0 |
|
1 |
|
2 |
Serial number |
3 |
Figure |
4 |
Figure: Status signals |
5 |
Figure: Display |
6 |
Figure: Application |
7 |
Figure: Adjustment |
8 |
Figure: Linearization |
9 |
Figure: Current output |
10 |
Figure: Current output 2 |
11 |
DD version |
12 |
1.03.03-00 |
13 |
Device name |
14 |
VEGAPULS 64 |
15 |
Primary Variable (PV) |
16 |
Selection, which measured value should be outputted as Primary Variable (PV) |
17 |
Percent |
18 |
Lin. percent |
19 |
Filling height |
20 |
Distance |
21 |
Scaled |
22 |
Measurement reliability |
23 |
Electronics temperature |
24 |
Secondary Variable (SV) |
25 |
Selection, which measured value should be outputted as Secondary Variable (SV) |
26 |
Tertiary Variable (TV) |
27 |
Selection, which measured value should be outputted as Third Variable (TV) |
28 |
Quaternary Variable (QV) |
29 |
Selection, which measured value should be outputted as Quaternary Variable (QV) |
30 |
Manufacturer ID |
31 |
x |
32 |
Expanded Device Type |
33 |
Identification of the instrument type through Fieldbus |
34 |
Bustype ID |
35 |
Sensor type |
36 |
DTM ID |
37 |
Device-Revision |
38 |
Compatibility information for integration into the device catalogue |
39 |
Min. current |
40 |
Min. current consumption of the sensor (exception: value in case of failure) |
41 |
3.8 mA |
42 |
4 mA |
43 |
Max. current |
44 |
Max. current consumption of the sensor (exception: value in case of failure) |
45 |
20.5 mA |
46 |
20 mA |
47 |
Output characteristic |
48 |
Selection of the current characteristics |
49 |
0 ... 100 % correspond to 4 ... 20 mA |
50 |
0 ... 100 % correspond to 20 ... 4 mA |
51 |
Failure mode |
52 |
Current consumption of the sensor in case of failure |
53 |
<= 3.6 mA |
54 |
>= 21 mA |
55 |
Last valid measured value |
56 |
Current output 0 % corresponds to |
57 |
Value of the output variable at 0 % |
58 |
.2f |
59 |
Current output 100 % corresponds to |
60 |
Value of the output variable at 100 % |
61 |
Distance unit of the instrument |
62 |
Selection of the physical distance unit for indication and parameter adjustment |
63 |
mm |
64 |
m |
65 |
in |
66 |
ft |
67 |
Temperature unit of the instrument |
68 |
Selection of the physical temperature unit for indication and parameter adjustment |
69 |
�C |
70 |
K |
71 |
�F |
72 |
Measurement loop name |
73 |
Name of the measurement loop |
74 |
Sensor |
75 |
Type of medium |
76 |
Selection of the type of medium |
77 |
Application |
78 |
Special vessel feature |
79 |
Storage tank |
80 |
Storage tank with product agitation |
81 |
Storage tank on ships (cargo tank) |
82 |
Stirrer vessel/Reactor |
83 |
Dosing vessel |
84 |
Plastic vessel (measurement through the vessel top) |
85 |
Transportable plastic tank (measurement through the tank top) |
86 |
Open water (gauge measurement) |
87 |
Open flume (flow measurement) |
88 |
Rain water overflow (weir) |
89 |
Demonstration |
90 |
Vessel form for bulk solids |
91 |
Silo (tall and narrow) |
92 |
Bunker (large volume) |
93 |
Bunker with quick filling |
94 |
Heap (point measurement/profile detection) |
95 |
Crusher |
96 |
Medium |
97 |
Solvents/Liquefied gases/Oils (DK < 3) |
98 |
Chemical mixtures (DK 3 ... 10) |
99 |
Water based solutions/Acids/Alkalis (DK > 10) |
100 |
Powder, dust (granulation size < 1 mm) |
101 |
Granules, pellets (granulation 1 ... 10 mm) |
102 |
Crushed stones, pebbles, boulders (granulation size > 10 mm) |
103 |
Vessel top |
104 |
Selection of the existing vessel top for consideration in the signal processing. |
105 |
Flat |
106 |
Torispherical |
107 |
Vessel bottom |
108 |
Selection of the existing vessel bottom for consideration in the signal processing. |
109 |
Conical |
110 |
Inclined |
111 |
Vessel height/Measuring range |
112 |
Vessel height or for applications without vessel the area in which the measured medium can move |
113 |
.1f |
114 |
.0f |
115 |
.3f |
116 |
Linearization type |
117 |
Selection of the linearization curve |
118 |
Linear |
119 |
User programmable |
120 |
Horizontal cylindrical vessel |
121 |
Spherical vessel |
122 |
Venturi, trapezoidal weir, rectangle weir |
123 |
Palmer-Bowlus Flume |
124 |
V-Notch, triangle weir |
