0 |
B3HU2 - HART 7 |
1 |
M-System Co., LTD. |
2 |
Hardware Error |
3 |
EEPROM Error |
4 |
Flash ROM Error |
5 |
ADC Error |
6 |
Sensor Error |
7 |
PV Out of Range |
8 |
Sensor 1 Burnout |
9 |
Sensor 2 Burnout |
10 |
CJC Broken |
11 |
Additional Device Status 2 |
12 |
Reserved 0 |
13 |
Reserved 1 |
14 |
Reserved 2 |
15 |
Reserved 3 |
16 |
Reserved 4 |
17 |
Reserved 5 |
18 |
Reserved 6 |
19 |
Reserved 7 |
20 |
Additional Device Status 3 |
21 |
Additional Device Status 4 |
22 |
Additional Device Status 5 |
23 |
Maintenance Required |
24 |
Device Variable Alert |
25 |
Misc. |
26 |
EEPROM or Flash ROM Error |
27 |
Write Protection Mode |
28 |
Update Period |
29 |
Update period for burst message |
30 |
Max Update Period |
31 |
Maxium update period for burst message |
32 |
Burst Command |
33 |
Burst Msg Trigger Mode |
34 |
Burst Trigger Mode Selection |
35 |
Burst Trigger Class |
36 |
Device Variable Classfication for Trigger Level |
37 |
Burst Trigger Units |
38 |
Unit of Trigger Level |
39 |
Burst Trigger Level |
40 |
Trigger Level Value |
41 |
Wired HART Enabled |
42 |
Enabled on Wired HART device connection only |
43 |
Burst Variable Code |
44 |
Burst Variable Slot - Device variable code assigned to the slot to be read in burst mode. |
45 |
Snsr PV |
46 |
Device Variable 0 |
47 |
Snsr 1 |
48 |
Device Variable 1 |
49 |
Snsr 2 |
50 |
Device Variable 2 |
51 |
Snsr CJC |
52 |
Device Variable 3 |
53 |
Percent Range |
54 |
Percent Value of PV (%) |
55 |
Loop Current |
56 |
Analog Output Value (mA) |
57 |
PV |
58 |
Primary Variable |
59 |
SV |
60 |
Secondary Variable |
61 |
TV |
62 |
Tertiary Variable |
63 |
QV |
64 |
Quatemary Variable |
65 |
Not Used |
66 |
Process Value |
67 |
Field Device Variable Value |
68 |
.3f |
69 |
PV fmly |
70 |
PV Class |
71 |
PV PDQ |
72 |
PV LS |
73 |
PV Fmly stat |
74 |
PV USL |
75 |
Upper PV Limit Value |
76 |
PV LSL |
77 |
Lower PV Limit Value |
78 |
PV min span |
79 |
Minimum Span Value |
80 |
PV damp |
81 |
Damping Value |
82 |
8.3f |
83 |
PV Update Period |
84 |
|
85 |
s |
86 |
PV snsr s/n |
87 |
7d |
88 |
PV Lower trim |
89 |
PV Upper trim |
90 |
PV Trim support |
91 |
PV Min lower trim |
92 |
PV Max lower trim |
93 |
PV Min upper trim |
94 |
PV Max upper trim |
95 |
PV Min trim diff |
96 |
PV Simulate |
97 |
Simulate |
98 |
Snsr1 Class |
99 |
Snsr2 Class |
100 |
Temp Class |
101 |
Snsr1 PDQ |
102 |
Snsr2 PDQ |
103 |
CJC PDQ |
104 |
Snsr1 LS |
105 |
Snsr2 LS |
106 |
CJC LS |
107 |
Snsr1 Dev Stat |
108 |
Snsr2 Dev Stat |
109 |
CJC Dev Stat |
110 |
Snsr1 USL |
111 |
Snsr2 USL |
112 |
CJC USL |
113 |
Snsr1 LSL |
114 |
Snsr2 LSL |
115 |
CJC LSL |
116 |
Snsr1 min span |
117 |
Snsr2 min span |
118 |
CJC min span |
119 |
Snsr1 damping |
120 |
Snsr2 damping |
121 |
CJC damping |
122 |
Snsr1 Update Period |
123 |
Snsr2 Update Period |
124 |
CJC Update Period |
125 |
Snsr1 snsr s/n |
126 |
CJC snsr s/n |
127 |
Snsr1 Simulate |
128 |
Snsr2 Simulate |
129 |
CJC Simulate |
130 |
Secondary Variable - Temperature Compensation |
131 |
Zero X |
132 |
Zero Y |
133 |
Gain |
134 |
PV Snsr |
135 |
CJC Snsr |
136 |
PV Sensor type |
137 |
Ohms |
138 |
Ohms - Resistance meter |
139 |
RTD_CVD |
140 |
RTD_CVD - Calibrated(Callender_Van_Dusen) RTD |
141 |
Pt 100 |
142 |
Pt 100 - IEC751 a = 0.003850 |
143 |
Pt 500 |
144 |
Pt 500 - IEC751 a = 0.003850 |
145 |
Pt 1000 |
146 |
Pt 1000 - IEC751 a = 0.003850 |
147 |
jPt 100 JIS89 |
148 |
jPt 100 - a=0.003916 (JIS C 1604-89 , SAMA RC21-4-1966) |
149 |
RTD_Spec |
150 |
RTD_Spec - Custom defined RTD |
