Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
sensor_setup_meth | 414F | Sensor Selection | This selection must be made to enable calibration parameters to be visible for the selected sensor type. | msrc_UNKNOWN | Details |
mmi_auto_zero | 4164 | Perform auto zero | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_a | 416E | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_b | 416F | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_c | 4170 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_d | 4171 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_fd | 4172 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
temp_offset_cal | 418F | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
temp_slope_cal | 4190 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
fix_frequency | 414A | Fix Frequency Out | Outputs a user-programmed frequency to the frequency output. | msrc_UNKNOWN | Details |
fix_ao_1 | 4149 | Fix Analog Out 1 | 固定アナログ出力 - ユーザーが選択したアナログ出力を選択した値で固定出力します。 | msrc_UNKNOWN | Details |
analog_1_trim | 414B | Trim Analog Out 1 | D/A トリム (デジタル/アナログ トリム) - オペレーティング エンド ポイントに対するアナログ出力と外部指示計とのキャリブレーションを行います。 | msrc_UNKNOWN | Details |
self_test | 4148 | セルフ テスト | Instructs transmitter to perform internal self test. | msrc_UNKNOWN | Details |
start_total | 4143 | Start totalizer | Enables the internal totalizers to begin counting. | msrc_UNKNOWN | Details |
stop_total | 4144 | Stop totalizer | Prevents the internal totalizers from counting. | msrc_UNKNOWN | Details |
reset_all_total | 4145 | Reset all totals | Resets internal totalizers. | msrc_UNKNOWN | Details |
reset_mass_total | 4146 | Reset mass total | Resets internal totalizers. | msrc_UNKNOWN | Details |
reset_vol_total | 4147 | Reset volume total | Resets internal totalizers. | msrc_UNKNOWN | Details |
alarm1_stat | 4162 | Status Event1 | When set, indicates that Event 1 has reached its programmed setpoint. | msrc_UNKNOWN | Details |
alarm2_stat | 4163 | Status Event2 | When set, indicates that Event 2 has reached its programmed setpoint. | msrc_UNKNOWN | Details |
view_xmtr_status | 412B | View status | Reports any currently active device status information. | msrc_UNKNOWN | Details |
abort_auto_zero | 418D | Aborts Auto Zero operation and continues to use previous zero offset value. | msrc_UNKNOWN | Details | |
leave_fixed_freq_mode | 4191 | Exits fixed mode and returns the frequency output to its active state. | msrc_UNKNOWN | Details | |
mmi_leave_analog_fixed_current_mode1 | 4192 | 固定電流モードを終ります | 現在の固定モードを終了 - 選択したアナログ出力を定数値のモードから移行させ, 出力が入力に応じて変わるモードに戻します。 | msrc_UNKNOWN | Details |
abort_send | 418E | msrc_UNKNOWN | Details | ||
must_send_pv | 4001 | msrc_UNKNOWN | Details | ||
must_send_sv | 4003 | msrc_UNKNOWN | Details | ||
must_send_tv | 4005 | msrc_UNKNOWN | Details | ||
must_send_event_var | 4193 | msrc_UNKNOWN | Details | ||
must_send_units | 400D | msrc_UNKNOWN | Details | ||
must_send_scaling | 40D1 | msrc_UNKNOWN | Details | ||
must_send_fault_level | 40E7 | msrc_UNKNOWN | Details | ||
warning_message | 1017 | ループをマニュアルにします | msrc_UNKNOWN | Details | |
scaled_dac_trim | 1005 | Scaled AO1 trim | スケーリング D/A トリム - オペレーティング エンド ポイントに対する選択したアナログ出力と外部指示系とのキャリブレーションを行います。 | msrc_UNKNOWN | Details |
return_to_normal | 1016 | ノーマル モードに戻します | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | 固定電流モードを終ります | 現在の固定モードを終了 - アナログ出力を定数値のモードから移行させ, 出力が入力に応じて変わるモードに戻します。 | msrc_UNKNOWN | Details |