0 |
.3f |
1 |
8.3f |
2 |
7d |
3 |
Damping Value |
4 |
Level - Distance from bottom of tank to top of product. |
5 |
Level |
6 |
.0f |
7 |
.2f |
8 |
.1f |
9 |
Level transmitter units |
10 |
Level Unit |
11 |
Level USL |
12 |
Level LSL |
13 |
Level Min Span |
14 |
Level URV |
15 |
8.0f |
16 |
9.3f |
17 |
9.2f |
18 |
8.2f |
19 |
8.1f |
20 |
10.0f |
21 |
Level LRV |
22 |
Distance - Linear measurement from gauge to top of product in tank; sometimes referred to as range or ullage. |
23 |
Distance |
24 |
Distance USL |
25 |
Distance LSL |
26 |
Distance Min Span |
27 |
Distance URV |
28 |
Distance LRV |
29 |
Volume |
30 |
Volume transmitter units |
31 |
Volume Unit |
32 |
Volume USL |
33 |
Volume LSL |
34 |
Volume Min Span |
35 |
Volume URV |
36 |
Volume LRV |
37 |
Volume - Amount of product in tank. |
38 |
Internal temperature of the electronics in the gauge. |
39 |
Internal Temp |
40 |
Temperature transmitter units |
41 |
Temperature Unit |
42 |
InternalTemp USL |
43 |
InternalTemp LSL |
44 |
InternalTemp Min Span |
45 |
InternalTemp URV |
46 |
InternalTemp LRV |
47 |
Interface Distance - Linear measurement from gauge to interface in tank. |
48 |
Interface Distance |
49 |
InterfaceDis USL |
50 |
InterfaceDis LSL |
51 |
InterfaceDis Min Span |
52 |
InterfaceDis URV |
53 |
InterfaceDis LRV |
54 |
Interface - Distance from bottom of tank to interface |
55 |
Interface Level |
56 |
Interface USL |
57 |
Interface LSL |
58 |
Interface Min Span |
59 |
Interface URV |
60 |
Interface LRV |
61 |
Amplitude of fiducial pulse |
62 |
Amplitude Peak 1 |
63 |
Amplitude Peak USL |
64 |
Amplitude Peak LSL |
65 |
Amplitude Peak Min Span |
66 |
Amp Peak 1 URV |
67 |
6.1f |
68 |
Amp Peak 1 LRV |
69 |
Amplitude of level pulse |
70 |
Amplitude Peak 2 |
71 |
Amp Peak 2 URV |
72 |
Amp Peak 2 LRV |
73 |
Amplitude of interface pulse |
74 |
Amplitude Peak 3 |
75 |
Amp Peak 3 URV |
76 |
Amp Peak 3 LRV |
77 |
Interface Thickness - Linear measurement from level to interface. |
78 |
Upper Prod Thickn |
79 |
IntrfacThick USL |
80 |
IntrfacThick LSL |
81 |
IntrfacThick Min Span |
82 |
IntrfacThick URV |
83 |
IntrfacThick LRV |
84 |
InternalTemp |
85 |
InterfaceDis |
86 |
Interface |
87 |
Amp Peak 1 |
88 |
Amp Peak 2 |
89 |
Amp Peak 3 |
90 |
IntrfacThick |
91 |
Model Code |
92 |
3300 |
93 |
AO Alarm Type |
94 |
QV is |
95 |
Invalid configuration |
96 |
The configuration was determined to be invalid at startup |
97 |
RAM failure |
98 |
An error occurred during pattern checking of RAM |
99 |
ROM checksum failure |
100 |
ROM checksum was not valid |
101 |
Fiducial pulse not found |
102 |
Level pulse not found |
103 |
Interface pulse not found |
104 |
Waveform acquisition fail |
105 |
EEPROM factory area failure |
106 |
A checksum error has been detected in the factory area of the EEPROM |
107 |
EEPROM user area failure |
108 |
A checksum error has been detected in the user area of the EEPROM |
109 |
Internal temperature out of limits |
110 |
Software error |
111 |
An error has occurred in the 3300 software; analog output will indicate an alarm condition; this condition will persist until the device is reset. |
112 |
Volume computation error |
113 |
Immersed probe |
114 |
Probe failure |
115 |
Reserved error flag 2-7 |
116 |
Reserved error flag 2-8 |
117 |
Dynamic var |
118 |
Perform master reset |
119 |
Master reset |
120 |
Factory Settings |
121 |
Resetting the EEPROM changes all of the special and user parameters to default values. |
122 |
PV LRV |
123 |
PV URV |
124 |
Variable Mapping |
125 |
Measure Units |
126 |
Geometry/Probe |
127 |
Misc. Settings |
128 |
AO Values |
129 |
Construction Details |
130 |
Display |
131 |
Volume Geometry |
132 |
Strapping Table |
133 |
HART |
134 |
Advanced Service |
135 |
Thresholds |
136 |
|
137 |
Signal info |
138 |
Height at which the transmitter flange is mounted |
139 |
Ref Gauge Height |
140 |
Angle at which transmitter is mounted, with 0 being verticle |
141 |
Probe Angle |
142 |
Length of antenna or probe |
143 |
Probe Length |
144 |
Empty Tank Detect |
145 |
EmtyTnk |
146 |
transmitter height too large |
147 |
transmitter height too small |
148 |
transmitter angle too large |
149 |
transmitter angle too small |
150 |
empty tank detect too large |
151 |
empty tank detect too small |
152 |
Style of tank |
153 |
Tank Type |
154 |
Strap Table |
155 |
A tank of arbitrary shape whose volume is calculated by interpolating values in a table, known as a strapping table. |
156 |
Ver Cylindr |
157 |
Vertical Cylinder |
158 |
Hor Cylindr |
159 |
Horizontal Cylinder |
160 |
Vert Bullet |
161 |
Vertical Bullet, a vertical cylinder with rounded, semispherical ends |
162 |
Hor Bullet |
163 |
Horizontal Bullet, a horizontal cylinder with rounded, semispherical ends |
164 |
Sphere |
165 |
none |
166 |
Tank diameter |
167 |
Tank Diameter |
168 |
Height of tank |
169 |
Tank Height |
170 |
tank diameter too large |
171 |
tank diameter too small |
172 |
tank height/length too large |
173 |
tank height/length too small |
174 |
invalid tank type |
175 |
current index into strapping table |
176 |
strapping index |
177 |
3d |
178 |
Strapping point 0 level |
179 |
Lvl0 |
180 |
Strapping point 1 level |
181 |
Lvl1 |
182 |
Strapping point 2 level |
183 |
Lvl2 |
184 |
Strapping point 3 level |
185 |
Lvl3 |
186 |
Strapping point 4 level |
187 |
Lvl4 |
188 |
Strapping point 5 level |
189 |
Lvl5 |
190 |
Strapping point 6 level |
191 |
Lvl6 |
192 |
Strapping point 7 level |
193 |
Lvl7 |
194 |
Strapping point 8 level |
195 |
Lvl8 |
196 |
Strapping point 9 level |
197 |
Lvl9 |
198 |
Strapping point 0 volume |
199 |
Vol0 |
200 |
Strapping point 1 volume |
201 |
Vol1 |
202 |
Strapping point 2 volume |
203 |
Vol2 |
204 |
Strapping point 3 volume |
205 |
Vol3 |
206 |
Strapping point 4 volume |
207 |
Vol4 |
208 |
Strapping point 5 volume |
209 |
Vol5 |
210 |
Strapping point 6 volume |
211 |
Vol6 |
212 |
Strapping point 7 volume |
213 |
Vol7 |
214 |
Strapping point 8 volume |
215 |
Vol8 |
216 |
Strapping point 9 volume |
217 |
Vol9 |
218 |
Number of entries in the strapping table |
219 |
Entries used |
220 |
Maximum number of entries in the strapping table |
221 |
Max entries |
222 |
strapping level too high |
223 |
strapping level too low |
224 |
strapping volume too high |
225 |
strapping volume too low |
226 |
strapping point out of sequence |
227 |
invalid index number |
228 |
Type of pipe threads; this does not apply to the 3300 |
229 |
Flange Type |
230 |
DIN |
231 |
ANSI |
232 |
NPT |
233 |
Material of which flange is constructed |
234 |
Flange Material |
235 |
Shows whether or not a local display is installed on the 3300 |
236 |
Meter |
237 |
Installed |
238 |
A local display is installed on the 3300. |
239 |
None |
240 |
No local display is installed on the 3300. |
241 |
Material of which antenna is constructed |
242 |
Probe Material |
243 |
Material of which barrier is constructed |
244 |
Barrier |
245 |
Ceramic |
246 |
Unknown |
247 |
Special |
248 |
Threshold offset for fiducial pulse |
249 |
Threshold Offset 1 |
250 |
Threshold offset for level pulse |
251 |
Threshold Offset 2 |
252 |
Threshold offset for interface pulse |
253 |
Threshold Offset 3 |
254 |
Threshold offset for filled tank detection |
255 |
Threshold Offset 4 |
256 |
Number of points to be fitted |
257 |
NumPoints1 |
258 |
Step size |
259 |
StepSize1 |
260 |
NumPoints2 |
261 |
StepSize2 |
262 |
Gain control |
263 |
Upper alarm current |
264 |
High Alarm |
265 |
Lower alarm current |
266 |
Low Alarm |
267 |
Upper alarm saturation current |
268 |
High Saturation |
269 |
Low Saturation |
270 |
Upper null zone -- Level above which the 3300 ignores radar reflections. |
271 |
Upper Null Zone |
272 |
Lower null zone -- Level below which the 3300 ignores radar reflections. |
273 |
Lower Null Zone |
274 |
Number volt bits |
275 |
Volt per count |
276 |
Samples |
277 |
Range per count |
278 |
Dielectric of Vapor |
279 |
Vapor Dielectric |
280 |
This is the product dielectric for level measurements and upper product dielectric for interface measurements. |
281 |
Product Dielectric |
282 |
Measurement Mode |
283 |
Interf w. imrsd prb |
284 |
Level and Interface |
285 |
Units in which upper product thickness is measured. |
286 |
Max Up Prod Tkn Units |
287 |
Max upper product thickness |
288 |
Max Up Prod Tkn |
289 |
Units in which Distance Offset is measured. |
290 |
Offset Units |
291 |
Offset Value added to distance |
292 |
Calibr Offset |
293 |
Type of Probe |
294 |
Probe Type |
295 |
Rigid twin |
296 |
Flexible twin |
297 |
Coaxial |
298 |
Rigid single |
299 |
Flexible single |
300 |
Coaxial HTHP |
301 |
Coaxial HP |
302 |
Rigid single HTHP |
303 |
Flexible single HTHP |
304 |
Rigid single PTFE |
305 |
Flexible single PTFE |
306 |
Probe A1 |
307 |
Probe A2 |
308 |
Probe A3 |
309 |
Probe A4 |
310 |
Probe A5 |
311 |
User |
312 |
Shows product level (or interface level) as 0 when level is below the probe end. |
313 |
Show lvl=0 if lvl is below probe end |
314 |
Off |
315 |
On |
316 |
Invalid page |
317 |
Invalid address |
318 |
Command not implemented |
319 |
2d |
320 |
Threshold fiducial pulse |
321 |
T-hold1 |
322 |
5.0f |
323 |
T-hold2 |
324 |
T-hold3 |
325 |
T-hold4 |
326 |
Amplitude fiducial pulse |
327 |
Amp1 |
328 |
Amp2 |
329 |
Amp3 |
330 |
Warning! Resetting the EEPROM will change all of the special and user parameters to default values. |
331 |
EEPROM Reset |
332 |
Reset All User |
333 |
Reset User Area |
334 |
Reset Special Area |
335 |
3300 display language |
336 |
Display language |
337 |
English |
338 |
Parameter on 3300 display |
339 |
Display variables |
340 |
Internal temperature |
341 |
Interface distance |
342 |
Interface level |
343 |
Upper prod thickness |
344 |
Amplitude peak 1 |
345 |
Amplitude peak 2 |
346 |
Amplitude peak 3 |
347 |
Percent of range |
348 |
Analog out current |
349 |
FMU860 |
350 |
DT |
351 |
DVC |
352 |
FCX |
353 |
AS800 |
354 |
340T |
355 |
340C |
356 |
344 |
357 |
Siemens Micro K |
358 |
SITRANS L |
359 |
SIPAN PH |
360 |
SITRANS P |
361 |
75SMT |
362 |
UNIDELTA |
363 |
8320 |
364 |
SX5100 |
365 |
TSV175 |
366 |
DMU |
367 |
3780 |
368 |
BM70 |
369 |
8u |
370 |
low |
371 |
high |
372 |
tmp_av |
373 |
Please wait while the 3300 is reset; this takes about 10 seconds. |
374 |
Select EEPROM area to reset: |
375 |
Reset All User;Reset User Area;Reset Special Area |
376 |
Please wait while loading factory configuration; this takes about 10 seconds. |