Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
Restore_Factory_Defaults_menu | 413D | Restore Factory Setting | restore to factory | msrc_UNKNOWN | Details |
trim_pv_zero_flow | 4140 | Trim Zero | msrc_UNKNOWN | Details | |
trim_pv_zero_level | 4141 | Trim Zero | msrc_UNKNOWN | Details | |
trim_pv_zero_temp | 4142 | Trim Zero | msrc_UNKNOWN | Details | |
trim_pv_zero_prss | 4143 | Trim Zero | msrc_UNKNOWN | Details | |
Multipoint_Calibration | 4144 | Multipoint Calibration | Use when PV condition can be independently measured and adjusted for the calibration. Requires prior entry of specific gravity of test fluid(s), volume of displacer and displacer rod length. | msrc_UNKNOWN | Details |
Manual_Calibration | 4145 | Manual Cal intput | Use when PV condition can be independently measured and adjusted for the calibration. Requires prior entry of specific gravity of test fluid(s), volume of displacer and displacer rod length. | msrc_UNKNOWN | Details |
set_zero_4ma | 4146 | Set Zero(4mA) | Sets lower range value (4mA output) to the present internal PV value. Works like a zero control on an analog device- the span between upper and lower range values is preserved, so the URV moves also. This command does not adjust the internal PV calibration vs. the input condition ?Conly the relationship between input condition ?Conly the relationship between internal values and the output current. | msrc_UNKNOWN | Details |
set_span_20ma | 4147 | Set Span(20mA) | Sets upper range value (20mA output) to the present internal PV value. Works like a span control on an analog device ?C the existing lower range value will remain the same, only the span will be changed. This command does not adjust the internal PV calibration vs. the input condition ?C only the relationship between internal PV values and output current. | msrc_UNKNOWN | Details |
Guided_Setup | 4148 | Guided Setup | Guides user through initial configuration and calibration process | msrc_UNKNOWN | Details |
status_display_MENU | 4149 | Status | Reports any PV or temperature alarms that are active | msrc_UNKNOWN | Details |
Trim_procTemp | 414A | Proc Temp cali | msrc_UNKNOWN | Details | |
Densty_coff | 414B | Density Table | Used to select temperature coefficient table for Densty. | msrc_UNKNOWN | Details |
Sensor_setup | 414C | Sensor | Sensor Parameter | msrc_UNKNOWN | Details |
Sensor_Variables | 414D | Sensor | Sensor Parameter | msrc_UNKNOWN | Details |
FlowAcc_Reset | 414E | Reset FlowAcc | msrc_UNKNOWN | Details | |
Trim_SenTemp_zero | 4170 | Sen Temp Zero | msrc_UNKNOWN | Details | |
applied_rerange | 1007 | Apply values | Applied values- Perform a device rerange by applying the desired Upper Range Value and Lower Range Values to the device input | msrc_UNKNOWN | Details |
zero_trim | 1006 | Zero trim | Zero trim- Make the sensor input the new zero input reference | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
warning_message | 1017 | Set loop to manual | msrc_UNKNOWN | Details | |
device_self_test | 1071 | Self test | Self Test- Commands the electronics to perform a self test. | msrc_UNKNOWN | Details |
device_master_reset | 1072 | Device reset | Device Reset- Commands the electronics to perform a reset. This is equivalent to cycling the power off and then back on to the field device. | msrc_UNKNOWN | Details |
transmitter_loop_test | 1023 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
transmitter_dac_trim | 1024 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |