0 |
DX PST with HRT 7 |
1 |
TopWorx Inc. |
2 |
Failure - Fix Now |
3 |
Out of Specification - Fix Soon |
4 |
Function Check |
5 |
Device Configuration Locked |
6 |
Status Simulation Active |
7 |
Discrete Variable Simulation Active |
8 |
Event Notification Overflow |
9 |
Status Simulation Active |
10 |
Discrete Variable Simulation Active |
11 |
Event Notification Overflow |
12 |
Signal invalid due to malfunction in the device or sensor. |
13 |
Permissible ambient or process conditions exceeded or the measuring uncertainty of sensors is probably greater than expected. |
14 |
Signal temporarily invalid due to on-going work on the device. |
15 |
The device is locked by the host. |
16 |
Status alerts are being simulated. |
17 |
Discrete variables are being simulated. |
18 |
Event notification buffers have overflowed. |
19 |
msec |
20 |
Communication Fault |
21 |
A device peripheral bus communication fault has occurred. |
22 |
Low Frequency Oscillator Fault |
23 |
The low frequency clock source failed to start. |
24 |
Local Calibration in Progress |
25 |
Valve position may not reflect actual value during calibration. |
26 |
Temperature Sensor Failure |
27 |
The device temperature sensor has failed. |
28 |
Calibration Span Failed |
29 |
Valve stroke is too small or bad calibration. |
30 |
Cycle Count Limit Alert |
31 |
Cycle Count Limit has been exceeded. |
32 |
DAC Trim Required |
33 |
DAC trim is required to ensure accurate loop current output. |
34 |
Valve Calibration Required |
35 |
Calibrate the valve travel into the device. |
36 |
Last Close Stroke Time Alert |
37 |
Set when the stroke time is outside the range set by the upper and lower limit ranges. |
38 |
Last Open Stroke Time Alert |
39 |
Closed Dwell Time Alert |
40 |
Open Dwell Time Alert |
41 |
Electrical Hardware Failure |
42 |
Set when an electrical component on the device failed. |
43 |
DAC Output Voltage Out of Range |
44 |
The loop transistor drive voltage is lower or higher than expected. |
45 |
Position Sensor Fault |
46 |
The device detected an issue with the position sensor. |
47 |
Limit Switch Fault |
48 |
The device detected an issue with the limit switch. |
49 |
Transition Dwell Time Alert |
50 |
Set when the transition dwell time exceeds the upper limit parameter. |
51 |
Solenoid 1 Voltage Out of Range |
52 |
Set when the voltage at Solenoid 1 has exceeded the allowable tolerance. |
53 |
Solenoid 1 Current Out of Range |
54 |
Set when the current at Solenoid 1 has exceeded the allowable tolerance. |
55 |
Solenoid 2 Voltage Out of Range |
56 |
Set when the voltage at Solenoid 2 has exceeded the allowable tolerance. |
57 |
Solenoid 2 Current Out of Range |
58 |
Set when the current at Solenoid 2 has exceeded the allowable tolerance. |
59 |
Partial Stroke Time Out of Tolerance |
60 |
Partial Stroke Test has failed. |
61 |
Partial Stroke Valve Break Away Time Out of Tolerance |
62 |
The time between solenoid activation and valve movement has exceeded the allowable tolerance on open. |
63 |
Partial Stroke Calibration Required |
64 |
PST calibration is required before a PST can be executed. |
65 |
Close Break Away Time Out of Tolerance |
66 |
The time between solenoid activation and valve movement has exceeded the allowable tolerance on close. |
67 |
SOV State Change Failure |
68 |
SOV failed to change state. |
69 |
Emergency Shutdown Alert |
70 |
Device has detected an Emergency Shutdown Event. |
71 |
High Pressure Limit Alert |
72 |
Pressure sensor has detected pressure value above upper pressure limit parameter. |
73 |
Low Pressure Limit Alert |
74 |
Pressure sensor has detected pressure value below lower pressure limit parameter. |
75 |
Pressure Sensor Fault |
76 |
The device detected an issue with the pressure sensor. |
77 |
PST Pressure Out of Limits |
78 |
The pressure value at the start of the PST test or the pressure at the return point was out of range. |
79 |
Solenoid 1 Communication Fault |
80 |
Solenoid communication has failed. |
81 |
Solenoid 2 Communication Fault |
82 |
Solenoid 1 Fault |
83 |
Solenoid operation has failed. |
84 |
Solenoid 2 Fault |
85 |
Communication Fault |
86 |
Local Calibration in Progress |
87 |
Temperature Sensor Failure |
88 |
Calibration Span Failed |
89 |
Cycle Count Limit Alert |
90 |
DAC Trim Required |
91 |
Valve Calibration Required |
92 |
Last Close Stroke Time Alert |
93 |
Last Open Stroke Time Alert |
94 |
Closed Dwell Time Alert |
95 |
Open Dwell Time Alert |
96 |
Electrical Hardware Failure |
97 |
DAC Output Voltage Out of Range |
98 |
Position Sensor Fault |
99 |
Limit Switch Fault |
100 |
Transition Dwell Time Alert |
101 |
Solenoid 1 Voltage Out of Range |
102 |
Solenoid 1 Current Out of Range |
103 |
Solenoid 2 Voltage Out of Range |
104 |
Solenoid 2 Current Out of Range |
105 |
Partial Stroke Time Out of Tolerance |
106 |
Partial Stroke Valve Break Away Time Out of Tolerance |
107 |
Partial Stroke Calibration Required |
108 |
Close Break Away Time Out of Tolerance |
109 |
SOV State Change Failure |
110 |
Emergency Shutdown Alert |
111 |
High Pressure Limit Alert |
112 |
Low Pressure Limit Alert |
113 |
Pressure Sensor Fault |
114 |
Low Frequency Oscillator Fault |
115 |
Limit Switch 1 |
116 |
Limit Switch 2 |
117 |
Auxiliary/Pressure Switch 2 |
118 |
Internal Device Temperature |
119 |
Last Close Stroke Time |
120 |
Last Open Stroke Time |
121 |
Open Dwell Time |
122 |
Close Dwell Time |
123 |
Cycle Count |
124 |
Highest Device Temperature |
125 |
Lowest Device Temperature |
126 |
Transition Dwell Time |
127 |
Valve State |
128 |
Pressure |
129 |
Auxiliary/Pressure Switch 1 |
130 |
PST Cycle Count |
131 |
Break Away Time |
132 |
Analog Position |
133 |
Not Used |
134 |
Scratch Data |
135 |
Position of the valve as a percentage of travel. |
136 |
Analog Position Status |
137 |
Simulate |
138 |
Update Period |
139 |
Acquisition Period |
140 |
Rate at which the device variable is sampled and calculated. |
141 |
Device Variable Properties |
142 |
This Device Variable is calculated by the Field Device. |
143 |
.3f |
144 |
Minimum Span |
145 |
8.3f |
146 |
7d |
147 |
Device Variable is not calculated by Field Device |
148 |
Device Variable is setpoint or remote sensor value |
149 |
State of the attached dry contact limit switch. |
150 |
Limit Switch 1 Status |
151 |
None |
152 |
Limit Switch 2 Status |
153 |
Limit Switch 2 Discrete Status |
154 |
State of the attached auxiliary/pressure switch 2. |
155 |
Auxiliary/Pressure Switch 2 Status |
156 |
Current temperature of the device. |
157 |
Internal Device Temperature Status |
158 |
Accumulated time needed to complete the most recent stroke from opened to closed. |
159 |
Last Close Stroke Time Status |
160 |
seconds |
161 |
Accumulated time needed to complete the most recent stroke from closed to opened. |
162 |
Last Open Stroke Time Status |
163 |
Accumulated time the valve last spent in the open position. |
164 |
Open Dwell Time Status |
165 |
Accumulated time the valve last spent in the closed position. |
166 |
Close Dwell Time Status |
167 |
Indicates valve position i.e. Open, Closed, Opening, Closing, Stopped etc. |
168 |
Valve State Status |
169 |
Number of valve strokes based on change in valve direction. |
170 |
Cycle Count Status |
171 |
Highest ambient temperature seen by the device. |
172 |
Highest Device Temperature Status |
173 |
Lowest ambient temperature seen by the device. |
174 |
Lowest Device Temperature Status |
175 |
Accumulated time the valve last spent between the open and closed positions. |
176 |
Transition Dwell Time Status |
177 |
Pressure. |
178 |
Pressure Unit |
179 |
Pressure Status |
180 |
.2f |
181 |
Trim Point Units |
182 |
Units for the returned trim points |
183 |
Lower Trim Point |
184 |
Trim point written when lower process is applied to the sensor. |
185 |
Upper Trim Point |
186 |
Trim point written when higher process is applied to the sensor. |
187 |
Trim Points Supported |
188 |
Indicates whether or not the particular device variable supports trimming. |
189 |
Minimum Lower Trim Point Value |
190 |
Minimium lower trim value |
191 |
Maximum Lower Trim Point Value |
192 |
Maximium lower trim value |
193 |
Minimum Upper Trim Point Value |
194 |
Maximum Upper Trim Point Value |
195 |
Minimum Differential between Trim Points |
196 |
Minimium span between trim values. |
197 |
State of the attached auxiliary/pressure switch 1. |
198 |
Auxiliary/Pressure Switch 1 Status |
199 |
Number of PST Cycles. |
200 |
PST Cycle Count Status |
201 |
Time between solenoid deactivated and valve movement. |
202 |
Break Away Time Status |
203 |
Valve Mode |
204 |
Enables a 3% hysteresis around the open and closed endpoints. |
205 |
Linear Mode |
206 |
Rotary Mode (3% Deadband Enabled) |
207 |
Sensor Configuration |
208 |
Notifies the device of connect process sensors. |
209 |
Potentiometer Only |
210 |
Potentiometer + Limit Switches |
211 |
Calibration Mode |
212 |
Determines the configuration and overall operation of the valve/actuator. |
213 |
Two-Point Clockwise to Close |
214 |
Five-Point Clockwise to Close |
215 |
Two-Point Clockwise to Open |
216 |
Five-Point Clockwise to Open |
217 |
Slot |
218 |
Element slot in the calibration point data array. |
219 |
0% Position Calibration Slot |
220 |
100% (Two-Point) Position Calibration Slot |
221 |
Status Bit is not Supported by field device |
222 |
No Effect |
223 |
Maintenance Required |
224 |
PV Out of Limits |
225 |
Used to map a status condition to a severity level. |
226 |
Non-PV Out of Limits |
227 |
Loop Current Saturated |
228 |
Loop Current Fixed |
229 |
More Status Available |
230 |
Cold Start |
231 |
Configuration Changed |
232 |
Device Malfunction |
233 |
Device Variable Alert |
234 |
Critical Power Failure |
235 |
Device Variable Simulation Active |
236 |
Non-Volatile Memory Defect |
237 |
Volatile Memory Defect |
238 |
Watchdog Reset Executed |
239 |
Power Supply Conditions Out of Range |
240 |
Environmental Conditions Out of Range |
241 |
Electronics Defect |
242 |
Disabled |
243 |
Enabled |
244 |
Alert Simulation |
245 |
Allows simulation of different status conditions. |
246 |
Index into Status Array |
247 |
Reset |
248 |
Set |
249 |
Triggered Update Rate |
250 |
Triggered Update Rate - This defines how often the broadcast message is sent to the gateway after a user defined trigger level threshold has been crossed. Faster update rates have an impact on the total communications traffic on the network, and power module life. |
251 |
Default Update Rate |
252 |
Default Update Rate - This defines how often the broadcast message is sent to the gateway prior to crossing a user defined trigger level threshold. Faster update rates have an impact on the total communications traffic on the network, and power module life. |
253 |
Trigger Mode |
254 |
Trigger Level |
255 |
Burst Message 1 |
256 |
Message 1 Content |
257 |
Burst Option- Selects the variable(s) that will be Bursted if Burst Mode is enabled |
258 |
Cmd 48: Read Additional Device Status |
259 |
Read Additional Device - This command reads additional device status information |
260 |
Cmd 64386: Discrete Variables |
261 |
Burst Variable Code |
262 |
Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. |
263 |
1st and Trigger Variable |
264 |
2nd Variable |
265 |
3rd Variable |
266 |
4th Variable |
267 |
5th Variable |
268 |
6th Variable |
269 |
7th Variable |
270 |
8th Variable |
271 |
Burst Message 2 |
272 |
Message 2 Content |
273 |
Burst Message 3 |
274 |
Message 3 Content |
275 |
DD rev |
276 |
DD Revision - This revision corresponds to the device descriptor for this device that is installed in the host system. |
277 |
Cycle Count Limit |
278 |
Number valve cycles at which the Cycle Count Exceeded alert is activated. |
279 |
Open Dwell Time Upper Limit |
280 |
Upper trigger value for Open Dwell Time Alert. |
281 |
Open Dwell Time Lower Limit |
282 |
Lower trigger value for Open Dwell Time Alert. |
283 |
Transition Dwell Time Upper Limit |
284 |
Trigger value for Transition Dwell Time Alert. |
285 |
Closed Dwell Time Upper Limit |
286 |
Upper trigger value for Closed Dwell Time Alert. |
287 |
Closed Dwell Time Lower Limit |
288 |
Lower trigger value for Closed Dwell Time Alert. |
289 |
Last Open Stroke Time Upper Limit |
290 |
Upper trigger value for the Last Open Stroke Time Alert. |
291 |
Last Open Stroke Time Lower Limit |
292 |
Lower trigger value for the Last Open Stroke Time Alert. |
293 |
Last Close Stroke Time Upper Limit |
294 |
Upper trigger value for the Last Close Stroke Time Alert. |
295 |
Last Close Stroke Time Lower Limit |
296 |
Lower trigger value for the Last Close Stroke Time Alert. |
297 |
Highest Device Temperature Date |
298 |
Date of the highest temperature seen by the device. |
299 |
Lowest Device Temperature Date |
300 |
Date of the lowest temperature seen by the device. |
301 |
Zero Percent Valve State |
302 |
Sets the valve state when the position is 0%. Options are Open or Closed. |
303 |
Open |
304 |
Closed |
305 |
Discrete Valve Setpoint |
306 |
Fault State Mode |
307 |
Specifies the behavior of the discrete variable under fault conditions. |
308 |
Fault State Value |
309 |
Specifies the value to be asserted when the discrete variable is in the fault condition. |
310 |
Fault Timeout |
311 |
Shed time that must elapse before a fault condition causes the fault state action to be executed. |
312 |
Opened |
313 |
Limit Switch 1 Discrete Status |
314 |
Discrete Variable Simulation |
315 |
No Fault State |
316 |
Fail to Value |
317 |
Hold Last Value |
318 |
Auxiliary/Pressure Switch 2 Discrete Status |
319 |
Auxiliary/Pressure Switch 1 Discrete Status |
320 |
Close |
321 |
Opening |
322 |
Closing |
323 |
Fail |
324 |
Target Value of Discrete Valve State |
325 |
Discrete Valve Setpoint Status |
326 |
Discrete Variable |
327 |
Index of first Discrete Variable |
328 |
Discrete Variable Index of First Returned Variable |
329 |
|
330 |
Number of PLC Register Blocks |
331 |
DLEU Support |
332 |
No DLEU spported in this device |
333 |
DLEU spported in this device |
334 |
|
335 |
State |
336 |
Counter |
337 |
Packed |
338 |
Reserved |
339 |
Discrete Time Stamp |
340 |
Relative time value on network |
341 |
Discrete Variable Connection |
342 |
Indicates whether the variable is general purpose or has a direct connection to the plant. |
343 |
No plant connection |
344 |
Input from plant |
345 |
Output to plant |
346 |
Discrete Variable Classification |
347 |
Indicates the expected class of enumerated values the variable can take on. |
348 |
Not Classified |
349 |
On/Off Switch |
350 |
Limit Switch |
351 |
Motor |
352 |
Valve, NO |
353 |
Valve, NC |
354 |
Motor Operated Valve |
355 |
2 Spd Motor |
356 |
2 Direction Motor |
357 |
Elevator |
358 |
Tank |
359 |
Heat/Cool |
360 |
Wet/Dry |
361 |
Presence/Absence |
362 |
index to discrete variable returning actual value |
363 |
Status Simulation Byte |
364 |
Device Status |
365 |
Device Specific Status 0 |
366 |
Device Specific Status 1 |
367 |
Device Specific Status 2 |
368 |
Device Specific Status 3 |
369 |
Device Specific Status 4 |
370 |
Standardized Status 0 |
371 |
Standardized Status 1 |
372 |
Status Simulation Bits |
373 |
Loop Current Fixed |
374 |
Status Simulation Items |
375 |
Condensed status value |
376 |
Bit Index |
377 |
Index of first Discrete Variable to Write |
378 |
Discrete Variable Override Mode |
379 |
Discrete Variable Override Value |
380 |
Partial Stroke Time Tolerance |
381 |
Percent deviation from calibrated partial stroke time allowed for pass/fail. |
382 |
10% Tolerance |
383 |
20% Tolerance |
384 |
30% Tolerance |
385 |
40% Tolerance |
386 |
Break Away Time Tolerance |
387 |
Percent deviation from the calibrated break away time captured during full stroke calibration. |
388 |
Solenoid Voltage Tolerance |
389 |
Percent deviation from the calibrated Solenoid Voltage captured during full stroke calibration. |
390 |
Solenoid Current Tolerance |
391 |
Percent deviation from the calibrated Solenoid Current captured during full stroke calibration. |
392 |
Partial Stroke Position |
393 |
Partial stroke valve position limit. |
394 |
Partial Stroke Calibration Status |
395 |
Partial Stroke must be calibrated prior to executing a PST |
396 |
Failed - Timeout or Aborted |
397 |
Failed - Valve did not move during partial stroke test |
398 |
Failed - Valve traveled past calibrated partial stroke position |
399 |
In Progress |
400 |
Partial Stroke Test Status |
401 |
Partial Stroke Test results |
402 |
Failed - Valve partial stroke time outside allowed tolerance |
403 |
Failed - Break away time outside allowed tolerance |
404 |
Solenoid Electrical Characteristics outside allowed tolerance |
405 |
PST Pressure Out of limits |
406 |
Valve Signature Data |
407 |
Sample time is set during calibration. |
408 |
% |
409 |
PST Time |
410 |
Time taken to complete the last partial stroke test. |
411 |
Solenoid 1 Voltage |
412 |
Voltage at solenoid 1 terminals. |
413 |
Solenoid 2 Voltage |
414 |
Voltage at solenoid 2 terminals. |
415 |
Solenoid 1 Current |
416 |
Current flowing through solenoid 1. |
417 |
Solenoid 2 Current |
418 |
Current flowing through solenoid 2. |
419 |
Pilot/SOV Configuration |
420 |
Pilot Configuration Single/Dual/No Pilot. |
421 |
Single Pilot/SOV |
422 |
Dual Pilot/SOV |
423 |
No Pilot |
424 |
Valve Configuration |
425 |
Fail Clockwise to Closed |
426 |
Fail Clockwise to Open |
427 |
Fail Counter Clockwise to Closed |
428 |
Fail Counter Clockwise to Open |
429 |
Partial Stroke Timeout |
430 |
Maximum amout of time in seconds allowed for PST Calibration and PST to be completed once initiated. |
431 |
The number of times the partial stroke test has been completed. |
432 |
Time difference between solenoid activation and valve movement detection. |
433 |
Valve Signature Record Number |
434 |
Four valve signatures of each type may be stored in the device. One baseline signature with the other three for comparison. |
435 |
Baseline Record |
436 |
Record 1 |
437 |
Record 2 |
438 |
Record 3 |
439 |
Valve Signature Test Date |
440 |
This is the date for which the valve signature was stored into the device. |
441 |
Valve Signature Type |
442 |
Indicates the valve signature test type. |
443 |
PST Valve Signature |
444 |
Close Stroke Valve Signature |
445 |
Open Stroke Valve Signature |
446 |
Full Stroke Valve Signature |
447 |
Full Stroke Valve Signature Sample Time Calibration |
448 |
Data Set |
449 |
Valve Signature data. |
450 |
Solenoid Operated Valve Test Timeout |
451 |
Time allowed for the SOV test to complete. |
452 |
SOV Test Minimum Change |
453 |
Minimum travel the SOV shuttle must go to be considered successful. |
454 |
Abort |
455 |
This parameter is used to abort a valve signature test and a partial stroke test. |
456 |
No |
457 |
Yes |
458 |
Pressure Upper Alert Limit |
459 |
Determines what pressure must be exceeded for the field device alert to be triggered. |
460 |
Pressure Lower Alert Limit |
461 |
Determines what the pressure value must be below for the field device alert to be triggered. |
462 |
SOV Testing Configuration |
463 |
Enables or Disables the SOV Sensor. |
464 |
Pressure Transmitter 4-20 mA Input |
465 |
Pressure Switch Aux 1 Input |
466 |
SOV Position Sensor Aux 1 Input |
467 |
SOV Position Sensor Aux 1 Input + Pressure Transmitter 4-20 mA Input |
468 |
Option 5 (Not Valid in Configuration) |
469 |
Option 3 (Not Valid in Configuration) |
470 |
Option 4 (Not Valid in Configuration) |
471 |
Pressure Switch Aux 1 Input + Pressure Switch Aux 2 Input |
472 |
SOV Test Status |
473 |
SOV Test Results. |
474 |
Success |
475 |
Failed - SOV Test Failed |
476 |
Failed - SOV Test Timed Out |
477 |
Failed - SOV Test Aborted |
478 |
Failed - SOV Voltage/Current Out of Tolerance |
479 |
Failed - Pressure Out of Tolerance Limits |
480 |
SOV Config Error |
481 |
SOV Test Complete |
482 |
Pressure Sensor Configuration |
483 |
Enables or Disables the Pressure Sensor. |
484 |
Pressure Limit Units |
485 |
PST Mode |
486 |
Enables or disables the Partial Stroke Feature. |
487 |
ESD Mode |
488 |
Enables or disables the Emergency Shutdown feature. |
489 |
ESD HART 7 |
490 |
ESD Discrete |
491 |
Valve Signature Mode |
492 |
Enables or disables the Valve Signature feature. |
493 |
Password |
494 |
Factory use only. |
495 |
Valve Signature Test Status |
496 |
Valve Signature Test Results. |
497 |
Failed - Valve did not move during test |
498 |
Stroke Test in Progress |
499 |
Buffering Data |
500 |
Percent of Test Completed |
501 |
Pecent of the current test that has been completed. |
502 |
PST Upper Pressure |
503 |
High pressure measurement during PST. |
504 |
PST Lower Pressure |
505 |
Low pressure measurement during PST. |
506 |
Pressure Alert Limit Units |
507 |
Specifies the units of the pressure alert limit values being written to the device. |
508 |
PST Pressure Upper Alert Limit |
509 |
PST Pressure Lower Alert Limit |
510 |
PST Pressure Units |
511 |
Specifies the units of the PST pressure values being written to the device. |
512 |
Valve Signature Per Data Point Time |
513 |
Rate at which the valve signature is recorded. |
514 |
Communications |
515 |
Simulation Status |
516 |
Device Information |
517 |
Upper Sensor Limit |
518 |
Analog Position |
519 |
Analog Position |
520 |
Analog Output |
521 |
Percent of Range |
522 |
Primary Variable Status |
523 |
Secondary Variable Status |
524 |
Tertiary Variable Status |
525 |
Quaternary Variable Status |
526 |
Analog Position |
527 |
Internal Device Temperature |
528 |
Pressure |
529 |
Position |
530 |
Limit Switch 1 |
531 |
Limit Switch 2 |
532 |
Auxiliary/Pressure Switch 2 |
533 |
Internal Device Temperature |
534 |
Internal Device Temperature |
535 |
Last Close Stroke Time |
536 |
Last Open Stroke Time |
537 |
Open Dwell Time |
538 |
Close Dwell Time |
539 |
Cycle Count |
540 |
Highest Device Temperature |
541 |
Lowest Device Temperature |
542 |
Transition Dwell Time |
543 |
Valve State |
544 |
Pressure |
545 |
Auxiliary/Pressure Switch 1 |
546 |
PST Cycle Count |
547 |
Break Away Time |
548 |
Data Points |
549 |
FS Valve Signature Data |
550 |
Valve Signature Data: Baseline Record |
551 |
PS Valve Signature Data |
552 |
Overview |
553 |
Configure |
554 |
Service Tools |
555 |
Manual Setup |
556 |
Guided Setup |
557 |
Status |
558 |
Primary Purpose Variables |
559 |
Shortcuts |
560 |
Identification |
561 |
Device Identification |
562 |
Revisions |
563 |
Revision Numbers |
564 |
Communication Statistics |
565 |
Security and Simulation |
566 |
HART Lock (Software) |
567 |
Simulation |
568 |
Initial Setup |
569 |
Configures the valve's calibrated operating range. |
570 |
Configures the threshold configuration. |
571 |
Configures the partial stroke calibration parameters. |
572 |
Initiates partial stroke test. |
573 |
Runs SOV diagnostic test. |
574 |
Stores valve signatures. |
575 |
Device Variable Thresholds |
576 |
Accumulated Cycle Count Thresholds |
577 |
Dwell Time Thresholds |
578 |
Stroke Time Thresholds |
579 |
Solenoid Thresholds |
580 |
PST |
581 |
Alert Limits |
582 |
Partial Stroke |
583 |
Discrete Variables |
584 |
Device Configurations |
585 |
Mode Selection |
586 |
Solenoid |
587 |
Pressure Transmitter |
588 |
Valve Signature Configuration |
589 |
Temperature Units |
590 |
Clock |
591 |
System Time |
592 |
Note: Real time clock date and time were last set on 'Set Clock Date' and at 'Set Clock Time'. |
593 |
HART |
594 |
Communication Settings |
595 |
Variable Mapping |
596 |
Burst Mode Configuration |
597 |
Configures triggers, rates and event conditions for broadcast messages. |
598 |
View Message 1 Configuration |
599 |
Message 1 Configuration |
600 |
View Message 2 Configuration |
601 |
Message 2 Configuration |
602 |
View Message 3 Configuration |
603 |
Message 3 Configuration |
604 |
View Event Notification Configuration |
605 |
Event Notification Timing |
606 |
Event Notification Configuration |
607 |
Event Notifications help identify abnormal device conditions by sending a burst message. Alert status change of checked bits will trigger an event notification. |
608 |
Configure Message 1 |
609 |
Choose the message content below. |
610 |
Broadcast Configuration |
611 |
Burst Rate |
612 |
Configure Message 2 |
613 |
Configure Message 3 |
614 |
Security |
615 |
Configure Event Notification |
616 |
Event Notifications help identify abnormal device conditions by sending a burst message. Select the alerts whose status change will trigger an event notification. |
617 |
Adjust values for Event Debounce Interval and Event Notification Retry Time if required. Event Debounce Interval is the time that the alert(s) have to be active to trigger an event notification.Event Notification Retry Time is the time that the event notification will continue to appear until acknowledged through the host. |
618 |
Alerts |
619 |
Active Alerts |
620 |
No Active Alerts |
621 |
Recommended Actions:
1. Reset the device.
2. Contact factory if the alert persists. |
622 |
Recommended Action:
1. Complete the calibration method. |
623 |
Recommended Actions:
1. Stroke must be greater than 20 Degrees.
2. Recalibrate the valve span. |
624 |
Recommended Actions:
1. Valve maintenance is recommended.
2. Readjust or reset the 'Cycle Count Limit' parameter. |
625 |
Recommended Action:
1. Execute the DAC trim method for trimming the loop current to the proper value against a calibrated current meter. |
626 |
Recommended Action:
1. Calibrate the valve stroke into the device by running the calibration method. |
627 |
Recommended Actions:
1. Valve maintenance is recommended.
2. Adjust the limits according to the valves stroke time. |
628 |
Recommended Action:
1. Stroke/Partially stroke the valve to reset the timer, clear the counter manually,increase the limit. |
629 |
Recommended Action:
1. Stroke/Partially stroke the valve to reset the timer, clear the counter manually,increase the limit. |
630 |
Recommended Actions:
1. Ensure loop power is properly supplied.
2. Reset the device (Service Tools - Maintenance - Reset/Restore).
3. If the process allows, cycle the HART power.
4. If the process allows, cycle the pilot power.
5. Replace main module if there is continued loss of any function. |
631 |
Recommended Actions:
1. Reset the device.
2. Ensure loop power is properly supplied. |
632 |
Recommended Action:
1. Check the wiring connections for the positions sensor/potentiometer. |
633 |
Recommended Action:
1. Check the wiring connections for each limit switch. |
634 |
Recommended Actions:
1. Valve maintenance is recommended.
2. Adjust the limits according to the transition dwell time. |
635 |
Device variables are being simulated. |
636 |
Recommended Action:
1. Disable Device Variable Simulation mode. |
637 |
FRAM Uncorrectable bit Error |
638 |
Recommended Actions:
1. Reset the device.
2. Contact the factory if the problem persists. |
639 |
RAM/Code overwrite Error. Microprocessor Stack Overflow. |
640 |
Code execution has exceeded the WDT timer limit. |
641 |
Recommended Action:
1. Reset the device. |
642 |
Regulated power supply voltage is out of range. |
643 |
Recommended Action:
1. Verify the bus voltage is in range. |
644 |
Internal Temperature outside -40 to 80 degC. |
645 |
Recommended Action:
1. Ensure the environmental conditions are appropriate for the device. |
646 |
Internal electronics failure. |
647 |
Recommended Action:
1. Contact the factory. |
648 |
Recommended Action:
1. Disable Status Simulation mode. |
649 |
Recommended Action:
1. Disable Discrete Variable Simulation mode. |
650 |
Recommended Actions:
1. The device buffers 3 unacknowledged events.
2. Ensure the host acknowledges the events in a timely manner. |
651 |
The device is in multi-drop mode or the loop current is set to a fixed level and is not responding to process inputs. |
652 |
Recommended Action:
1. If analog loop current signaling is desired disable multi-drop mode. |
653 |
Recommended Actions:
1. Verify the supply pressure.
2. Verify the actuator for proper operation. |
654 |
Recommended Action:
1. Power cycle the unit. |
655 |
Recommended Action:
1. Check solenoid power supply and mechanical operation. |
656 |
Variables |
657 |
Mapped Variables |
658 |
Primary Variable |
659 |
Secondary Variable |
660 |
Tertiary Variable |
661 |
Quaternary Variable |
662 |
Other Variables |
663 |
Auxiliary Switches |
664 |
Limit Switches |
665 |
Device Variables |
666 |
Temperatures |
667 |
Stroke Times |
668 |
Dwell Times |
669 |
Accumulated Valve Cycle Count |
670 |
Trends |
671 |
Valve Signature |
672 |
Displays 'Valve Signature' graph for Full Stroke Test Signature. |
673 |
Displays 'Valve Signature' graph for Partial Stroke Test Signature. |
674 |
Valve Signature Data Graph for FS Test |
675 |
Valve Signature Data Graph for PS Test |
676 |
Maintenance |
677 |
Calibration |
678 |
Device Calibration |
679 |
Sensor Calibration |
680 |
Calibrates the pressure sensor (Lower Trim). |
681 |
Calibrates the pressure sensor (Upper Trim). |
682 |
Calibrates the pressure sensor (Zero Trim). |
683 |
Resets trim points to default settings. |
684 |
Routine Maintenance |
685 |
Calibrates the 4 mA and 20 mA analog points of the primary variable. |
686 |
Allows the user to manually manipulate
the Analog Output to a selected constant output value. |
687 |
Changes loop current mode. |
688 |
SOV |
689 |
Re-Range PV |
690 |
Reset/Restore |
691 |
Resets the device without losing configuration (user configuration is preserved). |
692 |
Resets the device to default settings (user configuration not preserved). |
693 |
Resets the Emergency Shutdown Alarm. |
694 |
Resets accumulated cycle count. |
695 |
Resets PST cycle count. |
696 |
Select the alert to simulate. |
697 |
Simulate device variables by clicking on the appropriate button. |
698 |
Device Temperature |
699 |
Valve Position |
700 |
Simulate discrete variables by clicking on the appropriate button. |
701 |
Valve Position Status |
702 |
Failed |
703 |
Process |
704 |
Electronics |
705 |
Recommended Actions:
1. Check the wiring connections to the pressure sensor.
2. Verify the sensor operates correctly. |
706 |
Recommended Action:
1. Run the Partial Stroke Calibration method. |
707 |
Advisory |
708 |
Recommended Action:
1. Check the voltage across the terminals of Solenoid 1. |
709 |
Recommended Action:
1. Check the current through the coil of Solenoid 1. |
710 |
Recommended Action:
1. Check the voltage across the terminals of Solenoid 2. |
711 |
Recommended Action:
1. Check the current through the coil of Solenoid 2. |
712 |
Recommended Actions:
1. Valve maintenance may be required.
2. Verify operation. |
713 |
Recommended Action:
1. Check the operation of the SOV ( Solenoid Operated Valve). |
714 |
Recommended Actions:
1. Verify event with Safety Instrumented System (SIS).
2. Reset alert via AMS. |
715 |
Recommended Actions:
1. Verify supply pressure is not above Upper Pressure Limit parameter. |
716 |
Recommended Actions:
1. Verify supply pressure is not below Lower Pressure Limit parameter. |
717 |
Offline |
718 |
'Pressure Sensor Configuration' must be 'Enabled'. |
719 |
Download Variables |
720 |
Upload Variables |
721 |
Upload from Device |
722 |
Download to Device |
723 |
Device Status: Good |
724 |
Device Status: Failure - Fix Now |
725 |
Device Status: Function Check |
726 |
Device Status: Out of Specification - Fix Soon |
727 |
Simulation Active |
728 |
Comm Status |
729 |
Burst |
730 |
Polled |
731 |
Configure Adv Brdcst |
732 |
Event Notification |
733 |
Device is unlocked |
734 |
Device is locked |
735 |
Note: Please run 'Update Valve Signature Data Graph Settings' before reading 'Valve Signature Record Number' and 'Valve Signature Per Data Point Time'. |
736 |
Starting Status Map Index must be even value. |
737 |
Span Too Small |
738 |
Invalid Stroke Rotation |
739 |
Setpoint in Deadband |
740 |
Valve Movement Not Detected |
741 |
Invalid Simulated Value |
742 |
Discrete Variable being simulated or overridden |
743 |
Invalid Override Mode |
744 |
Invalid Override Value |
745 |
Invalid Discrete Variable Index. The Discrete Variable Does Not Exist In This Field |
746 |
Invalid Discrete Variable Code |
747 |
Invalid Fault State Mode |
748 |
Invalid Fault State Value |
749 |
Discrete Setpoint Variable Overridden |
750 |
Full Stroke Position Calibration Required |
751 |
Valve not at 100% position |
752 |
Partial Stroke Test in progress |
753 |
Partial Stroke Calibration in progress |
754 |
Full Stroke Test in Progress |
755 |
Feature Not Enabled |
756 |
Parial Stroke Calibration In Progress |
757 |
Valve Signature Mode Disabled |
758 |
Baseline Signature not Stored |
759 |
SOV Test in Progress |
760 |
Stroke Times are being simulated |
761 |
Full Valve Cycle Required |
762 |
4-20 mA Pressure Sensor not enabled |
763 |
Full Stroke Calibration Required |
764 |
Stroke Times Must be Stored for FST |
765 |
Valve Signature Test in Progress |
766 |
Invalid Units Code |
767 |
Configure Advanced Broadcasting |
768 |
Full Stroke Position Calibration |
769 |
Stop Finding Device |
770 |
Locate Device |
771 |
Locate Device - Identify this device by showing a unique pattern (0-0-0-0) on the device display. This pattern will persist until the Find Device procedure is finished. |
772 |
Change Clock Date and Time |
773 |
Lock/Unlock |
774 |
Processor Reset |
775 |
Change Polling Address |
776 |
Changes the Polling Address |
777 |
Change Loop Current Mode |
778 |
Factory Reset |
779 |
Threshold Configuration |
780 |
Full Stroke Cycle Count Reset |
781 |
PST Cycle Count Reset |
782 |
Disable Simulation |
783 |
Disables Alert Simulation |
784 |
Simulate Alerts |
785 |
Disable Status Simulation |
786 |
Loop Test |
787 |
Allows the user to manually manipulate the Analog Output to a selected constant output value. |
788 |
Variable Summary |
789 |
DAC Trim |
790 |
Refresh Alerts |
791 |
Alert Description |
792 |
Partial Stroke Calibration |
793 |
This method is used to calibrate for a partial stroke test. |
794 |
Partial Stroke Test |
795 |
This method is used to initiate a partial stroke test. |
796 |
SOV Test |
797 |
Valve Signature Test |
798 |
ESD Alarm Reset |
799 |
Test |
800 |
Valve Signature Data Graph Settings |
801 |
Update Valve Signature Data Graph Settings |
802 |
Initiate PS |
803 |
Initiate FS |
804 |
Initiate FS Baseline |
805 |
Pressure Sensor Lower Trim |
