0 |
9701/03 Mass flo |
1 |
Date- Gregorian calendar date, entered as mm/dd/yy, that is stored in the Field Device. This date can be used by the user in any way. There is no specific recommended use. |
2 |
No |
3 |
4.1f |
4 |
RTD failure |
5 |
Temperature out of range |
6 |
Mass flow out of range |
7 |
Volume flow out of range |
8 |
Analog output saturated |
9 |
Data loss possible |
10 |
Analog output fixed |
11 |
Raw flow overflow |
12 |
Raw electronic zero overflow |
13 |
Auto zero failure |
14 |
Frequency output saturated |
15 |
Frequency output fixed |
16 |
Flo unit |
17 |
Flo |
18 |
.1f |
19 |
.2f |
20 |
.3f |
21 |
.4f |
22 |
.5f |
23 |
The flow rate below which the frequency/pulse output indicates zero flow. |
24 |
Flo cutoff |
25 |
mA |
26 |
Flo anlog valu |
27 |
4.2f |
28 |
% |
29 |
Flo % rnge |
30 |
Determines whether the Event is activated when it goes above (High) or below (Low) the setpoint. |
31 |
Alarm select |
32 |
Flo URV |
33 |
Flo LRV |
34 |
Sec |
35 |
7d |
36 |
Flo URL |
37 |
8.2f |
38 |
Flo LRL |
39 |
Flo min span |
40 |
Totl unit |
41 |
Totl |
42 |
QV |
43 |
A control that enables the user to determine whether the frequency/pulse output and totalizers will indicate forward, reverse, or bi-directional flow. |
44 |
The number of cycles, in Hertz, that equal a proportional flow rate represented by the frequency/pulse output. |
45 |
Hz |
46 |
The flow rate that equals a set frequency if the frequency output represents mass or volume flow; or the mass or volume total that equals a set number of pulses if the frequency output represents mass or volume total. |
47 |
6.2f |
48 |
A programmable high limit on density, which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. |
49 |
g/cc |
50 |
Slug high limit |
51 |
5.4f |
52 |
A programmable low limit on density, which enables the transmitter to indicate slug flow (extremes in fluid density caused by slugs of gas or accumulation of solids in a liquid flow stream) if fluid density goes outside programmed slug flow limits. |
53 |
Slug low limit |
54 |
A 10-character factor that describes the sensitivity of the sensor to mass flow. The first 6 characters are the flow rate, in grams/second, per microsecond of time shift between velocity signals from the sensor. The 2nd four characters are the flow temperature coefficient. |
55 |
FlowCal |
56 |
A value (in Hertz) that will be indicated on the frequency output for the purpose of a loop test. |
57 |
The frequency, in Hertz, presently being indicated on the frequency output. |
58 |
Pres freq |
59 |
6.1f |
60 |
Allows the user to Reset all totalizers. NOTE - Inventory totals are NOT reset. |
61 |
14 characters describing the sensitivity of the sensor to density. |
62 |
A value, in microseconds, representing the phase shift between velocity signals from the sensor when measuring zero flow. |
63 |
uSec |
64 |
Zero value |
65 |
5.3f |
66 |
Units for zero offset - always microseconds. |
67 |
Zero units |
68 |
1d |
69 |
Analog range vals |
70 |
Freq scaling |
71 |
View fld dev vars |
72 |
View output vars |
73 |
Test/Status |
74 |
Charize sensor |
75 |
Config outputs |
76 |
View SV |
77 |
View TV |
78 |
View QV |
79 |
Flow |
80 |
Density |
81 |
Analog output |
82 |
Frequency output |
83 |
Device info |
84 |
Fld dev vars |
85 |
Outputs |
86 |
Write variables |
87 |
Process Variables |
88 |
Device |
89 |
Diagnostic |
90 |
Perform Cal |
91 |
Please refer to manual for complete calibration instructions. |
92 |
Fix Analog Output |
93 |
Outputs a user-programmed frequency to the frequency output. |
94 |
Trim Analog Output |
95 |
Instructs transmitter to perform internal self test. |
96 |
Reset totalizer |
97 |
Resets internal totalizers. |
98 |
View status |
99 |
Reports any currently active device status information. |
100 |
Exits fixed mode and returns the frequency output to its active state. |
101 |
Aborts Auto Zero operation and continues to use previous zero offset value. |
102 |
Total |
103 |
Present Frequency |
104 |
FMU860 |
105 |
DT |
106 |
DVC |
107 |
FCX |
108 |
AS800 |
109 |
340T |
110 |
340C |
111 |
344 |
112 |
Siemens Micro K |
113 |
SITRANS L |
114 |
SIPAN PH |
115 |
SITRANS P |
116 |
75SMT |
117 |
UNIDELTA |
118 |
8320 |
119 |
SX5100 |
120 |
TSV175 |
121 |
DMU |
122 |
3780 |
123 |
BM70 |
124 |
8u |
125 |
WARN-Loop should be removed from automatic control |
126 |
Flow must be zero
Perform calibration? |
127 |
A problem was detected |
128 |
Abort;Fix and Retry |
129 |
Calibration in Progress
Zero: %0 |
130 |
Auto Zero Complete
Zero: %0 |
131 |
NOTE-Loop may be returned to automatic control |
132 |
Choose analog output level |
133 |
4 mA;20 mA;Other;End |
134 |
Output value: |
135 |
userEntry |
136 |
Aborting due to field device error |
137 |
Analog Output is fixed at %0 |
138 |
Choose frequency output level |
139 |
1 kHz;Other;End |
140 |
Output |
141 |
Frequency output is fixed at %0 Hz |
142 |
Connect reference meter |
143 |
About to set analog output to 4.0 mA |
144 |
Enter meter value |
145 |
Is fld dev 4.00 mA output equal to reference meter? |
146 |
Yes;No |
147 |
About to set analog output to 20.0 mA |
148 |
Is fld dev 20.00 mA output equal to reference meter? |
149 |
Selftest complete |
150 |
Transmitter status complete |
151 |
Transmitter status OK |
152 |
Returning fld dev to original output |
153 |
NOTE-Variables which use this as the units code will be in the previous units until this value is sent to the device |