151 |
Millivolt |
152 |
Millivolt- Milli-Volts |
153 |
TC B |
154 |
TC B - IEC 584 etc. (Pt30Rh-Pt6Rh) |
155 |
TC C |
156 |
TC C - Omega type C, TC Type W5, ASTM E 988 (W5-W26Rh) |
157 |
TC D |
158 |
TC D - Omega type D, TC Type W3, ASTM E 988 (W3-W25Rh) |
159 |
TC E |
160 |
TC E - IEC 584 etc. (Ni10Cr-Cu45Ni) |
161 |
TC J |
162 |
TC J - IEC 584 etc. (Fe-Cu45Ni) |
163 |
TC K |
164 |
TC K - IEC 584 etc. (Ni10Cr-Ni5) |
165 |
TC N |
166 |
TC N - IEC 584 etc. (Ni14CrSi-NiSi) |
167 |
TC R |
168 |
TC R - IEC 584 etc. (Pt13Rh-Pt) |
169 |
TC S |
170 |
TC S - IEC 584 etc. (Pt10Rh-Pt) |
171 |
TC T |
172 |
TC T - IEC 584 etc. (Cu-Cu45Ni) |
173 |
TC L |
174 |
TC L - DIN 43710 (Fe-CuNi) |
175 |
TC U |
176 |
TC U - DIN 43710 (Cu-CuNi) |
177 |
TC Spec |
178 |
TC Spec - Custom defined TC |
179 |
PV Sensor Wire Type |
180 |
PV Sensor Measurement Type |
181 |
Single |
182 |
Input signal is single |
183 |
Average |
184 |
Input value is average of sensor 1 and 2 |
185 |
Backup |
186 |
Input signal is value of correct sensor |
187 |
Differential |
188 |
Input signal is defferential value between sensor1 and sensor2 |
189 |
CJC Mode |
190 |
CJC Mode - Cold Junction Compensation Mode which becomes effective at Thermcouple input |
191 |
Cold Junction Compensation is OFF |
192 |
Cold Junction Compensation is ON |
193 |
Broken Detect |
194 |
Broken Detect - Whether or not a/the sensor is opened is detected by pouring a slight current at the wire broken detect mode ON |
195 |
Wire Broken Detection is OFF |
196 |
Wire Broken Detection is ON |
197 |
Satu. Hi |
198 |
Saturation high value - The high saturation value must be between 20.0 and 21.5 mA. |
199 |
mA |
200 |
Satu. Lo |
201 |
Saturation low value - The low saturation value must be between 3.8 and 4.0 mA. |
202 |
Burnout AO |
203 |
When the input signal wiring is detected open, the Analog output is set Alarm Value. Alarm Value X is 3.75<=x<=3.8 or 21.5<=x<= 23.0. |
204 |
A |
205 |
A - Coefficient A(=3.908E-3 at Pt100) of Callendar-Van Dusen Coefficients The Callendar-Van Dusen equation is Rt = R0 * ( 1 + A*T + B*T^2 -100*C*T^3 + C*T^4 ) |
206 |
.6e |
207 |
16.6e |
208 |
B |
209 |
B - Coefficient B(=-5.775E-7 at Pt100) of Callendar-Van Dusen Coefficients The Callendar-Van Dusen equation is Rt = R0 * ( 1 + A*T + B*T^2 -100*C*T^3 + C*T^4 ) |
210 |
C |
211 |
C - Coefficient C(=-4.183E-12 at Pt100) of Callendar-Van Dusen Coefficients The Callendar-Van Dusen equation is Rt = R0 * ( 1 + A*T + B*T^2 -100*C*T^3 + C*T^4 ) |
212 |
R0 |
213 |
R0 - Coefficient R0(=100.0 at Pt100) of Callendar-Van Dusen Coefficients The Callendar-Van Dusen equation is Rt = R0 * ( 1 + A*T + B*T^2 -100*C*T^3 + C*T^4 ) |
214 |
LL |
215 |
Lower Limit - The Lower Limit temperature value that be measured with the sensor |
216 |
UL |
217 |
Upper Limit - The Upper Limit temperature value that be measured with the sensor |
218 |
Cal. Snsr |
219 |
Calibration Sensor number - The sensor 1 or 2 must be selected at calibrating the sensor |
220 |
Sensor 1 |
221 |
Sensor 2 |
222 |
Cal. Mode |
223 |
Input Sensor Calibration Mode |
224 |
Reset |
225 |
Zero Cal. |
226 |
Span Cal. |
227 |
.5f |
228 |
10.5f |
229 |
Sn |
230 |
Sensor 1 or 2 value - Digital value of the sensor 1 or 2 with the same engineering unit of PV |
231 |
.4f |
232 |
Snsr1 Zero X |
233 |
Sensor 1 calibrated X value of Zero Calibration |
234 |
Snsr1 Zero Y |
235 |
Sensor 1 calibrated Y value of Zero Calibration |
236 |
Snsr1 Gain |
237 |
Sensor 1 calibrated value of Gain Calibration |
238 |
.6f |
239 |
Snsr2 Zero X |
240 |
Sensor 2 calibrated X value of Zero Calibration |
241 |
Snsr2 Zero Y |
242 |
Sensor 2 calibrated Y value of Zero Calibration |
243 |
Snsr2 Gain |
244 |
Sensor 2 calibrated value of Gain Calibration |
245 |
Re-range |
246 |
Sensor Calibration |
247 |
Sensors |
248 |
PV Sensor |
249 |
CJC Temperature sensor |
250 |
Calibrated RTD |
251 |
Burst Configuration |
252 |
Burst Message 1 |
253 |
Burst Variables 1 |
254 |
Sensor Connection |
255 |
Select Snsr |
256 |
Snsr Zero Cal. |
257 |
Snsr Zero Cal.- Make the sensor input the new input reference. |
258 |
Snsr Span Cal. |
259 |
Snsr Span Cal. - Make the sensor input the new input reference. |
260 |
Reset Cal. |
261 |
Reset Cal.- Reset the all sensor input calibration data. |
262 |
Select Cal. Snsr |
263 |
Select Calibration sensor number |
264 |
reset more sts available flag |
265 |
Reset More Status Available Flag |
266 |
reset cfg chng flag |
267 |
Reset Configuration Change Flag |
268 |
Common Tables |
269 |
Interoperable * |
270 |
Universal |
271 |
Common Practice |
272 |
Pressure Universal |
273 |
Pressure Common |
274 |
Menu |
275 |
Rosemount Magflow |
276 |
Rosemount Pressure |
277 |
Moore Products |
278 |
Siemens Pressure |
279 |
P2 Common |
280 |
Wireless |
281 |
Munge |
282 |
Analytical Oxygen/Combustion/Methane/CO |
283 |
Flow Totalizer - Rate Indicator |
284 |
Flow Variable Area |
285 |
Flow Coriolis Mass |
286 |
Flow Ultrasonic - Gas |
287 |
Flow Ultrasonic - Liquid |
288 |
Level Ultrasonic |
289 |
Level Radar - Microwave |
290 |
Pressure Absolute |
291 |
Level Capacitance |
292 |
Pressure Differential |
293 |
Level Hydrostatic |
294 |
Level |
295 |
Pressure Absolute/Relative |
296 |
Level Microwave |
297 |
Level Radar |
298 |
Level Density - Nuclear |
299 |
Flow Electromagnetic |
300 |
Flow Vortex |
301 |
Flow Magmeter - Rack Version |
302 |
Flow High Performance Magmeter |
303 |
Flow Mass |
304 |
Flow Ultrasonic |
305 |
Flow Magnetic |
306 |
Flow Magnetic - Custody Transfer |
307 |
Flow 2-wire Magnetic |
308 |
Flow Coriolis Mass - Custody Transfer |
309 |
Flow 2-wire Vortex |
310 |
Flow Thermal |
311 |
Temperature Head Mounted |
312 |
Temperature Compact |
313 |
Temperature DIN Rail Mounted |
314 |
Analytical pH |
315 |
Analytical Conductivity - Conductive |
316 |
Analytical Conductivity - Inductive |
317 |
Temperature Sensor |
318 |
Level Servo |
319 |
Temperature DIN Rail |
320 |
Temperature |
321 |
Analytical ORP |
322 |
Analytical pION |
323 |
Analytical IConc |
324 |
Analytical Electrode Conductivity |
325 |
Analytical Toroidal Conductivity |
326 |
Valve Positioner |
327 |
Valve Controller |
328 |
Pressure |
329 |
Pressure Multivariable |
330 |
Analytical pH/ORP |
331 |
Flow Coriolis |
332 |
Analytical Conductivity |
333 |
Valve Positioner/Pneumatic |
334 |
Valve Actuator - Electrical |
335 |
Temperature Dual Input |
336 |
Valve Actuator |
337 |
Analytical Corrosion |
338 |
Analytical Density - Nuclear |
339 |
Level Continuous Gamma |
340 |
Level Laser Ranging |
341 |
Pressure Safety |
342 |
Flow Vortex/Swirl |
343 |
Flow |
344 |
Analytical 4 Electrode Conductivity |
345 |
Analytical 2 Electrode Conductivity |
346 |
Analytical Troidal Conductivity |
347 |
Analytical pH/ORP/pIon/Ion Conc |
348 |
Analytical Oxygen |
349 |
Pressure P, dP + Multivariable |
350 |
Temperature 2-wire |
351 |
Pressure w/ PID |
352 |
Pressure Saturated Steam |
353 |
Analytical Density - Gamma Ray |
354 |
Level Gamma Ray |
355 |
Analytical Weight - Gamma Ray |
356 |
Level w/ Density - Gamma Ray |
357 |
Analytical Motorized Density |
358 |
Flow Multivariable Mass |
359 |
Temperature Multivariable |
360 |
Specialty HART-to-Analog Signal Conv |
361 |
Flow dP |
362 |
Pressure Low Power |
363 |
Pressure Certified SIL2 |
364 |
Interoperable |
365 |
Analytical Density |
366 |
Valve Positioner/Electropneumatic |
367 |
Flow Magnetic Inductive |
368 |
Analytical |
369 |
Analytical Opacity Monitor |
370 |
Analytical Oxygen/Combustion |
371 |
Analytical 2-wire Conductivity |
372 |
Analytical 2-wire Conductivity w/ pure H20 |
373 |
Analytical 2-wire Conductivity w/ % conc |
374 |
Analytical 2-wire Oxygen/Chlorine/Ozone |
375 |
Analytical 2-wire pH/ORP |
376 |
Analytical 2-wire Contacting/Toroidal |
377 |
Analytical Oxygen - High Temperature |
378 |
Analytical Conductivity w/ % conc |
379 |
Analytical pH/ORP/ISE |
380 |
Analytical Amperometric Analyzer |
381 |
Analytical Dual Input Analyzer |
382 |
Pressure Pressure/Level |
383 |
Analytical Consistency |
384 |
Analytical Microwave-Pulp Consistency |
385 |
Analytical Microwave Consistency |
386 |
Valve Digital Positioner |
387 |
Valve Smart Valve Positioner |
388 |
Temperature Differential |
389 |
Analytical Dissolved Oxygen |
390 |
Analytical pH Controller |
391 |
Analytical Conductivity/Resistivity Controller |
392 |
Analytical Conductivity/Resistivity |
393 |
Level Displacement |
394 |
Temperature w/ PID |
395 |
Valve Universal Positioner |
396 |
Level Radar - Reflex |
397 |
Pressure Gauge |
398 |
Pressure Sealed Gauge |
399 |
Valve Digital Positioner w/ PID |
400 |
Valve Intelligent Positioner |
401 |
Analytical Gas Detector |
402 |
Analytical Infrared Gas Detector |
403 |
Analytical Electrochemical Gas Detector |
404 |
Analytical Measuring Instruments |
405 |
Level Magnostrictive |
406 |
Valve On/Off Valve Controller |
407 |
Level Radar - Pulse |
408 |
Level Continuous Capactive |
409 |
Valve Damper Actuator |
410 |
Valve Electric Damper Actuator |
411 |
Flow Electronic |
412 |
Flow Vortex - Multiparameter Mass |
413 |
Analytical UV Flame Detector |
414 |
Analytical UVIR Flame Detector |
415 |
Analytical IR Flame Detector |
416 |
Analytical Fire Detector |
417 |
Analytical Gas Detector Display Interface |
418 |
Analytical Toxic Gas Detector |
419 |
Analytical Flame Detector |
420 |
Level Nuclear |
421 |
Analytical Microwave |
422 |
Analytical Density - Radiometric |
423 |
Level Radiometric |
424 |
Analytical Gas/Steam |
425 |
Level Nucleonic |
426 |
Analytical Blade Consistency |
427 |
Analytical Rotary Consistency |
428 |
Pressure Absolute/Differential |
429 |
Positioner |
430 |
Analytical Combustible Gas Detector |
431 |
Analytical Point Infrared Gas Detector |
432 |
Analytical Multi-Detector Monitor System |
433 |
Valve Positioner/Electro-hydraulic |
434 |
Valve Monitor |
435 |
Enable on token-passing data link layer only |
436 |
Enable on TDMA data link layer only |
437 |
Enable on both TDMA and token-passing data link layer |
438 |
WirelessHART Device |
439 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
440 |
Primary |
441 |
Primary Analog Channel |
442 |
Secondary |
443 |
Secondary Analog Channel |
444 |
Tertiary |
445 |
Tertiary Analog Channel |
446 |
Quaternary |
447 |
Quaternary Analog Channel |
448 |
Quinary |
449 |
Quinary Analog Channel |
450 |
Critical Power Failure |
451 |
Lock all |
452 |
Trim not supported |
453 |
Configuration cannot be changed |
454 |
Locked by gateway |
455 |
Analog Input Channel |
456 |