125 |
Pyramid bottom |
126 |
Conical bottom |
127 |
Inclined bottom |
128 |
Vessel height D |
129 |
Total height (inner dimension) |
130 |
Socket correction h |
131 |
Distance of the sensor reference plane to the upper edge of the vessel |
132 |
Graph |
133 |
Selection of the presentation for the measured value image |
134 |
Measured value |
135 |
Measured value with bar graph |
136 |
Two measured values |
137 |
Indication value 1 |
138 |
Determines which measured value should be displayed |
139 |
Current output |
140 |
Current output 2 |
141 |
Menu language |
142 |
Selection of the language for the indicating and adjustment module |
143 |
Deutsch |
144 |
English |
145 |
Fran�ais |
146 |
Espa�ol |
147 |
Portugu�s |
148 |
Italiano |
149 |
Nederlands |
150 |
Pycckuu |
151 |
Polski |
152 |
Cesky |
153 |
T�rk�e |
154 |
Chinese |
155 |
Japanese |
156 |
Lighting |
157 |
Activation of the background lighting of the indicating and adjustment module |
158 |
Off |
159 |
On |
160 |
Indication value 2 |
161 |
Function check |
162 |
Defines, if the diagnostic message 'Function check' should be outputted or suppressed |
163 |
Maintenance required |
164 |
Defines, if the diagnostic message 'Maintenance required' should be outputted or suppressed |
165 |
Out of specification |
166 |
Defines, if the diagnostic message 'Out of specification' should be outputted or suppressed |
167 |
Software version |
168 |
Version of the instrument software |
169 |
SIL qualified sensor |
170 |
No |
171 |
Yes |
172 |
Password |
173 |
Software version of the main electronics |
174 |
0 |
175 |
Hardware version |
176 |
Hardware version of the main electronics |
177 |
Fieldbus Profile Rev. |
178 |
.4f |
179 |
Status distance |
180 |
Failure |
181 |
Upper limitation |
182 |
Lower limitation |
183 |
Simulation value |
184 |
Substitute value |
185 |
Constant value |
186 |
Status filling height |
187 |
cm |
188 |
mbar |
189 |
bar |
190 |
Pa |
191 |
kPa |
192 |
MPa |
193 |
psi |
194 |
mmH2O |
195 |
mmHg |
196 |
inH2O |
197 |
ftH2O |
198 |
inHg |
199 |
torr |
200 |
User defined |
201 |
l |
202 |
hl |
203 |
m� |
204 |
in� |
205 |
gal |
206 |
ft� |
207 |
bbl |
208 |
ImpGal |
209 |
yd� |
210 |
bbl_liq |
211 |
bush |
212 |
kg |
213 |
t |
214 |
lb |
215 |
g |
216 |
STon |
217 |
LTon |
218 |
oz |
219 |
kg/m� |
220 |
kg/dm� |
221 |
g/cm� |
222 |
g/ml |
223 |
g/l |
224 |
lb/gal |
225 |
lb/in� |
226 |
STon/yd� |
227 |
deg Brix |
228 |
deg Baume lt |
229 |
deg Baume hv |
230 |
% sol wt |
231 |
% sol vol |
232 |
API |
233 |
pcf |
234 |
SGU |
235 |
l/s |
236 |
l/min |
237 |
l/h |
238 |
Ml/d |
239 |
m�/s |
240 |
m�/min |
241 |
m�/h |
242 |
m�/d |
243 |
gal/s |
244 |
gal/min |
245 |
gal/h |
246 |
gal/d |
247 |
Mgal/d |
248 |
ft�/s |
249 |
ft�/min |
250 |
ft�/h |
251 |
ft�/d |
252 |
bbl/s |
253 |
bbl/min |
254 |
bbl/h |
255 |
bbl/d |
256 |
ImpGal/s |
257 |
ImpGal/min |
258 |
ImpGal/h |
259 |
ImpGal/d |
260 |
g/s |
261 |
g/min |
262 |
g/h |
263 |
kg/s |
264 |
kg/min |
265 |
kg/h |
266 |
kg/d |
267 |
lb/s |
268 |
lb/min |
269 |
lb/h |
270 |
lb/d |
271 |
STon/min |
272 |
STon/h |
273 |
STon/d |
274 |
LTon/h |
275 |
LTon/d |
276 |
t/min |
277 |
t/h |
278 |
t/d |
279 |
mA |
280 |
% |
281 |
- |
282 |
pF |
283 |
ct/s |
284 |
lb/ft |
285 |
kg/m |
286 |
Hz |
287 |
dB |
288 |
V |
289 |
mV |
290 |
unknown |
291 |
m/s |
292 |
m/h |
293 |
ft/s |
294 |
ft/min |
295 |
Status percent |
296 |
Status lin. percent |
297 |
Sensor acc. to WHG |
298 |
Use as a part of an overfill protection system according to WHG |
299 |
Integration time (t) |
300 |
Damping of measured value peaks |
301 |
s |
302 |
Distance B |
303 |
Distance from sensor reference plane to product surface at min. level |
304 |
Distance A |
305 |
Distance from sensor reference plane to product surface at max. level |
306 |
Min. adjustment in % |
307 |
Level in percent for which the distance 'Distance B' must be entered |
308 |
Max. adjustment in % |
309 |
Level in percent for which the distance 'Distance A' must be entered |
310 |
Status scaled |
311 |
Actual electronics temperature |
312 |
Status electronics temperature |
313 |
Status meas. reliability |
314 |
Status current output 2 |
315 |
Date of the min. electronics temperature |
316 |
Min. electronics temperature |
317 |
Date of the max. electronics temperature |
318 |
Max. electronics temperature |
319 |
Date of the min. distance |
320 |
Min. distance |
321 |
Date of the max. distance |
322 |
Max. distance |
323 |
Date of the min. measurement reliability |
324 |
Minimum measurement reliability |
325 |
Date of the max. measurement reliability |
326 |
Max. measurement reliability |
327 |
PIN |
328 |
Determine the PIN which should be valid for the function 'Lock adjustment' |
329 |
04d |
330 |
0 % corresponds to |
331 |
Scaled value for 0 % |
332 |
100 % corresponds to |
333 |
Scaled value for 100 % |
334 |
Scaling unit |
335 |
Measuring unit for the scaled value |
336 |
Scaling format |
337 |
Determination of the presentation of decimal points |
338 |
# |
339 |
#.# |
340 |
#.## |
341 |
#.### |
342 |
#.#### |
343 |
Factory calibration date |
344 |
Date of the last factory calibration |
345 |
Device status |
346 |
Device status acc. to NE 107 |
347 |
OK |
348 |
Malfunction |
349 |
Detail status |
350 |
Detailed status value for identification of the exact cause of error |
351 |
Device address |
352 |
Loop current mode |
353 |
Fixed current (4 mA) |
354 |
Analogue current output (4 ... 20 mA) |
355 |
HART Device Status |
356 |
Primary variable out of limits |
357 |
Non-primary variable out of limits |
358 |
Analog output saturated |
359 |
Analog output fixed |
360 |
More status available |
361 |
Cold start |
362 |
Configuration changed |
363 |
Field device malfunction |
364 |
'First large echo' active |
365 |
Amplitude threshold 'First large echo' |
366 |
d |
367 |
Width focusing range |
368 |
Time for opening of the focus range |
369 |
Minimum measurement reliability |
370 |
Min. measuring reliability outside the focusing range |
371 |
Behaviour in case of loss of echo |
372 |
Failure message |
373 |
Maintenance message |
374 |
Delay 'Fault signal with echo loss' |
375 |
Limitation measuring range begin active |
376 |
Limitation measuring range begin |
377 |
Certainty at vessel bottom or measuring range end |
378 |
Additional factor safety at the measuring range end |
379 |
Correction of propagation velocity |
380 |
Averaging factor on increasing amplitude |
381 |
Averaging factor on decreasing amplitude |
382 |
'Smooth raw value curve' active |
383 |
Offset detection curve |
384 |
Safety of the false signal suppression |
385 |
'Automatic false signal management' active |
386 |
Function 'Combine echoes' |
387 |
Deactivated |
388 |
Only bottom section |
389 |
Complete measuring range |
390 |
Amplitude difference 'Combine echoes' |
391 |
Position difference 'Combine echoes' |
392 |
Measured value offset |
393 |
Function measured value filter |
394 |
Automatically |
395 |
Low averaging |
396 |
High averaging |
397 |
Activity to be carried out |
398 |
Restore delivery status |
399 |
Restore basic settings |
400 |
False signal suppression |
401 |
Selection of an activity to process the gating out of false signals |
402 |
Create new |
403 |
Extend |
404 |
Delete part |
405 |
Delete all |
406 |
Sounded distance from the sealing surface to the medium |
407 |
Up to the entered distance (less a safety distance), all echoes will be stored as false signals |
408 |
Simulation active |
409 |
from |
410 |
Distance from the sensor reference plane to the range starting point |
411 |
to |
412 |
Distance from the sensor reference plane to the range end point |
413 |
Intermediate height h |
414 |
The intermediate height 'h' specifies the height of the non-linear area for the linearization types 'Pyramid bottom', 'Conical bottom' or 'Inclined bottom' |
415 |
Output mode |
416 |
Analogue current output |
417 |
LONG-TAG |
418 |
MESSAGE |
419 |
Message stored in the instrument for free use |
420 |
Simulation, current output |
421 |
Simulation, current output 2 |
422 |
Simulation, percent |
423 |
Simulation, lin. percent |
424 |
Simulation, filling height |
425 |
Simulation filling height of the level |
426 |
Simulation, distance |
427 |
Simulation, physical value |
428 |
Simulation, reliability |
