0 |
ICOT |
1 |
SmartCal |
2 |
Tyco Valves & Controls |
3 |
Alert 0: Cycle Alert |
4 |
Alert 1: Travel Accumulation Alert |
5 |
Alert 2: Travel Alert |
6 |
Alert 3: Deviation Alert |
7 |
Alert 4: Limit switch CLOSED Alert |
8 |
Alert 5: Limit switch OPENED Alert |
9 |
Alert 6: Reserved Alert |
10 |
Alert 7: Reserved Alert |
11 |
Error 0: Reserved error |
12 |
Error 1: Clogged nozzle |
13 |
Error 2: Reserved error |
14 |
Error 3: Low input pressure |
15 |
Error 4: Reserved error |
16 |
Error 5: Integrator Overflow |
17 |
Error 6: Calibration error |
18 |
Error 7: Fugitive emissions detected |
19 |
Refers to the requested position in terms of percent. |
20 |
Setpoint |
21 |
3.1f |
22 |
Refers to the actual valve position in terms of percent. |
23 |
Position |
24 |
Refers to the output pressure of OUT 1 of the positioner in terms of percent. |
25 |
Pressure |
26 |
Setpoint Units |
27 |
Position Units |
28 |
Pressure Units |
29 |
Sensor Units |
30 |
Refers to the requested position in terms of current in mA. |
31 |
Input I |
32 |
2.2f |
33 |
Refers to the actual valve position in terms of current in mA. |
34 |
Output I |
35 |
.3f |
36 |
Refers to the input current to move the valve to full open / close position in normal / reverse operation. |
37 |
FS In |
38 |
Zero In |
39 |
Refers to the output current when the valve is at full open / close position in normal / reverse operation. |
40 |
FS Out |
41 |
Zero Out |
42 |
Sensor Serial |
43 |
Min_Sensor_Span |
44 |
|
45 |
mA Range |
46 |
Flow Type |
47 |
Sensor_Unit |
48 |
Min Span |
49 |
The positioner supports Linear, Quick Opening, and Equal Percentage flow types. |
50 |
Quick opening |
51 |
Flow characteristics is quick opening |
52 |
Equal percentage |
53 |
Flow characteristic is equal percentage |
54 |
Limit Control |
55 |
Limit the valve travel in certain region specified by upper and lower limits. |
56 |
Disable |
57 |
Enable |
58 |
Control Mode |
59 |
Control the valve in either normal or reverse acting mode. |
60 |
Normal |
61 |
Normal Acting Mode |
62 |
Reverse |
63 |
Reverse Acting Mode |
64 |
Display Mode |
65 |
Show %closed or %open on positioner display. |
66 |
%Open |
67 |
Read percentage open |
68 |
%Close |
69 |
Read percentage close |
70 |
Digital Mode |
71 |
When enabled, the positioner will ignore 4 to 20 mA input signal, and allows control to be applied digitaly. |
72 |
Cutoff Mode |
73 |
When enabled, the positioner will apply a larger than necessary close control signal to the valve |
74 |
Valve Type |
75 |
Positioner can work with linear and rotary valves. |
76 |
Linear |
77 |
Linear valve |
78 |
Rotary |
79 |
Rotary valve |
80 |
P Gain Index |
81 |
Proportional gain index is from 1 to 20 (with 20 is the highest). |
82 |
1 |
83 |
proportional gain is 0 |
84 |
2 |
85 |
proportional gain is 19 |
86 |
3 |
87 |
proportional gain is 80 |
88 |
4 |
89 |
proportional gain is 132 |
90 |
5 |
91 |
proportional gain is 178 |
92 |
6 |
93 |
proportional gain is 195 |
94 |
7 |
95 |
proportional gain is 207 |
96 |
8 |
97 |
proportional gain is 216 |
98 |
9 |
99 |
proportional gain is 224 |
100 |
10 |
101 |
proportional gain is 229 |
102 |
11 |
103 |
proportional gain is 234 |
104 |
12 |
105 |
proportional gain is 238 |
106 |
13 |
107 |
proportional gain is 241 |
108 |
14 |
109 |
proportional gain is 244 |
110 |
15 |
111 |
proportional gain is 246 |
112 |
16 |
113 |
proportional gain is 249 |
114 |
17 |
115 |
proportional gain is 250 |
116 |
18 |
117 |
proportional gain is 252 |
118 |
19 |
119 |