Analog Output Channel |
457 |
Secondary Analog Channel Saturated |
458 |
Tertiary Analog Channel Saturated |
459 |
Quaternary Analog Channel Saturated |
460 |
Quinary Analog Channel Saturated |
461 |
Secondary Analog Channel Fixed |
462 |
Tertiary Analog Channel Fixed |
463 |
Quaternary Analog Channel Fixed |
464 |
Quinary Analog Channel Fixed |
465 |
Simulation active |
466 |
The device is in simulation mode and the level output is not representative of the process. |
467 |
Non-Volatile memory failure |
468 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
469 |
Volatile memory error |
470 |
The RAM memory check is invalid or maybe corrupt |
471 |
Watchdog reset executed |
472 |
A watchdog reset has been performed |
473 |
Voltage conditions out of range |
474 |
A voltage condition is outside its allowable range |
475 |
Environmental conditions out of range |
476 |
An internal or environmental condition is beyond acceptable limits. |
477 |
Electronic failure |
478 |
A hardware problem not related to the sensor has been detected. |
479 |
Subdevice list changed |
480 |
Duplicate master detected |
481 |
Capacity Denied |
482 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
483 |
Bandwidth allocation pending |
484 |
Block transfer pending |
485 |
Continuous |
486 |
The Burst Message is published continuously at (worst case) the Minimum Update Period. |
487 |
Window |
488 |
The Burst Message is triggered when the source value deviates more than the specified trigger value |
489 |
Rising |
490 |
The Burst Message is triggered when source value Rises Above the specified trigger value. |
491 |
Falling |
492 |
The Burst Message is triggered when the source value Falls Below the specified trigger value. |
493 |
On-change |
494 |
The Burst Message is triggered when any value in the message changes. |
495 |
Battery life |
496 |
Percent range |
497 |
Loop current |
498 |
Primary variable |
499 |
Secondary variable |
500 |
Tertiary variable |
501 |
Quaternary variable |
502 |
Off |
503 |
Enable event notification on token-passing data link layer |
504 |
Enable event notification on TDMA data link layer |
505 |
Enable event notification on TDMA and token-passing data link layer |
506 |
Configuration changed event pending |
507 |
Device status event pending |
508 |
More status available event pending |
509 |
Disable |
510 |
Enable single data point trending |
511 |
Enable filtered trending |
512 |
The sample is filtered using a time constant equal to one-third the trend sample period |
513 |
Enable average trending |
514 |
The value obtained by dividing the sum of all samples in the period by the total number of samples |
515 |
Read receive time |
516 |
Write date and time |
517 |
Non-Volatile Clock |
518 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
519 |
Clock Uninitialized |
520 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
521 |
Line Power |
522 |
Device is powered via a hardwired connection to a plant power source. |
523 |
Battery Power |
524 |
Device operates solely of its (internal) battery. |
525 |
Recharg.B./Power Sc. |
526 |
Rechargeable battery power or power scavenging. The device has a short-term supply of energy (must be at least one hour) that is continuously being replenished. The device's power is being replenished by harvesting and converting energy from the environment surrounding the device (e.g. solar, vibration, heat). |
527 |
Idle |
528 |
Active search |
529 |
Looking for neighbors. |
530 |
Negotiating |