429 |
Simulation, electronics temperature |
430 |
Zoom range from |
431 |
Defines the start of the zoom area for presentation of the echo curve |
432 |
Zoom range up to |
433 |
Defines the end of the zoom area for presentation of the echo curve |
434 |
Store echo curve |
435 |
Echo curve of the setup |
436 |
Echo curve memory |
437 |
Echo damping in the close range |
438 |
Weak damping |
439 |
Average damping |
440 |
Strong damping |
441 |
Display format 1 |
442 |
Selection of the requested formatting of the display value shown on the display and adjustment module |
443 |
Display format 2 |
444 |
Setup |
445 |
Diagnostics |
446 |
Additional settings |
447 |
Linearization |
448 |
Info |
449 |
Measured values |
450 |
Figure: Setup |
451 |
Figure: Damping |
452 |
Figure: Simulation |
453 |
Figure: Reset |
454 |
Figure: Scaling |
455 |
Bild: PV Abgleich |
456 |
Figure: HART variables |
457 |
Figure: Service login |
458 |
Figure: Linearization table |
459 |
Figure: Info |
460 |
Display |
461 |
Settings in the special parameters were carried out. A change of application is only possible after resetting the sensor to delivery status. |
462 |
Adjustment |
463 |
Damping |
464 |
The sensor is in multidrop mode |
465 |
Status signals |
466 |
The instrument has a self-monitoring acc. to NE 107. Define the diagnostic states to be outputted by the instrument. |
467 |
Measured value status |
468 |
Status, outputs |
469 |
Status, additional measured values |
470 |
Peak indicator, distance |
471 |
Peak indicator, reliability |
472 |
Peak indicator, electronics temperature |
473 |
Reset |
474 |
Scaling |
475 |
PV adjustment |
476 |
The selected output variable is also assigned to the first HART value (PV). |
477 |
HART variables |
478 |
Service login |
479 |
Special parameters |
480 |
If the upper edge of the socket is below the upper edge of the vessel, then the value must be entered with negative signs. |
481 |
Outputs |
482 |
Additional measured values |
483 |
Read values from device |
484 |
Write values to device |
485 |
Linearization table |
486 |
Linearization curve |
487 |
Table |
488 |
Echo curve |
489 |
--- |
490 |
Echo curve (curve) |
491 |
Show echo curve |
492 |
Settings |
493 |
Load actual echo curves |
494 |
Load selected curves |
495 |
Store echo curve of the setup |
496 |
Load false signal suppression |
497 |
Load setup curve |
498 |
Device characteristics |
499 |
Details |
500 |
Version |
501 |
Update instrument features |
502 |
Simulation |
503 |
Activate simulation |
504 |
Deactivate simulation |
505 |
Apply simulation value |
506 |
Identification |
507 |
Service login required |
508 |
Measured value memory (EDD) |
509 |
Parameter adjustment |
510 |
Maintenance |
511 |
Service logout |
512 |
Reset? |
513 |
Reset 'Configuration changed' |
514 |
Reset peak indicator |
515 |
GetHealthStatus |
516 |
VEGA Grieshaber KG |
517 |
Error in the calibration |
518 |
Exchange electronics or return device for repair |
519 |
Error in the device setting |
520 |
Repeat setup or reset |
521 |
Installation/setup error |
522 |
Check installation and/or parameter adjustment |
523 |
Measurement function disturbed |
524 |
Carry out a reset or briefly separate operating voltage |
525 |
Communication error |
526 |
Briefly separate operating voltage, exchange device |
527 |
Impermissible operating voltage |
528 |
Check electrical connections |
529 |
No measured value available |
530 |
Adjusted span too small |
531 |
Change adjustment according to the limit values |
532 |
Error in the linearization table |
533 |
Check linearization table |
534 |
No executable software |
535 |
Repeat update, exchange electronics or device |
536 |
Error in the electronics |
537 |
General software error |
538 |
Briefly separate operating voltage |
539 |
Measured value is determined |
540 |
Wait for switch-on phase |
541 |
Inpermissible electronics temperature |
542 |
Check ambient temperature, isolate electronics |
543 |
Check ambient temperature, isolate electronics or use a device with higher temperature range |
544 |
Overfill protection for liquids |
545 |
Make sure that no more filling is made and check the level in the vessel |
546 |
Level within the search range compensation echo |
547 |
100 % adjustment: Increase value |
548 |
Error in the delivery status |
549 |
Repeat reset or load XML file with sensor data into the sensor |
550 |
Error in the non-active linearization table |
551 |
Error in the event memory |
552 |
Reliability too low |
553 |
Check the installation and process conditions |
554 |
Error on a device interface |
555 |
Check the connections, exchange the electronics or return the device for repair |
556 |
Optimize sensor position and orientation |
557 |
Check installation, parameter adjustment as well as probe length |
558 |
Carry out a reset and repeat setup |
559 |
Meas. reliability, level |
560 |
Unlock adjustment |
561 |
Verify and lock adjustment |
562 |
Verify adjustment |
563 |
Lock adjustment |
564 |
Common Tables |
565 |
Interoperable * |
566 |
Universal |
567 |
Common Practice |
568 |
Pressure Universal |
569 |
Pressure Common |
570 |
Menu |
571 |
Rosemount Magflow |
572 |
Rosemount Pressure |
573 |
Moore Products |
574 |
Siemens Pressure |
575 |
P2 Common |
576 |
PV |
577 |
Wireless |
578 |
Munge |
579 |
Analytical Oxygen/Combustion/Methane/CO |
580 |
Flow Totalizer - Rate Indicator |
581 |
Flow Variable Area |
582 |
Flow Coriolis Mass |
583 |
Flow Ultrasonic - Gas |
584 |
Flow Ultrasonic - Liquid |
585 |
Level Ultrasonic |
586 |
Level Radar - Microwave |
587 |
Pressure Absolute |
588 |
Level Capacitance |
589 |
Pressure Differential |
590 |
Level Hydrostatic |
591 |
Level |
592 |
Pressure Absolute/Relative |
593 |
Level Microwave |
594 |
Level Radar |
595 |
Level Density - Nuclear |
596 |
Flow Electromagnetic |
597 |
Flow Vortex |
598 |
Flow Magmeter - Rack Version |
599 |
Flow High Performance Magmeter |
600 |
Flow Mass |
601 |
Flow Ultrasonic |
602 |
Flow Magnetic |
603 |
Flow Magnetic - Custody Transfer |
604 |
Flow 2-wire Magnetic |
605 |
Flow Coriolis Mass - Custody Transfer |
606 |
Flow 2-wire Vortex |
607 |
Flow Thermal |
608 |
Temperature Head Mounted |
609 |
Temperature Compact |
610 |
Temperature DIN Rail Mounted |
611 |
Analytical pH |
612 |
Analytical Conductivity - Conductive |
613 |
Analytical Conductivity - Inductive |
614 |
Temperature Sensor |
615 |
Level Servo |
616 |
Temperature DIN Rail |
617 |
Temperature |
618 |
Analytical ORP |
619 |
Analytical pION |
620 |
Analytical IConc |
621 |
Analytical Electrode Conductivity |
622 |
Analytical Toroidal Conductivity |
623 |
Valve Positioner |
624 |
Valve Controller |
625 |
Pressure |
626 |
Pressure Multivariable |
627 |
Analytical pH/ORP |
628 |
Flow Coriolis |
629 |
Analytical Conductivity |
630 |
Valve Positioner/Pneumatic |
631 |
Valve Actuator - Electrical |
632 |
Temperature Dual Input |
633 |
Valve Actuator |
634 |
Analytical Corrosion |
635 |
Analytical Density - Nuclear |
636 |
Level Continuous Gamma |
637 |
Level Laser Ranging |
638 |
Pressure Safety |
639 |
Flow Vortex/Swirl |
640 |
Flow |
641 |
Analytical 4 Electrode Conductivity |
642 |
Analytical 2 Electrode Conductivity |
643 |
Analytical Troidal Conductivity |
644 |
Analytical pH/ORP/pIon/Ion Conc |
645 |
Analytical Oxygen |
646 |
Pressure P, dP + Multivariable |
647 |
Temperature 2-wire |
648 |
Pressure w/ PID |
649 |
Pressure Saturated Steam |
650 |
Analytical Density - Gamma Ray |
651 |
Level Gamma Ray |
652 |
Analytical Weight - Gamma Ray |
653 |
Level w/ Density - Gamma Ray |
654 |
Analytical Motorized Density |
655 |
Flow Multivariable Mass |
656 |
Temperature Multivariable |
657 |
Specialty HART-to-Analog Signal Conv |
658 |
Flow dP |
659 |
Pressure Low Power |
660 |
Pressure Certified SIL2 |
661 |
Interoperable |
662 |
Analytical Density |
663 |
Valve Positioner/Electropneumatic |
664 |
Flow Magnetic Inductive |
665 |
Analytical |
666 |
Analytical Opacity Monitor |
667 |
Analytical Oxygen/Combustion |
668 |
Analytical 2-wire Conductivity |
669 |
Analytical 2-wire Conductivity w/ pure H20 |
670 |
Analytical 2-wire Conductivity w/ % conc |
671 |
Analytical 2-wire Oxygen/Chlorine/Ozone |
672 |
Analytical 2-wire pH/ORP |
673 |
Analytical 2-wire Contacting/Toroidal |
674 |