806 |
Pressure Sensor Upper Trim |
807 |
Pressure Sensor Zero Trim |
808 |
Reset Pressure Sensor Trim |
809 |
DD Version Information |
810 |
Initiate PS baseline |
811 |
Get Health Status |
812 |
PV Analog Channel Saturated |
813 |
PV Analog Channel Fixed |
814 |
Wireless |
815 |
WirelessHART Device |
816 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
817 |
Primary |
818 |
Primary Analog Channel |
819 |
Secondary |
820 |
Secondary Analog Channel |
821 |
Tertiary |
822 |
Tertiary Analog Channel |
823 |
Quaternary |
824 |
Quaternary Analog Channel |
825 |
Quinary |
826 |
Quinary Analog Channel |
827 |
Lock all |
828 |
Trim not supported |
829 |
Configuration cannot be changed |
830 |
Locked by gateway |
831 |
Analog Input Channel |
832 |
Analog Output Channel |
833 |
Secondary Analog Channel Saturated |
834 |
Tertiary Analog Channel Saturated |
835 |
Quaternary Analog Channel Saturated |
836 |
Quinary Analog Channel Saturated |
837 |
Secondary Analog Channel Fixed |
838 |
Tertiary Analog Channel Fixed |
839 |
Quaternary Analog Channel Fixed |
840 |
Quinary Analog Channel Fixed |
841 |
Simulation active |
842 |
The device is in simulation mode and the level output is not representative of the process. |
843 |
Non-Volatile memory failure |
844 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
845 |
Volatile memory error |
846 |
The RAM memory check is invalid or maybe corrupt |
847 |
Watchdog reset executed |
848 |
A watchdog reset has been performed |
849 |
Voltage conditions out of range |
850 |
A voltage condition is outside its allowable range |
851 |
Environmental conditions out of range |
852 |
An internal or environmental condition is beyond acceptable limits. |
853 |
Electronic failure |
854 |
A hardware problem not related to the sensor has been detected. |
855 |
Subdevice list changed |
856 |
Duplicate master detected |
857 |
Capacity Denied |
858 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
859 |
Bandwidth allocation pending |
860 |
Block transfer pending |
861 |
Battery life |
862 |
Percent range |
863 |
Loop current |
864 |
Primary variable |
865 |
Secondary variable |
866 |
Tertiary variable |
867 |
Quaternary variable |
868 |
Read receive time |
869 |
Write date and time |
870 |
Non-Volatile Clock |
871 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
872 |
Clock Uninitialized |
873 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
874 |
No restrictions |
875 |
SI Only |
876 |
Restricted to SI Unit codes only |
877 |
Process automation device |
878 |
Discrete device |
879 |
Hybrid:Process automation+discrete |
880 |
I/O System |
881 |
WirelessHART Process automation device |
882 |
WirelessHART Discrete device |
883 |
WirelessHART Process automation+discrete |
884 |
WirelessHART Gateway |
885 |
WirelessHART Access point |
886 |
WirelessHART Process adapter |
887 |
WirelessHART Discrete adapter |
888 |
WirelessHART enabled handheld/portable maintenance tool |
889 |
Device Profile |
890 |
US |
891 |
United States of America |
892 |
JP |
893 |
Japan |
894 |
DE |
895 |
Germany |
896 |
FR |
897 |
France |
898 |
ES |
899 |
Spain |
900 |
RU |
901 |
Russian Federation |
902 |
CN |
903 |
People's Republic of China |
904 |
Secondary Master |
905 |
Primary Master |
906 |
Device Diagnostic Status 0 |
907 |
Device Diagnostic Status 1 |
908 |
I/O and Subdevice Status |
909 |
WirelessHART Status |
910 |
Time Set Option |
911 |
Real Time Clock Flags |
912 |
Country |
913 |
Country of intended device installation |
914 |
SI Unit Control |
915 |
Indicates if device should only display SI unit codes |
916 |
Burst Trigger Units |
917 |
Enable on token-passing data link layer only |
918 |
Enable on TDMA data link layer only |
919 |
Enable on both TDMA and token-passing data link layer |
920 |
Burst Trigger Class |
921 |
Continuous |
922 |
The Burst Message is published continuously at (worst case) the Minimum Update Period. |
923 |
Window |
924 |
The Burst Message is triggered when the source value deviates more than the specified trigger value |
925 |
Rising |
926 |
The Burst Message is triggered when source value Rises Above the specified trigger value. |
927 |
Falling |
928 |
The Burst Message is triggered when the source value Falls Below the specified trigger value. |
929 |
On-change |
930 |
The Burst Message is triggered when any value in the message changes. |
931 |
Off |
932 |
Enable event notification on token-passing data link layer |
933 |
Enable event notification on TDMA data link layer |
934 |
Enable event notification on TDMA and token-passing data link layer |
935 |
Configuration changed event pending |
936 |
Device status event pending |
937 |
More status available event pending |
938 |
Wired HART Enabled |
939 |
Enabled on Wired HART device connection only |
940 |
Wireless HART Enabled |
941 |
Enabled on WirelessHART device connection only |
942 |
Both Wired and WirelessHart Enabled |
943 |
Enabled on both Wired and WirelessHART connections |
944 |
Burst Msg Trigger Mode |
945 |
Event Status |
946 |
Event Notification Control |
947 |
Device Status Mask |
948 |
Ext dev status Mask |
949 |
Device Diagnostic Status 0 Mask |
950 |
Device Diagnostic Status 1 Mask |
951 |
Device Diagnostic Status 2 Mask |
952 |
Device Diagnostic Status 3 Mask |
953 |
AO saturated Mask |
954 |
AO fixed Mask |
955 |
Latched Device Status |
956 |
Operate mode Mask |
957 |
Not Defined |
958 |
Latched Ext dev status |
959 |
Latched Device Diagnostic Status 0 |
960 |
Latched Device Diagnostic Status 1 |
961 |
Latched Device Diagnostic Status 2 |
962 |
Latched Device Diagnostic Status 3 |
963 |
Latched AO saturated |
964 |
Latched AO fixed |
965 |
Latched Operate Mode |
966 |
Time Stamp |
967 |
8u |
968 |
Dynamic Variables Returned for Device Variables |
969 |
Command Response Truncated |
970 |
Configuration Change Counter Mismatch |
971 |
Status bytes mismatch |
972 |
Update time adjusted |
973 |
Invalid burst message |
974 |
Invalid device variable classification |
975 |
Invalid burst trigger mode selection code |
976 |
Burst condition conflict |
977 |
Update period increased |
978 |
Insufficient bandwidth |
979 |
Update period or debounce interval adjusted |
980 |
Update times adjusted |
981 |
Update rate uncertain |
982 |
Not all events cleared |
983 |
Device Variable |
984 |
Variable to trim |
985 |
Burst Message Number |
986 |
Update period for burst message |
987 |
5.3f |
988 |
Max Update Period |
989 |
Maxium update period for burst message |
990 |
Time First Unack Event Triggered |
991 |
The time when the first unacknowledged event was triggered |
992 |
Event Notification Retry Time |
993 |
Max Update Time |
994 |
Event Debounce Interval |
995 |
Set Clock Date |
996 |
Date to set the real-time clock in the field device to, or date that the real-time clock was last set |
997 |
Set Clock Time |
998 |
Time to set the real time clock in the field device to, or time that the real-time clock was last set |
999 |
Current Date |
1000 |
Current Date based upon the real-time clock in the field device |
1001 |
Current Time |
1002 |
Current Time based upon the real-time clock in the field device |
1003 |
Total Burst Msgs |
1004 |
Total number of burst messages supported by this device |
1005 |
Burst Command |
1006 |
Burst Trigger Level |
1007 |
Event Number |
1008 |
Number of Events Supported |
1009 |
Device Specific Status 0 Mask |
1010 |
Device Specific Status 1 Mask |
1011 |
Device Specific Status 2 Mask |
1012 |
Device Specific Status 3 Mask |
1013 |
Device Specific Status 4 Mask |
1014 |
Device Specific Status 5 Mask |
1015 |
Latched Device Specific Status 0 |
1016 |
Latched Device Specific Status 1 |
1017 |
Latched Device Specific Status 2 |
1018 |
Latched Device Specific Status 3 |
1019 |
Latched Device Specific Status 4 |
1020 |
Latched Device Specific Status 5 |
1021 |
Latched Cfg chng count |
1022 |
STX Count |
1023 |
Count of STX messages received by this device |
1024 |
ACK Count |
1025 |
Count of ACK messages received by this device |
1026 |
BACK Count |
1027 |
Count of BACK messages received by this device |
1028 |
HART Lock is active. This prevents any configuration changes from being made to the device. |
1029 |
Warning - Loop should be removed from automatic control. |
1030 |
Communicating with field device, please wait. |
1031 |
Confirm if the host system is able to accept messages before proceeding with the configuration.
