7 | msrc_UNKNOWN | Details | ||
read_modbus_register | 43BA | Read Modbus Data Value | msrc_UNKNOWN | Details | |
write_modbus_register | 43BB | Write Modbus Data Value | msrc_UNKNOWN | Details | |
write_alarm_severity_meth | 436E | Write Severity | Allows the user to change the severity level of an alarm. The alarms are represented by their alarm number. For example, A26 is 26 and A102 is 102. | msrc_UNKNOWN | Details |
read_alarm_severity_meth | 436F | Read Severity | Reports the severity level of the selected alarm. The alarms are represented by their alarm number. For example, A26 is 26 and A102 is 102. | msrc_UNKNOWN | Details |
review_alarm_severity_meth | 4370 | Review Severity (All) | Reports the severity level of all the alarms. | msrc_UNKNOWN | Details |
select_acknowledge_alarm | 4371 | Acknowledge the selected alarm | msrc_UNKNOWN | Details | |
refresh_alarm_history | 4373 | Refresh Alarm Event Log | Uploads the 50 alarm history records from the device. This method takes approximately 30 sec to run. | msrc_UNKNOWN | Details |
perform_varDiagnostic_Action_Code | 4361 | Perform Diagnostic Action | msrc_UNKNOWN | Details | |
write_discrete_assignment_meth | 43A6 | Assign Discretes | Assigns a discrete to an action. Select none for no discrete assignment. | msrc_UNKNOWN | Details |
read_discrete_assignment_meth | 43A7 | Read Action Assign | For a selected discrete action, reports the associated discrete assignment. | msrc_UNKNOWN | Details |
review_discrete_assignment_meth | 43A8 | Read Action Assign (All) | Cycles through the discrete actions and reports the associated discrete assignments. | msrc_UNKNOWN | Details |
write_simulation_params_massflow | 43A9 | Simulate Mass Flow | msrc_UNKNOWN | Details | |
write_simulation_params_temp | 43AA | Simulate Temperature | msrc_UNKNOWN | Details | |
write_simulation_params_Density | 43AB | Simulate Density | msrc_UNKNOWN | Details | |
meth_meter_verification | 4367 | Meter Verification | Starts meter verification and shows the result PASS or FAIL. This procedure takes upto 4 minutes. | msrc_UNKNOWN | Details |
abort_meter_verification | 43BC | msrc_UNKNOWN | Details | ||
reset_gas_std_vol_total | 4366 | Reset Gas std. vol. total | Resets internal totalizers for Gas Standard Volume Total. | msrc_UNKNOWN | Details |
pc1_stat | 43DA | Status | When set, indicates that the Discrete Event has reached its programmed trigger point. | msrc_UNKNOWN | Details |
pc2_stat | 43DB | Status | When set, indicates that the Discrete Event has reached its programmed trigger point. | msrc_UNKNOWN | Details |
pc3_stat | 43DC | Status | When set, indicates that the Discrete Event has reached its programmed trigger point. | msrc_UNKNOWN | Details |
pc4_stat | 43DD | Status | When set, indicates that the Discrete Event has reached its programmed trigger point. | msrc_UNKNOWN | Details |
pc5_stat | 43DE | Status | When set, indicates that the Discrete Event has reached its programmed trigger point. | msrc_UNKNOWN | Details |
warning_message | 1017 | Ajustar malha para manual | msrc_UNKNOWN | Details | |
scaled_dac_trim | 1005 | Scaled AO1 trim | Digital para ajuste analógico escalado- Permite a calibração da saída analógica selecionada com uma referência externa nos endpoints de operação da saída analógica | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Abortar retorno para normal | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | Deixar o modo fixado atual | Modo atual de deixar fixado- Leva uma saída analógica para fora do modo onde a saída foi um valor constant, e retorna a saída para o modo onde a saída segue a entrada | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |