0 |
AXFA11 |
1 |
AXFA14 |
2 |
10:uP Fault |
3 |
11:EEPROM Fault |
4 |
12:A/D(H) Fault |
5 |
13:A/D(L) Fault |
6 |
14:A/D(Z) Fault |
7 |
15:Coil Open |
8 |
16:EEPROM Dflt |
9 |
|
10 |
30:Sig Overflow |
11 |
31:Empty Pipe |
12 |
32:HH/LL Alm |
13 |
33:Adhesion Alm |
14 |
34:Insu-Brk Alm |
15 |
50:Span > 10m/s |
16 |
51:Span < 0.1m/s |
17 |
52:TTL>10000p/s |
18 |
53:TTL<0.0001p/s |
19 |
54:4-20 Lmt Err |
20 |
55:Multi Rng Err |
21 |
56:H/L HH/LL Set |
22 |
57:Dens Set Err |
23 |
60:PLS>10000p/s |
24 |
61:PLS > 5000p/s |
25 |
62:PLS > 1000p/s |
26 |
63:PLS > 500p/s |
27 |
64:PLS > 25p/s |
28 |
65:PLS > 15p/s |
29 |
66:PLS > 10p/s |
30 |
67:PLS > 5p/s |
31 |
70:PLS<0.0001p/s |
32 |
71:Meas Mod Set |
33 |
72:Size Set Err |
34 |
73:Adh Set Err |
35 |
80:Adhesion Wng |
36 |
81:Insu-Brk Wng |
37 |
82:Auto Zero Wng |
38 |
83:Fix Cur Wng |
39 |
84:Disp Over Wng |
40 |
Reverse Totl |
41 |
Dif Totl |
42 |
Flow Sensor- Hardware that measures flow rate. |
43 |
.0f |
44 |
.1f |
45 |
.2f |
46 |
.3f |
47 |
g |
48 |
PV AO |
49 |
6.3f |
50 |
Dummy float value |
51 |
Dummy Integer3 Value |
52 |
8d |
53 |
4-20mA Burn Out |
54 |
High |
55 |
Low |
56 |
Dummy transfer function |
57 |
PV Span |
58 |
Sets flow rate span (with units from "Base Flow Unit" and "Base Time Unit"). |
59 |
6g |
60 |
PV Damping |
61 |
5.1f |
62 |
Displays the totalized value for flow rate in the forward direction. |
63 |
Total units |
64 |
Total units- Engineering units that the frequency and totalizer outputs will be displayed with |
65 |
Total Value- Total of forward flow value. |
66 |
Total Unit |
67 |
.4f |
68 |
.5f |
69 |
.6f |
70 |
.7f |
71 |
Displays the totalized value for flow rate in the reverse direction. |
72 |
Reverse total units |
73 |
Reverse total units- Engineering units that the reverse total will be displayed with |
74 |
Reverse total Value- Total of reverse flow value. |
75 |
Reverse Totl Units |
76 |
Displays the totalized value for flow rate between forward totalization and reverse totalization. |
77 |
Differencial total units |
78 |
Differential total units- Engineering units that the differential total will be displayed with |
79 |
Differential total Value- Difference between total and reverse total. |
80 |
Dif Totl Units |
81 |
Select Flow Tube |
82 |
Selects the flowtube's model name. |
83 |
ADMAG AXF |
84 |
ADMAG |
85 |
ADMAG AE |
86 |
ADMAG SE |
87 |
YEWMAG |
88 |
Calibrator |
89 |
Other |
90 |
Nominal Size Unit |
91 |
Selects the nominal size units for the flowtube. |
92 |
mm |
93 |
inch |
94 |
Nominal Size |
95 |
Sets flowtube nominal size in selected unit at "Nominal Size Unit". |
96 |
7.2f |
97 |
6.2f |
98 |
7g |
99 |
Measure Mode |
100 |
Selects measurement mode for dual frequency excitation. |
101 |
Standard DF |
102 |
Enhanced DF |
103 |
Low MF |
104 |
Sets low-frequency meter factor for standard dual frequency excitation. |
105 |
6.4f |
106 |
High MF |
107 |
Sets high-frequency meter factor for standard dual frequency excitation. |
