0 |
Flow Speed |
1 |
Volume Flow |
2 |
Mass Flow |
3 |
Temperature |
4 |
Density |
5 |
Sensor Average |
6 |
Sensor Deviation |
7 |
Sensor Drive Level |
8 |
Tube Frequency |
9 |
Strain Measurement Tube |
10 |
Strain Int Case |
11 |
2 Phase Signal |
12 |
Concentration 1 |
13 |
Concentration 2 |
14 |
Concentration Mass Flow 1 |
15 |
Concentration Volume Flow 1 |
16 |
Concentration Mass Flow 2 |
17 |
Concentration Volume Flow 2 |
18 |
Counter 1 Mass |
19 |
Counter 1 Volume |
20 |
Counter 2 Mass |
21 |
Counter 2 Volume |
22 |
Counter 3 Mass |
23 |
Counter 3 Volume |
24 |
Snsr s/n |
25 |
Unit |
26 |
Format Flow Speed |
27 |
Display format for Flow Speed.
Local for HART applications, no correlation with device's local display. |
28 |
#X.XX (default) |
29 |
#X. |
30 |
#X.X |
31 |
#X.XXX |
32 |
#X.XXXX |
33 |
#X.XXXXX |
34 |
#X.XXXXXX |
35 |
#X.XXXXXXX |
36 |
#X.XXXXXXXX |
37 |
exponential format |
38 |
auto format |
39 |
Flow Speed |
40 |
Shows the current measurement for Flow Speed. |
41 |
.0f |
42 |
.1f |
43 |
.2f |
44 |
.3f |
45 |
.4f |
46 |
.5f |
47 |
.6f |
48 |
.7f |
49 |
.8f |
50 |
6e |
51 |
g |
52 |
Time constant |
53 |
Time constant for Flow Speed |
54 |
Upper Sensor Limit |
55 |
Lower Sensor Limit |
56 |
Minimum Span |
57 |
Unit Class Flow Speed |
58 |
Device Variable Class.
Defines also the set of selectable physical units. |
59 |
Family |
60 |
Device Variable Family |
61 |
Data Quality |
62 |
Process Data Quality 'PDQ' |
63 |
Limit Status |
64 |
Limit Status 'LS' |
65 |
Family Status |
66 |
Family Status 'FS' |
67 |
More device family status available |
68 |
Update Time |
69 |
Update Time Period 'UTP'.
Indicates the maximum period between updates of the process variable. |
70 |
Set Simulation |
71 |
Desired setting of the process variable simulation.
If enabled, the process variable will be simulated and won't show the actual process value. |
72 |
disabled |
73 |
enabled |
74 |
Properties |
75 |
Properties, indicate e.g. the simulation state. |
76 |
Computed extern |
77 |
Process Variable is not calculated by the field device. |
78 |
Simulated |
79 |
Current state of the process variable simulation.
If active, the process variable is simulated and doesn't show the actual process value. |
80 |
Format Volume Flow |
81 |
Display format for Volume Flow.
Local for HART applications, no correlation with device's local display. |
82 |
Volume Flow |
83 |
Shows the current measurement for Volume Flow. |
84 |
Time constant for Volume Flow |
85 |
Unit Class Volume Flow |
86 |
Format Mass Flow |
87 |
Display format for Mass Flow.
Local for HART applications, no correlation with device's local display. |
88 |
Mass Flow |
89 |
Shows the current measurement for Mass Flow. |
90 |
Time constant for Mass Flow |
91 |
Unit Class Mass Flow |
92 |
Format Temperature |
93 |
Display format for Temperature.
Local for HART applications, no correlation with device's local display. |
94 |
Temperature |
95 |
Shows the current measurement for Temperature. |
96 |
Time constant for Temperature |
97 |
Unit Class Temperature |
98 |
Format Density |
99 |
Display format for Density.
Local for HART applications, no correlation with device's local display. |
100 |
Density |
101 |
Shows the current measurement for Density. |
102 |
Time constant for Density |
103 |
Unit Class Density |
104 |
Format Sensor Average |
105 |
Display format for Sensor Average.
Local for HART applications, no correlation with device's local display. |
106 |
Sensor Average |
107 |
Shows the current measurement for Sensor Average. |
108 |
Time constant for Sensor Average |
109 |
Unit Class Sensor Average |
110 |
Format Sensor Deviation |
111 |
Display format for Sensor Deviation.
Local for HART applications, no correlation with device's local display. |
112 |
Sensor Deviation |
113 |
Shows the current measurement for Sensor Deviation. |
114 |
Time constant for Sensor Deviation |
115 |
Unit Class Sensor Deviation |
116 |
Format Sensor Drive Level |
117 |
Display format for Sensor Drive Level.
Local for HART applications, no correlation with device's local display. |
118 |
Sensor Drive Level |
119 |
Shows the current measurement for Sensor Drive Level. |
120 |
Time constant for Sensor Drive Level |
121 |
Unit Class Sensor Drive Level |
122 |
Format Tube Frequency |
123 |
Display format for Tube Frequency.
Local for HART applications, no correlation with device's local display. |
124 |
Tube Frequency |
125 |
Shows the current measurement for Tube Frequency. |
126 |
Time constant for Tube Frequency |
127 |
Unit Class Tube Frequency |
128 |
Format Strain Measurement Tube |
129 |
Display format for Strain Measurement Tube.
Local for HART applications, no correlation with device's local display. |
130 |
Strain Measurement Tube |
131 |
Shows the current measurement for Strain Measurement Tube. |
132 |
Time constant for Strain Measurement Tube |
133 |
Unit Class Strain Measurement Tube |
134 |
Format Strain Int Case |
135 |
Display format for Strain Int Case.
Local for HART applications, no correlation with device's local display. |
136 |
Strain Int Case |
137 |
Shows the current measurement for Strain Int Case. |
138 |
Time constant for Strain Int Case |
139 |
Unit Class Strain Int Case |
140 |
Format 2 Phase Signal |
141 |
Display format for 2 Phase Signal.
Local for HART applications, no correlation with device's local display. |
142 |
2 Phase Signal |
143 |
Shows the current measurement for 2 Phase Signal. |
144 |
Time constant for 2 Phase Signal |
145 |
Unit Class 2 Phase Signal |
146 |
Unit Concentration 1 |
147 |
Unit for Concentration 1. |
148 |
°Bx |
149 |
°Bm |
150 |
Pto |
151 |
API |
152 |
|
153 |
Format Concentration 1 |
154 |
Display format for Concentration 1.
Local for HART applications, no correlation with device's local display. |
155 |
Concentration 1 |
156 |
Shows the current measurement for Concentration 1. |
157 |
Time constant for Concentration 1 |
158 |
Unit Class Concentration 1 |
159 |
Unit Concentration 2 |
160 |
Unit for Concentration 2. |
161 |
Format Concentration 2 |
162 |
Display format for Concentration 2.
Local for HART applications, no correlation with device's local display. |
163 |
Concentration 2 |
164 |
Shows the current measurement for Concentration 2. |
165 |
Time constant for Concentration 2 |
166 |
Unit Class Concentration 2 |
167 |
Format Concentration Mass Flow 1 |
168 |
Display format for Concentration Mass Flow 1.
Local for HART applications, no correlation with device's local display. |
169 |
Concentration Mass Flow 1 |
170 |
Shows the current measurement for Concentration Mass Flow 1. |
171 |
Time constant for Concentration Mass Flow 1 |
172 |
Unit Class Concentration Mass Flow 1 |
173 |
Format Concentration Volume Flow 1 |
174 |
Display format for Concentration Volume Flow 1.
Local for HART applications, no correlation with device's local display. |
175 |
Concentration Volume Flow 1 |
176 |
Shows the current measurement for Concentration Volume Flow 1. |
177 |
Time constant for Concentration Volume Flow 1 |
178 |
Unit Class Concentration Volume Flow 1 |
179 |
Format Concentration Mass Flow 2 |
180 |
Display format for Concentration Mass Flow 2.
Local for HART applications, no correlation with device's local display. |
181 |
Concentration Mass Flow 2 |
182 |
Shows the current measurement for Concentration Mass Flow 2. |
183 |
Time constant for Concentration Mass Flow 2 |
184 |
Unit Class Concentration Mass Flow 2 |
185 |
Format Concentration Volume Flow 2 |
186 |
Display format for Concentration Volume Flow 2.
Local for HART applications, no correlation with device's local display. |
187 |
Concentration Volume Flow 2 |
188 |
Shows the current measurement for Concentration Volume Flow 2. |
189 |
Time constant for Concentration Volume Flow 2 |
190 |
Unit Class Concentration Volume Flow 2 |
191 |
Format Counter 1 Mass |
192 |
Display format for Counter 1 Mass.
Local for HART applications, no correlation with device's local display. |
193 |
Counter 1 Mass |
194 |
Shows the current measurement for Counter 1 Mass. |
195 |
Time constant for Counter 1 Mass |
196 |
Unit Class Counter 1 Mass |
197 |
Format Counter 1 Volume |
198 |
Display format for Counter 1 Volume.
Local for HART applications, no correlation with device's local display. |
199 |
Counter 1 Volume |
200 |
Shows the current measurement for Counter 1 Volume. |
201 |
Time constant for Counter 1 Volume |
202 |
Unit Class Counter 1 Volume |
203 |
Format Counter 2 Mass |
204 |
Display format for Counter 2 Mass.
Local for HART applications, no correlation with device's local display. |
205 |
Counter 2 Mass |
206 |
Shows the current measurement for Counter 2 Mass. |
207 |
Time constant for Counter 2 Mass |
208 |
Unit Class Counter 2 Mass |
209 |
Format Counter 2 Volume |
210 |
Display format for Counter 2 Volume.
Local for HART applications, no correlation with device's local display. |
211 |
Counter 2 Volume |
212 |
Shows the current measurement for Counter 2 Volume. |
213 |
Time constant for Counter 2 Volume |
214 |
Unit Class Counter 2 Volume |
215 |
Format Counter 3 Mass |
216 |
Display format for Counter 3 Mass.
Local for HART applications, no correlation with device's local display. |
217 |
Counter 3 Mass |
218 |
Shows the current measurement for Counter 3 Mass. |
219 |
Time constant for Counter 3 Mass |
220 |
Unit Class Counter 3 Mass |
221 |
Format Counter 3 Volume |
222 |
Display format for Counter 3 Volume.
