0 |
Model 705 2.x |
1 |
MAGNETROL |
2 |
Device ID |
3 |
Poll Address |
4 |
Faults |
5 |
Default Paramtrs |
6 |
Default Parameters - Non-volatile memory contents have been overwritten with default values. Please re-enter application parameters through Calibration and Basic Setup menus. |
7 |
No Fiducial |
8 |
No Fiducial Pulse - Check connection between circuit boards in module. |
9 |
No Level Signal |
10 |
Missing Level Signal - Check probe connection and application parameters. |
11 |
Bad Cal Paramtrs |
12 |
Bad Calibration Paramters - Check that the correct probe length has been entered. |
13 |
Fault 3 |
14 |
Available for additional fault identification. |
15 |
Fault 2 |
16 |
reserved |
17 |
Not available for fault identification. |
18 |
Warnings |
19 |
Factory Cal Reqd |
20 |
Factory Calibration required - The module requires re-calibration by the factory. The instrument will continue to operate at reduced accuracy. |
21 |
ICF1 State Error |
22 |
Device in unknown state when input capture interrupt occurred. |
23 |
OCF1 State Error |
24 |
Device in unknown state when output compare interrupt occurred. |
25 |
ICF2 Interrupt |
26 |
Spurious input capture interrupt occurred. |
27 |
OCF2 Interrupt |
28 |
Spurious output compare interrupt occurred. |
29 |
Ovrflw Interrupt |
30 |
Unexpected timer overflow interrupt has occurred. |
31 |
Extern Interrupt |
32 |
Unexpected external interrupt has occurred. |
33 |
Sfwr Interrupt |
34 |
Unexpected software interrupt has occurred. |
35 |
Trim 4 and 20 |
36 |
Loop Test |
37 |
Units |
38 |
6.1f |
39 |
Level of material in vessel |
40 |
5.1f |
41 |
% |
42 |
% Output |
43 |
Minimum Span |
44 |
Upper Range Limit |
45 |
Lower Range Limit |
46 |
4.1f |
47 |
Damping |
48 |
5.2f |
49 |
Loop |
50 |
Analog output loop current |
51 |
Alarms |
52 |
7xA_x |
53 |
7xA: Coaxial Probe (dielectric range >= 1.7) |
54 |
7xB_x |
55 |
7xB: Rigid Twin Rod Probe (dielectric range >= 2.0) |
56 |
7xD_x |
57 |
7xD: High Temperature-High Pressure Coaxial Probe (dielectric range >= 2.0) |
58 |
7xP_x |
59 |
7xP: High Pressure Coaxial Probe (dielectric range >= 1.7) |
60 |
7xR_x |
61 |
7xR: Coaxial Probe for flooding applications (dielectric range >= 1.7) |
62 |
7xS_x |
63 |
7xS: High Temperature-High Pressure Coaxial Probe for steam |
64 |
7xU_x |
65 |
7xU_x: Coaxial Probe for cryogenic liquids (dielectric range >= 1.7) |
66 |
7x7_x |
67 |
7x7: Flexible Twin Rod Probe (dielectric range >= 2.0) |
68 |
Type 9 |
69 |
Type 10 |
70 |
Type 11 |
71 |
Type 12 |
72 |
Type 13 |
73 |
Type 14 |
74 |
Type 15 |
75 |
Type of probe connected to transmitter |
76 |
Probe Type |
77 |
NPT |
78 |
US National tapered Pipe Thread |
79 |
BSP |
80 |
British Straight Pipe Thread |
81 |
Flange |
82 |
Welded ANSI or DIN Flange |
83 |
Mounting style of probe fitting |
84 |
Probe Mount |
85 |
Distance from face of process seal to end of probe |
86 |
Probe Length |
87 |
Probe Offset |
88 |
Desired level reading when liquid surface is at end of probe |
89 |
1.7 - 3 |
90 |
Dielectric constant of material lies between 1.7 and 3 |
91 |
3 - 10 |
92 |
Dielectric constant of material lies between 3 and 10 |
93 |
10 - 100 |
94 |
Dielectric constant of material lies between 10 and 100 |
95 |
1.4 - 1.7 |
96 |
Dielectric constant of material lies between 1.4 and 1.7 |
97 |
Dielectric |
98 |
Dielectric constant of material in vessel |
99 |
4mA Set Point |
100 |
20mA Set Point |
101 |
3.6mA |
102 |
22mA |
103 |
Hold |
104 |
Fault State |
105 |
Date/Time/Initials |
106 |
When and by whom calibration was performed |
107 |
3u |
108 |
Enter Password |
109 |
Password is required for adjusting Advanced Setup parameters Magnetrol S/N and Device id, and Factory Settings parameters Window, Range, Gain, Conversion Factor, Scale Offset, and Target Calibration for 7xS Probe. |
110 |
Magnetrol S/N |
111 |
Factory parameter, displayed for diagnostic purposes only |
112 |
8u |
113 |
New User Password |
114 |
User password required to change parameter settings from keypad |
115 |
4u |
116 |
Ticks |
117 |
Fiducial Ticks |
118 |
<Window> |
119 |
Range |
120 |
Gain |
121 |
Conversion Factor |
122 |
4i |
123 |
Scale Offset |
124 |
5d |
125 |
7xS Derating Fct |
126 |
Run |
127 |
Cal |
128 |
7xS Oper Mode |
129 |
7xS Target Ticks |
130 |
7xS Target Ratio |
131 |
7xS Target Gain |
132 |
7xS Targ Cal Tks |
133 |
CFD |
134 |
Fixed |
135 |
Threshold |
136 |
Use 'CFD' except in situation with low dielectric (< 3) material over higher dielectric (> 10) material, e.g., oil over water, in which case use 'Fixed'. |
137 |
# of Ticks |
138 |
Damped time of flight. Factory parameter, displayed for diagnostic purposes only |
139 |
4mA Trim Value |
140 |
20mA Trim Value |
141 |
Firmware Version |
142 |
Main Menu |
143 |
Device Setup |
144 |
Basic Setup |
145 |
Advanced Setup |
146 |
Diagnostics |
147 |
Factory Settings |
148 |
Review |
149 |
7xS Target Calib |
150 |
Captures time-of-flight to target on 7xS probe at room ambient. |
151 |
Targ Cal Abort |
152 |
No Target detected and/or Probe not dry |
153 |
Elapsed Time |
154 |
04d |
155 |
sec(-ive) hrs(+ive) |
156 |
Elapsed time since most recent significant event. |
157 |
Event status |
158 |
ALL FAULTS CLEARED |
159 |
POWER ON |
160 |
DEFAULT PARAMETERS |
161 |
BAD CAL PARAMETERS |
162 |
DEFAULT PARAMETERS++ |
163 |
NO LEVEL SIGNAL |
164 |
NO LEVEL SIGNAL++ |
165 |
NO FIDUCIAL SIGNAL |
166 |
DEFAULT PARAMETERS+ |
167 |
NO FIDUCIAL SIGNAL+ |
168 |
NO FIDUCIAL SIGNAL++ |
169 |
DEFAULT PARAMTERS+++ |
170 |
Bit encoded event status stored in log. |
171 |
Event Interval |
172 |
05i |
173 |
Interval associated with a particular event that is the time elapsed since the previous event. |
174 |
No earlier event |
175 |
No later event |
176 |
Display Event Log |
177 |
Displays history of significant events such as Power On, Faults, and All Faults Cleared. The time interval displayed with a particular event is the time elapsed since the previous event. The interval associated with a Power On event is always 0. |
178 |
|
179 |
% Out |
180 |
|
181 |
FMU860 |
182 |
DT |
183 |
DVC |
184 |
FCX |
185 |
AS800 |
186 |
340T |
187 |
340C |
188 |
344 |
189 |
Siemens Micro K |
190 |
SITRANS L |
191 |
SIPAN PH |
192 |
SITRANS P |
193 |
75SMT |
194 |
UNIDELTA |
195 |
8320 |
196 |
SX5100 |
197 |
TSV175 |
198 |
DMU |
199 |
3780 |
200 |
BM70 |
201 |
Target Ticks =%[4i]{0} |
202 |
Calibration ok
Set Targ Air =%[4i]{0}? |
203 |
Calibration bad
TargTks unstable |
204 |
Interval since most recent event:
%[.4d]{fault_status_age} secs |
205 |
Interval since most recent event:
%[.4d]{fault_status_age} hrs |
206 |
Event log empty |
207 |
Event:
%{0}
Interval:
%[.4d]{interval_secs} secs |
208 |
Get earlier event;Get later event |
209 |
Event:
%{0}
Interval:
%[.4d]{1} hrs |