0 |
Device certification |
1 |
Certification of the device. |
2 |
Main announcement |
3 |
Pressure |
4 |
Deg C |
5 |
Deg F |
6 |
% |
7 |
mA |
8 |
PV out of limit |
9 |
Non-PV out of limit |
10 |
Output saturated |
11 |
Output current fixed |
12 |
More status available |
13 |
Cold start flag set |
14 |
Cfg changed flag set |
15 |
Device malfunction |
16 |
Sensor module fault |
17 |
All other bits undef |
18 |
Snsr adc reg faulty |
19 |
Snsr statusblk faulty |
20 |
Snsr serviceblk faulty |
21 |
Snsr s/n faulty |
22 |
Basic module fault |
23 |
All other bits undef |
24 |
BM watchdog faulty |
25 |
BM s/n unknown |
26 |
BM serviceblk faulty |
27 |
New sensor found |
28 |
PvMinMaxUnit |
29 |
psi |
30 |
Pounds Per Square Inch |
31 |
bar |
32 |
Bars |
33 |
kg_Sqcm |
34 |
Kilograms per square centimeter |
35 |
kPa |
36 |
Kilopascals |
37 |
MPa |
38 |
Megapascals |
39 |
mH2O (20°C) |
40 |
Meters of water at 20 degrees Celsius |
41 |
mbar |
42 |
Millibars |
43 |
mmH2O |
44 |
Millimeters of water at 68 Degrees Fahrenheit |
45 |
lbl_reset_auswahl |
46 |
no reset |
47 |
1 - clear min |
48 |
2 - clear max |
49 |
3 - clear min and max |
50 |
no reset |
51 |
1 - clear min |
52 |
2 - clear max |
53 |
3 - clear min and max |
54 |
Pressure value min |
55 |
.0f |
56 |
.1f |
57 |
.2f |
58 |
.3f |
59 |
.4f |
60 |
Pressure value max |
61 |
Temp value max |
62 |
Temp value min |
63 |
Lower trim point |
64 |
Applied process pressure at which the last low sensor trim was performed. |
65 |
Upper trim point |
66 |
Applied process pressure at which the last upper sensor trim was performed. |
67 |
Sw module present |
68 |
Yes |
69 |
No |
70 |
LCD module present |
71 |
Shows if the device has a display mounted |
72 |
HART mod present |
73 |
Channel |
74 |
Channel 1 |
75 |
Channel 2 |
76 |
Channel unit |
77 |
Setpoint 1 |
78 |
Setpoint 2 |
79 |
Hysteresis 1 |
80 |
Hysteresis 2 |
81 |
Switch model 1 |
82 |
Maker |
83 |
Breaker |
84 |
Switch model 2 |
85 |
Hysteresis attitude 1 |
86 |
Low |
87 |
High |
88 |
Hysteresis attitude 2 |
89 |
Switch contact 1 |
90 |
opened |
91 |
closed |
92 |
Switch contact 2 |
93 |
LCD keys blocked |
94 |
If communication fails for a time greater then 30 sec, local operation will be enabled automatically. |
95 |
Device serial number |
96 |
Order number |
97 |
Change counter |
98 |
Number of points |
99 |
2 |
100 |
3 |
101 |
4 |
102 |
5 |
103 |
6 |
104 |
7 |
105 |
8 |
106 |
9 |
107 |
10 |
108 |
11 |
109 |
12 |
110 |
13 |
111 |
14 |
112 |
15 |
113 |
16 |
114 |
17 |
115 |
18 |
116 |
19 |
117 |
20 |
118 |
21 |
119 |
22 |
120 |
23 |
121 |
24 |
122 |
25 |
123 |
26 |
124 |
27 |
125 |
28 |
126 |
29 |
127 |
30 |
128 |
31 |
129 |
method_post_edit_write_tab_Couple |
130 |
Percent value 1 |
131 |
% |
132 |
Percent value 2 |
133 |
Percent value 3 |
134 |
Percent value 4 |
135 |
Percent value 5 |
136 |
Percent value 6 |
137 |
Percent value 7 |
138 |
Percent value 8 |
139 |
Percent value 9 |
140 |
Percent value 10 |
141 |
Percent value 11 |
142 |
Percent value 12 |
143 |
Percent value 13 |
144 |
Percent value 14 |
145 |
Percent value 15 |
146 |
Percent value 16 |
147 |
Percent value 17 |
148 |
