Method Name: enter_sensor_configuration

Method ID: 0x4047

Method Label: Sensor config

Method Help: Configures the sensor, sensor type, measurement type, CJC compensation etc.


  • {
  • char status[3];
  • char disp_string1[60];
  • int choice;
  • int val_flag;
  • int slen1;
  • long varid[4];
  • _set_all_resp_code(0);
  • slen1 = 60;
  • _get_dictionary_string(19726337,disp_string1,slen1);
  • ACKNOWLEDGE(disp_string1);
  • _add_abort_method(4118);
  • send(140,status);
  • if (status[0])
  • {
  • display_response_status(140,status[0]);
  • process_abort();
  • }
  • _get_dev_var_value(literal_string(247),0,16406);
  • switch (_ivar_value(16406))
  • {
  • case 0:
  • _iassign(16385,37);
  • break;
  • case 128:
  • _iassign(16385,36);
  • break;
  • default:
  • _get_dev_var_value(literal_string(248),0,16385);
  • }