108 |
Low MF(EDF) |
109 |
Sets low-frequency meter factor for enhanced dual frequency excitation. |
110 |
High MF(EDF) |
111 |
Sets high-frequency meter factor for enhanced dual frequency excitation. |
112 |
Span Unit |
113 |
Ml/d |
114 |
m3/d |
115 |
kl/d |
116 |
l/d |
117 |
cm3/d |
118 |
m/d |
119 |
t/d |
120 |
kg/d |
121 |
g/d |
122 |
kcf/d |
123 |
cf/d |
124 |
mcf/d |
125 |
Mgal/d |
126 |
kgal/d |
127 |
gal/d |
128 |
mgal/d |
129 |
kbbl/d |
130 |
bbl/d |
131 |
mbbl/d |
132 |
ubbl/d |
133 |
ft/d |
134 |
klb/d |
135 |
lb/d |
136 |
Ml/h |
137 |
m3/h |
138 |
kl/h |
139 |
l/h |
140 |
cm3/h |
141 |
m/h |
142 |
t/h |
143 |
kg/h |
144 |
g/h |
145 |
kcf/h |
146 |
cf/h |
147 |
mcf/h |
148 |
Mgal/h |
149 |
kgal/h |
150 |
gal/h |
151 |
mgal/h |
152 |
kbbl/h |
153 |
bbl/h |
154 |
mbbl/h |
155 |
ubbl/h |
156 |
ft/h |
157 |
klb/h |
158 |
lb/h |
159 |
Ml/min |
160 |
m3/min |
161 |
kl/min |
162 |
l/min |
163 |
cm3/min |
164 |
m/min |
165 |
t/min |
166 |
kg/min |
167 |
g/min |
168 |
kcf/min |
169 |
cf/min |
170 |
mcf/min |
171 |
Mgal/min |
172 |
kgal/min |
173 |
gal/min |
174 |
mgal/min |
175 |
kbbl/min |
176 |
bbl/min |
177 |
mbbl/min |
178 |
ubbl/min |
179 |
ft/min |
180 |
klb/min |
181 |
lb/min |
182 |
Ml/s |
183 |
m3/s |
184 |
kl/s |
185 |
l/s |
186 |
cm3/s |
187 |
m/s |
188 |
t/s |
189 |
kg/s |
190 |
g/s |
191 |
kcf/s |
192 |
cf/s |
193 |
mcf/s |
194 |
Mgal/s |
195 |
kgal/s |
196 |
gal/s |
197 |
mgal/s |
198 |
kbbl/s |
199 |
bbl/s |
200 |
mbbl/s |
201 |
ubbl/s |
202 |
ft/s |
203 |
klb/s |
204 |
lb/s |
205 |
Base Flow Unit |
206 |
Selects flow units for the flow rate span. |
207 |
Ml(Megaliter) |
208 |
m3 |
209 |
kl(Kiloliter) |
210 |
l(Liter) |
211 |
cm3 |
212 |
m |
213 |
t |
214 |
kg |
215 |
kcf |
216 |
cf |
217 |
mcf |
218 |
Mgal(US) |
219 |
kgal(US) |
220 |
gal(US) |
221 |
mgal(US) |
222 |
kbbl(US Oil) |
223 |
bbl(US Oil) |
224 |
mbbl(US Oil) |
225 |
ubbl(US Oil) |
226 |
kbbl(US Beer) |
227 |
bbl(US Beer) |
228 |
mbbl(US Beer) |
229 |
ubbl(US Beer) |
230 |
ft |
231 |
klb(US) |
232 |
lb(US) |
233 |
Base Time Unit |
234 |
Selects time units for the flow rate span. |
235 |
/d |
236 |
/h |
237 |
/min |
238 |
/s |
239 |
Flow Decimal Pnt |
240 |
Selects decimal point position for the display unit's instantaneous flow rate. |
241 |
Auto |
242 |
0 |
243 |
1 |
244 |
2 |
245 |
3 |
246 |
Density Unit |
247 |
Sets units for density when mass flow rate is selected. |
248 |
kg/m3 |
249 |
lb/gal |
250 |
lb/cf |
251 |
Mass Flow Density |
252 |
Sets density when mass flow rate is selected (with units from "Density Unit"). |
253 |
User Span Select |
254 |
Selects whether or not special units are used as flow rate units. |
255 |
No |
256 |
Yes |
257 |
Flow User Unit |
258 |
Sets the special flow rate units. |
259 |
Flow User Span |
260 |
Sets span when using special flow rate units. |
261 |
4-20mA Low Cut |
262 |
% |
263 |
Sets the range in vicinity of 0 % within which the current output will be 4 mA. |
264 |
2.0f |
265 |
4-20mA Low Lmt |
266 |
Sets the low limit for current output. |
267 |
4-20mA High Lmt |
268 |
Sets the high limit for current output. |
269 |
Velocity Check |
270 |
Display of the span setting using flow velocity (m/s). |
271 |
Magflow Zero |
272 |
Displays the result of the automatic zero adjustment, or sets the zero point. |
273 |
7.3f |
274 |
Autozero Time |
275 |
3d |
276 |
Auto Zero Exe |
277 |
Selects whether or not automatic zero adjustment is carried out. |
278 |
No Execution |
279 |
Execution |
280 |
Display Select1 |
281 |
Selects content of the first line for Display Mode. |
282 |
Flow Rate(%) |
283 |
Flow Rate |
284 |
Flow Rate(mA) |
285 |
Forward Total |
286 |
Reverse Total |
287 |
Dif Total |
288 |
Display Select2 |
289 |
Selects content of the second line for Display Mode. |
290 |
Off |
291 |
Flow Rate(Bar) |
292 |
Tag No |
293 |
Adhesion Check |
294 |
Communication |
295 |
Display Select3 |
296 |
Selects content of the third line for Display Mode. |
297 |
Display Cycle |
298 |
Selects the display cycle. |
299 |
200ms |
300 |
400ms |
301 |
1s |
302 |
2s |
303 |
4s |
304 |
8s |
305 |
LCD Contrast |
306 |
2d |
307 |
Language |
308 |
Selects the language used for the display unit. |
309 |
English |
310 |
Japanese |
311 |
French |
312 |
German |
313 |
Italian |
314 |
Spanish |
315 |
Selects the flow rate unit per one pulse as used for totalization display. |
316 |
n Unit/P |
317 |
u Unit/P |
318 |
m Unit/P |
319 |
Unit/P |
320 |
k Unit/P |
321 |
M Unit/P |
322 |
Pulse/s |
323 |
Total Scale |
324 |
Sets the flow rate per one pulse as used for totalization display. |
325 |
Total Execution |
326 |
Executes "Start" or "Stop" of the totalization function, or executes "Preset Total" or "Preset Rev Total". |
327 |
Start |
328 |
Stop |
329 |
Preset Total |
330 |
Preset Rev Total |
331 |
Total Low Cut |
332 |
Sets the range in vicinity of 0% within which the totalization display will be halted. |
333 |
3.0f |
334 |
Ttl Set Val Upper |
335 |
Sets the totalization preset value in the upper 2 digits of the 8-digit totalized value. |
336 |
Ttl Set Val Lower |
337 |
Sets the totalization preset value in the lower 6 digits of the 8-digit totalized value. |
338 |
6d |
339 |
Ttl Switch Upper |
340 |
Sets the totalization switch value in the upper 2 digits of the 8-digit totalized value. |
341 |
Ttl Switch Lower |
342 |
Sets the totalization switch value in the lower 6 digits of the 8-digit totalized value. |
343 |
Ttl User Select |
344 |
Selects whether or not special units are used as totalized units. |
345 |
Ttl User Unit |
346 |
Sets the special totalized units. |
347 |
Total Decimal Pnt |
348 |
Selects position of decimal point for totalization display. |
349 |
4 |
350 |
5 |
351 |
6 |
352 |
7 |
353 |
Pulse Unit |
354 |
Selects the flow rate unit per one pulse as used for pulse output. |
355 |
Pulse Scale |
356 |
