名称 | ID | 标签 | 描述 | 类型 | 源代码 |
---|---|---|---|---|---|
PreSetVersionDd | 40DF | PreSetVersionDd | msrc_UNKNOWN | 详细信息 | |
MthResetConfigChangedFlag | 40E0 | Reset Configuration Changed Flag | Reset of the HART 'Configuration Changed' flag. | msrc_UNKNOWN | 详细信息 |
MthResetDevice | 40E1 | Device reset | Perform a "cold start" (like power-on start). | msrc_UNKNOWN | 详细信息 |
MthUpdateBurstMessage_0 | 40FA | msrc_UNKNOWN | 详细信息 | ||
MthUpdateBurstDeviceVariableSelection0 | 40F8 | msrc_UNKNOWN | 详细信息 | ||
MthUpdateBurstMessage_1 | 410D | msrc_UNKNOWN | 详细信息 | ||
MthUpdateBurstDeviceVariableSelection1 | 410B | msrc_UNKNOWN | 详细信息 | ||
MthUpdateBurstMessage_2 | 4120 | msrc_UNKNOWN | 详细信息 | ||
MthUpdateBurstDeviceVariableSelection2 | 411E | msrc_UNKNOWN | 详细信息 | ||
MthUnlockExtendedRange | 41B1 | Unlock Extended Range | Unlock the extended range feature. The required code can be obtained from the manufacturer. (Fct. C7.2.4) | msrc_UNKNOWN | 详细信息 |
MthClearPasswordVariables | 41B2 | msrc_UNKNOWN | 详细信息 | ||
mthChangePasswordSecurity | 41C0 | Change Password | Change a password for a security role. Only the password for operator, expert and service can be changed. The number of leading zeros indicates the role-level (see above) (Fct. C7.2.2) | msrc_UNKNOWN | 详细信息 |
mthResetPasswordsSecurity | 41C1 | Reset Passwords | Here all changeable passwords (Operator, Expert & Service) can be reset. The required code can be obtained from the manufacturer. (Fct. C7.2.3) | msrc_UNKNOWN | 详细信息 |
mthChangeRoleSecurity | 41C3 | Login | Change the security role. The number of leading zeros in a password indicates the role-level: 000X -> Operator 00XX -> Expert 0XXX -> Service XXXX -> Factory (Fct. C7.2.1) | msrc_UNKNOWN | 详细信息 |
mthChangeRoleSecurityAbort | 41C4 | msrc_UNKNOWN | 详细信息 | ||
MthSetWriteProtect | 41C6 | (De)activate Write Protection | This function (de)activates the write protection. No changes to the device configuration are allowed as long as the write protection is active. | msrc_UNKNOWN | 详细信息 |
MthSetWriteProtectAbort | 41C7 | msrc_UNKNOWN | 详细信息 | ||
mthResetToFactoryDefault | 41C8 | Reset to Fact. Def.? | (Fct. C7.6.1) | msrc_UNKNOWN | 详细信息 |
mthResetLogMessages | 41CA | Reset Log-Messages? | (Fct. D4.1.2) | msrc_UNKNOWN | 详细信息 |
mthTransferCo1ParametersStandardSetupAssistant | 41CB | msrc_UNKNOWN | 详细信息 | ||
mthTransferCo2ParametersStandardSetupAssistant | 41CC | msrc_UNKNOWN | 详细信息 | ||
mthRecordEmptySpectrum | 41CD | Record Empty Spectrum | Records an Empty Spectrum and stores it into the device. | msrc_UNKNOWN | 详细信息 |
MthRunDeviceFunctionReset | 41C9 | msrc_UNKNOWN | 详细信息 | ||
PoeOflHandleDependenciesCdDevOutputCurrentA | 4168 | msrc_UNKNOWN | 详细信息 | ||
PoeOflHandleDependenciesCdDevOutputCurrentB | 416A | msrc_UNKNOWN | 详细信息 | ||
PoeOflHandleDependenciesCdDevTv | 416E | msrc_UNKNOWN | 详细信息 | ||
PoeOflHandleDependenciesCdDevQv | 416C | msrc_UNKNOWN | 详细信息 | ||
MthCalibrateSensorCurrentOutputA | 41E7 | Current Output 1 | The current output can be calibrated here (Fct. D3.1) | msrc_UNKNOWN | 详细信息 |
MthCalibrateSensorCurrentOutputB | 41E8 | Current Output 2 | The current output can be calibrated here (Fct. D3.2) | msrc_UNKNOWN | 详细信息 |
changeConversionFunction | 42F7 | Select Conversion | Create a new table for either volume, mass or a linearoized value (Fct. C3.1.3) | msrc_UNKNOWN | 详细信息 |
insertEntry | 42F8 | Insert Entry | Inserts a new Entry to the conversion table | msrc_UNKNOWN | 详细信息 |
insertEntryWetCalibration | 42F9 | Insert Entry (Wet Calibration) | Inserts a new Entry to the conversion table. When using the wet calibration, the current sensor value is used as the raw value. | msrc_UNKNOWN | 详细信息 |
deleteEntry | 42FB | Delete Entry | Deletes an Entry from the conversion table. | msrc_UNKNOWN | 详细信息 |
eraseConvTable | 42FC | Delete Table | Deletes the complete Conversion Table | msrc_UNKNOWN | 详细信息 |
