0 |
UltimaXL/XT |
1 |
MSA |
2 |
PV Out of Limit |
3 |
HELP - Bit 0 |
4 |
Non PV- Out of Limit |
5 |
HELP - Bit 1 |
6 |
PV Analog Out - Saturated |
7 |
HELP - Bit 2 |
8 |
PV Analog Out - Fixed |
9 |
HELP - Bit 3 |
10 |
More Staus Available |
11 |
HELP - Bit 4 |
12 |
Cold Start |
13 |
HELP - Bit 5 |
14 |
Config Changed |
15 |
HELP - Bit 6 |
16 |
Device Malfunction |
17 |
HELP - Bit 7 |
18 |
Configuration Reset |
19 |
Main ram fault |
20 |
Main flash fault |
21 |
EEprom write error |
22 |
Incompatible sensor |
23 |
Sensor quick underrange |
24 |
Sensor underrange |
25 |
Calibration fault |
26 |
Sensor Missing |
27 |
No sensor detected |
28 |
Sensor Overrange |
29 |
Sensor reading overrange! |
30 |
Sensor in Overrange Loc |
31 |
Combustible sensor in overrange lock! |
32 |
Sensor Parameter Fault |
33 |
Sensor Warm up |
34 |
Sensor Warming up |
35 |
Sensor Config Reset |
36 |
Sensor Configuration has been reset |
37 |
Sensor Power Fault |
38 |
Sensor Power Fault detected |
39 |
5V Power Fault |
40 |
Main board 5V Power Fault detected |
41 |
Zero Countdn |
42 |
Cal- 30sec Zero Countdn |
43 |
Apply Zero Gas |
44 |
Cal- Waiting for Zero Gas |
45 |
Span Countdn |
46 |
Cal- 30s Span Countdn |
47 |
Apply Span Gas |
48 |
Cal- Waiting for Span Gas |
49 |
Cal Aborted |
50 |
Calibration sequence aborted |
51 |
Zero Fault |
52 |
Sensor failed Zero Cal |
53 |
Span Fault |
54 |
Sensor failed Span Cal |
55 |
Cal OK |
56 |
Calibration Successful |
57 |
Change Snsr Warn |
58 |
Sensor End Of Life Warning |
59 |
Snsr Swap Delay |
60 |
Sensor missing error held off during 2 min sensor Swap Delay, |
61 |
Change Snsr Fault |
62 |
Sensor End of Life indication |
63 |
Snsr Pwr Fault |
64 |
Sensor input voltage out of 7-30 volt range |
65 |
Device Comm Fault |
66 |
Sensor internal communications fault detected |
67 |
Cal Signal Enable |
68 |
Sets output set to 3.75 ma during cal and for 1 min after cal |
69 |
Alert Option Enable |
70 |
Alert option on sets cal output to 21 ma when Cal sig enabled |
71 |
Not Used |
72 |
Alarm1 Set |
73 |
Alarm 1 limit exceeded! |
74 |
Alarm2 Set |
75 |
Alarm 2 limit exceeded! |
76 |
Alarm3 Set |
77 |
Not Used |
78 |
Sensor Value(PV) |
79 |
.2f |
80 |
Snsr Dev fmly |
81 |
Snsr Class |
82 |
Snsr PDQ |
83 |
Snsr LS |
84 |
Snsr Fmly stat |
85 |
Snsr Upper Limit |
86 |
Snsr Lower Limit |
87 |
Snsr Minimum Span |
88 |
Snsr Damping |
89 |
.3f |
90 |
8.3f |
91 |
Sensor Serial Number |
92 |
7d |
93 |
Snsr Lower trim |
94 |
Snsr Upper trim |
95 |
4.2f |
96 |
Snsr Trim support |
97 |
Snsr Min lower trim |
98 |
Snsr Max lower trim |
99 |
Snsr Min upper trim |
100 |
Snsr Max upper trim |
101 |
Snsr Min trim diff |
102 |
Gas Snsr |
103 |
Input Voltage |
104 |
Input voltage monitor |
105 |
volts |
106 |
.1f |
107 |
Gas table |
108 |
Gas specific calibration look up table |
109 |
Methane |
110 |
Uses methane analyte curve |
111 |
Propane |
112 |
Uses propane analyte curve |
113 |
Ethane |
114 |
Uses ethane analyte curve |
115 |
n-Butane |
116 |
Uses n-butane analyte curve |
117 |
n-Pentane |
118 |
Uses n-pentane analyte curve |
119 |
n-Hexane |
120 |
Uses n-hexane analyte curve |
121 |
Cyclopentane |
122 |
Uses cyclopentane analyte curve |
123 |
Ethylene |
124 |
Uses ethylene analyte curve |
125 |
Acetylene |
126 |
Uses acetylene analyte curve |
127 |
5000 PPM CO2 |
128 |
Uses 5000PPM CO2 analyte curve |
129 |
5% CO2 |
130 |
Uses 5% CO2 analyte curve |
131 |
2% CO2 |
132 |
Uses 2% CO2 analyte curve |
133 |
Custom |
134 |
Uses custom analyte curve |
135 |
Unused |
136 |
Gas tables unused |
137 |
RTC Hrs |
138 |
Real time clock - hours |
139 |
hrs |
140 |
2d |
141 |
3d |
142 |
RTC Minutes |
143 |
Real time clock - minutes |
144 |
mins |
145 |
min value |
146 |
Minimum gas value reading recorded during average interval. |
147 |
max value |
148 |
Maximum gas reading recorded during average interval. |
149 |
avg value |
150 |
Average gas reading recorded during the average interval |
151 |
avg interval |
152 |
Time interval in hours(1,8, or 24) for which the min, max and average values are accumulated. |
153 |
hr |
154 |
alm1 setpoint |
155 |
Gas level at which alarm 1 will be set |
156 |
alm2 setpoint |
157 |
Gas level at which alarm 2 will be set |
158 |
alm3 setpoint |
159 |
Gas level at which alarm 3 will be set |
160 |
Setpoint edit val |
161 |
|
162 |
Alm edit num |
163 |
number of the alarm to be edited(1,2 or 3) |
164 |
Alarm Actions |
165 |
Defines the direction, latch and enable modes of the setpoint alarm |
166 |
alarm enable |
167 |
Alarm - enabled = 1 |
168 |
alarm increasing |
169 |
Alarm - increasing = 1, decreasing = 0 |
170 |
alarm latching |
171 |
Alarm - latching = 1 |
172 |
alm1 actions |
173 |
Setpoint alarm 1 control actions |
174 |
alm 1 enable |
175 |
Alarm 1 - enabled = 1 |
176 |
alm 1 inc |
177 |
Alarm 1 - increasing = 1, decreasing = 0 |
178 |
alm 1 latch |
179 |
Alarm 1 - latching = 1 |
180 |
alm2 actions |
181 |
Setpoint alarm 2 control actions |
182 |
alm 2 enable |
183 |
Alarm 2 - enabled = 1 |
184 |
alm 2 inc |
185 |
Alarm 2 - increasing = 1, decreasing = 0 |
186 |
alm 2 latch |
187 |
Alarm 2 - latching = 1 |
188 |
alm3 actions |
189 |
Setpoint alarm 3 control actions |
190 |
alm 3 enable |
191 |
Alarm 3 - enabled = 1 |
192 |
alm 3 inc |
193 |
Alarm 3 - increasing = 1, decreasing = 0 |
194 |
alm 3 latch |
195 |
Alarm 3 - latching = 1 |
196 |
Cal Mode |
197 |
Calibration mode selection variable |
198 |
Sensor Zero |
199 |
Initiates sensor Zero sequence |
200 |
Standard Cal |
201 |
Iniiates a Standard Zero and Span sequence |
202 |
Initial Cal |
203 |
Initiates an Initial Zero and Span sequence |
204 |
User Cal |
205 |
Initiates a manual User controlled cal sequence |
206 |
cal abort |
207 |
Calibration abort command byte |
208 |
Step Cal |
209 |
Calibration step command byte |
210 |
alm ack |
211 |
Alarm acknowledge command byte |
212 |
Auto Zero Comp |
213 |
Indicates the amount of automatic zero compensation added since last calibration |
214 |
Last Cal Date |
215 |
Indicates the date the sensor module was last calibrated |
216 |
Cal Signal |
217 |
When enabled, causes the 4-20 ma to be set to 3.75 ma during calibration |
218 |
Disabled |
219 |
Causes the output 4-20 ma signal to follow the gas reading during Cal |
220 |
Enabled |
221 |
Causes the output 4-20 ma to be set to 3.75 ma during Cal( 21 ma for Oxygen) |
222 |
Swap Delay |
223 |
Enables a 1 min hold off on sensor missing status bit and output current fault during sensor exchange |
224 |
Enables immediate Sensor Missing status bit on loss of sensor communication |
225 |
Enables a 1 min hold off on sensor missing status bit and output current fault during sensor exchange |
226 |
dataResetCmd |
227 |
