Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
dec_self_test_method | 4017 | Auto teste | Self test will perform all internal checks immediately and return results in variables xmtr flt 1 & xmtr flt 2. | msrc_UNKNOWN | Details |
dec_self_test_method_ams | 4018 | Auto teste | Self test will perform all internal checks immediately and return results in variables xmtr flt 1 & xmtr flt 2. | msrc_UNKNOWN | Details |
dec_abort_response_test | 401D | Abort response test | msrc_UNKNOWN | Details | |
dec_return_to_normal | 401E | return to normal | msrc_UNKNOWN | Details | |
x3301_method_oi_calibration | 4087 | Calibrate Oi | This procedure calibrates the Oi test signal for all three IR sensors. | msrc_UNKNOWN | Details |
x3301_method_start_passive_oi | 407D | Start Passive Oi | Test to check the cleanliness of the detector's optical surfaces and the ability to respond to an IR signal. Relays unaffected. | msrc_UNKNOWN | Details |
x3301_method_start_active_oi | 407E | Start Active Oi | Test to check the cleanliness of the detector's optical surfaces and the ability to respond to an IR signal. Relays are affected. | msrc_UNKNOWN | Details |
x3301_method_clear_oi_fault | 407F | Clear Oi Fault | Clear prior Oi faults. If the cause of the fault has not been corrected, subsequent Oi faults will occur. | msrc_UNKNOWN | Details |
x3301_method_reset_latches | 4080 | Reset Latches | Latching relays are reset. LED turns green. | msrc_UNKNOWN | Details |
x3301_method_hardware_reset | 401C | Master Reset | Initiates a hardware reset for both the sensor and the HART interface. Latched relays are reset. | msrc_UNKNOWN | Details |
x3301_method_clear_logs | 4081 | Clear Data Log | Clears data log entries contained on the HART interface board. | msrc_UNKNOWN | Details |
x3301_method_alarm_log | 408F | Alarm Log | Scroll through 32 Alarm Logs with time, date, and temperature stamp. | msrc_UNKNOWN | Details |
x3301_method_fault_log | 4090 | Fault Log | Scroll through 32 Fault Logs with time, date, and temperature stamp. | msrc_UNKNOWN | Details |
x3301_method_general_log | 4091 | General Log | Scroll through 32 General Logs with time, date, and temperature stamp. | msrc_UNKNOWN | Details |
x3301_method_abort | 4092 | x3301 Abort Method. | msrc_UNKNOWN | Details | |
x3301_method_partnumber | 4089 | Part Number | Manufacturer's part number for this device. | msrc_UNKNOWN | Details |
x3301_method_datetime | 408A | Real Time Clock | Current time and date setting of real time clock. Format: month/day/year | msrc_UNKNOWN | Details |
x3301_method_serialnumber | 4088 | Serial Number | Serial number of device. | msrc_UNKNOWN | Details |
loop_test | 1002 | Teste de malha | Teste de malha- Permite o usuário a manipular manualemnte a saída analógica para o valor de saída de constante selecionada | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Deixar o modo fixado atual | Modo atual de deixar fixado- Leva uma saída analógica para fora do modo onde a saída foi um valor constant, e retorna a saída para o modo onde a saída segue a entrada | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Abortar retorno para normal | msrc_UNKNOWN | Details | |
dac_trim | 1004 | Ajuste D/A | Digital para ajuste analógico- Permite a calibração da saída analógica selecionada com uma referência externa nos endpoints de operação da saída analógica | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |