Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
refresh_meas_gas_index_local | 4044 | msrc_UNKNOWN | Details | ||
mReadMeasurementGases | 4046 | msrc_UNKNOWN | Details | ||
mReadLelCategories | 404B | msrc_UNKNOWN | Details | ||
calc_degF_from_degC | 407A | msrc_UNKNOWN | Details | ||
calc_op_hours_diff | 407F | msrc_UNKNOWN | Details | ||
calc_op_days_diff | 4081 | msrc_UNKNOWN | Details | ||
calc_last_temp_degF_from_degC | 408E | msrc_UNKNOWN | Details | ||
calc_degF_from_degC_cpu | 40F3 | msrc_UNKNOWN | Details | ||
calcLongRangeCoordinates_Tx | 4104 | msrc_UNKNOWN | Details | ||
draw_target_circles2 | 41A3 | Draw target circles | msrc_UNKNOWN | Details | |
start_alignment_rx_new | 41A4 | Start alignment > | msrc_UNKNOWN | Details | |
start_alignment_tx_method | 41A6 | Start alignment > | msrc_UNKNOWN | Details | |
stop_alignment_for_zeroing_method | 41A7 | msrc_UNKNOWN | Details | ||
stop_alignment_rx_new | 41A8 | Stop alignment > | msrc_UNKNOWN | Details | |
stop_alignment_tx_method | 41A9 | Stop alignment > | msrc_UNKNOWN | Details | |
show_alignment_tx_method | 41AA | Show alignment > | msrc_UNKNOWN | Details | |
start_zeroing_method | 41AE | Zeroing > | msrc_UNKNOWN | Details | |
start_testspan_calibration_method | 41B0 | Test span > | Test Span mode sets the analog output to maintenance. The common digital gas measurement readings are set to unknown. By using a special command the gas reading will be displayed. The user is enabled to simulate/test gas measurements and to ensure the device is measuring properly. | msrc_UNKNOWN | Details |
exit_zeroing_method | 41AF | Exit zeroing mode | msrc_UNKNOWN | Details | |
exit_test_span_method | 41B1 | Exit test span | msrc_UNKNOWN | Details | |
set_sil_pin_0_method | 41B5 | Set Master SIL PIN > | msrc_UNKNOWN | Details | |
set_sil_pin_1_method | 41B6 | Set Maint. SIL PIN > | msrc_UNKNOWN | Details | |
set_sil_level_method | 41B7 | Set SIL lock > | Change the current SIL Lock level of the device. | msrc_UNKNOWN | Details |
show_sil_affected_parameters_method | 41BF | Show SIL affected parameters | msrc_UNKNOWN | Details | |
check_sil_level | 41C4 | Check SIL lock before calibration | Check SIL lock before calibration | msrc_UNKNOWN | Details |
reset_sil_to_full_lock | 41A5 | Set SIL lock after calibration | Set SIL lock after calibration | msrc_UNKNOWN | Details |
select_meas_gas | 41C5 | Select meas. gas > | Enables the user to change the measured gas. | msrc_UNKNOWN | Details |
warn_sil_lock | 41C6 | Device in SIL Lock | msrc_UNKNOWN | Details | |
post_edit_stop_test | 41CD | msrc_UNKNOWN | Details | ||
handle_selected_test | 41CE | msrc_UNKNOWN | Details | ||
do_analog_output_test | 41CF | 4-20 mA test > | msrc_UNKNOWN | Details | |
abort_ao_test | 41D0 | msrc_UNKNOWN | Details | ||
do_analog_calibration | 41D1 | 4-20 mA calibration > | msrc_UNKNOWN | Details | |
device_fundamental_initialisation | 41D2 | Fundamental Init. > | msrc_UNKNOWN | Details | |
set_poll_address | 41D3 | Set polling address > | msrc_UNKNOWN | Details | |
graph_alignment_hot_key | 41D4 | Graphical alignment | msrc_UNKNOWN | Details | |
text_alignment_hot_key | 41D5 | Text alignment | msrc_UNKNOWN | Details | |
refresh_link_present_local | 41F6 | msrc_UNKNOWN | Details | ||
refresh_device_model_and_distance | 41F7 | msrc_UNKNOWN | Details | ||
data_transfer | 41ED | Data transfer > | Choose type of data logger to be downladed and how many entries should be downloaded. The download starts with the latest entry first. If the download is stopped, the downloaded data is saved. The file is named "000052_52ef_xxxxxx.xml". It is stored at the memory card [if available :-)]. Fault logger: Contains the activated faults and warnings over time. Hour logger: Reports the status and faults of the device in two hours steps. The fault listing is shortend. Week logger: Reports the status and faults of the device in weekly steps. The fault listing is shortend. Draeger Science: Reports the status on developer level. | msrc_UNKNOWN | Details |
abort_reset_port | 4256 | Reset port > | msrc_UNKNOWN | Details | |
reset_all_ports | 41EE | Reset ports > | msrc_UNKNOWN | Details | |
warning_message | 1017 | ループをマニュアルにします | msrc_UNKNOWN | Details | |
transmitter_dac_trim | 1024 | 4-20 mA calibration | D/A トリム (デジタル/アナログ トリム) - オペレーティング エンド ポイントに対するアナログ出力と外部指示計とのキャリブレーションを行います。 | msrc_UNKNOWN | Details |
return_to_normal | 1016 | ノーマル モードに戻します | msrc_UNKNOWN | Details | |
leave_fixed_current_mode | 1003 | 固定電流モードを終ります | 現在の固定モードを終了 - アナログ出力を定数値のモードから移行させ, 出力が入力に応じて変わるモードに戻します。 | msrc_UNKNOWN | Details |
device_master_reset | 1072 | Device reset > | Device Reset - Commands the electronics to perform a reset. This is equivalent to cycling the power off and then back on to the field device. | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |