0 |
TRZ |
1 |
Moore Industries |
2 |
Volt |
3 |
Volt. |
4 |
Res. |
5 |
Temp. |
6 |
.2f |
7 |
.1f |
8 |
Digital Unit |
9 |
USL |
10 |
.0f |
11 |
LSL |
12 |
MinSpan |
13 |
Sec. |
14 |
2.f |
15 |
I Out |
16 |
.3f |
17 |
5f |
18 |
% range |
19 |
Range Unit |
20 |
URV |
21 |
7.f |
22 |
LRV |
23 |
|
24 |
7d |
25 |
Sensor |
26 |
input sensor type mV,Ohm,RTD,T/C |
27 |
mV Lo |
28 |
mV Hi |
29 |
mV Lo lin |
30 |
mV Hi lin |
31 |
Ohm Lo |
32 |
Ohm Hi |
33 |
Pot Lo |
34 |
Pot Hi |
35 |
Ohm Lo lin |
36 |
Ohm Hi lin |
37 |
Pot Lo lin |
38 |
Pot Hi lin |
39 |
RTD PT |
40 |
RTD NI |
41 |
RTD CU |
42 |
T/C B |
43 |
T/C E |
44 |
T/C J |
45 |
T/C K |
46 |
T/C L |
47 |
T/C N |
48 |
T/C R |
49 |
T/C S |
50 |
T/C T |
51 |
T/C U |
52 |
T/C W3 |
53 |
T/C W5 |
54 |
Local variable. Do not change |
55 |
CJCWires |
56 |
Wire No. |
57 |
Numbers of wires for Ohm/RTD measurement and number of CJC wires for thermocouple measurement (CJC wires = 0 is internal compensation) |
58 |
RTD value |
59 |
RTD value 25 .. 1000 Ohm |
60 |
4.f |
61 |
Ohm |
62 |
Cable R. |
63 |
Two wire cable compensation 0.0 .. 60.0 Ohm |
64 |
2.2f |
65 |
5.f |
66 |
Under Lim |
67 |
Input under LSL indication 3.60 .. 4.00 mA |
68 |
mA |
69 |
Over Lim |
70 |
Input over USL indication 20.00 .. 23.00 mA |
71 |
Sens.Err |
72 |
Sensor breakdown indication, upscale 20.00 .. 23.00 mA , downscale 3.60 .. 4.00 |
73 |
Min V |
74 |
Min R |
75 |
Min T |
76 |
Datalogger function, stores min value measured. Value can be cleared (Reset min/max) |
77 |
Max V |
78 |
Max R |
79 |
Max T |
80 |
Datalogger function, stores max value measured. Value can be cleared (Reset min/max) |
81 |
The offset added to the value measured |
82 |
Offs. |
83 |
Sensor type |
84 |
Select sensor type mv,Ohm,T/C,RTD |
85 |
Reset min/max |
86 |
Resets min/max value measured (datalogger function) |
87 |
Sensor trim |
88 |
Sensor trim makes an offset to the measured input to correct any sensor error. |
89 |
Factory trim |
90 |
Factory trim resets the sensor trim offset to factory setting |
91 |
Main menu |
92 |
Input setup |
93 |
Output setup |
94 |
DataLogger |
95 |
Sensor Trim |
96 |
Quick Access Key |
97 |
FMU860 |
98 |
DT |
99 |
DVC |
100 |
FCX |
101 |
AS800 |
102 |
340T |
103 |
340C |
104 |
344 |
105 |
Siemens Micro K |
106 |
SITRANS L |
107 |
SIPAN PH |
108 |
SITRANS P |
109 |
75SMT |
110 |
UNIDELTA |
111 |
8320 |
112 |
SX5100 |
113 |
TSV175 |
114 |
DMU |
115 |
3780 |
116 |
BM70 |
117 |
8u |
118 |
Select sensortype |
119 |
RTD;T/C;mV;Ohm;Pot |
120 |
Select RTD type |
121 |
PT;NI;CU |
122 |
Select RTD value |
123 |
Select T/C type |
124 |
B;E;J;K;L;N;R;S;T;U;W3;W5 |
125 |
Select mV Low/Hi |
126 |
-10 .. 70mV;-0.1 .. 1.1V |
127 |
Select Ohm Low/Hi |
128 |
0..390 Ohm;0..2200 Ohm |
129 |
Select Pot Low/Hi |
130 |
0 .. 390 Ohm; 0 .. 2200 Ohm |
131 |
--PLEASE WAIT-- |
132 |
Aborting method due to last error |
133 |
Min/max value has been cleared ! |
134 |
Sensor trim offset has been reset to factory setting ! |
135 |
Read reference value and syncronize by pressing Ok ! PV : %0 |
136 |
Enter New value |