Sensor data sheet reset command byte |
228 |
Sensor Status |
229 |
Status message from sensor module to transmitter |
230 |
SNSR Flash Flt |
231 |
help |
232 |
SNSR RAM Flt |
233 |
SNSR Pellement Flt |
234 |
SNSR TEDS Chksum Flt |
235 |
SNSR Pwr Flt |
236 |
SNSR IR Factory Mode |
237 |
SNSR IR Lamp Flt |
238 |
SNSR EEPROM R/W Flt |
239 |
SNSR EEPROM Chksum Flt |
240 |
SNSR Missing Flt |
241 |
SNSR Neg Pwr Flt |
242 |
SNSR IR Ref Flt |
243 |
SNSR Temp Flt |
244 |
SNSR IR Analyt Flt |
245 |
SNSR IR Low Sig Flt |
246 |
SNSR IR Param Flt |
247 |
SNSR Cal Flt |
248 |
SNSR Zero Mode |
249 |
SNSR Span Mode |
250 |
SNSR Sleep Mode |
251 |
SNSR Warm Up Mode |
252 |
SNSR POR Mode |
253 |
SNSR OK |
254 |
Main Code Ver |
255 |
main processor code version |
256 |
Snsr Temp |
257 |
Temperature reading from sensor module |
258 |
C |
259 |
Alert Option |
260 |
Sets output to 3.75 ma during cal of an Oxygen sensor if Cal sig is also enabled) |
261 |
Causes the output 4-20 ma to be set to 3.75 ma during Cal of an Oxygen sensor if Cal signal is enabled) |
262 |
Write Protect Mode |
263 |
Write protects device preventing variables or calibration from being changed |
264 |
Device write protection is disabled |
265 |
Device write protection is enabled |
266 |
DR_Initiate |
267 |
DR_Running |
268 |
DR_Conflict |
269 |
Sensor Calibration |
270 |
Abort Cal |
271 |
aborts device calibration sequence |
272 |
cal fault |
273 |
Alarm Function Edit |
274 |
Changes the alarm function controls |
275 |
Setpoint Edit |
276 |
Changes the device alarm level settings |
277 |
Clear Config Flag |
278 |
Clears device configuration flag |
279 |
Alarm Acknowledge |
280 |
Acknowledges latched alarms in the device |
281 |
Set Avg Interval |
282 |
Select a time collection interval for Min, Max and Average readings |
283 |
Sensor Reset |
284 |
Reset Sensor module to factory defaults |
285 |
Enable or disable device write protect mode |
286 |
Re-range |
287 |
Abgl.punkte Sensor |
288 |
Alarm Edit |
289 |
Clock edit |
290 |
Gas Sensor |
291 |
Edit Menu |
292 |
Cal Menu |
293 |
Swap Delay Edit |
294 |
Write Protect Edit |
295 |
8u |
296 |
Output Status |
297 |
Output Status Byte |
298 |
Uninitialized |
299 |
Normal - one sensor |
300 |
Normal - two sensors |
301 |
Normal - three sensors |
302 |
Shorted |
303 |
Shorted- shorted field wiring. |
304 |
Limited high |
305 |
Limited high- block can not respond to upward movement of value. |
306 |
Open |
307 |
Open- open field wiring. |
308 |
Limited low |
309 |
Limited low- block can not respond to upward movement of target. |
310 |
Initialization done |
311 |
Initialization done- block initialization is complete. |
312 |
Not selected |
313 |
Not selected- target value provided by block was not selected. |
314 |
No path |
315 |
No path- there is no path to the process. |
316 |
Fail |
317 |
Fail- hardware failure. |
318 |
Bad |
319 |
Bad- block is out of service or has bad input. |
320 |
Not from process |
321 |
Not from process- value is not directly affected by any process information. |
322 |
Local override |
323 |
Local override- block has LO mode. |
324 |
Not Cascade Mode |
325 |
Not RCas Mode |
326 |
Not ROut Mode |
327 |
No communication |
328 |
No communication- (NO_COM). |
329 |
uint16_var_blk_char |
330 |
uint32_var_blk_char |
331 |
uint8_var_blk_char |
332 |
int8_var_blk_char |
333 |
new itest redef1 label |