Analytical Oxygen - High Temperature |
675 |
Analytical Conductivity w/ % conc |
676 |
Analytical pH/ORP/ISE |
677 |
Analytical Amperometric Analyzer |
678 |
Analytical Dual Input Analyzer |
679 |
Pressure Pressure/Level |
680 |
Analytical Consistency |
681 |
Analytical Microwave-Pulp Consistency |
682 |
Analytical Microwave Consistency |
683 |
Valve Digital Positioner |
684 |
Valve Smart Valve Positioner |
685 |
Temperature Differential |
686 |
Analytical Dissolved Oxygen |
687 |
Analytical pH Controller |
688 |
Analytical Conductivity/Resistivity Controller |
689 |
Analytical Conductivity/Resistivity |
690 |
Level Displacement |
691 |
Temperature w/ PID |
692 |
Valve Universal Positioner |
693 |
Level Radar - Reflex |
694 |
Pressure Gauge |
695 |
Pressure Sealed Gauge |
696 |
Valve Digital Positioner w/ PID |
697 |
Valve Intelligent Positioner |
698 |
Analytical Gas Detector |
699 |
Analytical Infrared Gas Detector |
700 |
Analytical Electrochemical Gas Detector |
701 |
Analytical Measuring Instruments |
702 |
Level Magnostrictive |
703 |
Valve On/Off Valve Controller |
704 |
Level Radar - Pulse |
705 |
Level Continuous Capactive |
706 |
Valve Damper Actuator |
707 |
Valve Electric Damper Actuator |
708 |
Flow Electronic |
709 |
Flow Vortex - Multiparameter Mass |
710 |
Analytical UV Flame Detector |
711 |
Analytical UVIR Flame Detector |
712 |
Analytical IR Flame Detector |
713 |
Analytical Fire Detector |
714 |
Analytical Gas Detector Display Interface |
715 |
Analytical Toxic Gas Detector |
716 |
Analytical Flame Detector |
717 |
Level Nuclear |
718 |
Analytical Microwave |
719 |
Analytical Density - Radiometric |
720 |
Level Radiometric |
721 |
Analytical Gas/Steam |
722 |
Level Nucleonic |
723 |
Analytical Blade Consistency |
724 |
Analytical Rotary Consistency |
725 |
Pressure Absolute/Differential |
726 |
Positioner |
727 |
Analytical Combustible Gas Detector |
728 |
Analytical Point Infrared Gas Detector |
729 |
Analytical Multi-Detector Monitor System |
730 |
Valve Positioner/Electro-hydraulic |
731 |
Valve Monitor |
732 |
Enable on token-passing data link layer only |
733 |
Enable on TDMA data link layer only |
734 |
Enable on both TDMA and token-passing data link layer |
735 |
WirelessHART Device |
736 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
737 |
Primary |
738 |
Primary Analog Channel |
739 |
Secondary |
740 |
Secondary Analog Channel |
741 |
Tertiary |
742 |
Tertiary Analog Channel |
743 |
Quaternary |
744 |
Quaternary Analog Channel |
745 |
Quinary |
746 |
Quinary Analog Channel |
747 |
Critical Power Failure |
748 |
Lock all |
749 |
Trim not supported |
750 |
Configuration cannot be changed |
751 |
Locked by gateway |
752 |
Analog Input Channel |
753 |
Analog Output Channel |
754 |
Secondary Analog Channel Saturated |
755 |
Tertiary Analog Channel Saturated |
756 |
Quaternary Analog Channel Saturated |
757 |
Quinary Analog Channel Saturated |
758 |
Secondary Analog Channel Fixed |
759 |
Tertiary Analog Channel Fixed |
760 |
Quaternary Analog Channel Fixed |
761 |
Quinary Analog Channel Fixed |
762 |
Simulation active |
763 |
The device is in simulation mode and the level output is not representative of the process. |
764 |
Non-Volatile memory failure |
765 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
766 |
Volatile memory error |
767 |
The RAM memory check is invalid or maybe corrupt |
768 |
Watchdog reset executed |
769 |
A watchdog reset has been performed |
770 |
Voltage conditions out of range |
771 |
A voltage condition is outside its allowable range |
772 |
Environmental conditions out of range |
773 |
An internal or environmental condition is beyond acceptable limits. |
774 |
Electronic failure |
775 |
A hardware problem not related to the sensor has been detected. |
776 |
Subdevice list changed |
777 |
Duplicate master detected |
778 |
Capacity Denied |
779 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
780 |
Bandwidth allocation pending |
781 |
Block transfer pending |
782 |
Continuous |
783 |
The Burst Message is published continuously at (worst case) the Minimum Update Period. |
784 |
Window |
785 |
The Burst Message is triggered when the source value deviates more than the specified trigger value |
786 |
Rising |
787 |
The Burst Message is triggered when source value Rises Above the specified trigger value. |
788 |
Falling |
789 |
The Burst Message is triggered when the source value Falls Below the specified trigger value. |
790 |
On-change |
791 |
The Burst Message is triggered when any value in the message changes. |
792 |
Battery life |
793 |
Percent range |
794 |
Loop current |
795 |
Primary variable |
796 |
Secondary variable |
797 |
Tertiary variable |
798 |
Quaternary variable |
799 |
Off |
800 |
Enable event notification on token-passing data link layer |
801 |
Enable event notification on TDMA data link layer |
802 |
Enable event notification on TDMA and token-passing data link layer |
803 |
Configuration changed event pending |
804 |
Device status event pending |
805 |
More status available event pending |
806 |
Disable |
807 |
Enable single data point trending |
808 |
Enable filtered trending |
809 |
The sample is filtered using a time constant equal to one-third the trend sample period |
810 |
Enable average trending |
811 |
The value obtained by dividing the sum of all samples in the period by the total number of samples |
812 |
Read receive time |
813 |
Write date and time |
814 |
Non-Volatile Clock |
815 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
816 |
Clock Uninitialized |
817 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
818 |
Line Power |
819 |
Device is powered via a hardwired connection to a plant power source. |
820 |
Battery Power |
821 |
Device operates solely of its (internal) battery. |
822 |
Recharg.B./Power Sc. |
823 |
Rechargeable battery power or power scavenging. The device has a short-term supply of energy (must be at least one hour) that is continuously being replenished. The device's power is being replenished by harvesting and converting energy from the environment surrounding the device (e.g. solar, vibration, heat). |
824 |
Idle |
825 |
Active search |
826 |
Looking for neighbors. |
827 |
Negotiating |
828 |
Quarantined |
829 |
Operational |
830 |
Suspended |
831 |
Deep sleep |
832 |
Ultra-low power |
833 |
Wireless Signal Found |
834 |
Network packets have been recognized |
835 |
Wireless Signal Identified |
836 |
Wireless Time Synchronized |
837 |
WirelessHart Signal Identified |
838 |
Network Admission Requested |
839 |
Set on transmission of first join request |
840 |
Join Retrying |
841 |
Set after the first join request retry (i.e. when number of join requests > 2). Cleared when device is authenticated or when Active Search started. |
842 |
Join Failed |
843 |
Set on transition from Active Search mode to Deep Sleep mode. Cleared on transition from Deep Sleep to Active Search. |
844 |
Network Security Clearance Granted |
845 |
Network Manager Session Established |
846 |
Network Joined |
847 |
Network Joined. Normal superframe and links obtained. |
848 |
Network Bandwidth Requested |
849 |
Negotiating Network Properties. Gateway session obtained. |
850 |
Join Complete |
851 |
Normal operating mode. |
852 |
None |
853 |
No restrictions |
854 |
SI Only |
855 |
Restricted to SI Unit codes only |
856 |
Open - accept all devices |
857 |
Use Whitelist for access |
858 |
Use Blacklist |
859 |
Use Whitelist and Blacklist |
860 |
Lockdown - disable join links |
861 |
Process automation device |
862 |
Discrete device |
863 |
Hybrid:Process automation+discrete |
864 |
I/O System |
865 |
WirelessHART Process automation device |
866 |
WirelessHART Discrete device |
867 |
WirelessHART Process automation+discrete |
868 |
WirelessHART Gateway |
869 |
WirelessHART Access point |
870 |
WirelessHART Process adapter |
871 |
WirelessHART Discrete adapter |
872 |
WirelessHART enabled handheld/portable maintenance tool |
873 |
Don't attempt to join |
874 |
Join now |
875 |
Attempt to join immediately on powerup or reset |
876 |
US |
877 |
United States of America |
878 |
JP |
879 |
Japan |
880 |
DE |
881 |
Germany |
882 |
FR |
883 |
France |
884 |
ES |
885 |
Spain |
886 |
RU |
887 |
Russian Federation |
888 |
CN |
889 |
People's Republic of China |
