Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
forceJoinMode | 417E | Force Join | msrc_UNKNOWN | Details | |
set_join_key | 416C | Set Join Key | msrc_UNKNOWN | Details | |
join_network | 416B | Join Device To Network | msrc_UNKNOWN | Details | |
two_point_calibration | 414D | Two-point Calibration | Automatic calibration using two known thicknesses on a step plate. | msrc_UNKNOWN | Details |
clearReferenceTemp | 41A3 | Clear Ref Temp | Clear the reference temperature. It will be set again after the next thickness update is triggered. | msrc_UNKNOWN | Details |
restoreFactoryDefaults | 416A | Factory Defaults | Resets the device back to the factory default settings. | msrc_UNKNOWN | Details |
triggerThickness | 4147 | Trigger Thickness Update | Select the channel on which to trigger a thickness measurement | msrc_UNKNOWN | Details |
getCh1Waveform | 4154 | Get Channel 1 Waveform | Retrieves the waveform from the latest thickness measurement on channel 1. | msrc_UNKNOWN | Details |
getCh2Waveform | 4156 | Get Channel 2 Waveform | Retrieves the waveform from the latest thickness measurement on channel 2. | msrc_UNKNOWN | Details |
getCh3Waveform | 4158 | Get Channel 3 Waveform | Retrieves the waveform from the latest thickness measurement on channel 3. | msrc_UNKNOWN | Details |
getCh4Waveform | 415A | Get Channel 4 Waveform | Retrieves the waveform from the latest thickness measurement on channel 4. | msrc_UNKNOWN | Details |
SIMULATE_STATUS | 41C4 | Simulate Status | msrc_UNKNOWN | Details | |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
trim_warning | 1081 | Trim warning | msrc_UNKNOWN | Details | |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
device_self_test | 1071 | Self test | Autoverificación: Ordena a electrónica que realice una autoverificación. | msrc_UNKNOWN | Details |
device_master_reset | 1072 | Device reset | Reinicio del dispositivo: Ordena a la electrónica a que realice un reinicio. Esto equivale a apagar la alimentación del dispositivo de campo y luego volver a encenderla. | msrc_UNKNOWN | Details |
device_variable_trim | 1080 | Single-point Trim | Ajuste de variable de dispositivo: Permite que la medida de calibración de una variable de dispositivo se ajuste linealmente. El punto de ajuste que se envía al dispositivo debe representar el valor de variable del proceso aplicado actualmente. | msrc_UNKNOWN | Details |
device_variable_trim_reset | 1083 | Trim Reset | Restablecimiento de ajuste de variable de dispositivo: Permite que la variable de dispositivo se establezca en su ajuste de fábrica predeterminado. | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |