Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
auto_setup_method | 4125 | Auto Setup | "Auto Setup" will automatically configure/calibrate following items. - Zero point (0% Travel Angle) & Span (100% Travel Angle) - Actuator Size & Gland Packing Type - Actuator Action After Auto set up, please check calibration result. You may be required to re-calibrate span so meet specific actuator design. | msrc_UNKNOWN | Details |
dmy_input_sig_method | 4126 | Dummy Input Signal | Dummy input signal applies dummy input signal to the positioner for the functional check. | msrc_UNKNOWN | Details |
dmy_drive_sig_method | 4127 | Dummy Drive Signal | Dummy drive signal applies dummy drive signal to the positioner for the functional check. | msrc_UNKNOWN | Details |
loop_test_method | 4128 | Loop Test | Loop test outputs dummy analog output from the AVP307 to upper system for the functional check. | msrc_UNKNOWN | Details |
user_data_save_method | 4129 | Save current settings | "Save current settings" will save current setting data to the internal back up memory of the positioner. | msrc_UNKNOWN | Details |
reset_correct_method | 412A | Load saved settings | Configuration data is reset at the time of shipment. | msrc_UNKNOWN | Details |
actuator_size_method | 412B | Change Actuator Size | Actuator size parameter will be changed. | msrc_UNKNOWN | Details |
gland_packing_method | 412C | Change Gland Packing Type | Gland packing type parameter will be changed. | msrc_UNKNOWN | Details |
calibrate_4mA_method | 412D | Calibrate 4mA | "Calibrate 4mA" will calibrate 4mA signal that the positioner recognizes to the standard 4mA signal or actual controller output. | msrc_UNKNOWN | Details |
calibrate_20mA_method | 412E | Calibrate 20mA | "Calibrate 20mA" will calibrate 20mA signal that the positioner recognizes to the standard 20mA signal or actual controller output. | msrc_UNKNOWN | Details |
angle_adjust_method | 412F | Angle Adjustment | Angle adjustment is the method to calibrate zero/span by designating correction angle to preset 0% or 100% travel angle. | msrc_UNKNOWN | Details |
manual_adjust_method | 4130 | Manual Adjustment | Manual adjustment is the method to calibrate zero/span by designating actual valve close or open position. | msrc_UNKNOWN | Details |
da_trim_method | 4131 | D/A Trim | "D/A Trim" will calibrate travel transmission analog output signal. | msrc_UNKNOWN | Details |
abort_da_trim_method1 | 4132 | msrc_UNKNOWN | Details | ||
abort_da_trim_method2 | 4133 | msrc_UNKNOWN | Details | ||
dp_stick_slip_count_clear_method | 4134 | Clear Stick Slip Count | Stick slip count parameter will be cleared. | msrc_UNKNOWN | Details |
dp_max_travel_data_clear_method | 4135 | Clear Max Tvl Speed | Max tvl speed parameters will be cleared. | msrc_UNKNOWN | Details |
clear_travel_histogram_method | 4136 | Clear Travel Histogram | Travel histogram parameters will be cleared. | msrc_UNKNOWN | Details |
change_inst_mode_method | 4137 | Change Mode | Mode parameter will be changed. | msrc_UNKNOWN | Details |
update_stick_slip_method | 4138 | Update Stick Slip | Stick slip parameters will be updated. | msrc_UNKNOWN | Details |
update_total_stroke_method | 4139 | Update Total Stroke | Total stroke parameter will be updated. | msrc_UNKNOWN | Details |
update_cycle_count_method | 413A | Update Cycle Count | Cycle count parameter will be updated. | msrc_UNKNOWN | Details |
update_travel_histogram_method | 413B | Update Travel Histogram | Travel histogram parameters will be updated. | msrc_UNKNOWN | Details |
update_shutoff_count_method | 413C | Update Shut-Off Count | Shut-Off count parameter will be updated. | msrc_UNKNOWN | Details |
update_max_tvl_speed_method | 413D | Update Max Tvl Speed | Max tvl speed parameters will be updated. | msrc_UNKNOWN | Details |
update_diag_param_method | 413E | Update | Diagnostic parameters will be updated. | msrc_UNKNOWN | Details |