0 |
To change the Write Protect:Copy Tag content to Message field and apply the changes,then press Zero button on the device's housing withing 10 sec |
1 |
Type |
2 |
M100 |
3 |
Metran |
4 |
Transmitter rev |
5 |
Device Status |
6 |
Primary Variable Out of Limits |
7 |
Non Primary Variable Out of Limits |
8 |
mA Output Saturated |
9 |
mA Output Fixed |
10 |
Additional Status Available |
11 |
Cold Start |
12 |
Configuration Changed |
13 |
Configuration Changed: Any user configurable data was changed.
|
14 |
Transmitter Maltifunction |
15 |
Transmitter S/N |
16 |
Polling Address |
17 |
Dev ID |
18 |
Transmitter Malfunction |
19 |
Master reset |
20 |
Analog output trim |
21 |
Incorrect reading Tau from EEPROM DAC |
22 |
Incorrect reading control byte from EEPROM DAC board |
23 |
Incorrect read temperature codes |
24 |
EEPROM ADC board invalid |
25 |
Invalid sensor info |
26 |
Set technology mode |
27 |
EEPROM Chech sum error |
28 |
Incorrect reading internal range number |
29 |
Error Check-summ drift Zero #1 |
30 |
Error Check-summ LRV |
31 |
Error Check-summ param gain #1 |
32 |
Error Check-summ drift Zero #2 |
33 |
Error Check-summ param gain #2 |
34 |
Error Check-summ drift DAC |
35 |
Error Check-summ gain DAC |
36 |
Error Check-summ span pressure |
37 |
Percent of Range |
38 |
Analog Output |
39 |
AO Alarm Type |
40 |
Transfer function |
41 |
|
42 |
Upper Range Value |
43 |
.6f |
44 |
.1f |
45 |
.4f |
46 |
.7f |
47 |
.2f |
48 |
.3f |
49 |
Lower Range Value |
50 |
Lower Sensor Trim Point - The pressure at which the last low sensor trim was performed. |
51 |
Lower Trim Point |
52 |
Upper Sensor Trim Point - The pressure at which the last upper sensor trim was performed. |
53 |
Upper Trim Point |
54 |
EEPROM writing error |
55 |
Pressure |
56 |
Upper Sensor Limit |
57 |
Lower Sensor Limit |
58 |
Damping |
59 |
5.2f |
60 |
s |
61 |
Ex-Certification |
62 |
Ex-Certification - explosion proof type |
63 |
None |
64 |
0(1)Exia(b)IICT5 X |
65 |
1ExdsIIBT4/H2 X |
66 |
AS |
67 |
Climatic modification - operation conditions depending on ambient climatic factors influence. |
68 |
Climatic |
69 |
U2 |
70 |
UKhL |
71 |
T3 |
72 |
TS |
73 |
TV1 |
74 |
U1 |
75 |
TM1 |
76 |
Maximum permissible working gage pressure- Maximum value of static pressure. This notion is applied only for DD and DG transmitter. |
77 |
Max gage pressure kPa |
78 |
Model |
79 |
4d |
80 |
Sensor S/N |
81 |
7d |
82 |
Oxygen modification means that working cavities of transmitters and parts of mounting sets, which contact with oxygen, are cleaned and degreased |
83 |
Special Application |
84 |
Oxygen |
85 |
Product Date - Product date of the transmitter from the manufacturer |
86 |
Product Date |
87 |
Accuracy Code |
88 |
Accuracy - error at normal operation conditions:t=23±20Catmospheric pressure = 84-106.7 kPà (from 630 to 800 mm Hg)working position in accordance with TU for a transmitter. |
89 |
010 |
90 |
015 |
91 |
025 |
92 |
050 |
93 |
Isolator Matl |
94 |
Sensor Isolator Material- Construction material of a part of the module that comes in constact with the process material |
95 |
36NiCrTiAl |
96 |
15Cr18Ni12C4TiAl |
97 |
06CrNi28MoCuTi |
98 |
Tantalum |
99 |
Titanium VT-1-0 |
100 |
Titanium alloy |
101 |
Process Conn Matl |
102 |
Process Connector Material- Construction material of the process connector. |
103 |
Carbon steel |
104 |
12Cr18Ni10 |
105 |
10Cr17Ni13Mo2Ti |
106 |
12Cr18Ni10Ti |
107 |
Burst command |
108 |
NONE |
109 |
Sensor unit |
110 |
USL |
111 |
LSL |
112 |
UTP |
113 |
LTP |
114 |
URV |
115 |
LRV |
116 |
Lower sensor trim |
117 |
Upper sensor trim |
118 |
Exit Trim Mode- Notifies the User that the trim is finished. |
119 |
Self Test- Commands the electronics to perform a self test. Reports any errors that occured. |
120 |
Test device |
121 |
Status |
122 |
Output Condition |
123 |
Write Protect |
124 |
Sensor trim |
125 |
Sensor |
126 |
Signal Condition |
127 |
Sensor Trim |
128 |
Detailed Setup |
129 |
Range values |
130 |
Re-range |
131 |
Keypad Input |
132 |
Specification |
133 |
Special Options |
134 |
Sensor limits |
135 |
Primary Variable |
136 |
Pimery variable: Pressure |
137 |
Configuration |
138 |
Diagnostics |
139 |
Basic Setup |
140 |
Pressure Setup |
141 |
Range Points |
142 |
Sensor Limits |
143 |
Device Configuration |
144 |
Device Tag |
145 |
Identification |
146 |
Comm Setup |
147 |
Revision Numbers |
148 |
Burst Mode |
149 |
Communication Settings |
150 |
Materials of Construction |
151 |
Matls of Construction |
152 |
Variables Configuration |
153 |
Pressure Limits |
154 |
Process Variable Information |
155 |
Rerange Using Applied Values |
156 |
Analog Output Information |
157 |
Calibration |
158 |
Analog Calibration |
159 |
Analog Output Trim |
160 |
Analog Output Verify |
161 |
Pressure Calibration |
162 |
Last Trim Points |
163 |
Failed |
164 |
Transmitter Failure |
165 |
Maintenance |
166 |
Operational |
167 |
Advisory |
168 |
Additional status |
169 |
Additional status Byte 0 |
170 |
Additional status Byte 1 |
171 |
AO |
172 |
All Variables |
173 |
Sensor Limit |
174 |
Pressure Range |
175 |
Primary Value |
176 |
PV range |
177 |
Lower range value |
178 |
Upper range value |
179 |
AO range |
180 |
mA |
181 |
M-100 |
182 |
METRAN |
183 |
Memory Status |
184 |
Chart |
185 |
PV Analog Output |
186 |
Send RV |
187 |
Reset Config. Changed flag |
188 |
Common Tables |
189 |
Interoperable * |
190 |
Universal |
191 |
Common Practice |
192 |
Pressure Universal |
193 |
Pressure Common |
194 |
Menu |
195 |
Rosemount Magflow |
196 |
Rosemount Pressure |
197 |
Moore Products |
198 |
Siemens Pressure |
199 |
P2 Common |
200 |
PV |
201 |
Munge |
202 |
Analytical Oxygen/Combustion/Methane/CO |
203 |
Flow Totalizer - Rate Indicator |
204 |
Flow Variable Area |
205 |
Flow Coriolis Mass |
206 |
Level Ultrasonic |
207 |
Level Radar - Microwave |
208 |
Pressure Absolute |
209 |
Level Capacitance |
210 |
Pressure Differential |
211 |
Level Hydrostatic |
212 |
Level |
213 |
Pressure Absolute/Relative |
214 |
Level Microwave |
215 |
Level Radar |
216 |
Level Density - Nuclear |
217 |
Pressure Deltabar S Evolution |
218 |
Pressure Cerabar S Evolution |
219 |
Flow Electromagnetic |
220 |
Flow Vortex |
221 |
Flow Magmeter - Rack Version |
222 |
Flow High Performance Magmeter |
223 |
Flow Mass |
224 |
Flow Ultrasonic |
225 |
Flow Magnetic |
226 |
Flow Magnetic - Custody Transfer |
227 |
Flow 2-wire Magnetic |
228 |
Flow Coriolis Mass - Custody Transfer |
229 |
Flow 2-wire Vortex |
230 |
Flow Thermal |
231 |
Temperature Head Mounted |
232 |
Temperature Compact |
233 |
Temperature DIN Rail Mounted |
234 |
Analytical pH |
235 |
Analytical Conductivity - Conductive |
236 |
Analytical Conductivity - Inductive |
237 |
Temperature Sensor |
238 |
Level Servo |
239 |
Temperature DIN Rail |
240 |
Temperature |
241 |
Analytical ORP |
242 |
Analytical pION |
243 |
Analytical IConc |
244 |
Analytical Electrode Conductivity |
245 |
Analytical Toroidal Conductivity |
246 |
Valve Controller |
247 |
Pressure Multivariable |
248 |
Analytical pH/ORP |
249 |
Flow Coriolis |
250 |
Analytical Conductivity |
251 |
Valve Positioner/Pneumatic |
252 |
Temperature Dual Input |
253 |
Valve Actuator |
254 |
Analytical Density - Nuclear |
255 |
Level Continuous Gamma |
256 |
Level Laser Ranging |
257 |
Pressure Safety |
258 |
Pressure P, dP + Multivariable |
259 |
Temperature 2-wire |
260 |
Pressure w/ PID |
261 |
Pressure Saturated Steam |
262 |
Analytical Density - Gamma Ray |
263 |
Level Gamma Ray |
264 |
Analytical Weight - Gamma Ray |
265 |
Level w/ Density - Gamma Ray |
266 |
Analytical Motorized Density |
267 |
Flow Multivariable Mass |
268 |
Temperature Multivariable |
269 |
Specialty HART-to-Analog Signal Conv |
270 |
Flow dP |
271 |
Pressure Low Power |
272 |
Pressure Certified SIL2 |
273 |
Interoperable |
274 |
Analytical Density |
275 |
Valve Positioner/Electropneumatic |
276 |
Flow Magnetic Inductive |
277 |
Flow |
278 |
Analytical Oxygen |
279 |
Analytical |
280 |
Analytical Opacity Monitor |
281 |
Analytical Oxygen/Combustion |
282 |
Analytical 2-wire Conductivity |
283 |
Analytical 2-wire Conductivity w/ pure H20 |
284 |
Analytical 2-wire Conductivity w/ % conc |
285 |
Analytical 2-wire Oxygen/Chlorine/Ozone |
286 |
Analytical 2-wire pH/ORP |
287 |
Analytical 2-wire Contacting/Toroidal |
288 |
Analytical Oxygen - High Temperature |
289 |
Analytical Conductivity w/ % conc |
290 |
Analytical pH/ORP/ISE |
291 |
Analytical Amperometric Analyzer |
292 |
Pressure Pressure/Level |
293 |
Analytical Consistency |
294 |
Analytical Microwave-Pulp Consistency |
295 |
Valve Digital Positioner |
296 |
Valve Positioner |
297 |
Valve Smart Valve Positioner |
298 |
Temperature Differential |
299 |
Analytical Dissolved Oxygen |
300 |
Analytical pH Controller |
301 |
Analytical Conductivity/Resistivity Controller |
302 |
Analytical Conductivity/Resistivity |
303 |
Level Displacement |
304 |
Temperature w/ PID |
305 |
Valve Universal Positioner |
306 |
Level Radar - Reflex |
307 |
Valve Digital Positioner w/ PID |
308 |
Valve Intelligent Positioner |
309 |
Analytical Gas Detector |
310 |
Analytical Infrared Gas Detector |
311 |
Analytical Electrochemical Gas Detector |
312 |
Level Magnostrictive |
313 |
Valve On/Off Valve Controller |
314 |
Level Radar - Pulse |
315 |
Analytical Corrosion |
316 |
Level Continuous Capactive |
317 |
Valve Damper Actuator |
318 |
Valve Electric Damper Actuator |
319 |
Flow Electronic |
320 |
Flow Vortex - Multiparameter Mass |
321 |
Analytical Flame Detector |
322 |
Level Nuclear |
323 |
Analytical Density - Radiometric |
324 |
Level Radiometric |
325 |
Analytical Gas/Steam |
326 |
Level Nucleonic |
327 |
Analytical Blade Consistency |
328 |
Analytical Rotary Consistency |
329 |
FMU860 |
330 |
DT |
331 |
DVC |
332 |
FCX |
333 |
AS800 |
334 |
340T |
335 |
340C |
336 |
344 |
337 |
Siemens Micro K |
338 |
SITRANS L |
339 |
SIPAN PH |
340 |
SITRANS P |
341 |
75SMT |
342 |
UNIDELTA |
343 |
8320 |
344 |
SX5100 |
345 |
TSV175 |
346 |
DMU |
347 |
3780 |
348 |
BM70 |
349 |
8u |
350 |
8.3f |
351 |
6.4f |
352 |
Enter apllied pressure value. Pressure units: %{0} |
353 |
trim_point |
354 |
Trim was not done |
355 |
Aborting method due to last error |
356 |
Device maybe stuck in self test. |
357 |
Self test OK |
358 |
Wait... |