0 |
Metran-150 |
1 |
Metran |
2 |
Transmitter rev |
3 |
Device Status |
4 |
Primary Variable Out of Limits |
5 |
Non Primary Variable Out of Limits |
6 |
mA Output Saturated |
7 |
mA Output Fixed |
8 |
Additional Status available |
9 |
Cold Start |
10 |
Configuration Changed |
11 |
Configuration Changed: Any user configurable data was changed.
|
12 |
Field Device Malfunction |
13 |
Transmitter S/N |
14 |
Polling address |
15 |
Dev ID |
16 |
Master reset |
17 |
Analog output trim |
18 |
#1 ADC data doesn't come to the processor |
19 |
#2 Answering interval from ADC exceed 100 ms |
20 |
#3 Answering interval from DAC exceed 100 ms |
21 |
#4 ADC data doesn't come on start |
22 |
#5 ROM checksum error |
23 |
#6 Processor ALU error |
24 |
#7 RAM checksum error |
25 |
#9 Incorrect DAC temperature value |
26 |
#10 Incorrect temperature factors calculation |
27 |
#11 Incorrect ADC temperature code |
28 |
#12 Pressure code is out of sensor limits |
29 |
#13 Incorrect reading of PIN code |
30 |
#14 Incorrect reading of LCD mode |
31 |
#15 Incorrect reading of LCD language |
32 |
#16 ADC temp code out of limits |
33 |
#17 Incorrect reading of units |
34 |
#21 Power supply less than 12 V |
35 |
#22 Button 1 is stuck |
36 |
#23 Button 2 is stuck |
37 |
#24 Button 3 is stuck |
38 |
#25 Incorrect reading of ID number |
39 |
#26 Incorrect reading of polling address or num of preambles |
40 |
#27 Incorrect reading of tag |
41 |
#28 Incorrect reading of message |
42 |
#29 Incorrect reading date or descriptor |
43 |
#30 Incorrect reading of AO alarm type, transfer function or distributor code |
44 |
#31 Incorrect reading of transmitter S/N |
45 |
#33 Incorrect reading of USL |
46 |
#34 Incorrect reading of LSL |
47 |
#35 Incorrect reading of ADC config. byte |
48 |
#36 Incorrect reading of tech information about sensor |
49 |
#37 Incorrect reading of tech information about ADC |
50 |
#38 Incorrect reading of technological information |
51 |
#40 Incorrect reading of ADC thermocorrection factors |
52 |
#41 Incorrect reading of DAC zero |
53 |
#42 Incorrect reading of DAC gain |
54 |
#43 Incorrect reading of DAC thermocorrection factors |
55 |
#44 Incorrect reading of ADC zero |
56 |
#45 Incorrect reading of ADC gain |
57 |
#46 Incorrect reading of units, damping or write protect status |
58 |
#47 Incorrect reading of control byte |
59 |
#48 Incorrect reading of sensor S/N |
60 |
#49 Incorrect reading of units |
61 |
#50 Incorrect reading of damping |
62 |
#51 Incorrect reading of write protect status |
63 |
#52 Incorrect reading of polling address |
64 |
#53 Incorrect reading of control byte |
65 |
#54 Incorrect reading of Num Req Preams |
66 |
#55 EEPROM DAC writing error |
67 |
#56 EEPROM ADC writing error |
68 |
#57 Incorrect reading of AO alarm type |
69 |
#58 Incorrect reading of transfer function |
70 |
#59 Incorrect reading of distributor code |
71 |
#62 Loop current saturated |
72 |
#63 Outside temperature limits |
73 |
#64 Incorrect reading of sensor information |
74 |
Percent of Range |
75 |
Analog Output |
76 |
AO alarm type |
77 |
Transfer function |
78 |
Upper Range Value |
79 |
Lower Range Value |
80 |
|
81 |
Lower Sensor Trim Point - The pressure at which the last low sensor trim was performed. |
82 |
Lower Trim Point |
83 |
Upper Sensor Trim Point - The pressure at which the last upper sensor trim was performed. |
84 |
Upper Trim Point |
85 |
Pressure |
86 |
.3f |
87 |
.6f |
88 |
.1f |
89 |
.4f |
90 |
.7f |
91 |
.2f |
92 |
Unit |
93 |
Kilograms Per Square Meter |
94 |
Upper Sensor Limit |
95 |
Lower Sensor Limit |
96 |
Damping |
97 |
8.3f |
98 |
Sensor S/N |
99 |
7d |
100 |
Password |
101 |
Password- In case of true input variables on HART will be editable |
102 |
4d |
103 |
Model |
104 |
Model - device model |
105 |
LCD |
106 |
Analog output |
107 |
Temperature |
108 |
URV |
109 |
LRV |
110 |
Accuracy |
111 |
Accuracy - error at normal operation conditions:t=23±20Catmospheric pressure = 84-106.7 kPà (from 630 to 800 mm Hg)working position in accordance with TU for a transmitter. |
112 |
0.075 |
113 |
0.1 |
114 |
0.2 |
115 |
Ex-Certification |
116 |
Modification on purpose means the following:0ExiaIICT5X - transmitter modification with the explosion protection type explosion-proof electrical circuit.1ExdIICT5(T6)X - transmitter modification with the explosion protection type explosion-proof enclosure.Nonexplosion-proof - transmitter modification without special safety requirements. |
117 |
None |
118 |
0ExiaIICT5X |
119 |
1ExdIICT5(T6)X |
120 |
Oxygen modification means that working cavities of transmitters and parts of mounting sets, which contact with oxygen, are cleaned and degreased |
121 |
Special Application |
122 |
Oxygen |
123 |
Product Date - Product date of the transmitter from the manufacturer |
124 |
Product Date |
125 |
Isolator Material |
126 |
Sensor Isolator Material- Construction material of a part of the module that comes in constact with the process material |
127 |
316L SST |
128 |
Hastelloy |
129 |
Tantalum |
130 |
Process Conn Matl |
131 |
Process Connector Material- Construction material of the process connector. |
132 |
O-ring Material |
133 |
Viton |
134 |
PTFE |
135 |
Aflas |
136 |
Kalres |
137 |
Fill Fluid |
138 |
Silicone oil |
139 |
Inert Fill |
140 |
Temp. range |
141 |
-40°C to +80°C |
142 |
-55°C to +80°C |
143 |
Sensor unit |
144 |
USL |
145 |
LSL |
146 |
UTP |
147 |
LTP |
148 |
DAC Temperature |
149 |
Burst command |
150 |
NONE |
151 |
Test device |
152 |
Status |
153 |
Output Condition |
154 |
Write Protect |
155 |
Sensor trim |
156 |
Sensor |
157 |
Signal Condition |
158 |
Sensor Trim |
159 |
Detailed Setup |
160 |
Range values |
161 |
Re-range |
162 |
Keypad Input |
163 |
Settings |
164 |
Specification |
165 |
Special Options |
166 |
Sensor limits |
167 |
Recall AO Fact Trim |
168 |
Primary Variable |
169 |
Configuration |
170 |
Diagnostics |
171 |
Basic Setup |
172 |
Pressure Setup |
173 |
Range Points |
174 |
Sensor Limits |
175 |
Device Configuration |
176 |
Device Tag |
177 |
Identification |
178 |
Change Write Protect |
179 |
Comm Setup |
180 |
Revision Numbers |
181 |
Burst Mode |
182 |
Communication Settings |
183 |
Materials of Construction |
184 |
Matls of Construction |
185 |
Variables Configuration |
186 |
Pressure Limits |
187 |
Temperature Setup |
188 |
Process Variable Information |
189 |
Primary variable: Pressure |
190 |
Rerange Using Applied Values |
191 |
Analog Output Information |
192 |
Calibration |
193 |
Analog Calibration |
194 |
Analog Output Trim |
195 |
Analog Output Verify |
196 |
Pressure Calibration |
197 |
Last Trim Points |
198 |
Failed |
199 |
Transmitter Failure |
200 |
Maintenance |
201 |
Operational |
202 |
Advisory |
203 |
Additional status |
204 |
AO |
205 |
All Variables |
206 |
Sensor Limit |
207 |
Pressure Range |
208 |
Primary Value |
209 |
PV range |
210 |
Lower range value |
211 |
Upper range value |
212 |
AO range |
213 |
mA |
214 |
M-150 |
215 |
METRAN |
216 |
Memory Status |
217 |
Chart |
218 |
PV Analog Output |
219 |
Recall snsr Fact Trim |
220 |
Reset Config. Changed Flag |
221 |
Write Password |
222 |
Pressure Sensor Lower Trim- Calibrate the pressure sensor. |
223 |
Lower sensor trim |
224 |
Pressure Sensor Upper Trim- Calibrate the pressure sensor. |
225 |
Upper sensor trim |
226 |
Exit Trim Mode- Notifies the User that the trim is finished. |
227 |
Send RV |
228 |
PV Damp |
229 |
EEPROM writing error |
230 |
Incorrect reading from AD |
231 |
Unknown subcommand |
232 |
Common Tables |
233 |
Interoperable * |
234 |
Universal |
235 |
Common Practice |
236 |
Pressure Universal |
237 |
Pressure Common |
238 |
Menu |
239 |
Rosemount Magflow |
240 |
Rosemount Pressure |
241 |
Moore Products |
242 |
Siemens Pressure |
243 |
P2 Common |
244 |
PV |
245 |
Munge |
246 |
Analytical Oxygen/Combustion/Methane/CO |
247 |
Flow Totalizer - Rate Indicator |
248 |
Flow Variable Area |
249 |
Flow Coriolis Mass |
250 |
Level Ultrasonic |
251 |
Level Radar - Microwave |
252 |
Pressure Absolute |
253 |
Level Capacitance |
254 |
Pressure Differential |
255 |
Level Hydrostatic |
256 |
Level |
257 |
Pressure Absolute/Relative |
258 |
Level Microwave |
259 |
Level Radar |
260 |
Level Density - Nuclear |
261 |
Pressure Deltabar S Evolution |
262 |
Pressure Cerabar S Evolution |
263 |
Flow Electromagnetic |
264 |
Flow Vortex |
265 |
Flow Magmeter - Rack Version |
266 |
Flow High Performance Magmeter |
267 |
Flow Mass |
268 |
Flow Ultrasonic |
269 |
Flow Magnetic |
270 |
Flow Magnetic - Custody Transfer |
271 |
Flow 2-wire Magnetic |
272 |
Flow Coriolis Mass - Custody Transfer |
273 |
Flow 2-wire Vortex |
274 |
Flow Thermal |
275 |
Temperature Head Mounted |
276 |
Temperature Compact |
277 |
Temperature DIN Rail Mounted |
278 |
Analytical pH |
279 |
Analytical Conductivity - Conductive |
280 |
Analytical Conductivity - Inductive |
281 |
Temperature Sensor |
282 |
Level Servo |
283 |
Temperature DIN Rail |
284 |
Analytical ORP |
285 |
Analytical pION |
286 |
Analytical IConc |
287 |
Analytical Electrode Conductivity |
288 |
Analytical Toroidal Conductivity |
289 |
Valve Controller |
290 |
Pressure Multivariable |
291 |
Analytical pH/ORP |
292 |
Flow Coriolis |
293 |
Analytical Conductivity |
294 |
Valve Positioner/Pneumatic |
295 |
Temperature Dual Input |
296 |
Valve Actuator |
297 |
Analytical Density - Nuclear |
298 |
Level Continuous Gamma |
299 |
Level Laser Ranging |
300 |
Pressure Safety |
301 |
Pressure P, dP + Multivariable |
302 |
Temperature 2-wire |
303 |
Pressure w/ PID |
304 |
Pressure Saturated Steam |
305 |
Analytical Density - Gamma Ray |
306 |
Level Gamma Ray |
307 |
Analytical Weight - Gamma Ray |
308 |
Level w/ Density - Gamma Ray |
309 |
Analytical Motorized Density |
310 |
Flow Multivariable Mass |
311 |
Temperature Multivariable |
312 |
Specialty HART-to-Analog Signal Conv |
313 |
Flow dP |
314 |
Pressure Low Power |
315 |
Pressure Certified SIL2 |
316 |
Interoperable |
317 |
Analytical Density |
318 |
Valve Positioner/Electropneumatic |
319 |
Flow Magnetic Inductive |
320 |
Flow |
321 |
Analytical Oxygen |
322 |
Analytical |
323 |
Analytical Opacity Monitor |
324 |
Analytical Oxygen/Combustion |
325 |
Analytical 2-wire Conductivity |
326 |
Analytical 2-wire Conductivity w/ pure H20 |
327 |
Analytical 2-wire Conductivity w/ % conc |
328 |
Analytical 2-wire Oxygen/Chlorine/Ozone |
329 |
Analytical 2-wire pH/ORP |
330 |
Analytical 2-wire Contacting/Toroidal |
331 |
Analytical Oxygen - High Temperature |
332 |
Analytical Conductivity w/ % conc |
333 |
Analytical pH/ORP/ISE |
334 |
Analytical Amperometric Analyzer |
335 |
Pressure Pressure/Level |
336 |
Analytical Consistency |
337 |
Analytical Microwave-Pulp Consistency |
338 |
Valve Digital Positioner |
339 |
Valve Positioner |
340 |
Valve Smart Valve Positioner |
341 |
Temperature Differential |
342 |
Analytical Dissolved Oxygen |
343 |
Analytical pH Controller |
344 |
Analytical Conductivity/Resistivity Controller |
345 |
Analytical Conductivity/Resistivity |
346 |
Level Displacement |
347 |
Temperature w/ PID |
348 |
Valve Universal Positioner |
349 |
Level Radar - Reflex |
350 |
Valve Digital Positioner w/ PID |
351 |
Valve Intelligent Positioner |
352 |
Analytical Gas Detector |
353 |
Analytical Infrared Gas Detector |
354 |
Analytical Electrochemical Gas Detector |
355 |
Level Magnostrictive |
356 |
Valve On/Off Valve Controller |
357 |
Level Radar - Pulse |
358 |
Analytical Corrosion |
359 |
Level Continuous Capactive |
360 |
Valve Damper Actuator |
361 |
Valve Electric Damper Actuator |
362 |
Flow Electronic |
363 |
Flow Vortex - Multiparameter Mass |
364 |
Analytical Flame Detector |
365 |
Level Nuclear |
366 |
Analytical Density - Radiometric |
367 |
Level Radiometric |
368 |
Analytical Gas/Steam |
369 |
Level Nucleonic |
370 |
Analytical Blade Consistency |
371 |
Analytical Rotary Consistency |
372 |
FMU860 |
373 |
DT |
374 |
DVC |
375 |
FCX |
376 |
AS800 |
377 |
340T |
378 |
340C |
379 |
344 |
380 |
Siemens Micro K |
381 |
SITRANS L |
382 |
SIPAN PH |
383 |
SITRANS P |
384 |
75SMT |
385 |
UNIDELTA |
386 |
8320 |
387 |
SX5100 |
388 |
TSV175 |
389 |
DMU |
390 |
3780 |
391 |
BM70 |
392 |
8u |
393 |
6.4f |
394 |
Wait... |
395 |
Enter Password: |
396 |
Apply low pressure |
397 |
Press OK when pressure is stable |
398 |
Enter applied pressure value |
399 |
trim_point |
400 |
Remove pressure |
401 |
Apply hi pressure |
402 |
Trim was not done |
403 |
Device self test in progress... |
404 |
Choose damping value(%{0}): |
405 |
0.045 sec;0.5 sec;1.2 sec;2.5 sec;5.0 sec;10.0 sec;20.0 sec;40.0 sec |