Select an option to proceed: |
1032 |
Configure Message 1;Configure Message 2;Configure Message 3;Disable All Messages;Configure Event Notification;Exit |
1033 |
Next |
1034 |
select |
1035 |
Write Protection is enabled, it must be disabled to configure message 1 details. |
1036 |
Burst Message 1 configuration failed. |
1037 |
Messages 1 has been successfully disabled. |
1038 |
Back;Next |
1039 |
The trigger level is outside of valid range. Please select a new trigger level. |
1040 |
Incompatible trigger mode was selected, switching to continuous trigger. |
1041 |
Device Variable Classification corrected to match Device Variable being triggered on. |
1042 |
Burst Message 1 was successfully configured. |
1043 |
Burst Message 2 configuration failed. |
1044 |
Write Protection is enabled, it must be disabled to configure message 2 details. |
1045 |
Messages 2 has been successfully disabled. |
1046 |
Burst Message 2 was successfully configured. |
1047 |
Burst Message 3 configuration failed. |
1048 |
Write Protection is enabled, it must be disabled to configure message 3 details. |
1049 |
Messages 3 has been successfully disabled. |
1050 |
Burst Message 3 was successfully configured. |
1051 |
Changing burst configuration - This may take several minutes... |
1052 |
The delayed response mechanism took too long, configuration has not been completed. |
1053 |
HART Lock is enabled, it must be disabled to configure advanced broadcasting. |
1054 |
All Messages has been successfully disabled. |
1055 |
Note: Burst message needs to be configured in order to configure event notification. |
1056 |
Write Protection is enabled, it must be disabled to configure event notification. |
1057 |
Event Notification configuration failed. |
1058 |
Event Notification Configuration has been saved. |
1059 |
Note-Loop may be returned to automatic control. |
1060 |
Warning - This will modify the valve's calibrated operating range. |
1061 |
Warning - Device is about to be Temporarily HART locked for exclusive access during configuration. |
1062 |
Select the 'Sensor Configuration': |
1063 |
Potentiometer + Limit Switches;Potentiometer Only |
1064 |
Select the 'Valve Configuration': |
1065 |
Warning - The process valve is about to be placed in it's normal position.
Please ensure it is safe to do so before proceeding. |
1066 |
Setting valve to it's normal position, please wait. |
1067 |
If equiped, adjust the target(s) to activate the 0% limit switch(es). |
1068 |
Valve rotation direction does not match the valve calibration mode setting. Do you wish to try again? |
1069 |
Yes;No |
1070 |
Removing HART lock... |
1071 |
Selected setpoint is in the position sensor's deadband. Do you wish to try again? |
1072 |
Valve momement not detected. Do you wish to try again? |
1073 |
Minimum span error between calibration points. Valve rotation between setpoints must be greater than 20 degrees for a 2-point calibration. Do you wish to try again? |
1074 |
Warning - The process valve is about to be placed at the 100% position.
Please ensure it is safe to do so before proceeding. |
1075 |
Setting valve to the 100% position, please wait. |
1076 |
If equiped, adjust the target(s) to activate the 100% limit switch(es). |
1077 |
Select the 'Valve Mode': |
1078 |
Rotary Mode (3% Deadband Enabled);Linear Mode |
1079 |
'Valve Signature Mode' is enabled for this device. The valve will now cycle to record the Full Stroke Valve Signature time required for Valve Signature testing. |
1080 |
Warning - The process valve is about to cycle automatically. Please ensure it is safe to do so before proceeding. |
1081 |
Valve Signature Test is in progress, please wait. |
1082 |
Removing HART lock.
Valve Signature Result: Successful |
1083 |
Removing HART lock.
Valve Signature Result: %{valve_signature_test_status}. |
1084 |
Full Stroke Position Calibration is completed successfully. |
1085 |
Partial Stroke Calibration is required after Full Stroke Calibration. Do you want to proceed with Partial Stroke Calibration? |
1086 |
'Valve Signature Mode' is disabled, please enable before proceeding if 'Valve Signature' is required. |
1087 |
Removing HART lock, Full Stroke Position Calibration is completed successfully. |
1088 |
It will take approximately 90 seconds until the display is returned to normal operation. Pressing any of the local buttons will also return the device to normal operation. |
1089 |
This procedure will help to identify the device in the field by showing 0-0-0-0 pattern on the device display. In addition, both the Red and Green LEDs will begin flashing.
Select 'Next' to start. |
1090 |
The device will continue to display the pattern until the Locate Device sequence is concluded by pressing 'Cancel'. |
1091 |
The device was not found in the field. |
1092 |
Aborting - Write Protection is enabled, it must be disabled prior to this operation. |
1093 |
Enter date in MM/DD/YYYY format. |
1094 |
Enter time in 24 hour format (HH:MM:SS). |
1095 |
If 'Permanent Lock' is selected, only the locking master can unlock. Device processor reset or power loss does not affect the lock.
If 'Temporary Lock' is selected, only the locking master can unlock. Device reset or power loss releases the lock.
If 'Lock All' is selected, no changes in the device's configuration, by any master, are allowed. In addition, device processor reset or power loss does not affect the lock. Any master can unlock.
Select lock option: |
1096 |
Permanent;Temporary;Lock All |
1097 |
Cannot unlock device.
Device is locked by other host. |
1098 |
Cancel, do not reset this device.;Continue, reset this device. |
1099 |
Processor Reset is in progress, please wait. |
1100 |
Processor Reset is completed successfully. |
1101 |
Enter the 'Polling Address'. |
1102 |
The value of the 'Polling Address' should be between 0 and 63. |
1103 |
Choose the 'Loop Current Mode'. |
1104 |
'Loop Current Mode' has been set to '%{loop_current_mode}'. |
1105 |
Warning - Some user settings will be modified back to factory default values.
Do you wish to continue with 'Factory Reset' settings? |
1106 |
Factory Reset is in progress, please wait. |
1107 |
Factory Reset is completed successfully. |
1108 |
Warning - This will modify the Threshold Configuration. |
1109 |
Enter the 'Cycle Count Limit'. |
1110 |
Enter the 'Open Dwell Time Upper Limit'. |
1111 |
Enter the 'Open Dwell Time Lower Limit'. |
1112 |
Enter the 'Closed Dwell Time Upper Limit'. |
1113 |
Enter the 'Closed Dwell Time Lower Limit'. |
1114 |
Enter the 'Transition Dwell Time Upper Limit'. |
1115 |
Enter the 'Last Open Stroke Time Upper Limit'. |
1116 |
Enter the 'Last Open Stroke Time Lower Limit'. |
1117 |
Enter the 'Last Close Stroke Time Upper Limit'. |
1118 |
Enter the 'Last Close Stroke Time Lower Limit'. |
1119 |
Select the 'Break Away Time Tolerance': |
1120 |
Select the 'Solenoid Voltage Tolerance': |
1121 |
Select the 'Solenoid Current Tolerance': |
1122 |
Enter the 'Pressure Upper Alert Limit'. |
1123 |
Enter the 'Pressure Lower Alert Limit'. |
1124 |
Enter the 'Solenoid Operated Valve Test Timeout'. |
1125 |
Enter the 'SOV Test Minimum Change'. |
1126 |
Threshold Configuration is completed successfully. |
1127 |
This method will reset the accumulated 'Cycle Count'.
Select 'Next' to start. |
1128 |
Full Stroke Cycle Count Reset is in progress, please wait. |
1129 |
Full Stroke Cycle Count Reset is completed successfully. |
1130 |
This method will reset the 'PST Cycle Count'.
Select 'Next' to start. |
1131 |
PST Cycle Count Reset is in progress, please wait. |
1132 |
PST Cycle Count Reset is completed successfully. |
1133 |
Enter a fixed value (simulated value) for 'Last Open Stroke Time'. |
1134 |
'Last Open Stroke Time' is fixed at %{0} %{1}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1135 |
Enter a fixed value (simulated value) for 'Last Close Stroke Time'. |
1136 |
'Last Close Stroke Time' is fixed at %{0} %{1}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1137 |
Enter a fixed value (simulated value) for 'Open Dwell Time'. |
1138 |
'Open Dwell Time' is fixed at %{0} %{1}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1139 |
Enter a fixed value (simulated value) for 'Transition Dwell Time'. |
1140 |
'Transition Dwell Time' is fixed at %{0} %{1}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1141 |
Enter a fixed value (simulated value) for 'Close Dwell Time'. |
1142 |
'Close Dwell Time' is fixed at %{0} %{1}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1143 |
Enter a fixed value (simulated value) for 'Highest Device Temperature'. |
1144 |
'Highest Device Temperature' is fixed at %{0} %{1}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1145 |
Enter a fixed value (simulated value) for 'Internal Device Temperature'. |
1146 |
'Internal Device Temperature' is fixed at %{0} %{1}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1147 |
Enter a fixed value (simulated value) for 'Lowest Device Temperature'. |
1148 |
'Lowest Device Temperature' is fixed at %{0} %{1}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1149 |
Enter a fixed value (simulated value) for 'Cycle Count'. |
1150 |
'Cycle Count' is fixed at %{0} %{1}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1151 |
Enter a fixed value (simulated value) for 'Analog Position'. |
1152 |
'Analog Position' is fixed at %{0} %{1}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1153 |
Enter a fixed value (simulated value) for 'Pressure'. |
1154 |
'Pressure' is fixed at %{0} %{1}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1155 |
Select an option to simulate 'Limit Switch 1': |
1156 |
'Limit Switch 1' is fixed at %{0}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1157 |
Select an option to simulate 'Limit Switch 2': |
1158 |
'Limit Switch 2' is fixed at %{0}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1159 |
Select an option to simulate 'Auxiliary/Pressure Switch 2': |
1160 |
'Auxiliary/Pressure Switch 2' is fixed at %{0}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1161 |
Select an option to simulate 'Valve State': |
1162 |
'Valve State' is fixed at %{0}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1163 |
Alert simulation mode is disabled. |
1164 |
This method will put the device into status simulation mode.
Device diagnostics may not be available while the status is being simulated.
Do you want to simulate status now? |
1165 |
Yes - Continue with status simulation;No - Cancel |
1166 |
Which status byte do you want to simulate?