Local for HART applications, no correlation with device's local display. |
223 |
Counter 3 Volume |
224 |
Shows the current measurement for Counter 3 Volume. |
225 |
Time constant for Counter 3 Volume |
226 |
Unit Class Counter 3 Volume |
227 |
eSelectionAnalogOutput |
228 |
PV |
229 |
SV |
230 |
TV |
231 |
QV |
232 |
eSelectionCurrentOutput |
233 |
ms |
234 |
Milliseconds |
235 |
Pa*s |
236 |
Pascalsecond |
237 |
Krohne |
238 |
MFC400S |
239 |
Failure |
240 |
Operational fault in device. No measurement possible.
(NE 107 status signal). |
241 |
Function check |
242 |
Testing mode by invoking test or simulation functions.
(NE 107 status signal). |
243 |
Out of specification |
244 |
Out of specification, measurement continues with less accuracy.
(NE 107 status signal). |
245 |
Device Diagnostic Status 1 |
246 |
Status commonly used in a wide range of devices and device types |
247 |
Device Status Simulation |
248 |
The displayed device status is simulated and does not show the actual state. |
249 |
Config: No Meas. Value |
250 |
Electr: Operation Info. |
251 |
Electr: IO Connection |
252 |
Proc: Signal Search |
253 |
Proc: 2 Phase Flow |
254 |
Proc: Signal Low |
255 |
Config: Totaliser |
256 |
Proc: System Control |
257 |
Electr: Power Failure |
258 |
S Sensor |
259 |
S Electronics |
260 |
S Configuration |
261 |
S Process |
262 |
M Electronics |
263 |
M Configuration |
264 |
F Sensor |
265 |
F Electronics |
266 |
F Configuration |
267 |
C Configuration |
268 |
Analog Input Channel |
269 |
Upper Limit Value |
270 |
The maximum value of the analog signal. |
271 |
Lower Limit Value |
272 |
The minimum value of the analog signal. |
273 |
DD-Version |
274 |
Version number of the device description according to NAMUR recommendation.
You are currently working with version: 01.12 |
275 |
01.12 |
276 |
PreSetVersionDd |
277 |
Reset Configuration Changed Flag |
278 |
Reset of the HART 'Configuration Changed' flag. |
279 |
Device reset |
280 |
Perform a "cold start" (like power-on start). |
281 |
colVerIdMeasurementCoC |
282 |
colVerIdLowerRangeValue |
283 |
colVerIdUpperRangeValue |
284 |
colVerIdScoAlarmCode |
285 |
colVerIdThresholdLfcRelativeCoC |
286 |
colVerIdHysteresisLfcRelativeCoC |
287 |
colVerIdScoTimeconstant |
288 |
colVerIdTypeIoC |
289 |
colVerIdPolarityCoC |
290 |
colVerIdZeroFlowOffsetPercent |
291 |
colVerIdSafetyMode |
292 |
lblbeAslActivation |
293 |
AslJumperSet |
294 |
AslActive |
295 |
reserved |
296 |
lblbeAslCategories |
297 |
Sensor |
298 |
SensorCalibration |
299 |
TerminalA |
300 |
TerminalB |
301 |
TerminalC |
302 |
TerminalD |
303 |
Totalizer1 |
304 |
HmiConfiguration |
305 |
SilFixed |
306 |
SilOperation |
307 |
LockConfiguration |
308 |
Safety State |
309 |
Cold Start |
310 |
Non-SIL Operation |
311 |
Safe Configuration |
312 |
Safe Operation |
313 |
u16SaveParameterizationPassword |
314 |
u16ConfirmationKey |
315 |
uVerificationParameterId |
316 |
st32VerificationString |
317 |
u8VerficationParameterIndex |
318 |
|
319 |
ID not valid |
320 |
valid ID |
321 |
uNumberOfValidVerificationParameterIds |
322 |
eTriggerSparInitialization |
323 |
true |
324 |
false |
325 |
Password Result |
326 |
successfull |
327 |
wrong key |
328 |
Unlock Device |
329 |
Unlock device and switch to safe parameterization state.
(A6, C7.4) |
330 |
SIL Verification |
331 |
Verification of safety mode (non-SIL) or safety rel. param (SIL). |
332 |
Set Safety Mode |
333 |
Select safety mode of the device.
(A4, C7.2) |
334 |
Set Write Lock Selection |
335 |
Selection of locked parameter groups for lock jumper.
(C6.3.6) |
336 |
Velocity |
337 |
Volume Flow |
338 |
Temperature |
339 |
Density |
340 |
Mass Flow |
341 |
Strain 1 |
342 |
Strain 2 |
343 |
Tube Frequency |
344 |
Drive Level |
345 |
Sensor A Level |
346 |
Sensor B Level |
347 |
2 Phase Signal |
348 |
Electronics Temp. |
349 |
Passed |
350 |
Failed - not meas. |
351 |
Failed - zero too high |
352 |
Failed |
353 |
Max. Rec. Temp. |
354 |
Min. Rec. Temp. |
355 |
Time Shift |
356 |
ns |
357 |
Zero Flow Offset |
358 |
0.4f |
359 |
Flow Temp. Comp. |
360 |
Beta Correction |
361 |
Density Temp. Comp. |
362 |
Density Flow Comp. |
363 |
CF9 |
364 |
0.6f |
365 |
CF10 |
366 |
Failed - points close |
367 |
Failed - plausibility |
368 |
Tube Driver |
369 |
Drive A (compact) |
370 |
Drive B (remote) |
371 |
Min. Tube Amplitude |
372 |
3.1f |
373 |
Nominal Mass Flow |
374 |
7.0f |
375 |
Drive Phase Limit |
376 |
Drive Phase LP |
377 |
Sensor Type |
378 |
Sensor ID |
379 |
Function Statusoutput |
380 |
Set condition to activate status output.
(C2.2.2) |
381 |
Status Off |
382 |
Polarity |
383 |
Over Range |
384 |
Range Change B |
385 |
Same Signal |
386 |
Set condition to activate status output.
(C2.3.2) |
387 |
Range Change A |
388 |
Output A |
389 |
Set condition to activate status output.
(C2.5.2) |
390 |
Conc. Function |
391 |
Select the function of the 1st concentration measurement.
(C1.3.2.1) |
392 |
Off |
393 |
Brix |
394 |
% Mass |
395 |
% Volume |
396 |
Baume 144 |
397 |
Baume 145 |
398 |
% NaOH |
399 |
Plato |
400 |
API |
401 |
% Alcohol by mass |
402 |
% Alcohol by volume |
403 |
Select the function of the 2nd concentration measurement.
(C1.3.3.1) |
404 |
Concentration option |
405 |
Concentration option enable |
406 |
Disabled |
407 |
Enabled |
408 |
Diagnosis 1 |
409 |
Select diagnostics measurement which is available at output.
(C1.5.2) |
410 |
Sensor Average |
411 |
Sensor Deviation |
412 |
Drive Level |
413 |
Diagnosis 2 |
414 |
Select diagnostics measurement which is available at output.
(C1.5.3) |
415 |
Hz |
416 |
mA |
417 |
On |
418 |
HART |
419 |
Enable/Disable HART communication.
(C4.1) |
420 |
Language |
421 |
Set language of the menu.
(A1, C5.1) |
422 |
English |
423 |
Deutsch |
424 |
Français |
425 |
Dansk |
426 |
Español |
427 |
Italiano |
428 |
Nederlands |
429 |
Norsk |
430 |
Polski |
431 |
Português |
432 |
Svenska |
433 |
Türkçe |
434 |
Select Range |
435 |
Select range mode for graphic page.
(C5.8.1) |
436 |
Manual |
437 |
Automatic |
438 |
Y-Axis Average |
439 |
Set scaling for graphic page Y-axis. |
440 |
3.0f |
441 |
Y-Axis +/- Range |
442 |
Time Scale |
443 |
Time scale for graphic page X-axis.
(C5.8.3) |
444 |
Safety Mode |
445 |
Select safety mode of the device. |
446 |
non-SIL Mode |
447 |
SIL Mode |
448 |
Not initialized |
449 |
Checking Parameters... |
450 |
Please Wait ... |
451 |
Press Return to Start |
452 |
Successful |
453 |
Remove Jumper |
454 |
Config. invalid |
455 |
Wrong Key |
456 |
Timeout occured |
457 |
Operating Hours |
458 |
Einheitenklasse Masse |
459 |
Einheitenklasse Volumen |
460 |
[m³]*Factor |
461 |
Set free unit factor for Volume.
(C6.5.12) |
462 |
Text Free Unit |
463 |
Set free unit text for Volume.
(C6.5.11) |
464 |
[kg]*Factor |
465 |
Set free unit factor for Mass.
(C6.5.15) |
466 |
Set free unit text for Mass.
(C6.5.14) |
467 |
[m³/s]*Factor |
468 |
Set free unit factor for Volume Flow.
(C6.5.3) |
469 |
Set free unit text for Volume Flow.
(C6.5.2) |
470 |
[kg/s]*Factor |
471 |
Set free unit factor for Mass Flow.
(C6.5.6) |
472 |
Set free unit text for Mass Flow.
(C6.5.5) |
473 |
[kg/m³]*Factor |
474 |
Set free unit factor for Density.
(C6.5.18) |
475 |
Set free unit text for Density.
(C6.5.17) |
476 |
Sensor Serial No. |
477 |
Electronics Serial No. |
478 |
C Number |
479 |
Detected C-No. |
480 |
Change Log |
481 |
Display log containing the checksum over the entire configuration..
(B1.2) |
482 |
Set Operator Password |
483 |
Enable access authentication by setting access code.
(C6.3.4) |
484 |
Unlock Password |
485 |
Set unlock password for SIL Operation.
