名称 | ID | 标签 | 描述 | 类型 | 源代码 |
---|---|---|---|---|---|
Restore_Factory_Defaults_menu | 413D | Restore Factory Setting | restore to factory | msrc_UNKNOWN | 详细信息 |
trim_pv_zero_flow | 4140 | Trim Zero | msrc_UNKNOWN | 详细信息 | |
trim_pv_zero_level | 4141 | Trim Zero | msrc_UNKNOWN | 详细信息 | |
trim_pv_zero_temp | 4142 | Trim Zero | msrc_UNKNOWN | 详细信息 | |
trim_pv_zero_prss | 4143 | Trim Zero | msrc_UNKNOWN | 详细信息 | |
Multipoint_Calibration | 4144 | Multipoint Calibration | Use when PV condition can be independently measured and adjusted for the calibration. Requires prior entry of specific gravity of test fluid(s), volume of displacer and displacer rod length. | msrc_UNKNOWN | 详细信息 |
Manual_Calibration | 4145 | Manual Cal intput | Use when PV condition can be independently measured and adjusted for the calibration. Requires prior entry of specific gravity of test fluid(s), volume of displacer and displacer rod length. | msrc_UNKNOWN | 详细信息 |
set_zero_4ma | 4146 | Set Zero(4mA) | Sets lower range value (4mA output) to the present internal PV value. Works like a zero control on an analog device- the span between upper and lower range values is preserved, so the URV moves also. This command does not adjust the internal PV calibration vs. the input condition ?Conly the relationship between input condition ?Conly the relationship between internal values and the output current. | msrc_UNKNOWN | 详细信息 |
set_span_20ma | 4147 | Set Span(20mA) | Sets upper range value (20mA output) to the present internal PV value. Works like a span control on an analog device ?C the existing lower range value will remain the same, only the span will be changed. This command does not adjust the internal PV calibration vs. the input condition ?C only the relationship between internal PV values and output current. | msrc_UNKNOWN | 详细信息 |
Guided_Setup | 4148 | Guided Setup | Guides user through initial configuration and calibration process | msrc_UNKNOWN | 详细信息 |
status_display_MENU | 4149 | Status | Reports any PV or temperature alarms that are active | msrc_UNKNOWN | 详细信息 |
Trim_procTemp | 414A | Proc Temp cali | msrc_UNKNOWN | 详细信息 | |
Densty_coff | 414B | Density Table | Used to select temperature coefficient table for Densty. | msrc_UNKNOWN | 详细信息 |
Sensor_setup | 414C | Sensor | Sensor Parameter | msrc_UNKNOWN | 详细信息 |
Sensor_Variables | 414D | Sensor | Sensor Parameter | msrc_UNKNOWN | 详细信息 |
FlowAcc_Reset | 414E | Reset FlowAcc | msrc_UNKNOWN | 详细信息 | |
Trim_SenTemp_zero | 4170 | Sen Temp Zero | msrc_UNKNOWN | 详细信息 | |
applied_rerange | 1007 | 应用数值 | 应用值——通过将需要的上限值和下限值应用至设备输入对设备执行重新排列。 | msrc_UNKNOWN | 详细信息 |
zero_trim | 1006 | 归零修正 | 归零修正——使传感器输入新归零输入参考。 | msrc_UNKNOWN | 详细信息 |
return_to_normal | 1016 | 中止返回正常 | msrc_UNKNOWN | 详细信息 | |
warning_message | 1017 | 设置回路为手动 | msrc_UNKNOWN | 详细信息 | |
device_self_test | 1071 | 自测试 | 自检——命令电子设备执行自检。 | msrc_UNKNOWN | 详细信息 |
device_master_reset | 1072 | 设备复位 | 设备复位——命令电子设备执行复位。该操作相当于将现场设备电源关闭然后再打开。 | msrc_UNKNOWN | 详细信息 |
transmitter_loop_test | 1023 | 回路测试 | 回路测试——允许用户将选择的模拟量输出手动调节至选择的常数输出值。 | msrc_UNKNOWN | 详细信息 |
leave_fixed_current_mode | 1003 | 退出固定电流模式 | 退出固定电流模式——使选择的模拟量输出退出输出为常数值的模式,使输出返回输出跟踪输入的模式。 | msrc_UNKNOWN | 详细信息 |
transmitter_dac_trim | 1024 | D/A修正 | 数字到模拟修正——允许对选择的模拟量输出进行标定,在模拟量输出的操作端点有外部参考。 | msrc_UNKNOWN | 详细信息 |