Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
mmi_auto_zero | 4124 | オート ゼロ実行中 | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_a | 412E | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_b | 412F | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
dencal_c | 4130 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
visc_slope | 4132 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
visc_offset | 4133 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
temp_offset_cal | 4135 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
temp_slope_cal | 4134 | Perform Cal | Please refer to manual for complete calibration instructions. | msrc_UNKNOWN | Details |
fix_frequency | 410E | 固定周波数出力 | Outputs a user-programmed frequency to the frequency output. | msrc_UNKNOWN | Details |
fix_ao_1 | 410C | Fix Analog Out 1 | 固定アナログ出力 - ユーザーが選択したアナログ出力を選択した値で固定出力します。 | msrc_UNKNOWN | Details |
fix_ao_2 | 410D | Fix Analog Out 2 | 固定アナログ出力 - ユーザーが選択したアナログ出力を選択した値で固定出力します。 | msrc_UNKNOWN | Details |
analog_1_trim | 40F7 | Trim Analog Out 1 | D/A トリム (デジタル/アナログ トリム) - オペレーティング エンド ポイントに対するアナログ出力と外部指示計とのキャリブレーションを行います。 | msrc_UNKNOWN | Details |
analog_2_trim | 40F8 | Trim Analog Out 2 | D/A トリム (デジタル/アナログ トリム) - オペレーティング エンド ポイントに対するアナログ出力と外部指示計とのキャリブレーションを行います。 | msrc_UNKNOWN | Details |
self_test | 410B | セルフ テスト | Instructs transmitter to perform internal self test. | msrc_UNKNOWN | Details |
start_total | 4102 | Start totalizer | Enables the internal totalizers to begin counting. Also enables the frequency/pulse output to indicate flow. | msrc_UNKNOWN | Details |
stop_total | 4103 | Stop totalizer | Prevents the internal totalizers from counting. Disables the frequency/pulse output from indicating flow. | msrc_UNKNOWN | Details |
reset_total | 4104 | Reset totalizer | Resets internal totalizers. | msrc_UNKNOWN | Details |
alarm1_stat | 4122 | Status Alarm1 | When set, indicates that Event 1 has reached its programmed setpoint. | msrc_UNKNOWN | Details |
alarm2_stat | 4123 | Status Alarm2 | When set, indicates that Event 2 has reached its programmed setpoint. | msrc_UNKNOWN | Details |
view_xmtr_status | 40F2 | View status | Reports any currently active device status information. | msrc_UNKNOWN | Details |
calc_min_flow | 4131 | Min mass flow | Minimum flow rate (in g/s) required for a 3rd point density calibration. | msrc_UNKNOWN | Details |
abort_auto_zero | 4154 | Aborts Auto Zero operation and continues to use previous zero offset value. | msrc_UNKNOWN | Details | |
leave_fixed_freq_mode | 4155 | Exits fixed mode and returns the frequency output to its active state. | msrc_UNKNOWN | Details | |
mmi_leave_analog_fixed_current_mode1 | 4156 | 固定電流モードを終ります | 現在の固定モードを終了 - 選択したアナログ出力を定数値のモードから移行させ, 出力が入力に応じて変わるモードに戻します。 | msrc_UNKNOWN | Details |
mmi_leave_analog_fixed_current_mode2 | 4157 | 固定電流モードを終ります | 現在の固定モードを終了 - 選択したアナログ出力を定数値のモードから移行させ, 出力が入力に応じて変わるモードに戻します。 | msrc_UNKNOWN | Details |
abort_send | 4158 | msrc_UNKNOWN | Details | ||
must_send_pv | 4001 | msrc_UNKNOWN | Details | ||
must_send_sv | 4002 | msrc_UNKNOWN | Details | ||
must_send_tv | 4004 | msrc_UNKNOWN | Details | ||
must_send_event_var | 4159 | msrc_UNKNOWN | Details | ||
must_send_units | 4194 | msrc_UNKNOWN | Details | ||
warning_message | 1017 | ループをマニュアルにします | msrc_UNKNOWN | Details | |
Name | ID | Label | Description | Type | Source |