Percent value 18 |
149 |
Percent value 19 |
150 |
Percent value 20 |
151 |
Percent value 21 |
152 |
Percent value 22 |
153 |
Percent value 23 |
154 |
Percent value 24 |
155 |
Percent value 25 |
156 |
Percent value 26 |
157 |
Percent value 27 |
158 |
Percent value 28 |
159 |
Percent value 29 |
160 |
Percent value 30 |
161 |
Percent value 31 |
162 |
Current value 1 |
163 |
mA |
164 |
Current value 2 |
165 |
Current value 3 |
166 |
Current value 4 |
167 |
Current value 5 |
168 |
Current value 6 |
169 |
Current value 7 |
170 |
Current value 8 |
171 |
Current value 9 |
172 |
Current value 10 |
173 |
Current value 11 |
174 |
Current value 12 |
175 |
Current value 13 |
176 |
Current value 14 |
177 |
Current value 15 |
178 |
Current value 16 |
179 |
Current value 17 |
180 |
Current value 18 |
181 |
Current value 19 |
182 |
Current value 20 |
183 |
Current value 21 |
184 |
Current value 22 |
185 |
Current value 23 |
186 |
Current value 24 |
187 |
Current value 25 |
188 |
Current value 26 |
189 |
Current value 27 |
190 |
Current value 28 |
191 |
Current value 29 |
192 |
Current value 30 |
193 |
Current value 31 |
194 |
|
195 |
Pressure unit |
196 |
Engineering unit to be displayed with the digital value representation,minimum span, upper range value, lower range value, lower sensor limit, and upper sensor limit. |
197 |
Module compatibility |
198 |
O.K. |
199 |
ERROR |
200 |
Module compatibility |
201 |
Module compatibility |
202 |
Firmware rev |
203 |
Hardware rev |
204 |
Switching module software revision |
205 |
Sw module hw rev |
206 |
HART module software revision |
207 |
HART mod hw rev |
208 |
Display module software revision |
209 |
LCD mod hw rev |
210 |
Sw module s/n |
211 |
HART mod s/n |
212 |
LCD module s/n |
213 |
Decimal point |
214 |
Number of digits on the right-hand side of the decimal point for out. |
215 |
0 |
216 |
1 |
217 |
2 |
218 |
3 |
219 |
4 |
220 |
Temperature unit |
221 |
Unit - The temperature unit |
222 |
LCD unit |
223 |
Display unit- unit that is displayed on the LCD display |
224 |
Sensor model - the order number for this field device |
225 |
Snsr model |
226 |
-400..400 mbar |
227 |
-1000..1000 mbar |
228 |
-1000..4000 mbar |
229 |
-1000..16000 mbar |
230 |
-1000..40000 mbar |
231 |
-1000..100000 mbar |
232 |
-1000..400000 mbar |
233 |
0..4000 mbar |
234 |
0..16000 mbar |
235 |
Pressure (GP) |
236 |
Absolute pressure |
237 |
Differential pressure |
238 |
Level |
239 |
dummy |
240 |
Identification |
241 |
Operation unit |
242 |
Device |
243 |
Basic module |
244 |
Sensor module |
245 |
Switching module |
246 |
HART module |
247 |
Display module |
248 |
Input |
249 |
Sensor limits |
250 |
Operating range |
251 |
Min / max values |
252 |
Sensor temp |
253 |
Output |
254 |
Sensor trim points |
255 |
Characterization |
256 |
Table |
257 |
Alarms |
258 |
Display and handling |
259 |
Switches / Contacts |
260 |
Switch contact 1 |
261 |
Switch contact 2 |
262 |
Local display |
263 |
Certificates |
264 |
HART |
265 |
Status |
266 |
Function module |
267 |
Switching module |
268 |
Min/max pointer |
269 |
Pressure pointer |
270 |
Temperature pointer |
271 |
Test / Reset |
272 |
Sensor trim |
273 |
Zero calibration |
274 |
Lower sensor trim |
275 |
Upper sensor trim |
276 |
Output trim |
277 |
Loop test |
278 |
Allows the user to manually manipulate the analog output to a selected constant output value. |
279 |
Self Test |
280 |
Cfg changed reset |
281 |
Commands a reset of the configuration flag. |
282 |
Master reset |
283 |
Commands the field device electronics to reset. |
284 |
Factory reset |
285 |
ATTENTION! This will reset all user configured data to factory default values! |
286 |
Analog output |
287 |
Press zero trim |
288 |
Zero trim: Make the sensor input the new zero input reference. |
289 |
Accept sensor change |
290 |
Toolbar |
291 |
Status bar |
292 |
Update F5 |
293 |
Communication path |
294 |
Load to device |
295 |
Load to PG/PC |
296 |
Customize... |
297 |
Subitems |
298 |
Lower sensor trim |
299 |
Pressure Sensor Lower Trim - Adjust the lower range value. |
300 |
Upper sensor trim |
301 |
Pressure Sensor Upper Trim - Adjust the upper range value. |
302 |
Exit Trim Mode- Notifies the User that the trim is finished. |
303 |
Transfer |
304 |
Transfer - transfers the inputs to the field device |
305 |
Reset Min/Max |
306 |
Reset minimum maximum tracking values. |
307 |
Reset temperature minimum maximum tracking values. |
308 |
|
309 |
PASCAL CV |
310 |
PV outside limits |
311 |
Non-pv outside limits |
312 |
AO outside rnge limits |
313 |
AO fixed mode |
314 |
More status available |
315 |
Cold start occured |
316 |
Configuration changed |
317 |
Field dev malfunction |
318 |
Address |
319 |
Transfer function |
320 |
Linear |
321 |
Spcl curve |
322 |
PV upper range val |
323 |
PV lower range val |
324 |
Error current |
325 |
Analog output alarm type - defines how the analog output will respond when the field device detects that the analog output may not be tracking the associated field device Variable. NOTE - The digital value representation may not be determinate. |
326 |
Current table invalid |
327 |
BM flash faulty |
328 |
Undefined |
329 |
Snsr comm faulty |
330 |
Snsr mod EEP faulty |
331 |
BM EEP faulty |
332 |
Snsr mod unknown |
333 |
Bridge faulty |
334 |
Pres Class |
335 |
Uniquely identifies the sensor from which the digital value representation or field device variable is primarily derived. |
336 |
7d |
337 |
Upper value max |
338 |
Upper value max: defines the maximum usable value for the measuring range (sensor). |
339 |
LSL |
340 |
Lower sensor limit value - defines the minimum usable value for the lower range value. |
341 |
Minimum span value - defines the smallest allowable difference between the upper range value and the lower range value. |
342 |
Damping: damping time constant applied to both the digital value representation and analog value of the respective analog output.The units of this variable are always in seconds. |
343 |
Snsr temp unit |
344 |
Sensor Temperature Units- Engineering unit to be displayed with Sensor Temperature. |
345 |
°C |
346 |
°F |
347 |
°R |
348 |
K |
349 |
Temp Class |
350 |
Secondary Variable - Temperature Compensation |
351 |
PASCAL CV |
352 |
Online |
353 |
Device setup |
354 |