tbloflInsertEntry | 42FD | Insert Entry | Inserts a new Entry to the conversion table | msrc_UNKNOWN | 详细信息 |
tbloflDeleteEntry | 42FE | Delete Entry | Deletes an Entry from the conversion table. | msrc_UNKNOWN | 详细信息 |
reset_condensed_status_map_meth | 456A | Reset Condensed Status Map | msrc_UNKNOWN | 详细信息 | |
MthResetCondensedStatusMap | 433C | Reset to default | Reset the mappings to the Condensed Status to default values. | msrc_UNKNOWN | 详细信息 |
MthSetSimulationBits | 433D | Set Simulation Bits | (De)activates the selected Simulation bits | msrc_UNKNOWN | 详细信息 |
MthChangeModeSimulationStatus | 433E | Enable/disable Status Simulation | Enable/disable status simulation. | msrc_UNKNOWN | 详细信息 |
mthStartRecordingEmptySpectrum | 433F | msrc_UNKNOWN | 详细信息 | ||
ActivateAssistantMode | 4342 | msrc_UNKNOWN | 详细信息 | ||
DeactivateAssistantMode | 4343 | msrc_UNKNOWN | 详细信息 | ||
wizEvaluatePageResult | 4344 | msrc_UNKNOWN | 详细信息 | ||
readCriticalParameters | 4345 | msrc_UNKNOWN | 详细信息 | ||
wizEntrymnuStandardSetupAssistant | 4346 | Standard Setup | Setup for a "standard" tank or stilling well | msrc_UNKNOWN | 详细信息 |
mthMakeBackup_mnuStandardSetupAssistant | 434D | msrc_UNKNOWN | 详细信息 | ||
mthAbort_mnuStandardSetupAssistant | 4347 | msrc_UNKNOWN | 详细信息 | ||
mthPostAll_mnuStandardSetupAssistant | 434E | msrc_UNKNOWN | 详细信息 | ||
mthPostPage_loc_mnuUnitsStandardSetupAssistant | 4363 | msrc_UNKNOWN | 详细信息 | ||
mthPostPage_loc_mnuTankParameterStandardSetupAssistant | 4364 | msrc_UNKNOWN | 详细信息 | ||
mthPostPage_loc_mnuCurrentOutputAStandardSetupAssistant | 4365 | msrc_UNKNOWN | 详细信息 | ||
mthPostPage_loc_mnuCurrentOutputBStandardSetupAssistant | 4366 | msrc_UNKNOWN | 详细信息 | ||
return_to_normal | 1016 | 中止返回正常 | msrc_UNKNOWN | 详细信息 | |
applied_rerange | 1007 | Apply values | Currently measured values will be taken as Upper Range Value and Lower Range Value for the PV current output. | msrc_UNKNOWN | 详细信息 |
leave_fixed_current_mode | 1003 | 退出固定电流模式 | 退出固定电流模式——使选择的模拟量输出退出输出为常数值的模式,使输出返回输出跟踪输入的模式。 | msrc_UNKNOWN | 详细信息 |
transmitter_loop_test | 1023 | 回路测试 | 回路测试——允许用户将选择的模拟量输出手动调节至选择的常数输出值。 | msrc_UNKNOWN | 详细信息 |
zero_trim | 1006 | Automatic zero calibration | Measures the process value for automatic zero adjust. (Fct. C1.6.3) | msrc_UNKNOWN | 详细信息 |
transmitter_dac_trim | 1024 | D/A trim PV | Calibration of the PV current output with an external reference. | msrc_UNKNOWN | 详细信息 |
leave_analog_fixed_current_mode | 1009 | 退出固定电流模式 | 退出固定电流模式——使选择的模拟量输出退出输出为常数值的模式,使输出返回输出跟踪输入的模式。 | msrc_UNKNOWN | 详细信息 |
fixed_analog_output | 1008 | Fix analog output | Manually manipulate a selected Analog Output to a selected constant output value. | msrc_UNKNOWN | 详细信息 |
analog_dac_trim | 100A | D/A trim Analog Output | Calibration of a selected output with an external reference. | msrc_UNKNOWN | 详细信息 |
lock_unlock_device | 1073 | Lock / Unlock Device | This function allows a master to temporarily or permanently lock an instrument while the device is being configured or calibrated (preventing any changes from a local panel of another master). Once the procedure is complete the locking master device must restore normal operation. If the lock is temporary then normal (unprotected) operation is also resumed when power is removed from device or upon performing a Device Reset. A permanent lock remains active after a device restart or reset. Unlock: Unlock the device. Lock temporary: Device parameters can't be accessed by another master or the local panel. Device lock is removed on device restart / reset. Lock permanent: Device parameters can't be changed by another master or the local panel. Device lock remains active after a device restart / reset. Lock all: Device parameters can't be changed by any application. Device lock remains active after a device restart / reset. Any Master can unlock the device. | msrc_UNKNOWN | 详细信息 |
warning_message | 1017 | Set Loop to manual | msrc_UNKNOWN | 详细信息 | |
名称 | ID | 标签 | 描述 | 类型 | 源代码 |