Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
before_poll | 4000 | Before polling | msrc_UNKNOWN | Details | |
put_in_manual | 4061 | Loop in manual | msrc_UNKNOWN | Details | |
back_to_normal | 4062 | Back to normal | msrc_UNKNOWN | Details | |
read_max_min | 4044 | Read max/min log | Reads the maximum and minimum logged values | msrc_UNKNOWN | Details |
reset_max_min | 4045 | Reset max/min log | Resets the maximum and minimum logged values | msrc_UNKNOWN | Details |
enter_sensor_configuration | 4047 | Sensor config | Configures the sensor, sensor type, measurement type, CJC compensation etc. | msrc_UNKNOWN | Details |
enter_cable_resistance | 4049 | Enter value | Enter new value for cable resistance. If the device setup is RTD/Ohm 3 or 4 wire, cable resistance for sensor 1 is the expected max value for the total cable resistance in 2 wires. Otherwise it is the actual total cable resistance for the selected sensor | msrc_UNKNOWN | Details |
measure_cable_resistance | 404A | Measure value | Automaticly measures the cable resistance. If the device setup is RTD/Ohm 3 or 4 wire, cable resistance for sensor 1 is the expected max value for the total cable resistance in 2 wires. Otherwise it is the actual total cable resistance for the selected sensor | msrc_UNKNOWN | Details |
restore_configuration | 4063 | restoring configuration | msrc_UNKNOWN | Details | |
broken_namur_down | 4059 | NAMUR down | Sets the broken sensor output value to 3.5 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
broken_namur_up | 405A | NAMUR up | Sets the broken sensor output value to 23 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
shorted_namur_down | 405B | NAMUR down | Sets the shorted sensor output value to 3.5 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
shorted_namur_up | 405C | NAMUR up | Sets the shorted sensor output value to 23 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
set_output_limits_namur | 4056 | Set limits = NAMUR | Sets the analog output limits to 3.8 mA and 20.5 mA acc. to NAMUR NE43 | msrc_UNKNOWN | Details |
override_dac_trim | 4046 | Factory D/A trim | Overrides any previously D/A trimming by restoring factory calibration values | msrc_UNKNOWN | Details |
loop_test | 1002 | Loop test | Loop test- Allows the User to manually manipulate the Analog Output to a selected constant output value | msrc_UNKNOWN | Details |
dac_trim | 1004 | D/A trim | Digital to Analog Trim- Allows the calibration of a selected Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
scaled_dac_trim | 1005 | Scaled D/A trim | Digital to Analog Scaled Trim- Allows the calibration of the Analog Output with an external reference at the operating endpoints of the Analog Output | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | Leaving fixed crnt mode | Leaving Fixed Current Mode- Takes the Analog Output out of a mode where the output was a constant value, and returns the output to a mode where the output tracks the input | msrc_UNKNOWN | Details |
return_to_normal | 1016 | Aborting return to normal | msrc_UNKNOWN | Details | |
Name | ID | Label | Description | Type | Source |