890 |
Nominal |
891 |
Device Power Status is nominal |
892 |
Low |
893 |
Device Power Status is low |
894 |
Critically Low |
895 |
Device Power Status is critically low |
896 |
Recharging - Low |
897 |
Recharging - High |
898 |
Secondary Master |
899 |
Primary Master |
900 |
PV Analog Channel Saturated |
901 |
PV Analog Channel Fixed |
902 |
Device Profile |
903 |
Device Diagnostic Status 0 |
904 |
Device Diagnostic Status 1 |
905 |
I/O and Subdevice Status |
906 |
WirelessHART Status |
907 |
Time Set Option |
908 |
Real Time Clock Flags |
909 |
Country |
910 |
Country of intended device installation |
911 |
SI Unit Control |
912 |
Indicates if device should only display SI unit codes |
913 |
Burst Trigger Units |
914 |
Burst Trigger Class |
915 |
Wired HART Enabled |
916 |
Enabled on Wired HART device connection only |
917 |
Wireless HART Enabled |
918 |
Enabled on WirelessHART device connection only |
919 |
Both Wired and WirelessHart Enabled |
920 |
Enabled on both Wired and WirelessHART connections |
921 |
Burst Msg Trigger Mode |
922 |
Event Status |
923 |
Event Notification Control |
924 |
Operate mode Mask |
925 |
Not Defined |
926 |
Power Source |
927 |
Power source of the device |
928 |
Wireless Mode |
929 |
Join Status |
930 |
The current location in the joining sequence of operations. |
931 |
Network Access Mode |
932 |
Join Mode |
933 |
Power Status |
934 |
Power status of the device |
935 |
Master Mode |
936 |
This sets the I/O System's Data Link Layer operation on all channels as either primary or secondary master mode. |
937 |
Trend Units |
938 |
Trend Device Variable Unit Code |
939 |
Trend Classification |
940 |
Trend Device Variable Classification |
941 |
Trend Control |
942 |
uint16_var_blk_char |
943 |
uint8_var_blk_char |
944 |
Device Status Mask |
945 |
Ext dev status Mask |
946 |
Device Diagnostic Status 0 Mask |
947 |
Device Diagnostic Status 1 Mask |
948 |
Device Diagnostic Status 2 Mask |
949 |
Device Diagnostic Status 3 Mask |
950 |
AO saturated Mask |
951 |
AO fixed Mask |
952 |
Latched Device Status |
953 |
Latched Ext dev status |
954 |
Latched Operate Mode |
955 |
Latched Device Diagnostic Status 0 |
956 |
Latched Device Diagnostic Status 1 |
957 |
Latched Device Diagnostic Status 2 |
958 |
Latched Device Diagnostic Status 3 |
959 |
Latched AO saturated |
960 |
Latched AO fixed |
961 |
Wireless Module Device Type |
962 |
Device type of the Wireless Radio |
963 |
Wireless Module Manufacturer ID |
964 |
Manufacturer of the Wireless Radio contained in this device |
965 |
Subdevice Device Type |
966 |
Device type of the subdevice attached to this system. |
967 |
Subdevice Manufacturer Id |
968 |
Manufacturer of the subdevice attached to this system. |
969 |
8u |
970 |
Dynamic Variables Returned for Device Variables |
971 |
Command Response Truncated |
972 |
Configuration Change Counter Mismatch |
973 |
Status bytes mismatch |
974 |
8.3f |
975 |
Output Status |
976 |
Output Status Byte |
977 |
Uninitialized |
978 |
Normal - one sensor |
979 |
Normal - two sensors |
980 |
Normal - three sensors |
981 |
Shorted |
982 |
Shorted- shorted field wiring. |
983 |
Limited high |
984 |
Limited high- block can not respond to upward movement of value. |
985 |
Open |
986 |
Open- open field wiring. |
987 |
Limited low |
988 |
Limited low- block can not respond to upward movement of target. |
989 |
Initialization done |
990 |
Initialization done- block initialization is complete. |
991 |
Not selected |
992 |
Not selected- target value provided by block was not selected. |
993 |
No path |
994 |
No path- there is no path to the process. |
995 |
Fail |
996 |
Fail- hardware failure. |
997 |
Bad |
998 |
Bad- block is out of service or has bad input. |
999 |
Not from process |
1000 |
Not from process- value is not directly affected by any process information. |
1001 |
Local override |
1002 |
Local override- block has LO mode. |
1003 |
Not Cascade Mode |
1004 |
Not RCas Mode |
1005 |
Not ROut Mode |
1006 |
No communication |
1007 |
No communication- (NO_COM). |
1008 |
uint32_var_blk_char |
1009 |
int8_var_blk_char |
1010 |
new itest redef1 label |