0 |
HRT1 |
1 |
HOFFER FLOW CNTRLS |
2 |
Operation Status |
3 |
Loop Current Override. |
4 |
Dac Gain Not Calibrated. |
5 |
Dac Zero Not Calibrated. |
6 |
Flow rate exceeds display. |
7 |
Flow exceeds 20 mA calibration. |
8 |
Pulse rate overflow. |
9 |
Sample Time Configuration Error. |
10 |
Rate Decimal Pt. Configuration Error. |
11 |
Total Decimal Pt. Configuration Error. |
12 |
Number Of Pts. Configuration Error. |
13 |
KFactor Decimal Pt. Configuration Error. |
14 |
Linearization Configuration Error. |
15 |
Rate Time Units Configuration Error. |
16 |
Total Units Configuration Error. |
17 |
Alarm 1 Function Configuration Error. |
18 |
Alarm 2 Function Configuration Error. |
19 |
Unit Locked. |
20 |
Pulse Frequency Configuration Error. |
21 |
Pulse Scale Configuration Error. |
22 |
Alarm 1 Being Tested. |
23 |
Alarm 2 Being Tested. |
24 |
Pulse Output Being Tested. |
25 |
Alarm 1 Activated |
26 |
Alarm 2 Activated. |
27 |
Electronic Defect |
28 |
Environmental Conditions Out of Range. |
29 |
Voltage Out of Range. |
30 |
Watchdog Reset Executed. |
31 |
Volatile Memory Defect. |
32 |
Non-volatile Memory Defect. |
33 |
Simulation Active. |
34 |
Lower flow rate for 4 mA output. |
35 |
8.0f |
36 |
9.1f |
37 |
9.2f |
38 |
9.3f |
39 |
Upper flow rate for 20 mA output. |
40 |
Rate % Range |
41 |
Flow Rate |
42 |
Total |
43 |
Grand Total |
44 |
Frequency |
45 |
Rate |
46 |
Damping |
47 |
Flow Rate Units |
48 |
l/day |
49 |
Rate of flow expressed as units/time. |
50 |
USL |
51 |
LSL |
52 |
7d |
53 |
Not Classified |
54 |
Rate Units |
55 |
Time base for flowrate measurement. |
56 |
Seconds |
57 |
Minutes |
58 |
Hours |
59 |
Days |
60 |
Units |
61 |
M3 |
62 |
FT3 |
63 |
Flow total in selected units. |
64 |
Grand flow total in selected units. |
65 |
Measured Input Frequency in Hz. |
66 |
5.1f |
67 |
Hz |
68 |
Rate Decimal Point Location |
69 |
Select resolution for displaying flow rate. |
70 |
00000 |
71 |
0000.0 |
72 |
000.00 |
73 |
00.000 |
74 |
Total Decimal Point Location |
75 |
Select resolution for displaying flow total. |
76 |
00000000 |
77 |
0000000.0 |
78 |
000000.00 |
79 |
00000.000 |
80 |
Linearization |
81 |
Select method of flowmeter linearization. |
82 |
Average K factor |
83 |
Linearization Table |
84 |
K Factor Decimal Point Location |
85 |
Select K-Factor resolution. |
86 |
Average K Factor |
87 |
Enter value for Average K-Factor. |
88 |
Number of Points in Table |
89 |
Enter the number of points in linearization table. |
90 |
Correction Factor |
91 |
Enter multiplier to correct flow rate and total. |
92 |
.3f |
93 |
Frequency Pt. 1 |
94 |
Frequency point 1. |
95 |
11.3f |
96 |
Frequency Pt. 2 |
97 |
Frequency point 2. |
98 |
Frequency Pt. 3 |
99 |
Frequency point 3. |
100 |
Frequency Pt. 4 |
101 |
Frequency point 4. |
102 |
Frequency Pt. 5 |
103 |
Frequency point 5. |
104 |
Frequency Pt. 6 |
105 |
Frequency point 6. |
106 |
Frequency Pt. 7 |
107 |
Frequency point 7. |
108 |
Frequency Pt. 8 |
109 |
Frequency point 8. |
110 |
Frequency Pt. 9 |
111 |
Frequency point 9. |
112 |
Frequency Pt. 10 |
113 |
Frequency point 10. |
114 |
Frequency Pt. 11 |
115 |
Frequency point 11. |
116 |
Frequency Pt. 12 |
117 |
Frequency point 12. |
118 |
Frequency Pt. 13 |
119 |
Frequency point 13. |
120 |
Frequency Pt. 14 |
121 |
Frequency point 14. |
122 |
Frequency Pt. 15 |
123 |
Frequency point 15. |
124 |
Frequency Pt. 16 |
125 |
Frequency point 16. |
126 |
Frequency Pt. 17 |
127 |
Frequency point 17. |
128 |
Frequency Pt. 18 |
129 |
Frequency point 18. |
130 |
Frequency Pt. 19 |
131 |
Frequency point 19. |
132 |
Frequency Pt. 20 |
133 |
Frequency point 20. |
134 |
KFactor Pt. 1 |
135 |
K-Factor 1. |
136 |
KFactor Pt. 2 |
137 |
K-Factor 2. |
138 |
KFactor Pt. 3 |
139 |
K-Factor 3. |
140 |
KFactor Pt. 4 |
141 |
K-Factor 4. |
142 |
KFactor Pt. 5 |
143 |
K-Factor 5. |
144 |
KFactor Pt. 6 |
145 |
K-Factor 6. |
146 |
KFactor Pt. 7 |
147 |
K-Factor 7. |
148 |
KFactor Pt. 8 |
149 |
K-Factor 8. |
150 |
KFactor Pt. 9 |
151 |
K-Factor 9. |
152 |
KFactor Pt. 10 |
153 |
K-Factor 10. |
154 |
KFactor Pt. 11 |
155 |
K-Factor 11. |
156 |
KFactor Pt. 12 |
157 |
K-Factor 12. |
158 |
KFactor Pt. 13 |
159 |
K-Factor 13. |
160 |
KFactor Pt. 14 |
161 |
K-Factor 14. |
162 |
KFactor Pt. 15 |
163 |
K-Factor 15. |
164 |
KFactor Pt. 16 |
165 |
K-Factor 16. |
166 |
KFactor Pt. 17 |
167 |
K-Factor 17. |
168 |
KFactor Pt. 18 |
169 |
K-Factor 18. |
170 |
KFactor Pt. 19 |
171 |
K-Factor 19. |
172 |
KFactor Pt. 20 |
173 |
K-Factor 20. |
174 |
|
175 |
Pulse Scale |
176 |
Set number of total units equal to one pulse. |
177 |
OFF |
178 |
1 |
179 |
10 |
180 |
100 |
181 |
Pulse Frequency |
182 |
Set frequency of burst of pulse out. |
183 |
2 |
184 |
4 |
185 |
8 |
186 |
Alarm 1 Function |
187 |
Select function for Alarm 1. |
188 |
RATE |
189 |
TOTAL |
190 |
Alarm 1 Level |
191 |
Enter Alarm 1 setpoint in selected flow units. |
192 |
5.0f |
193 |
6.1f |
194 |
6.2f |
195 |
6.3f |
196 |
Alarm 2 Function |
197 |
Select function for Alarm 2. |
198 |
Alarm 2 Level |
199 |
Enter Alarm 2 setpoint in selected flow units. |
200 |
invalid_index |
201 |
Alarm 1 Release |
202 |
Unlatch Alarm 1 output. |
203 |
Not Released |
204 |
Released |
205 |
Alarm 2 Release |
206 |
Unlatch Alarm 2 output. |
207 |
Alarm 1 Test |
208 |
Test Alarm 1 output. |
209 |
Alarm Set Low |
210 |
Alarm Set High |
211 |
Alarm 2 Test |
212 |
Test Alarm 2 output. |
213 |
HRT1 Tag |
214 |
Tag number for device. |
215 |
8u |
216 |
Max Sample Time |
217 |
Enter a number between 1 and 80 to increase the amount of time to wait for last sample. |
218 |
2u |
219 |
Password |
220 |
Enter 4-digit password. |
221 |
Change |
222 |
Compare |
223 |
Invalid Password |
224 |
Lock Unit |
225 |
Enable/Disable password protection. |
226 |
NO |
227 |
YES |
228 |
Current Mode |
229 |
Set mode for analog output. |
230 |
Follows rate |
231 |
Set to 4 mA |
232 |
Set to 12 mA |
233 |
Set to 20 mA |
234 |
Clear Total |
235 |
Clear the diplayed flow total. |
236 |
Set Total |
237 |
Write a flow total to the device. |
238 |
Pulse Test |
239 |
Generate 1Hz pulse output test signal. |
240 |
Set Alarm 1 ON |
241 |
Set Alarm 1 output on. |
242 |
Set Alarm 2 ON |
243 |
Change Lock Status |
244 |
TBD |
245 |
Start |
246 |
Process Variables |
247 |
Primary Variables |
248 |
Identification |
249 |
PV Measurement |
250 |
Range Values |
251 |
Measured Values |
252 |
HART Tags |
253 |
Device Info. |
254 |
Revisions |
255 |
PV |
256 |
LRV |
257 |
URV |
258 |
Device Diagnostics |
259 |
Summary |
260 |
Failed |
261 |
Warning |
262 |
Configuration |
263 |
Identity |
264 |
Device Status |
265 |
Test Status |
266 |
Alarm Status |
267 |
Overrange Conditions |
268 |
Configuration Status |
269 |
Device Setup |
270 |
Outputs Setup |
271 |
Meter Setup |
272 |
HART Setup |
273 |
Flow Setup |
274 |
Total Setup |
275 |
Pulse Setup |
276 |
Analog Setup |
277 |
Alarm 1 |
278 |
Alarm 2 |
279 |
KFactor |
280 |
Upload |
281 |
PV Analog Channel Saturated |
282 |
PV Analog Channel Fixed |
283 |
Wireless |
284 |
WirelessHART Device |
285 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
286 |
Primary |
287 |
Primary Analog Channel |
288 |
Secondary |
289 |
Secondary Analog Channel |
290 |
Tertiary |
291 |
Tertiary Analog Channel |
292 |
Quaternary |
293 |
Quaternary Analog Channel |
294 |
Quinary |
295 |
Quinary Analog Channel |
296 |
Critical Power Failure |
297 |
Lock all |
298 |
Trim not supported |
299 |
Configuration cannot be changed |
300 |
Locked by gateway |
301 |
Analog Input Channel |
302 |
Analog Output Channel |
303 |
Secondary Analog Channel Saturated |
304 |
Tertiary Analog Channel Saturated |
305 |
Quaternary Analog Channel Saturated |
306 |
Quinary Analog Channel Saturated |
307 |
Secondary Analog Channel Fixed |
308 |
Tertiary Analog Channel Fixed |
309 |
Quaternary Analog Channel Fixed |
310 |
Quinary Analog Channel Fixed |
311 |
Simulation active |
312 |
The device is in simulation mode and the level output is not representative of the process. |
313 |
Non-Volatile memory failure |
314 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
315 |
Volatile memory error |
316 |
The RAM memory check is invalid or maybe corrupt |
317 |
Watchdog reset executed |
318 |
A watchdog reset has been performed |
319 |
Voltage conditions out of range |
320 |
A voltage condition is outside its allowable range |
321 |
Environmental conditions out of range |
322 |
An internal or environmental condition is beyond acceptable limits. |
323 |
Electronic failure |
324 |
A hardware problem not related to the sensor has been detected. |
325 |
Subdevice list changed |
326 |
Duplicate master detected |
327 |
Capacity Denied |
328 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
329 |
Bandwidth allocation pending |
330 |
Block transfer pending |
331 |
Battery life |
332 |
Percent range |
333 |
Loop current |
334 |
Primary variable |
335 |
Secondary variable |
336 |
Tertiary variable |
337 |
Quaternary variable |
338 |
Read receive time |
339 |
Write date and time |
340 |
Non-Volatile Clock |
341 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
342 |
Clock Uninitialized |
343 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
344 |
None |
345 |
No restrictions |
346 |
SI Only |
347 |
Restricted to SI Unit codes only |
348 |
Process automation device |
349 |
Discrete device |
350 |
Hybrid:Process automation+discrete |
351 |
I/O System |
352 |
WirelessHART Process automation device |
353 |
WirelessHART Discrete device |
354 |
WirelessHART Process automation+discrete |
355 |
WirelessHART Gateway |
356 |
WirelessHART Access point |
357 |
WirelessHART Process adapter |
358 |
WirelessHART Discrete adapter |
359 |
WirelessHART enabled handheld/portable maintenance tool |
360 |
Device Profile |
361 |
US |
362 |
United States of America |
363 |
JP |
364 |
Japan |
365 |
DE |
366 |
Germany |
367 |
FR |
368 |
France |
369 |
ES |
370 |
Spain |
371 |
RU |
372 |
Russian Federation |
373 |
CN |
374 |
People's Republic of China |
375 |
Secondary Master |
376 |
Primary Master |
377 |
Device Diagnostic Status 0 |
378 |
Device Diagnostic Status 1 |
379 |
I/O and Subdevice Status |
380 |
WirelessHART Status |
381 |
Time Set Option |
382 |
Real Time Clock Flags |
383 |
Country |
384 |
Country of intended device installation |
385 |
SI Unit Control |
386 |
Indicates if device should only display SI unit codes |
387 |
Dynamic Variables Returned for Device Variables |
388 |
Command Response Truncated |
389 |
Configuration Change Counter Mismatch |
390 |
Status bytes mismatch |
391 |
8.3f |
392 |
Output Status |
393 |
Output Status Byte |
394 |
Uninitialized |
395 |
Normal - one sensor |
396 |
Normal - two sensors |
397 |
Normal - three sensors |
398 |
Shorted |
399 |
Shorted- shorted field wiring. |
400 |
Limited high |
401 |
Limited high- block can not respond to upward movement of value. |
402 |
Open |
403 |
Open- open field wiring. |
404 |
Limited low |
405 |
Limited low- block can not respond to upward movement of target. |
406 |
Initialization done |
407 |
Initialization done- block initialization is complete. |
408 |
Not selected |
409 |
Not selected- target value provided by block was not selected. |
410 |
No path |
411 |
No path- there is no path to the process. |
412 |
Fail |
413 |
Fail- hardware failure. |
414 |
Bad |
415 |
Bad- block is out of service or has bad input. |
416 |
Not from process |
417 |
Not from process- value is not directly affected by any process information. |
418 |
Local override |
419 |
Local override- block has LO mode. |
420 |
Not Cascade Mode |
421 |
Not RCas Mode |
422 |
Not ROut Mode |
423 |
No communication |
424 |
No communication- (NO_COM). |
425 |
uint16_var_blk_char |
426 |
uint32_var_blk_char |
427 |
uint8_var_blk_char |
428 |
int8_var_blk_char |
429 |
new itest redef1 label |