proportional gain is 254 |
120 |
20 |
121 |
proportional gain is 255 |
122 |
D Gain Switch |
123 |
Derivative gain switch allows finer adjustment of the compensator derivative gain. For small valves this switch should be in the LOW position. |
124 |
Low |
125 |
Switch should be in this position for small valves |
126 |
High |
127 |
Switch should be in this position for larger valves |
128 |
D Gain Index |
129 |
Derivative gain index is from 1 to 20 (with 20 is the highest). |
130 |
derivative gain is 0 |
131 |
derivative gain is 178 |
132 |
derivative gain is 214 |
133 |
derivative gain is 230 |
134 |
derivative gain is 239 |
135 |
derivative gain is 245 |
136 |
derivative gain is 249 |
137 |
derivative gain is 252 |
138 |
derivative gain is 254 |
139 |
derivative gain is 255 |
140 |
derivative gain is 242 |
141 |
derivative gain is 244 |
142 |
derivative gain is 246 |
143 |
derivative gain is 248 |
144 |
derivative gain is 250 |
145 |
derivative gain is 251 |
146 |
derivative gain is 253 |
147 |
Integral Time |
148 |
The integral time is the time ellapsed before the valve try to offset its steady state error when the valve does not move. In each time ellapsed, the valve corrects itself in 0.2% increment. |
149 |
6 s |
150 |
Holdoff time is 6 sec |
151 |
3 s |
152 |
Holdoff time is 3 sec |
153 |
1.5 s |
154 |
Holdoff time is 1.5 sec |
155 |
0.5 s |
156 |
Holdoff time is .5 sec |
157 |
0.25 s |
158 |
Holdoff time is .25 sec |
159 |
Opening Speed |
160 |
The speed limit at which the valve opens. This index limits how fast the control input is applied to the input of the valve feedback loop when valve is opening. |
161 |
Slowest |
162 |
opening speed limit is 16 |
163 |
Slow |
164 |
opening speed limit is 32 |
165 |
Moderate |
166 |
opening speed limit is 64 |
167 |
Fast |
168 |
opening speed limit is 128 |
169 |
Fastest |
170 |
opening speed limit is 65535 |
171 |
Closing Speed |
172 |
The speed limit at which the valve closes. This index limits how fast the control input is applied to the input of the valve feedback loop when valve is closing. |
173 |
close speed limit is 16 |
174 |
close speed limit is 32 |
175 |
close speed limit is 64 |
176 |
close speed limit is 128 |
177 |
close speed limit is 65535 |
178 |
Dig.Setpt |
179 |
Digital Setpoint allows digital control with the percent value specified, when digital mode is enabled. |
180 |
% |
181 |
5.1f |
182 |
Setpn FS |
183 |
Indicates the setpoint upper limit in mA. |
184 |
mA |
185 |
.1f |
186 |
Setpn Zero |
187 |
Indicates the setpoint lower limit in mA. |
188 |
IFS is measured Full Scale Loop Current |
189 |
Max Current |
190 |
5.2f |
191 |
IMN is measured Minimum Loop Current |
192 |
Min Current |
193 |
1.2f |
194 |
4.2f |
195 |
Full scale A/D count |
196 |
Full scale A/D count returned by command 135 |
197 |
MIN scale A/D count |
198 |
Minimum scale A/D count returned by command 135 |
199 |
FS Pwm count |
200 |
FS Pwm count to generate FS trasmitter current |
201 |
Zero Pwm count |
202 |
Zero Pwm count to generate Zero trasmitter current |
203 |
IOutFSZero is measured Full Scale/Zero Loop Current |
204 |
Transmitter Current |
205 |
mA slope |
206 |
mA slope is (IFS-IMN)*2^16/(NFS-NMN) |
207 |
mA offset |
208 |
mA offset is PwmoutFS-(IFS*2^16/mA_slope) |
209 |
Transmitter slope |
210 |
Transmitter slope is (Iout20-Iout4)*2^16/(PwmoutFS-PwmoutZero) |
211 |
Transmitter offset |
212 |
Transmitter offset is (Iout4-PwmoutZero*(Iout20-Iout4)/(PwmoutFS-PwmoutZero)*2^16 |
213 |
Travel Alert |
214 |
When enabled, the positioner will signal alert signal when upper or lower travel limits is violated. |
215 |
Cycle Alert |
216 |
When enabled, the positioner will signal alert signal when cycle limits is violated. |
217 |
Accum. Alert |
218 |
When enabled, the positioner will signal alert signal when accumulator limits is violated. |
219 |
Integral Control |
220 |
When disabled, the positioner will use intrgral control to offset the steady error. |
221 |
Deviation Alert |
222 |
When enabled, the positioner will signal alert signal when deviation limits is violated. |
223 |
ClsLmtSw Alert |
224 |
When enabled, the positioner will signal alert signal when close limit switch is on. |
225 |
OpnLmtSw Alert |
226 |
When enabled, the positioner will signal alert signal when open limit switch is on. |
227 |
Travel High |
228 |
Denotes the upper travel limit of the valve before the travel alert is set. |
229 |
Travel Low |
230 |
Denotes the lower travel limit of the valve before the travel alert is set. |
231 |
Travel DB |
232 |
Denotes the travel limit deadband of the valve. |
233 |
Cycle Count |
234 |
Denotes the cycle count of the valve. |
235 |
Cycle Limit |
236 |
Denotes the cycle limit of the valve before the cycle alert is set. |
237 |
Cycle DB |
238 |
Denotes the cycle deadband of the valve. |
239 |
Accum. Count |
240 |
Denotes the Accumulator count of the valve. |
241 |
Accum. Limit |
242 |
Denotes the accumulator limit of the valve before the accumulator alert is set. |
243 |
Accum. DB |
244 |
Denotes the accumulator deadband of the valve. |
245 |
Deviation DB |
246 |
Denotes the deviation deadband of the valve. |
247 |
Upper Trvl Limit |
248 |
Denotes the upper travel limit the valve can go. |
249 |
Lower Trvl Limit |
250 |
Denotes the lower travel limit the valve can go. |
251 |
illegal calibration code value |
252 |
write_variables |
253 |
Main Menu |
254 |
Manual Cal |
255 |
Position Capture |
256 |
Config |
257 |
Basic Config |
258 |
Cal. Config |
259 |
PID Parameters |
260 |
Slew Speed |
261 |
Setpoint Capture |
262 |
Limit Settings |
263 |
Digital Settings |
264 |
Alert Config |
265 |
Limit Switch Alert |
266 |
Device Info |
267 |
Manufacturer |
268 |
Revision |
269 |
Restore RAM |
270 |
Abort_Calibration |
271 |
Restore analog Set Point |
272 |
Restore digital Set Point |
273 |
Restore Limit Control |
274 |
Digital Adjust |
275 |
Auto Cal |
276 |
Low Cal |
277 |
High Cal |
278 |
Sensor Cal |
279 |
Transducer Cal |
280 |
mA Meter Cal |
281 |
Transmitter Cal |
282 |
Auto PID Cal |
283 |
Analog Capture. |
284 |
Digital Tuning |
285 |
Digital Capture |
286 |
Diagnostics |
287 |
FMU860 |
288 |
DT |
289 |
DVC |
290 |
FCX |
291 |
AS800 |
292 |
340T |
293 |
340C |
294 |
344 |
295 |
Siemens Micro K |
296 |
SITRANS L |
297 |
SIPAN PH |
298 |
SITRANS P |
299 |
75SMT |
300 |
UNIDELTA |
301 |
8320 |
302 |
SX5100 |
303 |
TSV175 |
304 |
DMU |
305 |
3780 |
306 |
BM70 |
307 |
8u |
308 |
Process Cancelled! |
309 |
Restore from EEPROM;Store in RAM;Burn into EEPROM |
310 |
Restore default settings from EEPROM |
311 |
Restore not successful |
312 |
New settings store in RAM only |
313 |
Burn the new settings into EEPROM |
314 |
Burn not successful |
315 |
Abort not Sucessful |
316 |
Switched back to Analog mode |
317 |
Switched back to Digital mode |
318 |
Warning:
Will ignore analog input |
319 |
Enter Set Point in percent |
320 |
Warning:
Setpoint will be set to 50% |
321 |
Switch to digital mode |
322 |
Auto calibration --Please Wait-- |
323 |
Device maybe stuck in Calibration. |
324 |
Auto Cal OK! |
325 |
Low Calibration |
326 |
Deep Cal;Shallow Cal |
327 |
Connect Current Source |
328 |
Switch to analog mode |
329 |
Set Full Closed current |
330 |
Deep low calibration --Please Wait-- |
331 |
Deep Low Cal OK! |
332 |
Will not measure input current |
333 |
Shallow low cal --Please Wait-- |
334 |
Shallow Low Cal OK! |
335 |
High Calibration |
336 |
Set Full Open current |
337 |
Deep high calibration --Please Wait-- |
338 |
Deep High Cal OK! |
339 |
Shallow high cal --Please Wait-- |
340 |
Shallow High Cal OK! |
341 |
Sensor calibration --Please Wait-- |
342 |
Device maybe stuck in Calibration |
343 |
Sensor Cal OK! |
344 |
Warning:
Setpoint will be set to 50 percent |
345 |
Transducer cal --Please Wait-- |
346 |
Transducer Cal OK! |
347 |
Set input current:
3 to 5 mA |
348 |
This will be %[2.2f]{imn} mA |
349 |
Set input current:
19 to 21 mA |
350 |
This will be %[2.2f]{ifs} mA |
351 |
mA meter calibration --Please Wait-- |
352 |
mA_meter Cal OK! |
353 |
Not Calibrated because
NFS=NMN or
IFS=IMN |
354 |
Warning:
Control will switch over to digital mode! |
355 |
Valve is closing |
356 |
Current Zero Transmitter value(mA): |
357 |
Desired Zero Transmitter value(mA): |
358 |
Valve is opening |
359 |
Current FS Transmitter value(mA): |
360 |
Desired FS Transmitter value(mA): |
361 |
Trasmitter Zero will be %[2.2f]{Iout4} mA |
362 |
Trasmitter FS will be %[2.2f]{Iout20} mA |
363 |
Warning: Error occured!
Transmitter output may not accurate |
364 |
Transmitter cal. --Please Wait-- |
365 |
Trasmitter Cal OK! |
366 |
Not Calibrated because
PwmoutFS < PwmoutZero |
367 |
Auto PID calibration --Please Wait-- |
368 |
Auto PID Cal OK! |
369 |
Set new Full Close Current |
370 |
Set new Full Open Current |
371 |
Setpoint Capture --Please Wait-- |
372 |
Setpoint Capture OK! |
373 |
Not Calibrated because
setpt FS=setpt Zero |
374 |
First should be performed deep calibration |
375 |
Capture calibration |
376 |
Zero;Scale;Exit - Burn EEPROM |
377 |
Adjust input current to move the valve to position 0% |
378 |
This valve position will be 0% --Please Wait-- |
379 |
Analog capture 0%:
Calibration OK ! |
380 |
Adjust input current to move the valve to position 100% |
381 |
This valve position will be 100% --Please Wait-- |
382 |
Analog capture 100%:
Calibration OK ! |
383 |
WARNING: Have you performed Zero and Full scale calibrations ? |
384 |
Adjust 0 percent |
385 |
+ 5%;+ 1%;+ 0.1%; OK;- 0.1%;- 1%;- 5% |
386 |
Moved to full open |
387 |
Moving 5% to open |
388 |
Moving 1% to open |
389 |
Moving 0.1% to open |
390 |
Moved to full close |
391 |
Moving 0.1% to close |
392 |
Moving 1% to close |
393 |
Moving 5% to close |
394 |
This valve position will be 0% --Please Wait-- |
395 |
Capture 0%:
Calibration OK ! |
396 |
Adjust 100 percent |
397 |
- 5%;- 1%;- 0.1%; OK;+ 0.1%;+ 1%;+ 5% |
398 |
This will be 100% |
399 |
Digital capture 100% --Please Wait-- |
400 |
Capture 100%:
Calibration OK ! |
401 |
Device maybe stuck in Digital Set Point |
402 |
Digital Capture cal. |
403 |
New value;Done |
404 |
Moving to 0% |
405 |
Adjust 100% |
406 |
Moving to 100% |
407 |
Digital capture 100% --Please Wait-- |
408 |
Warning: Diagnostic Test will be performed in digital mode |
409 |
Enter max deviation(%): |
410 |
max_dev |
411 |
Enter response time(sec): |
412 |
delay_time |
413 |
Setpoint=%[2.1f]{fsetpoint}%
Position=%[2.1f]{position}% |
414 |
Device is out of calibration! |
415 |
Device is ok
Max deviation=%[2.1f]{maxerr}%
in %[i]{delay_time} seconds response |