Basic setup |
355 |
Diag/Service |
356 |
Download Variables |
357 |
Upload Variables |
358 |
Common Tables |
359 |
Interoperable * |
360 |
Universal |
361 |
Common Practice |
362 |
Pressure Universal |
363 |
Pressure Common |
364 |
Menu |
365 |
Rosemount Magflow |
366 |
Rosemount Pressure |
367 |
Moore Products |
368 |
Siemens Pressure |
369 |
P2 Common |
370 |
PV |
371 |
Munge |
372 |
Analytical Oxygen/Combustion/Methane/CO |
373 |
Flow Totalizer - Rate Indicator |
374 |
Flow Variable Area |
375 |
Flow Coriolis Mass |
376 |
Level Ultrasonic |
377 |
Level Radar - Microwave |
378 |
Pressure Absolute |
379 |
Level Capacitance |
380 |
Pressure Differential |
381 |
Level Hydrostatic |
382 |
Level |
383 |
Pressure Absolute/Relative |
384 |
Level Microwave |
385 |
Level Radar |
386 |
Level Density - Nuclear |
387 |
Pressure Deltabar S Evolution |
388 |
Pressure Cerabar S Evolution |
389 |
Flow Electromagnetic |
390 |
Flow Vortex |
391 |
Flow Magmeter - Rack Version |
392 |
Flow High Performance Magmeter |
393 |
Flow Mass |
394 |
Flow Ultrasonic |
395 |
Flow Magnetic |
396 |
Flow Magnetic - Custody Transfer |
397 |
Flow 2-wire Magnetic |
398 |
Flow Coriolis Mass - Custody Transfer |
399 |
Flow 2-wire Vortex |
400 |
Flow Thermal |
401 |
Temperature Head Mounted |
402 |
Temperature Compact |
403 |
Temperature DIN Rail Mounted |
404 |
Analytical pH |
405 |
Analytical Conductivity - Conductive |
406 |
Analytical Conductivity - Inductive |
407 |
Temperature Sensor |
408 |
Level Servo |
409 |
Temperature DIN Rail |
410 |
Temperature |
411 |
Analytical ORP |
412 |
Analytical pION |
413 |
Analytical IConc |
414 |
Analytical Electrode Conductivity |
415 |
Analytical Toroidal Conductivity |
416 |
Valve Controller |
417 |
Pressure |
418 |
Pressure Multivariable |
419 |
Analytical pH/ORP |
420 |
Flow Coriolis |
421 |
Analytical Conductivity |
422 |
Valve Positioner/Pneumatic |
423 |
Valve Actuator - Electrical |
424 |
Temperature Dual Input |
425 |
Valve Actuator |
426 |
Analytical Corrosion |
427 |
Analytical Density - Nuclear |
428 |
Level Continuous Gamma |
429 |
Level Laser Ranging |
430 |
Pressure Safety |
431 |
Analytical 4 Electrode Conductivity |
432 |
Analytical 2 Electrode Conductivity |
433 |
Analytical Troidal Conductivity |
434 |
Pressure P, dP + Multivariable |
435 |
Temperature 2-wire |
436 |
Pressure w/ PID |
437 |
Pressure Saturated Steam |
438 |
Analytical Density - Gamma Ray |
439 |
Level Gamma Ray |
440 |
Analytical Weight - Gamma Ray |
441 |
Level w/ Density - Gamma Ray |
442 |
Analytical Motorized Density |
443 |
Flow Multivariable Mass |
444 |
Temperature Multivariable |
445 |
Specialty HART-to-Analog Signal Conv |
446 |
Flow dP |
447 |
Pressure Low Power |
448 |
Pressure Certified SIL2 |
449 |
Interoperable |
450 |
Analytical Density |
451 |
Valve Positioner/Electropneumatic |
452 |
Flow Magnetic Inductive |
453 |
Flow |
454 |
Analytical Oxygen |
455 |
Analytical |
456 |
Analytical Opacity Monitor |
457 |
Analytical Oxygen/Combustion |
458 |
Analytical 2-wire Conductivity |
459 |
Analytical 2-wire Conductivity w/ pure H20 |
460 |
Analytical 2-wire Conductivity w/ % conc |
461 |
