0 |
FST-3000 |
1 |
.1f |
2 |
.2f |
3 |
.3f |
4 |
.4f |
5 |
.5f |
6 |
8.3f |
7 |
7d |
8 |
Designed Density |
9 |
|
10 |
Liquid Density |
11 |
AO Direction |
12 |
Analog Output Direction |
13 |
4mA at 0%, 20mA at 100% |
14 |
20mA at 0%, 4mA at 100% |
15 |
Indication Selection |
16 |
level (mm) |
17 |
level (cm) |
18 |
level 0to100 (%) |
19 |
level -50to50 (%) |
20 |
density |
21 |
0% Ind. Scalling |
22 |
0% Indication Scaling |
23 |
100% Ind. Scalling |
24 |
100% Indication Scaling |
25 |
Displacer Weight |
26 |
grf |
27 |
.0f |
28 |
Displacer Diameter |
29 |
Torque Tube Coef.(a) |
30 |
Torque Tube Coefficient (a) |
31 |
kg/Sq.mm |
32 |
Torque Tube Coef.(b) |
33 |
Torque Tube Coefficient (b) |
34 |
kg/Sq.mmDegC |
35 |
Exist of Temp.Sensor |
36 |
Existence of Temperature Sensor |
37 |
Not provided |
38 |
Provided |
39 |
Linearity Adjst.0% |
40 |
Linearity Adjustment (0%) |
41 |
Linearity Adjst.25% |
42 |
Linearity Adjustment (25%) |
43 |
Linearity Adjst.50% |
44 |
Linearity Adjustment (50%) |
45 |
Linearity Adjst.75% |
46 |
Linearity Adjustment (75%) |
47 |
Linearity Adjst.100% |
48 |
Linearity Adjustment (100%) |
49 |
No. of linearizing |
50 |
Number of linearizing |
51 |
3 Points |
52 |
5 Points |
53 |
Angle of T.T. at 0% |
54 |
Distortion angle of torque tube at 0% |
55 |
Angle of T.T. at 100% |
56 |
Distortion angle of torque tube at 100% |
57 |
Offset Val. after Calc. |
58 |
Offset Value after Calculation |
59 |
Temp. when Adjust. |
60 |
Temperature when adjusting |
61 |
H.E. Offset Value |
62 |
Hall Element Offset Value |
63 |
C.H.E. Offset Val. |
64 |
Compensation Hall Element Offset Value |
65 |
TSCC (-200degC) |
66 |
Temp. Sensor Compensation Calibration (-200degC) |
67 |
TSCC (400degC) |
68 |
Temp. Sensor Compensation Calibration (400degC) |
69 |
A.C. Output Monitor |
70 |
Angle Convertor Output Monitoring |
71 |
C.H.E. Output Monitor |
72 |
Compensation Hall Element Output Monitoring |
73 |
Error Status |
74 |
SELF DIAGNOSIS MESSAGE, ERROR CODE DESCRIPTION |
75 |
No Errors |
76 |
E1 Power supply not in order |
77 |
E2 Temp.sensor not in order |
78 |
E3 Angle transducer not in order |
79 |
E4 AD convertor not in order (Problem in AMP board) |
80 |
E5 CPU not in order (Problem in CPU/Indication board) |
81 |
E6 EEPROM not in order (Problem in AMP board) |
82 |
Master reset |
83 |
Density |
84 |
FST-3000 info |
85 |
FMU860 |
86 |
DT |
87 |
DVC |
88 |
FCX |
89 |
AS800 |
90 |
340T |
91 |
340C |
92 |
344 |
93 |
Siemens Micro K |
94 |
SITRANS L |
95 |
SIPAN PH |
96 |
SITRANS P |
97 |
75SMT |
98 |
UNIDELTA |
99 |
8320 |
100 |
SX5100 |
101 |
TSV175 |
102 |
DMU |
103 |
3780 |
104 |
BM70 |
105 |
8u |
106 |
low |
107 |
high |
108 |
tmp_av |
109 |
REksetzen ist erfolgt |