Sets the flow rate per one pulse as used for pulse output. |
357 |
Pulse Low Cut |
358 |
Sets the range in vicinity of 0% within which pulse output will be halted. |
359 |
Pulse Width |
360 |
Selects the pulse width for pulse output. |
361 |
50% Duty |
362 |
0.05 ms |
363 |
0.1 ms |
364 |
0.5 ms |
365 |
1 ms |
366 |
20 ms |
367 |
33 ms |
368 |
50 ms |
369 |
100 ms |
370 |
Pulse Active Mode |
371 |
Closed(On) Act |
372 |
Open(Off) Act |
373 |
T/P Damp Select |
374 |
Selects whether the flow rate value obtained through damping calculation for total/pulse or the instantaneous flow rate value (no damping) for total/pulse is to be used. |
375 |
Damping |
376 |
No Damping |
377 |
Flow Direction |
378 |
Selects the flow direction. |
379 |
Forward |
380 |
Reverse |
381 |
Rate Limit |
382 |
Sets the level to reduce output fluctuation. |
383 |
Dead Time |
384 |
Sets the dead time to reduce output fluctuation. When "0" is set, rate limit function is not available. |
385 |
Power Synch |
386 |
Selects whether or not the internal frequency is to be synchronized with the power supply frequency. |
387 |
Power Frequency |
388 |
Displays the power-supply frequency (for Power Synch = "Yes"), or sets the power-supply frequency (for Power Synch = "No"). |
389 |
5.2f |
390 |
Pulsing Flow |
391 |
Selects whether pulsing flow is to be supported. |
392 |
Low Low Alarm |
393 |
Sets level setting value for low-low flow rate limit (LL). |
394 |
4.0f |
395 |
Low Alarm |
396 |
Sets level setting value for low flow rate limit (L). |
397 |
H/L Alarm Hys |
398 |
Sets hysteresis width for high-low flow rate limit alarm. |
399 |
High High Alarm |
400 |
Sets level setting value for high-high flow rate limit (HH). |
401 |
High Alarm |
402 |
Sets level setting value for high flow rate limit (H). |
403 |
Alm Out Act Mode |
404 |
Selects whether alarm output will be set to "On Active" or "Off Active". |
405 |
Close(On) Act |
406 |
Alm-Setting |
407 |
Selects whether a setting alarm is to be specified as an alarm. |
408 |
Alm-Adhesion |
409 |
Selects whether an electrode adhesion alarm is to be specified as an alarm. |
410 |
Alm-Emp Pipe |
411 |
Selects whether an empty pipe alarm is to be specified as an alarm. |
412 |
Alm-Sig Over |
413 |
Selects whether a signal overflow alarm is to be specified as an alarm. |
414 |
Alm-HH/LL |
415 |
Selects whether a flow rate high-high or low-low alarm is to be specified as an alarm. |
416 |
4-20mA Alarm Out |
417 |
Selects the current output during alarm occurrence. |
418 |
2.4mA or Less |
419 |
4.0mA |
420 |
Hold |
421 |
21.6mA or More |
422 |
Operation Time |
423 |
Displays the operation time. |
424 |
Alm Record1 |
425 |
Displays the content of the most recent alarm. |
426 |
|
427 |
18:Power Off |
428 |
19:Inst Pwr Fail |
429 |
28:WDT |
430 |
34 Insulation Al |
431 |
Alm Record Time1 |
432 |
Displays the operation time at the occurrence of the most recent alarm. |
433 |
Alm Record2 |
434 |
Displays the content of the second most recent alarm. |
435 |
Alm Record Time2 |
436 |
Displays the operation time at occurrence of the second most recent alarm. |
437 |
Alm Record3 |
438 |
Displays the content of the third most recent alarm. |
439 |
Alm Record Time3 |
440 |
Displays the operation time at the occurrence of the third most recent alarm. |
441 |
Alm Record4 |
442 |
Displays the content of the fourth most recent alarm. |
443 |
Alm Record Time4 |
444 |
Displays the operation time at the occurrence of the fourth most recent alarm. |
445 |
SO1 Function |
446 |
Selects function for the SO1 terminal. |
447 |
No Function |
448 |
Warning Output |
449 |
Total Switch |
450 |
H/L Alarm |
451 |
HH/LL Alarm |
452 |
Fwd/Rev Ranges |
453 |
Auto 2 Ranges |
454 |
Auto 3 Ranges |
455 |
Auto 4 Ranges |
456 |
Ext 2 Answer |
457 |
Ext 3 Answer |
458 |
Ext 4 Answer |
459 |
SO2 Function |
460 |
Selects function for the SO2 terminal. |
461 |
SI1 Function |
462 |
Selects function for the SI1 terminal. |
463 |
0% Signal Lock |
464 |
Ext Auto Zero |
465 |
Ext Ttl Preset |
466 |
Ext Rev Ttl Set |
467 |
Ext 2 Ranges |
468 |
Ext 3 Ranges |
469 |
Ext 4 Ranges |
470 |
SI2 Function |
471 |
Selects function for the SI2 terminal. |
472 |
SO1/2 Active Mode |
473 |
Selects whether SO1/SO2 output will be set to "On Active" or "Off Active". |
474 |
SI1/2 Active Mode |
475 |
Selects whether SI1/SI2 input will be set to "Short Active" or "Open Active". |
476 |
Short Active |
477 |
Open Active |
478 |
DO Function |
479 |
Pulse Output |
480 |
Alarm Output |
481 |
Total Switch(O) |
482 |
H/L Alarm(O) |
483 |
HH/LL Alarm(O) |
484 |
Fwd/Rev Rngs(O) |
485 |
Auto 2 Rngs(O) |
486 |
Auto 3 Rngs(O) |
487 |
Auto 4 Rngs(O) |
488 |
Ext 2 Answer(O) |
489 |
DIO Function |
490 |
0% Sgnl Lock(I) |
491 |
Ext Auto Zero(I) |
492 |
Ext Ttl Set(I) |
493 |
Ext R Ttl Set(I) |
494 |
Ext 2 Ranges(I) |
495 |
DO Active Mode |
496 |
DIO Active Mode |
497 |
Closed/Short Act |
498 |
Open/Open Act |
499 |
Forward Span2 |
500 |
Sets flow rate span for forward No. 2 range. |
501 |
Forward Span3 |
502 |
Sets flow rate span for forward No. 3 range. |
503 |
Forward Span4 |
504 |
Sets flow rate span for forward No. 4 range. |
505 |
Auto Range Hys |
506 |
Sets hysteresis width for automatic range switching. |
507 |
Reverse Span1 |
508 |
Sets flow rate span for reverse No. 1 range. |
509 |
Reverse Span2 |
510 |
Sets flow rate span for reverse No. 2 range |
511 |
Reverse Span3 |
512 |
Sets flow rate span for reverse No. 3 range. |
513 |
Reverse Span4 |
514 |
Sets flow rate span for reverse No. 4 range |
515 |
Bi Direction Hys |
516 |
Sets hysteresis width for forward/reverse switching. |
517 |
1.0f |
518 |
Process Connect |
519 |
Selects the process connection of flowtube. |
520 |
No Set |
521 |
ANSI 150 Wafer |
522 |
ANSI 300 Wafer |
523 |
DIN PN10 Wafer |
524 |
DIN PN16 Wafer |
525 |
DIN PN40 Wafer |
526 |
JIS 10K Wafer |
527 |
JIS 20K Wafer |
528 |
JIS F12 Wafer |
529 |
ANSI 150 Flange |
530 |
ANSI 300 Flange |
531 |
DIN PN10 Flange |
532 |
DIN PN16 Flange |
533 |
DIN PN40 Flange |
534 |
JIS 10K Flange |
535 |
JIS 20K Flange |
536 |
JIS F12 Flange |
537 |
Union (Weld Jnt) |
538 |
Union (NPT Male) |
539 |
Union (R Male) |
540 |
Lining |
541 |
Selects the lining of flowtube. |
542 |
Flourocarbon PFA |
543 |
Polyurethane |
544 |
Ceramics |
545 |
EPDM |
546 |
Natural Rubber |
547 |
Electrode Material |
548 |
Selects the electrode material of flowtube. |
549 |
316L SS/1.4404 |
550 |
Platinum-iridium |
551 |
Platinum-alumina |
552 |
Hastelloy C276 |
553 |
Tantalum |
554 |
Titanium |
555 |
Tungsten Carbide |
556 |
Grounding Ring |
557 |
Selects the grounding ring of flowtube. |
558 |
None |
559 |
316 SS/1.4401 |
560 |
Use |
561 |
Selects the use of flowtube. |
562 |
General Purpose |
563 |
Submersible |
564 |
Ex-Proof |
565 |
Sanitary |
566 |
Lay Length |
567 |
Selects the lay length of flowtube. |
568 |
Standard |
569 |
ADMAG Replace |
570 |
Electrical Conn |
571 |
Selects the electrical connection of flowtube. |
572 |
JIS G1/2 Female |
573 |
ANSI 1/2 Female |
574 |
ISO M20 Female |
575 |
Electrode Struct |
576 |
Selects the electrode structure of flowtube. |
577 |
Non-replaceable |
578 |
Replaceable |
579 |
Software Rev No |
580 |
Software revision number |
581 |
Sensor Serial No |
582 |
The sensor serial number of flowtube. |
583 |
Test Mode |
584 |
Selects whether mode will be set to "Normal" or "Test". |
585 |
Normal |
586 |
Test |
587 |
Test SO1 |
588 |
Selects the test condition for SO1 terminal. |
589 |
Open(Off) |
590 |
Closed(On) |
591 |
Test SO2 |
592 |
Selects the test condition for SO2 terminal. |
593 |
Test Alarm Out |
594 |
Selects the test condition for alarm output terminal. |
595 |
Test SI1 |
596 |
Displays the test condition for SI1 terminal. |
597 |
Open |
598 |
Short |
599 |
Test SI2 |
600 |
Displays the test condition for SI2 terminal. |
601 |
Test DO |
602 |
Pulse |
603 |
Test DIO(O) |
604 |
Input Mode |
605 |
Test DIO(I) |
606 |
Open(Off) |
607 |
Percent Unit |
608 |
% |
609 |
% [F1] |
610 |
% [F2] |
611 |
% [F3] |
612 |
% [F4] |
613 |
% [R1] |
614 |
% [R2] |
615 |
% [R3] |
616 |
% [R4] |
617 |
Displays the instantaneous flow rate for the span as a percentage. |
618 |
Flow Unit |
619 |
spcl |
620 |
Displays the instantaneous flow rate for the span as a current output value. |
621 |
Displays the actual reading for instantaneous flow rate. |
622 |
PV AO Unit |
623 |
mA |
624 |
mA [F1] |
625 |
mA [F2] |
626 |
mA [F3] |
627 |
mA [F4] |
628 |
mA [R1] |
629 |
mA [R2] |
630 |
mA [R3] |
631 |
mA [R4] |
632 |
Memo 1 |
633 |
Memo field 1 |
634 |
Memo 2 |
635 |
Memo field 2 |
636 |
Memo 3 |
637 |
Memo field 3 |
638 |
Selects whether or not to perform diagnosis of adhesion to the electrode. |
639 |
Adhesion Level1 |
640 |
Sets the resistance value for adhesion Level1 to the electrode. |
641 |
M ohm |
642 |
Adhesion Level2 |