(Please refer IOM for details regarding each selection) |
1167 |
Which alert do you want to simulate? |
1168 |
Do you want to simulate this status as being Reset or Set? |
1169 |
Do you want to simulate more status? |
1170 |
Yes - Simulate more status;No - End Simulation |
1171 |
Select an option to disable simulation. |
1172 |
Disable Alert Simulation;Disable Device Variable Simulation;Disable Discrete Variable Simulation;Exit |
1173 |
Choose the 'Analog Output' level. |
1174 |
4 mA;20 mA;Custom;Exit |
1175 |
The 'Analog Output' is fixed at %[.3f]{0} mA. |
1176 |
Fix the 'Analog Output' at. |
1177 |
Returning field device to original output. |
1178 |
Analog Position:
Value: %{positionValue}%{positionUnits}
Status: %{positionPDQ}
Limit Switch 1:
Value: %{LimitSwitch1Value}
Status: %{LimitSwitch1PDQ}
Limit Switch 2:
Value: %{LimitSwitch2Value}
Status: %{LimitSwitch2PDQ}
Auxiliary Limit Switch:
Value: %{AuxiliaryLimitSwitchValue}
Status: %{AuxiliaryLimitSwitchPDQ}
Internal Device Temperature:
Value: %{internaldevicetemperatureValue}%{internaldevicetemperatureUnits}
Status: %{internaldevicetemperaturePDQ}
Last Close Stroke Time:
Value: %{last_close_stroke_timeValue}%{last_close_stroke_timeUnits}
Status: %{last_close_stroke_timePDQ}
Last Open Stroke Time:
Value: %{last_open_stroke_timeValue}%{last_open_stroke_timeUnits}
Status: %{last_open_stroke_timePDQ}
Open Dwell Time:
Value: %{opened_dwellValue}%{opened_dwellUnits}
Status: %{opened_dwellPDQ}
Close Dwell Time:
Value: %{closed_dwellValue}%{closed_dwellUnits}
Status: %{closed_dwellPDQ}
Cycle Count:
Value: %{cycle_countValue}
Status: %{cycle_countPDQ}
Valve State:
Value: %{valve_state_timeValue}
Status: %{valve_state_timePDQ}
Highest Device Temperature:
Value: %{highest_device_temperatureValue}%{highest_device_temperatureUnits}
Status: %{highest_device_temperaturePDQ}
Lowest Device Temperature:
Value: %{lowest_device_temperatureValue}%{lowest_device_temperatureUnits}
Status: %{lowest_device_temperaturePDQ}
Transition Dwell Time:
Value: %{transition_dwell_timeValue}%{transition_dwell_timeUnits}
Status: %{transition_dwell_timePDQ} |
1179 |
Connect reference meter. |
1180 |
Press 'Next' to set the 'Analog Output' to 4 mA. |
1181 |
Enter reference meter value. |
1182 |
Does the reference meter now match the 'Analog Output' of 4 mA? |
1183 |
Press 'Next' to set the 'Analog Output' to 20 mA. |
1184 |
Does the reference meter now match the 'Analog Output' of 20 mA? |
1185 |
The configuration could not be stored in the field device. |
1186 |
Priority: Failure - Fix Now
Description:
A device peripheral bus communication fault has occurred.
Recommended Actions:
1. Reset the device.
2. Contact factory if the alert persists. |
1187 |
Priority: Failure - Fix Now
Description:
The low frequency clock source failed to start.
Recommended Actions:
1. Reset the device.
2. Contact factory if the alert persists. |
1188 |
Priority: Failure - Fix Now
Description:
Set when an electrical component on the device failed.Recommended Actions:
1. Ensure loop power is properly supplied.
2. Reset the device (Service Tools - Maintenance - Reset/Restore).
3. If the process allows, cycle the HART power.
4. If the process allows, cycle the pilot power.
5. Replace main module if there is continued loss of any function. |
1189 |
Priority: Failure - Fix Now
Description:
The loop transistor drive voltage is lower or higher than expected.
Recommended Actions:
1. Reset the device.
2. Ensure loop power is properly supplied. |
1190 |
Priority: Failure - Fix Now
Description:
The device detected an issue with the position sensor.
Recommended Action:
1. Check the wiring connections for the positions sensor/potentiometer. |
1191 |
Priority: Failure - Fix Now
Description:
The device detected an issue with the limit switch.
Recommended Action:
1. Check the wiring connections for each limit switch. |
1192 |
Priority: Failure - Fix Now
Description:
FRAM Uncorrectable bit Error
Recommended Actions:
1. Reset the device.
2. Contact the factory if the problem persists. |
1193 |
Priority: Failure - Fix Now
Description:
RAM/Code overwrite Error. Microprocessor Stack Overflow.
Recommended Actions:
1. Reset the device.
2. Contact the factory if the problem persists. |
1194 |
Priority: Failure - Fix Now
Description:
Internal electronics failure.
Recommended Action:
1. Contact the factory. |
1195 |
Priority: Maintenance Required
Description:
The pressure value at the start of the PST test or the pressure at the return point was out of range.
Recommended Actions:
1. Verify the supply pressure.
2. Verify the actuator for proper operation. |
1196 |
Priority: Failure - Fix Now
Description:
Solenoid communication has failed.
Recommended Action:
1. Power cycle the unit. |
1197 |
Priority: Failure - Fix Now
Description:
Solenoid operation has failed.
Recommended Action:
1. Check solenoid power supply and mechanical operation. |
1198 |
Priority: Out of Specification - Fix Soon
Description:
The device is in multi-drop mode or the loop current is set to a fixed level and is not responding to process inputs.
Recommended Action:
1. If analog loop current signaling is desired disable multi-drop mode. |
1199 |
Priority: Function Check
Description:
Device variables are being simulated.
Recommended Action:
1. Disable Device Variable Simulation mode. |
1200 |
Priority: Function Check
Description:
Status alerts are being simulated.
Recommended Action:
1. Disable Status Simulation mode. |
1201 |
Priority: Function Check
Description:
Discrete variables are being simulated.
Recommended Action:
1. Disable Discrete Variable Simulation mode. |
1202 |
Priority: Function Check
Description:
Event notification buffers have overflowed.
Recommended Actions:
1. The device buffers 3 unacknowledged events.
2. Ensure the host acknowledges the events in a timely manner. |
1203 |
Priority: Out of Specification - Fix Soon
Description:
Valve position may not reflect actual value during calibration.
Recommended Action:
1. Complete the calibration method. |
1204 |
Priority: Out of Specification - Fix Soon
Description:
Valve stroke is too small or bad calibration.
Recommended Actions:
1. Stroke must be greater than 20 Degrees.
2. Recalibrate the valve span. |
1205 |
Priority: Out of Specification - Fix Soon
Description:
DAC trim is required to ensure accurate loop current output.
Recommended Action:
1. Execute the DAC trim method for trimming the loop current to the proper value against a calibrated current meter. |
1206 |
Priority: Out of Specification - Fix Soon
Description:
Calibrate the valve travel into the device.
Recommended Action:
1. Calibrate the valve stroke into the device by running the calibration method. |
1207 |
Priority: Out of Specification - Fix Soon
Description:
PST calibration is required before a PST can be executed.
Recommended Action:
1. Run the Partial Stroke Calibration method. |
1208 |
Priority: Maintenance Required
Description:
Cycle Count Limit has been exceeded.
Recommended Actions:
1. Valve maintenance is recommended.
2. Readjust or reset the 'Cycle Count Limit' parameter. |
1209 |
Priority: Maintenance Required
Description:
Set when the stroke time is outside the range set by the upper and lower limit ranges.
Recommended Actions:
1. Valve maintenance is recommended.
2. Adjust the limits according to the valves stroke time. |
1210 |
Priority: Maintenance Required
Description:
Set when the stroke time is outside the range set by the upper and lower limit ranges.
Recommended Action:
1. Stroke/Partially stroke the valve to reset the timer, clear the counter manually,increase the limit. |
1211 |
Priority: Maintenance Required
Description:
Set when the transition dwell time exceeds the upper limit parameter.
Recommended Actions:
1. Valve maintenance is recommended.
2. Adjust the limits according to the transition dwell time. |
1212 |
Priority: Maintenance Required
Description:
Set when the voltage at Solenoid 1 has exceeded the allowable tolerance.
Recommended Action:
1. Check the voltage across the terminals of Solenoid 1. |
1213 |
Priority: Maintenance Required
Description:
Set when the current at Solenoid 1 has exceeded the allowable tolerance.
Recommended Action:
1. Check the current through the coil of Solenoid 1. |
1214 |
Priority: Maintenance Required
Description:
Set when the voltage at Solenoid 2 has exceeded the allowable tolerance.
Recommended Action:
1. Check the voltage across the terminals of Solenoid 2. |
1215 |
Priority: Maintenance Required
Description:
Set when the current at Solenoid 2 has exceeded the allowable tolerance.
Recommended Action:
1. Check the current through the coil of Solenoid 2. |
1216 |
Priority: Maintenance Required
Description:
Partial Stroke Test has failed.
Recommended Actions:
1. Valve maintenance may be required.
2. Verify operation. |
1217 |
Priority: Maintenance Required
Description:
The time between solenoid activation and valve movement has exceeded the allowable tolerance on open.
Recommended Actions:
1. Valve maintenance may be required.
2. Verify operation. |
1218 |
Priority: Maintenance Required
Description:
The time between solenoid activation and valve movement has exceeded the allowable tolerance on close.
Recommended Actions:
1. Valve maintenance may be required.
2. Verify operation. |
1219 |
Priority: Maintenance Required
Description:
SOV failed to change state.
Recommended Action:
1. Check the operation of the SOV ( Solenoid Operated Valve). |
1220 |
Priority: Maintenance Required
Description:
Device has detected an Emergency Shutdown Event.
