Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
portSelectMethod | 4057 | Port Select | msrc_UNKNOWN | Details | |
BuildSensor0Version | 4062 | Sensor Version | msrc_UNKNOWN | Details | |
BuildSensor1Version | 406E | Sensor Version | msrc_UNKNOWN | Details | |
Analog0alarmFixedCheck | 4074 | Analog 1 Fixed Check | msrc_UNKNOWN | Details | |
Analog0alarmOverCheck | 4075 | Analog 1 Over Limit Check | msrc_UNKNOWN | Details | |
Analog0alarmUnderCheck | 4076 | Analog 1 Under Limit Check | msrc_UNKNOWN | Details | |
Analog1alarmFixedCheck | 4077 | Analog 2 Fixed Check | msrc_UNKNOWN | Details | |
Analog1alarmOverCheck | 4078 | Analog 2 Over Limit Check | msrc_UNKNOWN | Details | |
Analog1alarmUnderCheck | 4079 | Analog 2 Under Limit Check | msrc_UNKNOWN | Details | |
BuildFirmwareVersion1 | 4080 | Firmware Version | msrc_UNKNOWN | Details | |
BuildFirmwareVersion2 | 4081 | Firmware Version | msrc_UNKNOWN | Details | |
dv_zero_trim_1 | 41CC | Zero Trim Sensor 1 | Zero trim- Make the sensor input the new zero input reference | msrc_UNKNOWN | Details |
dv_zero_trim_2 | 41CD | Zero Trim Sensor 2 | Zero trim- Make the sensor input the new zero input reference | msrc_UNKNOWN | Details |
dv_zero_trim | 41DC | Zero trim | Zero trim- Make the sensor input the new zero input reference | msrc_UNKNOWN | Details |
dv_trim_1 | 41CE | Trim Sensor 1 | Ajuste de variable de dispositivo: Permite que la medida de calibración de una variable de dispositivo se ajuste linealmente. El punto de ajuste que se envía al dispositivo debe representar el valor de variable del proceso aplicado actualmente. | msrc_UNKNOWN | Details |
dv_trim_2 | 41CF | Trim Sensor 2 | Ajuste de variable de dispositivo: Permite que la medida de calibración de una variable de dispositivo se ajuste linealmente. El punto de ajuste que se envía al dispositivo debe representar el valor de variable del proceso aplicado actualmente. | msrc_UNKNOWN | Details |
dv_trim | 41DE | Sensor trim | Ajuste de variable de dispositivo: Permite que la medida de calibración de una variable de dispositivo se ajuste linealmente. El punto de ajuste que se envía al dispositivo debe representar el valor de variable del proceso aplicado actualmente. | msrc_UNKNOWN | Details |
clear_calibration_mode | 41DD | Clear calibration mode | msrc_UNKNOWN | Details | |
dv_trim_reset | 41D0 | Sensor trim reset | Restablecimiento de ajuste de variable de dispositivo: Permite que la variable de dispositivo se establezca en su ajuste de fábrica predeterminado. | msrc_UNKNOWN | Details |
xmtr_loop_test_1 | 41D7 | DAC 1 Loop Test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
xmtr_loop_test_2 | 41D8 | DAC 2 Loop Test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
xmtr_loop_test | 41DF | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
xmtr_dac_trim_1 | 41D9 | DAC 1 Trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
xmtr_dac_trim_2 | 41DA | DAC 2 Trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
xmtr_dac_trim | 41E1 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
dac_leave_fixed_crnt_mode | 41E0 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
dac_leave_calibration_mode | 41E2 | Leave Calibration Mode | Leave Calibration Mode | msrc_UNKNOWN | Details |
relay_unlatch | 41DB | Unlatch Relays | msrc_UNKNOWN | Details | |
device_master_reset_2 | 41CA | Device reset | Reinicio del dispositivo: Ordena a la electrónica a que realice un reinicio. Esto equivale a apagar la alimentación del dispositivo de campo y luego volver a encenderla. | msrc_UNKNOWN | Details |
applied_rerange | 1007 | Apply values | Applied values- Perform a device rerange by applying the desired Upper Range Value and Lower Range Values to the device input | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
device_self_test | 1071 | Self test | Autoverificación: Ordena a electrónica que realice una autoverificación. | msrc_UNKNOWN | Details |
device_master_reset | 1072 | Device reset | Reinicio del dispositivo: Ordena a la electrónica a que realice un reinicio. Esto equivale a apagar la alimentación del dispositivo de campo y luego volver a encenderla. | msrc_UNKNOWN | Details |
device_variable_trim | 1080 | Device variable trim | Ajuste de variable de dispositivo: Permite que la medida de calibración de una variable de dispositivo se ajuste linealmente. El punto de ajuste que se envía al dispositivo debe representar el valor de variable del proceso aplicado actualmente. | msrc_UNKNOWN | Details |
trim_warning | 1081 | Trim warning | msrc_UNKNOWN | Details | |
device_variable_trim_reset | 1083 | Device variable trim reset | Restablecimiento de ajuste de variable de dispositivo: Permite que la variable de dispositivo se establezca en su ajuste de fábrica predeterminado. | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |