0 |
Sensor default |
1 |
Configuration default |
2 |
System default |
3 |
Self test result |
4 |
Meas. Unit |
5 |
Sensor temperature unit - Engineering unit to be displayed with sensor temperature |
6 |
Temperature Class |
7 |
Temperature PDQ |
8 |
|
9 |
Temperature LS |
10 |
Temperature device status |
11 |
Probe Break Detected |
12 |
Upper probe limit |
13 |
.3f |
14 |
Lower probe limit |
15 |
Temperature minimum span |
16 |
8.3f |
17 |
Temperature update period |
18 |
s |
19 |
Serial number of temperature sensor |
20 |
7d |
21 |
Simulate |
22 |
Primary Variable - Temperature |
23 |
Update period |
24 |
Setup |
25 |
Temperature sensor |
26 |
Manufacturer specific setup |
27 |
Temperature family setup |
28 |
Line compensation resistance (Ohms) |
29 |
.2f |
30 |
Device Reset |
31 |
Reset default configuration |
32 |
Transducer MCU firmware |
33 |
Nbr. Wires |
34 |
Number of wires linked to the probe |
35 |
2 Wires |
36 |
3 Wires |
37 |
4 Wires |
38 |
Probe Type |
39 |
Probe type linked to the device |
40 |
Voltage -10..60 mV |
41 |
Resistance 0..360 Ohms |
42 |
Resistance 0..4000 Ohms |
43 |
Probe PT100 |
44 |
Probe PT1000 |
45 |
Probe NI100 |
46 |
Probe NI1000 |
47 |
Probe TC type J |
48 |
Probe TC type K |
49 |
Probe TC type B |
50 |
Probe TC type R |
51 |
Probe TC type S |
52 |
Probe TC type T |
53 |
Probe TC type E |
54 |
Probe TC type N |
55 |
Probe TC type W |
56 |
Temperature standard |
57 |
ITS-90 |
58 |
Probe connection type |
59 |
Single |
60 |
Differential |
61 |
Cold junction compensation type |
62 |
Internal |
63 |
External |
64 |
Manual cold junction compensation |
65 |
Not Used |
66 |
Sensor temperature unit |
67 |
Sensor temperature unit - Engineering unit to be displayed with sensor temperature |
68 |
Unsupported probe type |
69 |
Invalid number of wires |
70 |
Set probe configuration |
71 |
Invalid cold junction compensation type |
72 |
PV Analog Channel Saturated |
73 |
PV Analog Channel Fixed |
74 |
Wireless |
75 |
WirelessHART Device |
76 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
77 |
Primary |
78 |
Primary Analog Channel |
79 |
Secondary |
80 |
Secondary Analog Channel |
81 |
Tertiary |
82 |
Tertiary Analog Channel |
83 |
Quaternary |
84 |
Quaternary Analog Channel |
85 |
Quinary |
86 |
Quinary Analog Channel |
87 |
Critical Power Failure |
88 |
Lock all |
89 |
Trim not supported |
90 |
Configuration cannot be changed |
91 |
Locked by gateway |
92 |
Analog Input Channel |
93 |
Analog Output Channel |
94 |
Secondary Analog Channel Saturated |
95 |
Tertiary Analog Channel Saturated |
96 |
Quaternary Analog Channel Saturated |
97 |
Quinary Analog Channel Saturated |
98 |
Secondary Analog Channel Fixed |
99 |
Tertiary Analog Channel Fixed |
100 |
Quaternary Analog Channel Fixed |
101 |
Quinary Analog Channel Fixed |
102 |
Simulation active |
103 |
The device is in simulation mode and the level output is not representative of the process. |
104 |
Non-Volatile memory failure |
105 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
106 |
Volatile memory error |
107 |
The RAM memory check is invalid or maybe corrupt |
108 |
Watchdog reset executed |
109 |
A watchdog reset has been performed |
110 |
Voltage conditions out of range |
111 |
A voltage condition is outside its allowable range |
112 |
Environmental conditions out of range |
113 |
An internal or environmental condition is beyond acceptable limits. |
114 |
Electronic failure |
115 |
A hardware problem not related to the sensor has been detected. |
116 |
Subdevice list changed |
117 |
Duplicate master detected |
118 |
Capacity Denied |
119 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
120 |
Bandwidth allocation pending |
121 |
Block transfer pending |
122 |
Battery life |
123 |
Percent range |
124 |
Loop current |
125 |
Primary variable |
126 |
Secondary variable |
127 |
Tertiary variable |
128 |
Quaternary variable |
129 |
Read receive time |
130 |
Write date and time |
131 |
Non-Volatile Clock |
132 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
133 |
Clock Uninitialized |
134 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
135 |
None |
136 |
No restrictions |
137 |
SI Only |
138 |
Restricted to SI Unit codes only |
139 |
Process automation device |
140 |
Discrete device |
141 |
Hybrid:Process automation+discrete |
142 |
I/O System |
143 |
WirelessHART Process automation device |
144 |
WirelessHART Discrete device |
145 |
WirelessHART Process automation+discrete |
146 |
WirelessHART Gateway |
147 |
WirelessHART Access point |
148 |
WirelessHART Process adapter |
149 |
WirelessHART Discrete adapter |
150 |
WirelessHART enabled handheld/portable maintenance tool |
151 |
Device Profile |
152 |
US |
153 |
United States of America |
154 |
JP |
155 |
Japan |
156 |
DE |
157 |
Germany |
158 |
FR |
159 |
France |
160 |
ES |
161 |
Spain |
162 |
RU |
163 |
Russian Federation |
164 |
CN |
165 |
People's Republic of China |
166 |
Secondary Master |
167 |
Primary Master |
168 |
Device Diagnostic Status 0 |
169 |
Device Diagnostic Status 1 |
170 |
I/O and Subdevice Status |
171 |
WirelessHART Status |
172 |
Time Set Option |
173 |
Real Time Clock Flags |
174 |
Country |
175 |
Country of intended device installation |
176 |
SI Unit Control |
177 |
Indicates if device should only display SI unit codes |
178 |
8u |
179 |
Dynamic Variables Returned for Device Variables |
180 |
Command Response Truncated |
181 |
Configuration Change Counter Mismatch |
182 |
Status bytes mismatch |
183 |
Device Variable |
184 |
Output Status |
185 |
Output Status Byte |
186 |
Uninitialized |
187 |
Normal - one sensor |
188 |
Normal - two sensors |
189 |
Normal - three sensors |
190 |
Shorted |
191 |
Shorted- shorted field wiring. |
192 |
Limited high |
193 |
Limited high- block can not respond to upward movement of value. |
194 |
Open |
195 |
Open- open field wiring. |
196 |
Limited low |
197 |
Limited low- block can not respond to upward movement of target. |
198 |
Initialization done |
199 |
Initialization done- block initialization is complete. |
200 |
Not selected |
201 |
Not selected- target value provided by block was not selected. |
202 |
No path |
203 |
No path- there is no path to the process. |
204 |
Fail |
205 |
Fail- hardware failure. |
206 |
Bad |
207 |
Bad- block is out of service or has bad input. |
208 |
Not from process |
209 |
Not from process- value is not directly affected by any process information. |
210 |
Local override |
211 |
Local override- block has LO mode. |
212 |
Not Cascade Mode |
213 |
Not RCas Mode |
214 |
Not ROut Mode |
215 |
No communication |
216 |
No communication- (NO_COM). |
217 |
uint16_var_blk_char |
218 |
uint32_var_blk_char |
219 |
uint8_var_blk_char |
220 |
int8_var_blk_char |
221 |
new itest redef1 label |