531 |
Quarantined |
532 |
Operational |
533 |
Suspended |
534 |
Deep sleep |
535 |
Ultra-low power |
536 |
Wireless Signal Found |
537 |
Network packets have been recognized |
538 |
Wireless Signal Identified |
539 |
Wireless Time Synchronized |
540 |
WirelessHart Signal Identified |
541 |
Network Admission Requested |
542 |
Set on transmission of first join request |
543 |
Join Retrying |
544 |
Set after the first join request retry (i.e. when number of join requests > 2). Cleared when device is authenticated or when Active Search started. |
545 |
Join Failed |
546 |
Set on transition from Active Search mode to Deep Sleep mode. Cleared on transition from Deep Sleep to Active Search. |
547 |
Network Security Clearance Granted |
548 |
Network Manager Session Established |
549 |
Network Joined |
550 |
Network Joined. Normal superframe and links obtained. |
551 |
Network Bandwidth Requested |
552 |
Negotiating Network Properties. Gateway session obtained. |
553 |
Join Complete |
554 |
Normal operating mode. |
555 |
None |
556 |
No restrictions |
557 |
SI Only |
558 |
Restricted to SI Unit codes only |
559 |
Open - accept all devices |
560 |
Use Whitelist for access |
561 |
Use Blacklist |
562 |
Use Whitelist and Blacklist |
563 |
Lockdown - disable join links |
564 |
Process automation device |
565 |
Discrete device |
566 |
Hybrid:Process automation+discrete |
567 |
I/O System |
568 |
WirelessHART Process automation device |
569 |
WirelessHART Discrete device |
570 |
WirelessHART Process automation+discrete |
571 |
WirelessHART Gateway |
572 |
WirelessHART Access point |
573 |
WirelessHART Process adapter |
574 |
WirelessHART Discrete adapter |
575 |
WirelessHART enabled handheld/portable maintenance tool |
576 |
Don't attempt to join |
577 |
Join now |
578 |
Attempt to join immediately on powerup or reset |
579 |
US |
580 |
United States of America |
581 |
JP |
582 |
Japan |
583 |
DE |
584 |
Germany |
585 |
FR |
586 |
France |
587 |
ES |
588 |
Spain |
589 |
RU |
590 |
Russian Federation |
591 |
CN |
592 |
People's Republic of China |
593 |
Nominal |
594 |
Device Power Status is nominal |
595 |
Low |
596 |
Device Power Status is low |
597 |
Critically Low |
598 |
Device Power Status is critically low |
599 |
Recharging - Low |
600 |
Recharging - High |
601 |
Secondary Master |
602 |
Primary Master |
603 |
PV Analog Channel Saturated |
604 |
PV Analog Channel Fixed |
605 |
Device Profile |
606 |
Device Diagnostic Status 0 |
607 |
Device Diagnostic Status 1 |
608 |
I/O and Subdevice Status |
609 |
WirelessHART Status |
610 |
Time Set Option |
611 |
Real Time Clock Flags |
612 |
Country |
613 |
Country of intended device installation |
614 |
SI Unit Control |
615 |
Indicates if device should only display SI unit codes |
616 |
Wireless HART Enabled |
617 |
Enabled on WirelessHART device connection only |
618 |
Both Wired and WirelessHart Enabled |
619 |
Enabled on both Wired and WirelessHART connections |
620 |
Event Status |
621 |
Event Notification Control |
622 |
Operate mode Mask |
623 |
Not Defined |
624 |
Power Source |
625 |
Power source of the device |
626 |
Wireless Mode |
627 |
Join Status |
628 |
The current location in the joining sequence of operations. |
629 |
Network Access Mode |
630 |
Join Mode |
631 |
Power Status |
632 |
Power status of the device |
633 |
Master Mode |
634 |
This sets the I/O System's Data Link Layer operation on all channels as either primary or secondary master mode. |
635 |
Trend Units |
636 |
Trend Device Variable Unit Code |
637 |
Trend Classification |
638 |
Trend Device Variable Classification |
639 |
Trend Control |
640 |
uint16_var_blk_char |
641 |
uint8_var_blk_char |
642 |
Device Status Mask |
643 |
Ext dev status Mask |
644 |
Device Diagnostic Status 0 Mask |
645 |
Device Diagnostic Status 1 Mask |
646 |
Device Diagnostic Status 2 Mask |
647 |
Device Diagnostic Status 3 Mask |
648 |
AO saturated Mask |
649 |
AO fixed Mask |
650 |
Latched Device Status |
651 |
Latched Ext dev status |
652 |
Latched Operate Mode |
653 |
Latched Device Diagnostic Status 0 |
654 |
Latched Device Diagnostic Status 1 |
655 |
Latched Device Diagnostic Status 2 |
656 |
Latched Device Diagnostic Status 3 |
657 |
Latched AO saturated |
658 |
Latched AO fixed |
659 |
Wireless Module Device Type |
660 |
Device type of the Wireless Radio |
661 |
Wireless Module Manufacturer ID |
662 |
Manufacturer of the Wireless Radio contained in this device |
663 |
Subdevice Device Type |
664 |
Device type of the subdevice attached to this system. |
665 |
Subdevice Manufacturer Id |
666 |
Manufacturer of the subdevice attached to this system. |
667 |
8u |
668 |
Dynamic Variables Returned for Device Variables |
669 |
Command Response Truncated |
670 |
Configuration Change Counter Mismatch |
671 |
Status bytes mismatch |
672 |
Update time adjusted |
673 |
Invalid burst message |
674 |
Invalid device variable classification |
675 |
Invalid burst trigger mode selection code |
676 |
Burst condition conflict |
677 |
Update period increased |
678 |
Insufficient bandwidth |
679 |
Device Variable |
680 |
Burst var 5 is |
681 |
Burst Variable Slot 5- Device variable code assigned to slot 5 to be read in burst mode. |
682 |
Burst var 6 is |
683 |
Burst Variable Slot 6- Device variable code assigned to slot 6 to be read in burst mode. |
684 |
Burst var 7 is |
685 |
Burst Variable Slot 7- Device variable code assigned to slot 7 to be read in burst mode. |
686 |
Burst var 8 is |
687 |
Burst Variable Slot 8- Device variable code assigned to slot 8 to be read in burst mode. |
688 |
Total Burst Msgs |
689 |
Total number of burst messages supported by this device |
690 |
Cmd 48: Read Additional Device Status |
691 |
Read Additional Device - This command reads additional device status information |
692 |
Output Status |
693 |
Output Status Byte |
694 |
Uninitialized |
695 |
Normal - one sensor |
696 |
Normal - two sensors |
697 |
Normal - three sensors |
698 |
Shorted |
699 |
Shorted- shorted field wiring. |
700 |
Limited high |
701 |
Limited high- block can not respond to upward movement of value. |
702 |
Open |
703 |
Open- open field wiring. |
704 |
Limited low |
705 |
Limited low- block can not respond to upward movement of target. |
706 |
Initialization done |
707 |
Initialization done- block initialization is complete. |
708 |
Not selected |
709 |
Not selected- target value provided by block was not selected. |
710 |
No path |
711 |
No path- there is no path to the process. |
712 |
Fail |
713 |
Fail- hardware failure. |
714 |
Bad |
715 |
Bad- block is out of service or has bad input. |
716 |
Not from process |
717 |
Not from process- value is not directly affected by any process information. |
718 |
Local override |
719 |
Local override- block has LO mode. |
720 |
Not Cascade Mode |
721 |
Not RCas Mode |
722 |
Not ROut Mode |
723 |
No communication |
724 |
No communication- (NO_COM). |
725 |
uint32_var_blk_char |
726 |
int8_var_blk_char |
727 |
new itest redef1 label |