Loading…
Loading…
Name | ID | Label | Description | Type | Source |
---|---|---|---|---|---|
factory_sensor_trim | 4093 | Factory trim | Sensor Factory trim method - The factory trimming is a reset to the values used in the factory for the trimming operation and can be usually done without the need of external equipment. | msrc_UNKNOWN | Details |
coefb2_to_0100 | 40B1 | Put coeff b2 into range 0-100 | msrc_UNKNOWN | Details | |
coefb2_to_01 | 40B2 | Put coeff b2 into range 0-1 | msrc_UNKNOWN | Details | |
coefb0_to_0100 | 40B3 | Put coeff b0 into range 0-100 | msrc_UNKNOWN | Details | |
coefb0_to_01 | 40B4 | Put coeff b0 into range 0-1 | msrc_UNKNOWN | Details | |
coefa2_to_0100 | 40B5 | Put coeff a2 into range 0-100 | msrc_UNKNOWN | Details | |
coefa2_to_01 | 40B6 | Put coeff a2 into range 0-1 | msrc_UNKNOWN | Details | |
coefa0_to_0100 | 40B7 | Put coeff a0 into range 0-100 | msrc_UNKNOWN | Details | |
coefa0_to_01 | 40B8 | Put coeff a0 into range 0-1 | msrc_UNKNOWN | Details | |
limit_to_0100 | 40AD | Put limit double coeff into range 0-100% | msrc_UNKNOWN | Details | |
limit_to_01 | 40AE | Put limit double coeff into range 0-1 | msrc_UNKNOWN | Details | |
output_perc_low | 40A5 | Set OP % Low | Set OP % Low method - The OP % is set to the inserted valueLow range will be related to this value | msrc_UNKNOWN | Details |
output_perc_high | 40A6 | Set OP Perc High | Set OP Perc High method - The OP Perc is set to the inserted valueHigh range will be related to this value | msrc_UNKNOWN | Details |
pv_scaling_reset | 40A7 | PV Bias Reset | PV Scaling Reset method - The PV Scaling condition is reset | msrc_UNKNOWN | Details |
pv_scaling_setpvzero | 40A8 | Set PV Zero | Set PV Zero method - The PV Scaling condition is a reset | msrc_UNKNOWN | Details |
pv_scaling_setpvval | 40A9 | Set PV Val | Set PV Value method - The PV Scaling condition is setTo the inserted value | msrc_UNKNOWN | Details |
EN_zero_trim | 40A0 | ゼロ トリム | ゼロ トリム - センサーに基準ゼロを入力して補正します。 | msrc_UNKNOWN | Details |
EN_full_trim | 40A1 | Full trim | Full trim method - The full trimming allows the performance of high or low trim. | msrc_UNKNOWN | Details |
loop_test | 1002 | ループ テスト | ループ テスト - アナログ出力をユーザーが選択した値で固定出力します | msrc_UNKNOWN | Details |
dac_trim | 1004 | D/A トリム | D/A トリム (デジタル/アナログ トリム) - オペレーティング エンド ポイントに対するアナログ出力と外部指示計とのキャリブレーションを行います。 | msrc_UNKNOWN | Details |
scaled_dac_trim | 1005 | スケーリング D/A トリム | スケーリング D/A トリム - オペレーティング エンド ポイントに対する選択したアナログ出力と外部指示系とのキャリブレーションを行います。 | msrc_UNKNOWN | Details |
leave_fixed_current_mode | 1003 | 固定電流モードを終ります | 現在の固定モードを終了 - アナログ出力を定数値のモードから移行させ, 出力が入力に応じて変わるモードに戻します。 | msrc_UNKNOWN | Details |
return_to_normal | 1016 | ノーマル モードに戻します | msrc_UNKNOWN | Details | |
send_warning | 1399 | Send warning | Send Warning- Yields a units code notice to the User. | msrc_UNKNOWN | Details |
back_to_normal | 4017 | Back to normal | msrc_UNKNOWN | Details | |
back_to_normal_with_msg | 4004 | Back to normal with msg | msrc_UNKNOWN | Details | |
factory_trim | 4073 | Factory trim | Factory trim method - The factory trimming is a reset to the values used in the factory for the trimming operation and can be usually done without the need of external equipment. | msrc_UNKNOWN | Details |
static_trim | 4070 | Static trim | Static trim method - The static trimming allows a single point trim of Static Pressure | msrc_UNKNOWN | Details |
set_four_twenty_ma | 406C | Rerange 4-20mA | Perform a device rerange to 4 - 20ma by applying source pressure input. | msrc_UNKNOWN | Details |
coef0_to_0100 | 4034 | Put coef0 into range 0-100 | msrc_UNKNOWN | Details | |
coef2_to_0100 | 4030 | Put coef2 into range 0-100 | msrc_UNKNOWN | Details | |
coef3_to_0100 | 402D | Put coef3 into range 0-100 | msrc_UNKNOWN | Details | |
coef4_to_0100 | 402A | Put coef4 into range 0-100 | msrc_UNKNOWN | Details | |
coef5_to_0100 | 4027 | Put coef5 into range 0-100 | msrc_UNKNOWN | Details | |
coef0_to_01 | 4035 | Put coef0 into range 0-1 | msrc_UNKNOWN | Details | |
coef2_to_01 | 4031 | Put coef2 into range 0-1 | msrc_UNKNOWN | Details | |
coef3_to_01 | 402E | Put coef3 into range 0-1 | msrc_UNKNOWN | Details | |
coef4_to_01 | 402B | Put coef4 into range 0-1 | msrc_UNKNOWN | Details | |
coef5_to_01 | 4028 | Put coef5 into range 0-1 | msrc_UNKNOWN | Details | |
danger_max | 4021 | Danger for max working pressure | msrc_UNKNOWN | Details | |
put_in_manual | 4003 | Loop in manual | msrc_UNKNOWN | Details | |
before_poll | 4000 | Before polling | msrc_UNKNOWN | Details | |
self_test | 406E | セルフ テスト | Commands the DPK pressure electronics to perform a selftest. | msrc_UNKNOWN | Details |
Name | ID | Label | Description | Type | Source |