643 |
Sets the resistance value for adhesion Level2 to the electrode. |
644 |
Adhesion Level3 |
645 |
Sets the resistance value for adhesion Level3 to the electrode. |
646 |
Adhesion Level4 |
647 |
Sets the resistance value for adhesion Level4 to the electrode. |
648 |
Adh Measure Value |
649 |
Displays the resistance value for adhesion to the electrode. |
650 |
Software Seal |
651 |
Displays whether or not a Joker password was used (Break). |
652 |
Break |
653 |
Keep |
654 |
Enable Wrt 10min |
655 |
Sets the correct password so that write protection function will be released. |
656 |
New Password |
657 |
Sets the password for write protection function. |
658 |
Not Write Protect Mode |
659 |
The 1st sequence for Xmtr (Mismatch sequence?) |
660 |
Commands the AXFA11 electronics to perform a selftest. Reports any errors that occured. |
661 |
MF Set |
662 |
Sets the high and low-frequency meter factors for "Standard DF" or "Enhanced DF". |
663 |
When the correct password is input, write protection will be released for a period of 10 minutes. |
664 |
Changes the password for write protection. |
665 |
Aborting |
666 |
Exiting |
667 |
Wrt Protect Menu |
668 |
Device Setup |
669 |
Process Variables |
670 |
Diag/Service |
671 |
Test/Status |
672 |
Status |
673 |
Adjustment |
674 |
Output Test |
675 |
Diagnosis |
676 |
Easy Setup |
677 |
Detailed Setup |
678 |
Basic Setup |
679 |
Total |
680 |
Function Set |
681 |
Status Function |
682 |
Alarm |
683 |
Alm Record |
684 |
Display Set |
685 |
Aux |
686 |
HART Output |
687 |
Device Info |
688 |
Field Device Info |
689 |
Model Specific |
690 |
Review |
691 |
Review1 |
692 |
Review2 |
693 |
Review3 |
694 |
Review4 |
695 |
Upload Variables |
696 |
FMU860 |
697 |
DT |
698 |
DVC |
699 |
FCX |
700 |
AS800 |
701 |
340T |
702 |
340C |
703 |
344 |
704 |
Siemens Micro K |
705 |
SITRANS L |
706 |
SIPAN PH |
707 |
SITRANS P |
708 |
75SMT |
709 |
UNIDELTA |
710 |
8320 |
711 |
SX5100 |
712 |
TSV175 |
713 |
DMU |
714 |
3780 |
715 |
BM70 |
716 |
8u |
717 |
low |
718 |
high |
719 |
tmp_av |
720 |
Aborting method due to last error |
721 |
Device maybe stuck in selftest. |
722 |
Self test OK |
723 |
About to enter auto zero |
724 |
The previous error was seen while trying to initiate auto zero. |
725 |
Waiting for auto zero to complete. |
726 |
Auto zero passed |
727 |
Select Measure Mode |
728 |
Input Low MF value |
729 |
Input High MF value |
730 |
Input Low MF(EDF) value |
731 |
Input High MF(EDF) value |
732 |
Measure Mode is invalid selection. |
733 |
Enter current password to enable to write for 10 minutes: |
734 |
Released the write protection for 10 minutes. |
735 |
If you wish to release completely, you have to change password to all of spaces. |
736 |
Enter new password to change state of write protect: |
737 |
Re-enter new password within 30 seconds: |
738 |
Changed to new password. |
739 |
It changed the state of protection related password. |