Analytical 2-wire Oxygen/Chlorine/Ozone |
462 |
Analytical 2-wire pH/ORP |
463 |
Analytical 2-wire Contacting/Toroidal |
464 |
Analytical Oxygen - High Temperature |
465 |
Analytical Conductivity w/ % conc |
466 |
Analytical pH/ORP/ISE |
467 |
Analytical Amperometric Analyzer |
468 |
Pressure Pressure/Level |
469 |
Analytical Consistency |
470 |
Analytical Microwave-Pulp Consistency |
471 |
Valve Digital Positioner |
472 |
Valve Positioner |
473 |
Valve Smart Valve Positioner |
474 |
Temperature Differential |
475 |
Analytical Dissolved Oxygen |
476 |
Analytical pH Controller |
477 |
Analytical Conductivity/Resistivity Controller |
478 |
Analytical Conductivity/Resistivity |
479 |
Level Displacement |
480 |
Temperature w/ PID |
481 |
Valve Universal Positioner |
482 |
Level Radar - Reflex |
483 |
Pressure Gauge |
484 |
Pressure Sealed Gauge |
485 |
Valve Digital Positioner w/ PID |
486 |
Valve Intelligent Positioner |
487 |
Analytical Gas Detector |
488 |
Analytical Infrared Gas Detector |
489 |
Analytical Electrochemical Gas Detector |
490 |
Level Magnostrictive |
491 |
Valve On/Off Valve Controller |
492 |
Level Radar - Pulse |
493 |
Level Continuous Capactive |
494 |
Valve Damper Actuator |
495 |
Valve Electric Damper Actuator |
496 |
Flow Electronic |
497 |
Flow Vortex - Multiparameter Mass |
498 |
Analytical Flame Detector |
499 |
Level Nuclear |
500 |
Analytical Microwave |
501 |
Analytical Density - Radiometric |
502 |
Level Radiometric |
503 |
Analytical Gas/Steam |
504 |
Level Nucleonic |
505 |
Analytical Blade Consistency |
506 |
Analytical Rotary Consistency |
507 |
level family |
508 |
vortex flow family |
509 |
mag flow family |
510 |
coriolis flow famliy |
511 |
level |
512 |
vortex flow |
513 |
mag flow |
514 |
coriolis flow |
515 |
FMU860 |
516 |
DT |
517 |
DVC |
518 |
FCX |
519 |
AS800 |
520 |
340T |
521 |
340C |
522 |
344 |
523 |
Siemens Micro K |
524 |
SITRANS L |
525 |
SIPAN PH |
526 |
SITRANS P |
527 |
75SMT |
528 |
UNIDELTA |
529 |
8320 |
530 |
SX5100 |
531 |
TSV175 |
532 |
DMU |
533 |
3780 |
534 |
BM70 |
535 |
8u |
536 |
8.3f |
537 |
count |
538 |
Execute self test? |
539 |
Yes;No |
540 |
Self test OK |
541 |
Execute configuration flag reset? |
542 |
Execute master reset? |
543 |
WARNING: Loop should be removed from automatic control |
544 |
Please wait 15 s ... |
545 |
Master reset OK |
546 |
Execute factory reset? |
547 |
ATTENTION! This will reset all user configured data to factory default values! |
548 |
Please wait 20 s ... |
549 |
Factory reset failed |
550 |
Factory reset OK |
551 |
NOTE: Loop may be returned to automatic control |
552 |
Apply low pressure |
553 |
Press OK when pressure is stable |
554 |
Enter applied pressure value |
555 |
trim_point |
556 |
Remove pressure |
557 |
Apply hi pressure |
558 |
Trim was not done |
559 |
Select to reset |
560 |
Max (R);Min (R);Max (R) & Min (R) |
561 |
Reset |
562 |
No;Yes |
563 |
Pointer min (R) is reset |
564 |
Pointer max (R) is reset |
565 |
Pointers max (R) & min (R) are reset |
566 |
Process was aborted,
settings are possibly not completed. |
567 |
Fld dev output %0 mA equal to reference meter? |