Recommended Actions:
1. Verify event with Safety Instrumented System (SIS).
2. Reset alert via AMS. |
1221 |
Priority: Maintenance Required
Description:
Pressure sensor has detected pressure value above upper pressure limit parameter.
Recommended Action:
1. Verify supply pressure is not above Upper Pressure Limit parameter. |
1222 |
Priority: Maintenance Required
Description:
Pressure sensor has detected pressure value below lower pressure limit parameter.
Recommended Action:
1. Verify supply pressure is not below Lower Pressure Limit parameter. |
1223 |
Priority: Failure - Fix Now
Description:
The device detected an issue with the pressure sensor.Recommended Actions:
1. Check the wiring connections to the pressure sensor.
2. Verify the sensor operates correctly. |
1224 |
Priority: Out of Specification - Fix Soon
Description:
Regulated power supply voltage is out of range.
Recommended Action:
1. Verify the bus voltage is in range. |
1225 |
Priority: Maintenance Required
Description:
Internal Temperature outside -40 to 80 degC.
Recommended Action:
1. Ensure the environmental conditions are appropriate for the device. |
1226 |
Priority: Out of Specification - Fix Soon
Description:
The device temperature sensor has failed.
Recommended Actions:
1. Reset the device.
2. Contact factory if the alert persists. |
1227 |
Warning - This will modify the calibrated Partial Stroke Time. |
1228 |
Enter the 'Partial Stroke Position'. |
1229 |
Select the 'PST Timing Tolerance': |
1230 |
Enter the 'Partial Stroke Timeout'. |
1231 |
Select the 'Pressure Alert Limit Units': |
1232 |
Enter the 'PST Pressure Upper Alert Limit'. |
1233 |
Enter the 'PST Pressure Lower Alert Limit'. |
1234 |
Warning - Please ensure the valve is at the 100% position. |
1235 |
Warning - Valve is about to calibrate partial stroke time.
Please ensure it is safe to do so before proceeding. |
1236 |
Partial Stroke Calibration in progress, please wait. |
1237 |
Failed- Timeout or Aborted. Do you wish to try again? |
1238 |
Failed - Valve did not move during partial stroke test. Do you wish to try again? |
1239 |
Failed - Valve traveled past calibrated partial stroke position. Do you wish to try again? |
1240 |
Failed - Due to timeout and no valve movement. Do you wish to try again? |
1241 |
Failed - Valve traveled past calibrated partial stroke position and outside allowed partial stroke time. Do you wish to try again? |
1242 |
Failed - Due to PST Pressure Out of Limits. Do you wish to try again? |
1243 |
Partial Stroke Calibration is completed successfully. |
1244 |
'PST Mode' is disabled, please enable it before proceeding. |
1245 |
Warning - This initiate the Partial Stroke Test. |
1246 |
Warning - This initiates the Solenoid Operated Valve Diagnostics Test. |
1247 |
Warning - Solenoid Operated Valve test is about to begin.
Please ensure it is safe to do so before proceeding. |
1248 |
Solenoid Operated Valve Test in progress, please wait. |
1249 |
SOV Test has failed to move or reach the threshold. Do you wish to try again? |
1250 |
SOV Test did not complete before timeout setting. Do you wish to try again? |
1251 |
SOV Test voltage or current out of tolerance. Do you wish to try again? |
1252 |
SOV Test has failed because the pressure is out of tolerance limits. Do you wish to try again? |
1253 |
SOV configuration error. Do you wish to try again? |
1254 |
SOV Test has failed due to timeout and no valve movement. Do you wish to try again? |
1255 |
SOV Test has failed as SOV test requirements were not met. Do you wish to try again? |
1256 |
SOV Test aborted. Do you wish to try again? |
1257 |
Solenoid Operated Valve Test is completed successfully. |
1258 |
'SOV Testing Configuration' is disabled. If SOV testing is required, please enable 'SOV Testing Configuration' before proceeding. If SOV is not required, continue to Partial Stroke Test. |
1259 |
Warning - Valve is about to partially stroke.
Please ensure it is safe to do so before proceeding. |
1260 |
Partial Stroke Test in progress, please wait. |
1261 |
Failed - Timeout. Do you wish to try again? |
1262 |
Failed - Valve partial stroke time outside allowed tolerance. Do you wish to try again? |
1263 |
Failed - Break away time outside allowed tolerance. Do you wish to try again? |
1264 |
Solenoid Electrical Characteristics outside allowed tolerance. Do you wish to try again? |
1265 |
Failed - Due to PST Pressure out of limits. Do you wish to try again? |
1266 |
Failed - Due to partial stroke time out of tolerance. Do you wish to try again? |
1267 |
Solenoid Electrical Characteristics outside allowed tolerance and PST pressure out of limits. Do you wish to try again? |
1268 |
Failed - Valve traveled past calibrated partial stroke position and PST pressure out of limits. Do you wish to try again? |
1269 |
Failed - Due to timeout, no valve movement and PST pressure out of limits. Do you wish to try again? |
1270 |
Failed - Valve did not move during partial stroke test and PST pressure out of limits. Do you wish to try again? |
1271 |
Failed - Timeout and PST pressure out of limits. Do you wish to try again? |
1272 |
Failed - Valve partial stroke time outside allowed tolerance and PST pressure out of limits. Do you wish to try again? |
1273 |
Partial Stroke Test has passed. |
1274 |
|
1275 |
SOV sensor failed to change state |
1276 |
SOV Test has timed out |
1277 |
SOV Test was aborted before completion |
1278 |
SOV voltage or current is out of tolerance |
1279 |
SOV pressure is out of tolerance |
1280 |
SOV configuration error |
1281 |
SOV sensor failed to return to initial state |
1282 |
SOV Test has failed due to: %{optionString}
Do you wish to try again? |
1283 |
'SOV Testing Configuration' is disabled, please enable it before proceeding. |
1284 |
Warning - This starts the method for recording Valve Signatures. |
1285 |
Select the 'Valve Signature Type': |
1286 |
Partial Stroke Test Signature;Full Stroke Test Signature |
1287 |
Warning - Device is about to be HART locked for test. |
1288 |
Warning - Device is entering automatic device control mode. The valve will change position without warning.Valve Signature test is about to begin.
Please ensure it is safe to do so before proceeding. |
1289 |
Valve Signature Test in progress, please wait. |
1290 |
Valve Signature Test has failed - Timeout. Do you wish to try again? |
1291 |
Valve Signature Test has failed - Valve did not move during test. Do you wish to try again? |
1292 |
Failed - Valve traveled past the calibrated partial stroke position. Do you wish to try again? |
1293 |
Removing HART lock, Valve Signature Test has passed. |
1294 |
Enter the 'Valve Signature Record Number'. |
1295 |
Baseline;Record 1;Record 2;Record 3 |
1296 |
Enter the 'Valve Signature Test Date'. |
1297 |
Valve Signature Test is completed successfully. |
1298 |
'Valve Signature Mode' is disabled, please enable it before proceeding. |
1299 |
Warning - This method will reset the Emergency Shutdown Alarm.
Do you wish to continue with reset? |
1300 |
Cancel, do not reset the alarm.;Continue, reset the alarm. |
1301 |
ESD Alarm Reset is in progress, please wait. |
1302 |
ESD Alarm Reset is completed successfully. |
1303 |
Method Finish |
1304 |
Valve Signature Data Graph settings are successfully updated. |
1305 |
Warning - This will affect sensor calibration. Loop should be removed from automatic control before proceeding. |
1306 |
Enter the 'Lower Trim Point'. |
1307 |
Pressure Sensor Lower Trim is in progress, please wait. |
1308 |
'Lower Trim Point' value is adjusted to %{device_pressureLowerTrimPoint} %{device_pressureUnits}. |
1309 |
Pressure Sensor Lower Trim is completed successfully. |
1310 |
Enter the 'Upper Trim Point'. |
1311 |
Pressure Sensor Upper Trim is in progress, please wait. |
1312 |
'Upper Trim Point' value is adjusted to %{device_pressureUpperTrimPoint} %{device_pressureUnits}. |
1313 |
Pressure Sensor Upper Trim is completed successfully. |
1314 |
Pressure Sensor Zero Trim is in progress, please wait. |
1315 |
'Zero Trim' value is adjusted to %{device_pressureValue} %{device_pressureUnits}. |
1316 |
Pressure Sensor Zero Trim is completed successfully. |
1317 |
Warning - This will affect sensor calibration. Loop should be removed from automatic control before proceeding.
Do you wish to continue with reset? |
1318 |
Cancel, do not reset trim points.;Continue, reset the trim points. |
1319 |
Reset Sensor Trim is in progress, please wait. |
1320 |
Reset Sensor Trim is completed successfully. |
1321 |
Build No: 1.0
Build Date: 05-Nov-2020
DD Revision: 01
TopWorx Inc., Emerson Automation Solutions |
1322 |
Select an option to simulate 'Auxiliary/Pressure Switch 1': |
1323 |
'Auxiliary/Pressure Switch 1' is fixed at %{0}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1324 |
Enter a fixed value (simulated value) for 'PST Cycle Count'. |
1325 |
'PST Cycle Count' is fixed at %{0} %{1}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |
1326 |
Enter a fixed value (simulated value) for 'Break Away Time'. |
1327 |
'Break Away Time' is fixed at %{0} %{1}.
Pressing 'Next' or 'Cancel' will end the simulation and return device to normal operation. |