Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
Refresh_History_table | 41A7 | View History | Displays current status and run time as well as a history of most recent faults and warnings. For each event, the run time when the event occurred and the duration of the event are shown. The run time is the time since power up or a history reset. The table of history events displays the most recent event at the top with successively preceding events in descending order. | msrc_UNKNOWN | Details |
HistReset_method | 41AA | Reset History | Clears entries in Status History and resets the run time to zero. | msrc_UNKNOWN | Details |
RTD_Calibration | 4233 | Calibrate RTDs | Use this function to calibrate the probe RTDs for the temperature and flow measurements. The probe tip must be submerged in a constant temperature water bath. A separate accurate temperature reading device must be used to determine the actual water bath temperature. An inaccurate calibration temperature entry will result in performance that is out of specification or a non-functional unit. | msrc_UNKNOWN | Details |
exit_rtd_cal | 423B | Exit RTD Cal | msrc_UNKNOWN | Details | |
Heater_Calibration | 423A | Calibrate Heater | Use this menu to calibrate the PWM settings for the heater current control. An accurate ammeter must be connected in series with the heater wiring. When prompted, enter the value of the current displayed on the ammeter. Press 'Save' to store the present setting. After the actual currents corresponding to the 50 mA and 200 mA settings are saved, the device will compute the heater slope and intercept. The device will report the results of the calibration as the Heater Calibration parameter. An inaccurate heater calibration entry will result in performance that is out of specification or a non-functional unit. | msrc_UNKNOWN | Details |
exit_htr_cal | 423C | Exit Heater Cal | msrc_UNKNOWN | Details | |
Zero_Power_Test | 4226 | Zero Power Test | This test checks that the resistances of the temperature sensors have not changed. The test should be performed either in a water bath or under flowing conditions. During the test, the heater drive current is shut off. The measured ambient temperature should match the actual ambient temperature. See the TA2 Installation and Operations Manual for other details of the test. | msrc_UNKNOWN | Details |
Low_Cal_Validation | 4227 | Low Cal Validation | This procedure validates the heat transfer characteristics of the sensor under low flow conditions. Perform the test at room temperature with the sensor supported vertically. A shroud should be placed around the sensor tip to isolate the tip from air currents. The shroud should not be tight against the sensor tip. During the test, the heater drive current is set to a pre-set value. The measured Delta T temperature (the temperature difference between the two pins) is measured and compared against a stored value. See the TA2 Installation and Operations Manual for other details of the test including recommended comparison between the measured and stored values. | msrc_UNKNOWN | Details |
High_Cal_Validation | 4228 | High Cal Validation | This procedure validates the heat transfer characteristics of the sensor under high flow conditions. Perform the test in room temperature water with the sensor supported vertically. The sensor must be completely covered and the water must be kept still. During the test, the heater drive current is set to a pre-set value. The measured Delta T temperature (the temperature difference between the two pins) is measured and compared against a stored value. See the TA2 Installation and Operations Manual for other details of the test including recommended comparison between the measured and stored values. | msrc_UNKNOWN | Details |
exit_probe_check | 423D | Exit Probe Check | msrc_UNKNOWN | Details | |
PulseOutTest | 422A | Test Pulse | msrc_UNKNOWN | Details | |
exit_pulse_test | 4242 | Exit Pulse Test | msrc_UNKNOWN | Details | |
TempReset_method | 422D | Reset Temperatures | Reset the maximum and minimum temperatures measured for the electronics to the present temperature. | msrc_UNKNOWN | Details |
ProcessTempReset_method | 422C | Reset Temperatures | Reset the maximum process temperature measured at the probe to the present temperature. | msrc_UNKNOWN | Details |
TotalizerReset_method | 419C | Reset Totalizer | Reset Totalizer - Resets the totalizer and elapsed time to 0. | msrc_UNKNOWN | Details |
exit_fixed_htr | 422B | Exit Fixed Signal | msrc_UNKNOWN | Details | |
loop2_test | 4229 | AO2 Loop Test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value. | msrc_UNKNOWN | Details |
loop2_dac_trim | 41A2 | D/A Trim AO2 | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output. | msrc_UNKNOWN | Details |
leave_fixed_current_mode2 | 4298 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
reset_config_changed | 4222 | Reset Config Chgd | Resets the Configuration Changed bit in the Device Status | msrc_UNKNOWN | Details |
transmitter_dac_trim | 1024 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
transmitter_loop_test | 1023 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
Name | ID | Label | Description | Type | Source |