(C7.5) |
486 |
Write Lock Selection |
487 |
None |
488 |
Term. C+S |
489 |
Term. D+S |
490 |
Term. BD+S |
491 |
Term. CD+S |
492 |
Term. ABD+S |
493 |
Term. BCD+S |
494 |
Term. ABCD+S |
495 |
HMI+S+Tot.1 |
496 |
Term. C+S+HMI+Tot.1 |
497 |
Term. D+S+HMI+Tot.1 |
498 |
Term. BD+S+HMI+Tot.1 |
499 |
Term. CD+S+HMI+Tot.1 |
500 |
Term. ABD+S+HMI+Tot.1 |
501 |
Term. BCD+S+HMI+Tot.1 |
502 |
Term. ABCD+S+HMI+Tot.1 |
503 |
V No. Sensor |
504 |
V No. Converter |
505 |
Sensor Revision |
506 |
Damping |
507 |
Set damping for output.
(C2.2.4) |
508 |
4.1f |
509 |
RC Threshold |
510 |
RC Hysteresis |
511 |
Polarity |
512 |
Set response of output to measurement polarity.
(C2.2.4/5/6) |
513 |
Both Polarities |
514 |
Positive Polarity |
515 |
Negative Polarity |
516 |
Absolute Value |
517 |
Special Function |
518 |
Set range change for current output.
(C2.2.11) |
519 |
Automatic Range |
520 |
External Range |
521 |
LFC Threshold |
522 |
Set low flow cutoff for output.
(C2.2.3) |
523 |
Alarm Code |
524 |
Set alarm signal for current output.
(C2.2.9) |
525 |
Range 100% |
526 |
Set current endpoints for current output.
(C2.2.7) |
527 |
Limitation Max |
528 |
Set current limits for current output.
(C2.2.8) |
529 |
High |
530 |
Low |
531 |
Limitation Min |
532 |
Alarm Condition |
533 |
Set condition for alarm in output.
(C2.2.10) |
534 |
Failure |
535 |
Out Of Specification |
536 |
Range 0% |
537 |
Set damping for output.
(C2.2.3/5) |
538 |
LFC Hysteresis |
539 |
Damping C |
540 |
Set damping for output.
(A3.6, C2.4.4, C7.1.6) |
541 |
Set response of output to measurement polarity.
(C2.4.4/5) |
542 |
Pulse Width |
543 |
Set pulse width of frequency/pulse output.
(C2.2.7/8) |
544 |
6.2f |
545 |
Pulse Shape |
546 |
Set pulse shape of frequency/pulse output.
(C2.2.6/7) |
547 |
Symmetric |
548 |
Automatic |
549 |
Fixed |
550 |
Phase Shift w.r.t. B |
551 |
Set phase shift relative to output B.
(C2.2.10/11) |
552 |
0° Phase Shift |
553 |
90° Phase Shift |
554 |
180° Phase Shift |
555 |
Max. Pulse Rate |
556 |
Set pulse rate for 100% of measuring range of pulse output.
(C2.2.9) |
557 |
100% Pulse Rate |
558 |
Set pulse rate for 100% of measuring range for frequency output.
(C2.2.8) |
559 |
LFC Threshold C |
560 |
Set low flow cutoff for output.
(A3.5, C2.4.3, C7.1.5) |
561 |
LFC Hysteresis C |
562 |
Set current endpoints for current output.
(C2.4.7) |
563 |
Set current limits for current output.
(C2.4.8) |
564 |
Set alarm signal for current output.
(C2.4.9) |
565 |
Alarm Code C |
566 |
Set alarm signal for current output.
(A3.4, C2.4.9, C7.1.4) |
567 |
Set condition for alarm in output.
(C2.4.10, C7.1.12) |
568 |
Safety Rel. Failures |
569 |
Set damping for totaliser.
(C3.3.4) |
570 |
Totaliser Function |
571 |
Set function for totaliser.
(C3.3.1) |
572 |
Absolute Total |
573 |
Incremental Total |
574 |
Decremental Total |
575 |
Invert Signal |
576 |
Inverts signal at output.
(C2.2.3/9/10) |
577 |
Inverts signal at output.
(C2.2.5) |
578 |
Inverts signal at output.
(C2.3.3/9/10) |
579 |
Inverts signal at output.
(C2.3.5) |
580 |
Inverts signal at output.
(C2.4.5) |
581 |
Active |
582 |
Passive |
583 |
Terminals C Type |
584 |
Output type of terminal C.
(A3.7, C2.1.6, C7.1.7) |
585 |
NAMUR |
586 |
Terminals D Type |
587 |
Set the output type of terminal D.
(C2.1.8) |
588 |
Set damping for output.
(C2.3.4/5) |
589 |
Set threshold value for range change setting for current output.
(C2.3.12, C2.3.12.1) |
590 |
Set response of output to measurement polarity.
(C2.3.4/5/6) |
591 |
Set range change for current output.
(C2.3.11) |
592 |
Set alarm signal for current output.
(C2.3.9) |
593 |
Set condition for alarm in output.
(C2.3.10) |
594 |
Set current limits for current output.
(C2.3.8) |
595 |
Set current endpoints for current output.
(C2.3.7) |
596 |
Set low flow cutoff for output.
(C2.3.3) |
597 |
Set damping for output.
(C2.3.3) |
598 |
Set damping for output.
(C2.5.3/5) |
599 |
Set response of output to measurement polarity.
(C2.5.4/5/6) |
600 |
Set low flow cutoff for output.
(C2.5.3) |
601 |
Set pulse width of frequency/pulse output.
(C2.3.7/8) |
602 |
Set pulse shape of frequency/pulse output.
(C2.3.6/7) |
603 |
Set pulse rate for 100% of measuring range for frequency output.
(C2.3.8) |
604 |
0.5f |
605 |
Set pulse rate for 100% of measuring range of pulse output.
(C2.3.9) |
606 |
Enable phase shift relative to output A or D.
(C2.3.10/11) |
607 |
Phase Shift w.r.t. D |
608 |
Phase Shift w.r.t. A |
609 |
Set pulse width of frequency/pulse output.
(C2.5.7/8) |
610 |
Set pulse shape of frequency/pulse output.
(C2.5.6/7) |
611 |
Set phase shift relative to output B.
(C2.5.10/11) |
612 |
Inverts signal at output.
(C2.5.3/9/10) |
613 |
Set pulse rate for 100% of measuring range for frequency output.
(C2.5.8) |
614 |
Set damping for output.
(C2.5.4) |
615 |
Inverts signal at control input.
(C2.2.2) |
616 |
Inverts signal at output.
(C2.3.2) |
617 |
Failure Hold Time |
618 |
Set damping for totaliser.
(C3.1.4) |
619 |
Set damping for totaliser.
(C3.2.4) |
620 |
Set function for totaliser.
(C3.1.1) |
621 |
Set function for totaliser.
(C3.2.1) |
622 |
Set damping for output.
(C2.4.3) |
623 |
SIL certified sensor |
624 |
No |
625 |
Yes |
626 |
Expert mode |
627 |
Hardware detect D |
628 |
Pulse Output |
629 |
Hardware detect B |
630 |
Current Output |
631 |
Status Output |
632 |
Control Input |
633 |
Frequency Output |
634 |
current input |
635 |
Hardware detect A |
636 |
Hardware detect C |
637 |
Terminals A |
638 |
Set the output mode of terminal A.
(C2.1.1) |
639 |
Limit Switch |
640 |
Terminals B |
641 |
Set the output mode of terminal B.
(C2.1.3) |
642 |
Terminals C |
643 |
Set the output mode of terminal C.
(C2.1.5) |
644 |
Terminals D |
645 |
Set the output mode of terminal D.
(C2.1.7) |
646 |
Basic IO |
647 |
SIL IO Exi active |
648 |
SIL IO Exi passive |
649 |
SIL IO non-Exi |
650 |
FF |
651 |
Profibus |
652 |
Modbus |
653 |
Unused |
654 |
Pulse Value Unit |
655 |
Set unit for pulse value.
(C2.2.2, C2.2.3.2, C2.3.2, C2.3.3.2, C2.5.2, C2.5.3.2) |
656 |
mg |
657 |
g |
658 |
kg |
659 |
t |
660 |
oz |
661 |
lb |
662 |
ST |
663 |
LT |
664 |
Free Unit |
665 |
ml |
666 |
L |
667 |
hl |
668 |
m³ |
669 |
in³ |
670 |
cf |
671 |
yd³ |
672 |
gal |
673 |
IG |
674 |
barrel |
675 |
Set displayed units for Density.
(A3.3.3, B2.6.2, B3.4.2, C1.2.1.2, C1.2.3.2, C1.4.3.2, C1.4.4.2, C2.2.2.3, C2.3.2.3, C2.4.2.3, C2.5.2.3, C5.6.3.3, C5.7.3.3, C6.5.16, C7.1.3.3, D1.3.7.2) |
676 |
kg/m³ |
677 |
kg/L |
678 |
lb/cf |
679 |
lb/gal |
680 |
SG |
681 |
Volume |
682 |
Set displayed units for Volume.
(C3.1.3.3, C3.1.5.2, C3.1.7.2, C3.2.3.3, C3.2.5.2, C3.2.7.2, C3.3.3.3, C3.3.5.2, C3.3.7.2, C6.5.10) |
683 |
Mass |
684 |
Set displayed units for Mass.
(C3.1.3.3, C3.1.5.2, C3.1.7.2, C3.2.3.3, C3.2.5.2, C3.2.7.2, C3.3.3.3, C3.3.5.2, C3.3.7.2, C6.5.13) |
685 |
Flow Velocity |
686 |
Set displayed units for Flow Velocity.
(A3.3.3, B2.5.2, C2.2.2.3, C2.3.2.3, C2.4.2.3, C2.5.2.3, C5.6.3.3, C5.7.3.3, C6.5.7, C7.1.3.3) |
687 |
m/s |
688 |
ft/s |
689 |
Set displayed units for Volume Flow.
(A3.3.3, B2.4.2, B3.3.2, C2.2.2.3, C2.2.4.3, C2.3.2.3, C2.3.4.3, C2.4.2.3, C2.5.2.3, C2.5.4.3, C3.1.3.3, C3.2.3.3, C3.3.3.3, C5.6.3.3, C5.7.3.3, C6.5.1, C7.1.3.3) |
690 |
L/s |
691 |
L/min |
692 |
L/h |
693 |
m³/s |
694 |
m³/min |
695 |
m³/h |
696 |
cf/s |
697 |
cf/min |
698 |
cf/h |
699 |
gal/s |
700 |
gal/min |
701 |
gal/h |
702 |
IG/s |
703 |
IG/min |
704 |
IG/h |
705 |
barrel/h |
706 |
barrel/day |
707 |
Set displayed units for Mass Flow.
(A3.3.3, B2.3.2, B3.2.2, C1.1.2.2, C2.2.2.3, C2.2.4.3, C2.3.2.3, C2.3.4.3, C2.4.2.3, C2.5.2.3, C2.5.4.3, C3.1.3.3, C3.2.3.3, C3.3.3.3, C5.6.3.3, C5.7.3.3, C6.5.4, C7.1.3.3) |
708 |
g/s |
709 |
g/min |
710 |
g/h |
711 |
kg/s |
712 |
kg/min |
713 |
kg/h |
714 |
t/min |
715 |
t/h |
716 |
lb/s |
717 |
lb/min |
718 |
lb/h |
719 |
ST/min |
720 |
ST/h |
721 |
LT/h |
722 |
Set displayed units for Temperature.
(A3.3.3, B2.7.2, B2.15.2, B3.5.2, B4.7.2, B4.8.2, B4.9.2, B4.10.2, C1.2.4.2, C1.2.6.2, C1.4.3.2, C1.4.4.2, C2.2.2.2/3, C2.3.2.2/3, C2.4.2.2/3, C2.5.2.2/3, C5.6.3.3, C5.7.3.3, C6.5.9, C7.1.3.3, D1.4.10.2) |
723 |
K |
724 |
°C |
725 |
°F |
726 |
Limitation Max |
727 |
Set Min/Max for 1st line of measuring page. |
728 |
Limitation Min |
729 |
Set damping for 1st line of measuring page.
(C5.6.6) |
730 |
Low flow cutoff for 1st line of measuring page. |
731 |
Function |
732 |
Set number of lines of display on measuring page.
(C5.6.1) |
733 |
One Line |
734 |
Two Lines |
735 |
Three Lines |
736 |
2nd Line Format |
737 |
Set no. of decimal places for 2nd line of measuring page.
(C5.6.9) |
738 |
#X. |
739 |
#X.X |
740 |
#X.XX |
741 |
#X.XXX |
742 |
#X.XXXX |
743 |
#X.XXXXX |
744 |
#X.XXXXXX |
745 |
#X.XXXXXXX |
746 |
#X.XXXXXXXX |
747 |
3rd Line Format |
748 |
Set no. of decimal places for 3rd line of measuring page.
(C5.6.11) |
749 |
Set damping for 1st line of measuring page.
(C5.7.6) |
750 |
Set number of lines of display on measuring page.
(C5.7.1) |
751 |
Set no. of decimal places for 2nd line of measuring page.
(C5.7.4/9) |
752 |
Set no. of decimal places for 3rd line of measuring page.
(C5.7.6/11) |
753 |
Current Span |
754 |
Selection of current output span.
(C2.2.6) |
755 |
4-20 mA |
756 |
0-20 mA |
757 |
Custom |
758 |
Selection of current output span.
(C2.3.6) |
759 |
Selection of current output span.
(C2.4.6) |
760 |
Mode |
761 |
Maintenance Required |
762 |
Flow Polarity |
763 |
Flow Over Range |
764 |
Totaliser 1 Preset |
765 |
Totaliser 2 Preset |
766 |
Totaliser 3 Preset |
767 |
Output B |
768 |
Output D |
769 |
Set mode for status output.
(C2.5.1) |
770 |
Output C |
771 |
Set mode for status output.
(C2.2.1) |
772 |
Set mode for status output.
(C2.3.1) |
773 |
1st Line Format |
774 |
Set no. of decimal places for 1st line of measuring page.
(C5.6.7) |
775 |
Set no. of decimal places for 1st line of measuring page.
(C5.7.7) |
776 |
Set no. of decimal places for 1st line of measuring page.
(C5.7.2/7) |
777 |
Default Display |
778 |
Set default page of display on reset.
(C5.5) |
779 |
None |
780 |
1st Meas. Page |
781 |
2nd Meas. Page |
782 |
Status Page |
783 |
Graphic Page |
784 |
Optical Keys |
785 |
Turn optical keys on/off.
(C5.3) |
786 |
Backlight |
787 |
Configure backlight.
(C5.4) |
788 |
White |
789 |
Red - Failure |
790 |
NE107 Color |
791 |
Set action for control input A.
(C2.3.1) |
792 |
Hold All Outputs |
793 |
Hold Output A |
794 |
Hold Output C |
795 |
Hold Output D |
796 |
All Outputs To Zero |
797 |
Output A To Zero |
798 |
Output C To Zero |
799 |
Output D To Zero |
800 |
Reset All Totalisers |
801 |
Reset Totaliser 1 |
802 |
Reset Totaliser 2 |
803 |
Stop All Totalisers |
804 |
Stop Totaliser 1 |
805 |
Stop Totaliser 2 |
806 |
Zero Outp.+Stop Tot. |
807 |
Error Reset |
808 |
Calibrate Zero |
809 |
Set action for control input A.
(C2.2.1) |
810 |
Hold Output B |
811 |
Output B To Zero |
812 |
IO2 |
813 |
Display IO |
814 |
SIL IO |
815 |
Profi.DP |
816 |
Profi.PA |
817 |
Foundation H1 |
818 |
Quick Access |
819 |
Configure quick access function.
(C6.4.2) |
820 |
Reset all Totalisers |
821 |
Reset Totaliser 3 |
822 |
Measurement |
823 |
Selection of measurement for output.
Set TV.
(C2.2.1, C4.4.3.1) |
824 |
Concentration 1 |
825 |
Concentration 2 |
826 |
Conc. mass flow 1 |
827 |
Conc. volume flow 1 |
828 |
Conc. mass flow 2 |
829 |
Conc. volume flow 2 |
830 |
Range Min |
831 |
Set measurement value range for output.
(C2.2.2) |
832 |
Range Max |
833 |
LS Threshold |
834 |
LS Hysteresis |
835 |
Selection of measurement for output.
(C2.2.1) |
836 |
Value Per Pulse |
837 |
Set low flow cutoff for output.
(C2.2.4) |
838 |
Set measurement for totaliser.
(C3.1.2) |
839 |
Preset Value |
840 |
Preset value for totaliser. |
841 |
Set low flow cutoff for totaliser. |
842 |
Selection of measurement for output.
Set 4V.
(C2.3.1, C4.4.4.1) |
843 |
Set measurement value range for output.
(C2.3.2) |
844 |
Selection of measurement for output.
(C2.3.1) |
845 |
Set low flow cutoff for output.
(C2.5.4) |
846 |
Measurement C |
847 |
Selection of measurement for output C.
Display PV (current output C).
(A3.2, C2.4.1, C4.4.1.1, C7.1.2) |
848 |
Selection of measurement for output.
Set SV.
(C2.5.1, C4.4.2.1) |
849 |
Set measurement value range for output.
(C2.5.2) |
850 |
Selection of measurement for output.
(C2.5.1) |
851 |
Set measurement for totaliser.
(C3.2.2) |
852 |
Set measurement for totaliser.
(C3.3.2) |
853 |
1st Line Variable |
854 |
Set Measurement for 1st line of measuring page.
(C5.6.2) |
855 |
Set Range for 1st line of measuring page.
(C5.6.3) |
856 |
Set Measurement for 1st line of measuring page.
(C5.7.2) |
857 |
Set Range for 1st line of measuring page.
(C5.7.3) |
858 |
2nd Line Variable |
859 |
Set measurement for 2nd line of measuring page.
(C5.6.8) |
860 |
Totaliser 1 Mass |
861 |
Totaliser 1 Volume |
862 |
Totaliser 2 Mass |
863 |
Totaliser 2 Volume |
864 |
Totaliser 3 Mass |
865 |
Totaliser 3 Volume |
866 |
Bargraph |
867 |
3rd Line Variable |
868 |
Set measurement for 3rd line of measuring page.
(C5.6.10) |
869 |
Set measurement for 2nd line of measuring page.
(C5.7.8) |
870 |
Set measurement for 3rd line of measuring page.
(C5.7.10) |
871 |
Operation Mode |
872 |
Sets the operating mode.
(A8) |
873 |
Measuring |
874 |
Standby |
875 |
Stop |
876 |
5.3f |
877 |
Temp. At Zero Cal. |
878 |
DCF1 |
879 |
Empty |
880 |
Pure Water |
881 |
Town Water |
882 |
Other |
883 |
DCF2 |
884 |
DCF3 |
885 |
DCF4 |
886 |
DCF5 |
887 |
Zero Add. Offset |
888 |
Set additional zero offset for mass flow. |
889 |
DCF6 |
890 |
DCF7 |
891 |
DCF8 |
892 |
1 Point Calibration |
893 |
2nd Calibration Point |
894 |
Factory Calibration |
895 |
Cancel |
896 |
Density Calib. Product |
897 |
Standard Density k0 |
898 |
Set k0 value for Standard density.
(C1.2.7) |
899 |
0.7f |
900 |
Standard Density k1 |
901 |
Set k1 value for Standard density.
(C1.2.8) |
902 |
Standard Density k2 |
903 |
Set k2 value for Standard density.
(C1.2.9) |
904 |
mm |
905 |
Density Mode |
906 |
Set Density Mode.
(C1.2.2) |
907 |
Process |
908 |
Referred |
909 |
Standard |
910 |
Fixed Density Value |
911 |
Set density value for Fixed Density. |
912 |
Ref. Density Temp. |
913 |
Set Reference Temperature for density. |
914 |
Ref. Density Slope |
915 |
Set Density Slope for referred density.
(C1.2.5) |
916 |
Low Flow Cutoff |
917 |
Set the low flow cutoff in percent of nom. mass flow.
(C1.1.6) |
918 |
Conc. Offset |
919 |
Set an additional offset for the 1st conc. measurement.
(C1.3.2.2) |
920 |
6.3f |
921 |
CCF01 |
922 |
Selects type of concentration measurement.
(C1.3.4.1) |
923 |
Linear |
924 |
Non Linear |
925 |
Conc. Product |
926 |
Set which 1st concentration product is displayed.
(C1.3.2.3) |
927 |
% Of Product A |
928 |
% Of Product B |
929 |
CCF02 |
930 |
Set density of product A in g/cm3.
(C1.3.4.2) |
931 |
CCF03 |
932 |
Set temperature coefficient for product A.
(C1.3.4.3) |
933 |
CCF04 |
934 |
Set temperature coefficient squared for product A.
(C1.3.4.4) |
935 |
CCF05 |
936 |
Set product B type.
(C1.3.4.5) |
937 |
CCF06 |
938 |
Set density of product B in g/cm3.
(C1.3.4.6) |
939 |
CCF07 |
940 |
Set temperature coefficient squared fo product B.
(C1.3.4.7) |
941 |
CCF08 |
942 |
Set parameters for non-linear equation.
(C1.3.4.8) |
943 |
CCF09 |
944 |
Set parameters for non-linear equation.
(C1.3.4.9) |
945 |
CCF10 |
946 |
Set parameters for non-linear equation.
(C1.3.4.10) |
947 |
CCF11 |
948 |
Set parameters for non-linear equation.
(C1.3.4.11) |
949 |
CCF12 |
950 |
Set parameters for non-linear equation.
(C1.3.4.12) |
951 |
Set an additional offset for the 2nd conc. measurement.
(C1.3.3.2) |
952 |
Selects type of concentration measurement.
(C1.3.5.1) |
953 |
Set which 2nd concentration product is displayed.
(C1.3.3.3) |
954 |
Set density of product A in g/cm3.
(C1.3.5.2) |
955 |
Set temperature coefficient for product A.
(C1.3.5.3) |
956 |
Set temperature coefficient squared for product A.
(C1.3.5.4) |
957 |
Set product B type.
(C1.3.5.5) |
958 |
Set density of product B in g/cm3.
(C1.3.5.6) |
959 |
Set temperature coefficient squared fo product B.
(C1.3.5.7) |
960 |
Set parameters for non-linear equation.
(C1.3.5.8) |
961 |
Set parameters for non-linear equation.
(C1.3.5.9) |
962 |
Set parameters for non-linear equation.
(C1.3.5.10) |
963 |
Set parameters for non-linear equation.
(C1.3.5.11) |
964 |
Set parameters for non-linear equation.
(C1.3.5.12) |
965 |
Conc. Data Sel. |
966 |
Select the active concentration.
(C1.3.1) |
967 |
Conc. Data 1 |
968 |
Conc. Data 2 |
969 |
Pipe Diameter |
970 |
Set pipe diameter used to calculate flow velocity. |
971 |
5.2f |
972 |
Flow Correction |
973 |
Set additional correction for mass flow.
(C1.1.3) |
974 |
Flow Direction |
975 |
Set the direction of flow in relation to the arrow on the sensor.
(A3.2/8, C1.1.4, C7.1.8) |
976 |
Forwards |
977 |
Backwards |
978 |
Press. Supp. Time |
979 |
Set the time that pressure suppression is active.
(C1.1.8) |
980 |
Press. Supp. Cutoff |
981 |
Set the additional cutoff used during pressure suppression.
(C1.1.7) |
982 |
Set the function of system control.
(C1.4.1) |
983 |
No Action |
984 |
Flow = 0 |
985 |
Condition |
986 |
Set the condition for activating the system control.
(C1.4.2) |
987 |
Max. Density |
988 |
Set the upper limit for condition selected by sys. contrl. cond. |
989 |
Max. Temperature |
990 |
Min. Density |
991 |
Set the lower limit for condition selected by sys. contrl. cond. |
992 |
Min. Temperature |
993 |
Density configuration enabled |
994 |
Max. Allowed Temp. |
995 |
Min. Allowed Temp. |
996 |
CF1 |
997 |
CF2 |
998 |
CF3 |
999 |
CF4 |
1000 |
CF5 |
1001 |
CF6 |
1002 |
CF7 |
1003 |
CF8 |
1004 |
CF11 |
1005 |
CF12 |
1006 |
CF13 |
1007 |
CF14 |
1008 |
CF15 |
1009 |
CF16 |
1010 |
CF17 |
1011 |
CF18 |
1012 |
CF19 |
1013 |
CF20 |
1014 |
CF21 |
1015 |
CF22 |
1016 |
CF23 |
1017 |
CF24 |
1018 |
CF25 |
1019 |
CF26 |
1020 |
CF27 |
1021 |
Tube Amplitude |
1022 |
CF5 Error |
1023 |
Empty Density |
1024 |
Process Noise Damping |
1025 |
Set process noise damping.
(C1.1.5) |
1026 |
4.2f |
1027 |
Zero Calib. Duration |
1028 |
2 Phase Threshold |
1029 |
Set the threshold for activation of 2-phase signal status message.
(C1.5.1, C7.1.10) |
1030 |
5.1f |
1031 |
2 Ph. Ref. Level |
1032 |
Range |
1033 |
Set pulse value for pulse output.
(C2.2.3) |
1034 |
Threshold |
1035 |
Set threshold value for limit switch.
Selection of measurement for output.
(C2.2.2) |
1036 |
Set pulse value for pulse output.
(C2.3.3) |
1037 |
Set low flow cutoff for output.
(C2.3.4) |
1038 |
Set threshold value for limit switch.
(C2.3.2) |
1039 |
Set measurement value range for output.
(A3.3, C2.4.2, C7.1.3) |
1040 |
Set threshold value for limit switch.
(C2.4.2) |
1041 |
Set pulse value for pulse output.
(C2.5.3) |
1042 |
Set threshold value for limit switch.
(C2.5.2) |
1043 |
Preset value for totaliser.
(C3.1.5) |
1044 |
Set low flow cutoff for totaliser.
(C3.1.3) |
1045 |
Preset value for totaliser.
(C3.2.5) |
1046 |
Set low flow cutoff for totaliser.
(C3.2.3) |
1047 |
Preset value for totaliser.
(C3.3.5) |
1048 |
Set low flow cutoff for totaliser.
(C3.3.3) |
1049 |
Set scaling for graphic page Y-axis.
(C5.8.2) |
1050 |
Extended Range |
1051 |
Threshold |
1052 |
Set threshold value for range change setting for current output.
(C2.2.12) |
1053 |
Range 0%...100% |
1054 |
Limitation |
1055 |
Set Min/Max for 1st line of measuring page.
(C5.6.4) |
1056 |
Low flow cutoff for 1st line of measuring page.
(C5.6.5) |
1057 |
Set Min/Max for 1st line of measuring page.
(C5.7.4) |
1058 |
Low flow cutoff for 1st line of measuring page.
(C5.7.5) |
1059 |
Set additional zero offset for mass flow.
(C1.1.2) |
1060 |
Product Density Value |
1061 |
Set density value for Fixed Density.
(C1.2.1/3) |
1062 |
Set Reference Temperature for density.
(C1.2.4/6) |
1063 |
Set pipe diameter used to calculate flow velocity.
(C1.1.9) |
1064 |
Set the upper limit for condition selected by sys. contrl. cond.
(C1.4.3) |
1065 |
Set the lower limit for condition selected by sys. contrl. cond.
(C1.4.4) |
1066 |
gdc_04100_32_Hart0PctTo100PctCurrentA |
1067 |
gdc_04102_32_HartMinMaxCurrentA |
1068 |
gdc_04104_32_HartErrorCurrentA |
1069 |
gdc_04110_32_Hart0PctTo100PctCurrentB |
1070 |
gdc_04112_32_HartMinMaxCurrentB |
1071 |
gdc_04114_32_HartErrorCurrentB |
1072 |
gdc_04120_32_Hart0PctTo100PctCurrentC |
1073 |
gdc_04122_32_HartMinMaxCurrentC |
1074 |
gdc_04124_32_HartErrorCurrentC |
1075 |
flResponseTimeGdcDelayed |
1076 |
ui16ObjectNumberGdcGeneric |
1077 |
uiSubNumberGdcGeneric |
1078 |
uniPlaceholderGdc |
1079 |
uiCountBytesGdcTg |
1080 |
uiSubNumberGdcTg |
1081 |
ui16ObjectNumberGdcTg |
1082 |
uiControlStatusGdcTg |
1083 |
ui16ObjectNumberGdcDelayed |
1084 |
uiSubNumberGdcDelayed |
1085 |
uiGdcDelayed1 |
1086 |
uiGdcDelayed2 |
1087 |
uiGdcDelayed3 |
1088 |
uiGdcDelayed4 |
1089 |
uiGdcDelayed5 |
1090 |
uiGdcDelayed6 |
1091 |
uiGdcDelayed7 |
1092 |
uiGdcDelayed8 |
1093 |
uiGdcDelayed9 |
1094 |
uiGdcDelayed10 |
1095 |
uiGdcDelayed11 |
1096 |
uiGdcDelayed12 |
1097 |
uiGdcDelayed13 |
1098 |
uiGdcDelayed14 |
1099 |
uiGdcDelayed15 |
1100 |
uiGdcDelayed16 |
1101 |
uiGdcDelayed17 |
1102 |
uiGdcDelayed18 |
1103 |
uiGdcDelayed19 |
1104 |
uiGdcDelayed20 |
1105 |
ui16GdcDelayedWord1 |
1106 |
ui16GdcDelayedWord2 |
1107 |
ui16GdcDelayedWord3 |
1108 |
ui16GdcDelayedWord4 |
1109 |
ui16GdcDelayedWord5 |
1110 |
ui16GdcDelayedWord6 |
1111 |
ui16GdcDelayedWord7 |
1112 |
ui16GdcDelayedWord8 |
1113 |
ui16GdcDelayedWord9 |
1114 |
ui16GdcDelayedWord10 |
1115 |
flGdcDelayed1 |
1116 |
flGdcDelayed2 |
1117 |
flGdcDelayed3 |
1118 |
flGdcDelayed4 |
1119 |
flGdcDelayed5 |
1120 |
uiGdcByteGenericRead1 |
1121 |
uiGdcByteGenericRead2 |
1122 |
uiGdcByteGenericRead3 |
1123 |
uiGdcByteGenericRead4 |
1124 |
uiGdcByteGenericRead5 |
1125 |
uiGdcByteGenericRead6 |
1126 |
uiGdcByteGenericRead7 |
1127 |
uiGdcByteGenericRead8 |
1128 |
uiGdcByteGenericRead9 |
1129 |
uiGdcByteGenericRead10 |
1130 |
uiGdcByteGenericRead11 |
1131 |
uiGdcByteGenericRead12 |
1132 |
uiGdcByteGenericRead13 |
1133 |
uiGdcByteGenericRead14 |
1134 |
uiGdcByteGenericRead15 |
1135 |
uiGdcByteGenericRead16 |
1136 |
uiGdcByteGenericRead17 |
1137 |
uiGdcByteGenericRead18 |
1138 |
uiGdcByteGenericRead19 |
1139 |
uiGdcByteGenericRead20 |
1140 |
uiGdcByteGenericRead21 |
1141 |
uiGdcByteGenericRead22 |
1142 |
uiGdcByteGenericRead23 |
1143 |
uiGdcByteGenericRead24 |
1144 |
uiGdcByteGenericRead25 |
1145 |
uiGdcByteGenericRead26 |
1146 |
uiGdcByteGenericRead27 |
1147 |
uiGdcByteGenericRead28 |
1148 |
uiGdcByteGenericRead29 |
1149 |
uiGdcByteGenericRead30 |
1150 |
uiGdcByteGenericWrite1 |
1151 |
uiGdcByteGenericWrite2 |
1152 |
uiGdcByteGenericWrite3 |
1153 |
uiGdcByteGenericWrite4 |
1154 |
uiGdcByteGenericWrite5 |
1155 |
uiGdcByteGenericWrite6 |
1156 |
uiGdcByteGenericWrite7 |
1157 |
uiGdcByteGenericWrite8 |
1158 |
uiGdcByteGenericWrite9 |
1159 |
uiGdcByteGenericWrite10 |
1160 |
uiGdcByteGenericWrite11 |
1161 |
uiGdcByteGenericWrite12 |
1162 |
uiGdcByteGenericWrite13 |
1163 |
uiGdcByteGenericWrite14 |
1164 |
uiGdcByteGenericWrite15 |
1165 |
uiGdcByteGenericWrite16 |
1166 |
uiGdcByteGenericWrite17 |
1167 |
uiGdcByteGenericWrite18 |
1168 |
uiGdcByteGenericWrite19 |
1169 |
uiGdcByteGenericWrite20 |
1170 |
uiGdcByteGenericWrite21 |
1171 |
uiGdcByteGenericWrite22 |
1172 |
uiGdcByteGenericWrite23 |
1173 |
uiGdcByteGenericWrite24 |
1174 |
uiGdcByteGenericWrite25 |
1175 |
uiGdcByteGenericWrite26 |
1176 |
uiGdcByteGenericWrite27 |
1177 |
uiGdcByteGenericWrite28 |
1178 |
uiGdcByteGenericWrite29 |
1179 |
uiGdcByteGenericWrite30 |
1180 |
ui16GdcWordGenericRead1 |
1181 |
ui16GdcWordGenericRead2 |
1182 |
ui16GdcWordGenericRead3 |
1183 |
ui16GdcWordGenericRead4 |
1184 |
ui16GdcWordGenericRead5 |
1185 |
ui16GdcWordGenericRead6 |
1186 |
ui16GdcWordGenericRead7 |
1187 |
ui16GdcWordGenericRead8 |
1188 |
ui16GdcWordGenericRead9 |
1189 |
ui16GdcWordGenericRead10 |
1190 |
ui16GdcWordGenericWrite1 |
1191 |
ui16GdcWordGenericWrite2 |
1192 |
ui16GdcWordGenericWrite3 |
1193 |
ui16GdcWordGenericWrite4 |
1194 |
ui16GdcWordGenericWrite5 |
1195 |
ui16GdcWordGenericWrite6 |
1196 |
ui16GdcWordGenericWrite7 |
1197 |
ui16GdcWordGenericWrite8 |
1198 |
ui16GdcWordGenericWrite9 |
1199 |
flGdcFloatGenericRead1 |
1200 |
flGdcFloatGenericRead2 |
1201 |
flGdcFloatGenericRead3 |
1202 |
flGdcFloatGenericRead4 |
1203 |
flGdcFloatGenericRead5 |
1204 |
flGdcFloatGenericWrite1 |
1205 |
flGdcFloatGenericWrite2 |
1206 |
flGdcFloatGenericWrite3 |
1207 |
flGdcFloatGenericWrite4 |
1208 |
ui32GdcUlongGenericRead1 |
1209 |
ui32GdcUlongGenericRead2 |
1210 |
ui32GdcUlongGenericRead3 |
1211 |
ui32GdcUlongGenericRead4 |
1212 |
ui32GdcUlongGenericRead5 |
1213 |
ui32GdcUlongGenericWrite1 |
1214 |
ui32GdcUlongGenericWrite2 |
1215 |
ui32GdcUlongGenericWrite3 |
1216 |
ui32GdcUlongGenericWrite4 |
1217 |
Online Mode? |
1218 |
Can the Host Application currently communicate with the field device? |
1219 |
yes |
1220 |
no |
1221 |
Data type |
1222 |
Byte |
1223 |
Word |
1224 |
Float |
1225 |
Unsigned Long |
1226 |
lblmthEnableConcentraton |
1227 |
hlpmthEnableConcentraton |
1228 |
Select module |
1229 |
Sensor Electronics |
1230 |
Main SW Version |
1231 |
Electronic Revision |
1232 |
UI SW Version |
1233 |
Ident no. |
1234 |
Hardware id |
1235 |
Software version |
1236 |
Production date |
1237 |
Calibration date |
1238 |
Board ser.no. |
1239 |
Stop All Simulations |
1240 |
Stop all running simulation functions.
(A2.2, B3.1) |
1241 |
Set simulated value for volume flow.
(B3.3) |
1242 |
Limit Switch B |
1243 |
Sets simulated value of output on Terminal B.
(B3.8) |
1244 |
Limit Switch D |
1245 |
Sets simulated value of output on Terminal D.
(B3.10) |
1246 |
Control Input B |
1247 |
Pulse Output D |
1248 |
Status Output B |
1249 |
Set simulated value for mass flow.
(B3.2) |
1250 |
Control Input A |
1251 |
Sets simulated value of output on Terminal A.
(B3.7) |
1252 |
Freq. Output D |
1253 |
Pulse Output A |
1254 |
Limit Switch A |
1255 |
Freq. Output A |
1256 |
Set simulated value for density.
(B3.4) |
1257 |
Pulse Output B |
1258 |
Set simulated value for temperature.
(B3.5) |
1259 |
Current Out A |
1260 |
Status Output D |
1261 |
Current Out B |
1262 |
Current Out C |
1263 |
Sets simulated value of output on Terminal C.
(B3.9) |
1264 |
Status Output A |
1265 |
Freq. Output B |
1266 |
Show parameters |
1267 |
Select: Show always all parameters or only those actually valid.
For debugging purposes only. |
1268 |
only valid |
1269 |
all |
1270 |
8.3f |
1271 |
Analog value |
1272 |
Characteristics of the Analog Channel. Analog input or output. |
1273 |
gtu_63049_68 |
1274 |
Access level |
1275 |
User |
1276 |
Operator |
1277 |
Expert |
1278 |
Service |
1279 |
Password |
1280 |
Password for Access level |
1281 |
No Unit |
1282 |
Unit not used |
1283 |
Resistance |
1284 |
Unit s |
1285 |
lbluniHourGdc |
1286 |
Percent |
1287 |
Reset Errors |
1288 |
Reset errors.
(A2.1, C6.2) |
1289 |
Reset Access Level |
1290 |
Reset granted Access Level |
1291 |
Set Access Level |
1292 |
Enable Expert Mode |
1293 |
Disable Expert Mode |
1294 |
Perform Warmstart |
1295 |
Information |
1296 |
Degrees Brix |
1297 |
°Bm144 |
1298 |
Degrees Baume 144 |
1299 |
°Bm145 |
1300 |
Degrees Baume 145 |
1301 |
Percent Plato |
1302 |
Degrees API |
1303 |
AbmLeaveZeroCalibration |
1304 |
Perform Zero calibration/ display current zero calib. value.
(A7, C1.1.1, C7.1.9) |
1305 |
Calibrate Density |
1306 |
Perform density calibration.
(C1.2.1) |
1307 |
Status Bit Not Supported |
1308 |
No Effect |
1309 |
Maintenance Required |
1310 |
Failure |
1311 |
Out of Specification |
1312 |
Function Check |
1313 |
Disabled |
1314 |
Enabled |
1315 |
Reset |
1316 |
Set |
1317 |
Used to map a status condition to a severity level. |
1318 |
PV Analog Channel Saturated |
1319 |
PV Analog Channel Fixed |
1320 |
Critical Power Failure |
1321 |
Failure |
1322 |
Out of Specification |
1323 |
Function Check |
1324 |
Simulation active |
1325 |
Non-Volatile memory failure |
1326 |
Volatile memory error |
1327 |
Watchdog reset executed |
1328 |
Power supply conditions out of range |
1329 |
Environmental conditions out of range |
1330 |
Electronic failure |
1331 |
Device configuration locked |
1332 |
Status simulation active |
1333 |
Discrete Variable Simulation active |
1334 |
Event Notification Overflow |
1335 |
Secondary Analog Channel Saturated |
1336 |
Tertiary Analog Channel Saturated |
1337 |
Quaternary Analog Channel Saturated |
1338 |
Quinary Analog Channel Saturated |
1339 |
Subdevice list changed |
1340 |
Duplicate master detected |
1341 |
Sub-device mismatch |
1342 |
Sub-devices with duplicate IDs found |
1343 |
Stale data notice |
1344 |
Capacity Denied |
1345 |
Bandwidth allocation pending |
1346 |
Block transfer pending |
1347 |
Radio failure |
1348 |
Secondary Analog Channel Fixed |
1349 |
Tertiary Analog Channel Fixed |
1350 |
Quaternary Analog Channel Fixed |
1351 |
Quinary Analog Channel Fixed |
1352 |
Condensed status simulation |
1353 |
Allows simulation of different status conditions. |
1354 |
Condensed status value |
1355 |
Starting Status Map Index must be even value. |
1356 |
Bit Index |
1357 |
Reset Condensed Status Map |
1358 |
Show single events |
1359 |
On occurence |
1360 |
Always |
1361 |
Never |
1362 |
Optical Interf. Active |
1363 |
Keys can be used 60 sec. after removal of optical interface. |
1364 |
Disp. 2 Overrange |
1365 |
Check configuration settings of display line 2. |
1366 |
Status Out C Active |
1367 |
No action required. |
1368 |
Status Out B Active |
1369 |
Status Out A Active |
1370 |
Control In B Active |
1371 |
Control In A Active |
1372 |
Disp. 1 Overrange |
1373 |
Check configuration settings of display line 1. |
1374 |
Tot 3 Stopped |
1375 |
Tot 2 Stopped |
1376 |
Tot 1 Stopped |
1377 |
Zero Calibr. Running |
1378 |
Safe Operation |
1379 |
Status Out D Active |
1380 |
Disp. 2 No Meas. Values |
1381 |
Select another measuement for meas. page 2. |
1382 |
Disp. 1 No Meas. Values |
1383 |
Select another measuement for meas. page 1. |
1384 |
Tot 3 No Meas. Values |
1385 |
Select another measuement for tot 3 or activate diagnosis meas. |
1386 |
Tot 2 No Meas. Values |
1387 |
Select another measuement for tot 2 or activate diagnosis meas. |
1388 |
Tot 1 No Meas. Values |
1389 |
Select another measuement for tot 1 or activate diagnosis meas. |
1390 |
IO D No Meas. Values |
1391 |
Select another measuement for IO D or activate diagnosis meas. |
1392 |
IO C No Meas. Values |
1393 |
Select another measuement for IO C or activate diagnosis meas. |
1394 |
IO B No Meas. Values |
1395 |
Select another measuement for IO B or activate diagnosis meas. |
1396 |
IO A No Meas. Values |
1397 |
Select another measuement for IO A or activate diagnosis meas. |
1398 |
Tot 3 Power Failure |
1399 |
Check totaliser value and perform reset errors. |
1400 |
Tot 2 Power Failure |
1401 |
Tot 1 Power Failure |
1402 |
System Control Active |
1403 |
Tot 3 Overflow |
1404 |
Check totaliser format. |
1405 |
Tot 2 Overflow |
1406 |
Tot 1 Overflow |
1407 |
Sensor Signal Low |
1408 |
Check for entrained gas or viscosity of product. |
1409 |
2 Phase Flow Detected |
1410 |
Check process for entrained gas. |
1411 |
Sensor Signal Search |
1412 |
Check process conditions. In case of remote sensor check cabling. |
1413 |
IO C Connection |
1414 |
Check connection at terminal C, reduce load and perform reset errors. |
1415 |
IO B Connection |
1416 |
Check cable and connection at terminal B, reduce load. |
1417 |
IO A Connection |
1418 |
Check cable and connection at terminal A, reduce load. |
1419 |
Backup 2 Data Faulty |
1420 |
Save settings to Backup 2. |
1421 |
Backup 1 Data Faulty |
1422 |
Save settings to Backup 1. |
1423 |
Backplane Difference |
1424 |
Update backplane by changing and storing one parameter. |
1425 |
Factory Data Faulty |
1426 |
Please contact KROHNE. |
1427 |
Backplane Data Faulty |
1428 |
Check if converter is correctly mounted and fixed into housing. |
1429 |
Velocity Out of Range |
1430 |
Check process conditions or pipe diameter setting. |
1431 |
Prod.Density Out of Range |
1432 |
Check process conditions and density calibration. |
1433 |
Flow Out of Range |
1434 |
Check process conditions. |
1435 |
Proc.Temp.Out of Range |
1436 |
IO D Overrange |
1437 |
Check the range settings of the related output. |
1438 |
IO C Overrange |
1439 |
IO B Overrange |
1440 |
IO A Overrange |
1441 |
Electr.Temp.Out of Spec |
1442 |
Protect electronics from heat by process or direct sunlight. |
1443 |
I/O Temp. Out of Spec |
1444 |
Temp. Or Strain Res. Def. |
1445 |
Check cabling in case of remote device or replace sensor. |
1446 |
IO D Simulation Active |
1447 |
Turn off simulation mode. |
1448 |
IO A Simulation Active |
1449 |
Sensor Starting up |
1450 |
Sensor Simulation Active |
1451 |
Sensor in Standby Mode |
1452 |
For normal operation change operation mode to measurement mode. |
1453 |
Sensor in Stop Mode |
1454 |
IO C Simulation Active |
1455 |
IO B Simulation Active |
1456 |
IO D Configuration |
1457 |
Check terminal D configuration or reset to factory configuration. |
1458 |
IO C Configuration |
1459 |
Check terminal C configuration or reset to factory configuration. |
1460 |
IO2 Configuration |
1461 |
Check IO2 configuration or reset to factory configuration. |
1462 |
IO1 Configuration |
1463 |
Check IO1 configuration or reset to factory configuration. |
1464 |
Display Config. |
1465 |
Check display configuration or reset to factory configuration. |
1466 |
Lock Jumper Set |
1467 |
Remove the lock jumper from the device. |
1468 |
IO B Configuration |
1469 |
Check terminal B configuration or reset to factory configuration. |
1470 |
IO C Calibration Invalid |
1471 |
Perform power reset. If the status returns, contact KROHNE. |
1472 |
Safe Conf. Unverif. (S) |
1473 |
Set safety mode, perform safe config. according to safety manual. |
1474 |
Density Calibration |
1475 |
Check config. of the related function. Reset config. to factory. |
1476 |
Process Input Config. |
1477 |
Safe Config. Invalid |
1478 |
Reset to factory configuration. |
1479 |
Safe Conf. Unverif. (IO) |
1480 |
DM Configuration |
1481 |
BM Configuration |
1482 |
IO A Configuration |
1483 |
Check terminal A configuration or reset to factory configuration. |
1484 |
Tot 3 Configuration |
1485 |
Check Tot. 3 configuration or reset to factory configuration. |
1486 |
Tot 2 Configuration |
1487 |
Check Tot. 2 configuration or reset to factory configuration. |
1488 |
Tot 1 Configuration |
1489 |
Check Tot. 1 configuration or reset to factory configuration. |
1490 |
IO C Failure |
1491 |
Perform power reset, reset errors. If the status returns, contact KROHNE. |
1492 |
IO B Failure |
1493 |
IO A Failure |
1494 |
Process Input Failure |
1495 |
Int. Comm. Error IO B |
1496 |
Safety Rel. Failure |
1497 |
Additional messages describe safety relevant failures. |
1498 |
DM Failure |
1499 |
BM Failure |
1500 |
HW Combination Error |
1501 |
Int. Comm. Error IO C |
1502 |
Tot 3 Failure |
1503 |
Int. Comm. Error IO A |
1504 |
Int. Comm. Error |
1505 |
Tot 2 Failure |
1506 |
Tot 1 Failure |
1507 |
IO 2 Failure |
1508 |
IO 1 Failure |
1509 |
Sensor Error |
1510 |
Sensor Containment Dam. |
1511 |
Replace sensor. |
1512 |
Reset to default |
1513 |
Reset the mappings to the Condensed Status to default values. |
1514 |
Set Simulation Bits |
1515 |
(De)activates the selected Simulation bits |
1516 |
Enable/disable Status Simulation |
1517 |
Enable/disable status simulation. Status simulation will only affect the HART Interface and the content of Command #48. The status of the device is not changed. |
1518 |
Reset all Totalisers |
1519 |
Reset all Totalisers
(Func. A2.3) |
1520 |
Set measurement |
1521 |
Start Totaliser |
1522 |
Start totaliser after it has bee.
(C3.1.9) |
1523 |
Stop Totaliser |
1524 |
Stop totaliser and holds current.
(C3.1.8) |
1525 |
Set Totaliser |
1526 |
Set totaliser to desired value.
(C3.1.7) |
1527 |
Reset Totaliser 1 |
1528 |
Reset totaliser.
(A2.4, C3.1.6, E) |
1529 |
Information
(Func. C3.1.10) |
1530 |
Start totaliser after it has bee.
(C3.2.9) |
1531 |
Stop totaliser and holds current.
(C3.2.8) |
1532 |
Set totaliser to desired value.
(C3.2.7) |
1533 |
Reset Totaliser 2 |
1534 |
Reset totaliser.
(A2.5, C3.2.6, E) |
1535 |
Information
(Func. C3.2.10) |
1536 |
Start totaliser after it has bee.
(C3.3.9) |
1537 |
Stop totaliser and holds current.
(C3.3.8) |
1538 |
Set totaliser to desired value.
(C3.3.7) |
1539 |
Reset Totaliser 3 |
1540 |
Reset totaliser.
(A2.6, C3.3.6, E) |
1541 |
Information
(Func. C3.3.10) |
1542 |
No Unit |
1543 |
Unit classification |
1544 |
Invalid transaction number |
1545 |
Value was too high |
1546 |
Value was too low |
1547 |
Invalid classification |
1548 |
Invalid units |
1549 |
Invalid device variable code |
1550 |
GDC timeout |
1551 |
GDC error |
1552 |
GDC delayed response |
1553 |
passed_parameter_too_large |
1554 |
passed_parameter_too_small |
1555 |
in_writer_protect_mode |
1556 |
Waiting for GDC delayed response |
1557 |
C number undefined |
1558 |
Invalid object number |
1559 |
SIL |
1560 |
General Sil Setup |
1561 |
Configuration |
1562 |
Electr. Information |
1563 |
Sensor Information |
1564 |
Density Calibration |
1565 |
Flow Calibration |
1566 |
Display |
1567 |
General |
1568 |
Bar graph |
1569 |
Bar graph menu.
Displays the process variable as a bar graph. |
1570 |
Trend |
1571 |
Trend menu.
Displays the trend of the process variable. |
1572 |
Chart |
1573 |
Chart menu.
Provides graphical display of the process variable. |
1574 |
PV Output |
1575 |
Bar graph menu.
Displays the analog signal as a bar graph. |
1576 |
Trend menu.
Displays the trend of the analog signal. |
1577 |
Chart menu.
Provides graphical display of the analog signal. |
1578 |
PV Analog Channel |
1579 |
Primary |
1580 |
HART Primary Variable (PV), the first element of the Dynamic Variables Array.
Equivalent to the process value of the current output. |
1581 |
SV Output |
1582 |
SV output value |
1583 |
SV Analog Channel |
1584 |
Secondary |
1585 |
HART Secondary Variable (SV), the second element of the Dynamic Variables Array.
Equivalent to the process value of the frequency output if available. |
1586 |
TV Output |
1587 |
TV output value |
1588 |
TV Analog Channel |
1589 |
Tertiary |
1590 |
HART Tertiary Variable (TV), the third element of the Dynamic Variables Array.
Equivalent to the process value of the current input if available. |
1591 |
QV Output |
1592 |
QV output value |
1593 |
QV Analog Channel |
1594 |
Quaternary |
1595 |
HART Quaternary Variable (QV), the fourth element of the Dynamic Variables Array.
Not related to any physical in-/output. |
1596 |
Time and simulation |
1597 |
Show unsupported |
1598 |
Show currently not supported process values. |
1599 |
Hide |
1600 |
Show |
1601 |
Measured Values |
1602 |
Process Variables |
1603 |
Simulation Values |
1604 |
Sensor Limits |
1605 |
Totalizer |
1606 |
Diagnosis Values |
1607 |
In-/Outputs, HART Dynamic Variables |
1608 |
In-/Outputs (Chart) |
1609 |
In-/Output (Bar) |
1610 |
In-/Output (Scope) |
1611 |
Measured Values (Chart) |
1612 |
Measured Values (Bar) |
1613 |
Measured Values (Scope) |
1614 |
Diagnosis Values (Chart) |
1615 |
Diagnosis Values (Bar) |
1616 |
Diagnosis Values (Scope) |
1617 |
Concentration Values (Chart) |
1618 |
Concentration Values (Bar) |
1619 |
Concentration Values (Scope) |
1620 |
HART |
1621 |
I/O HART |
1622 |
Mapping of Variables |
1623 |
Set the Mapping of Variables |
1624 |
Preliminary content |
1625 |
The content of this menu is only preliminary |
1626 |
Off |
1627 |
Function switched off |
1628 |
No valid items |
1629 |
This menu contains no valid items. |
1630 |
Process Variables |
1631 |
Device Setup |
1632 |
Maintenance |
1633 |
Offline |
1634 |
<Image> Manufacturer |
1635 |
<Image> Device |
1636 |
<Image> Process Input Orientation |
1637 |
<Image> Sensor Orientation |
1638 |
<Image> PI Calibration Orientation |
1639 |
<Image> PI Filter Orientation |
1640 |
<Image> PI Selftest Orientation |
1641 |
<Image> Current Output Orientation |
1642 |
<Image> Binary Output Orientation |
1643 |
<Image> Frequency Output Orientation |
1644 |
<Image> Status Output Orientation |
1645 |
<Image> Control Input Orientation |
1646 |
<Image> Totalizer Orientation |
1647 |
<Image> Selection IO Orientation |
1648 |
<Image> Display Orientation |
1649 |
<Image> HART Orientation |
1650 |
<Image> Diagnosis Active |
1651 |
<Image> Failure Status |
1652 |
<Image> Maintenance Required Status |
1653 |
<Image> Out Of Specification Status |
1654 |
<Image> Function Check Status |
1655 |
Quick Setup |
1656 |
Information |
1657 |
Setup |
1658 |
General |
1659 |
Reset |
1660 |
Identification |
1661 |
Device |
1662 |
Service |
1663 |
Simulation |
1664 |
HART analog channels |
1665 |
Identification & Info |
1666 |
Provides access to general parameters |
1667 |
Device info |
1668 |
HART Revisions |
1669 |
Preambles |
1670 |
General Status |
1671 |
Reset |
1672 |
lblmnuTestReset |
1673 |
Device |
1674 |
General |
1675 |
Config. Management |
1676 |
Special Functions |
1677 |
Units |
1678 |
Service Access |
1679 |
System |
1680 |
Service Param. |
1681 |
Service Info |
1682 |
I/O |
1683 |
Hardware |
1684 |
A |
1685 |
Terminal A (Off) |
1686 |
Terminal not available. |
1687 |
B |
1688 |
Terminal B (Off) |
1689 |
C |
1690 |
C (off) |
1691 |
Limit Switch C |
1692 |
Status Output C |
1693 |
D |
1694 |
D (off) |
1695 |
Actual Values |
1696 |
Simulation |
1697 |
Process Input |
1698 |
Flow |
1699 |
Concentration |
1700 |
System Control |
1701 |
Diagnostics |
1702 |
Device Status |
1703 |
Device Status menu.
Provides access to the current device status. |
1704 |
Condensed Status (NE 107) |
1705 |
Standard |
1706 |
Device Diagnostic Status 0 |
1707 |
Detail |
1708 |
Failure ('F') |
1709 |
Function Check ('C') |
1710 |
Out of Specification ('S') |
1711 |
Maintenance Required ('M') |
1712 |
Additional |
1713 |
Variable F/C/S/M |
1714 |
Device status simulation menu.
Provides access to simulation functions for the device status. |
1715 |
Select the Bits that should be simulated |
1716 |
Current Device Status |
1717 |
Shows the current Device Status |
1718 |
Status Mapping |
1719 |
Status mapping menu.
Provides access to the mapping of device status into the indicators of the HART condensed status according to NAMUR NE107. |
1720 |
Totalisers |
1721 |
Totaliser 1 |
1722 |
Operate |
1723 |
Totaliser 2 |
1724 |
Totaliser 3 |
1725 |
Prepare Parameter Download |
1726 |
Shall be performed prior to a complete parameter download to the device.
Writes some basic parameters to the device and performs a warm start. |
1727 |
finish parameter download |
1728 |
Should be performed after a complete parameter download to the device.
Performs a warm start. |
1729 |
Upload Variables |
1730 |
Download Variables |
1731 |
Common Tables |
1732 |
Interoperable * |
1733 |
Universal |
1734 |
Common Practice |
1735 |
Pressure Universal |
1736 |
Pressure Common |
1737 |
Menu |
1738 |
Rosemount Magflow |
1739 |
Rosemount Pressure |
1740 |
Moore Products |
1741 |
Siemens Pressure |
1742 |
P2 Common |
1743 |
Wireless |
1744 |
Munge |
1745 |
Analytical Oxygen/Combustion/Methane/CO |
1746 |
Flow Totalizer - Rate Indicator |
1747 |
Flow Variable Area |
1748 |
Flow Coriolis Mass |
1749 |
Flow Ultrasonic - Gas |
1750 |
Flow Ultrasonic - Liquid |
1751 |
Level Ultrasonic |
1752 |
Level Radar - Microwave |
1753 |
Pressure Absolute |
1754 |
Level Capacitance |
1755 |
Pressure Differential |
1756 |
Level Hydrostatic |
1757 |
Level |
1758 |
Pressure Absolute/Relative |
1759 |
Level Microwave |
1760 |
Level Radar |
1761 |
Level Density - Nuclear |
1762 |
Flow Electromagnetic |
1763 |
Flow Vortex |
1764 |
Flow Magmeter - Rack Version |
1765 |
Flow High Performance Magmeter |
1766 |
Flow Mass |
1767 |
Flow Ultrasonic |
1768 |
Flow Magnetic |
1769 |
Flow Magnetic - Custody Transfer |
1770 |
Flow 2-wire Magnetic |
1771 |
Flow Coriolis Mass - Custody Transfer |
1772 |
Flow 2-wire Vortex |
1773 |
Flow Thermal |
1774 |
Temperature Head Mounted |
1775 |
Temperature Compact |
1776 |
Temperature DIN Rail Mounted |
1777 |
Analytical pH |
1778 |
Analytical Conductivity - Conductive |
1779 |
Analytical Conductivity - Inductive |
1780 |
Temperature Sensor |
1781 |
Level Servo |
1782 |
Temperature DIN Rail |
1783 |
Temperature |
1784 |
Analytical ORP |
1785 |
Analytical pION |
1786 |
Analytical IConc |
1787 |
Analytical Electrode Conductivity |
1788 |
Analytical Toroidal Conductivity |
1789 |
Valve Positioner |
1790 |
Valve Controller |
1791 |
Pressure |
1792 |
Pressure Multivariable |
1793 |
Analytical pH/ORP |
1794 |
Flow Coriolis |
1795 |
Analytical Conductivity |
1796 |
Valve Positioner/Pneumatic |
1797 |
Valve Actuator - Electrical |
1798 |
Temperature Dual Input |
1799 |
Valve Actuator |
1800 |
Analytical Corrosion |
1801 |
Analytical Density - Nuclear |
1802 |
Level Continuous Gamma |
1803 |
Level Laser Ranging |
1804 |
Pressure Safety |
1805 |
Flow Vortex/Swirl |
1806 |
Flow |
1807 |
Analytical 4 Electrode Conductivity |
1808 |
Analytical 2 Electrode Conductivity |
1809 |
Analytical Troidal Conductivity |
1810 |
Analytical pH/ORP/pIon/Ion Conc |
1811 |
Analytical Oxygen |
1812 |
Pressure P, dP + Multivariable |
1813 |
Temperature 2-wire |
1814 |
Pressure w/ PID |
1815 |
Pressure Saturated Steam |
1816 |
Analytical Density - Gamma Ray |
1817 |
Level Gamma Ray |
1818 |
Analytical Weight - Gamma Ray |
1819 |
Level w/ Density - Gamma Ray |
1820 |
Analytical Motorized Density |
1821 |
Flow Multivariable Mass |
1822 |
Temperature Multivariable |
1823 |
Specialty HART-to-Analog Signal Conv |
1824 |
Flow dP |
1825 |
Pressure Low Power |
1826 |
Pressure Certified SIL2 |
1827 |
Interoperable |
1828 |
Analytical Density |
1829 |
Valve Positioner/Electropneumatic |
1830 |
Flow Magnetic Inductive |
1831 |
Analytical |
1832 |
Analytical Opacity Monitor |
1833 |
Analytical Oxygen/Combustion |
1834 |
Analytical 2-wire Conductivity |
1835 |
Analytical 2-wire Conductivity w/ pure H20 |
1836 |
Analytical 2-wire Conductivity w/ % conc |
1837 |
Analytical 2-wire Oxygen/Chlorine/Ozone |
1838 |
Analytical 2-wire pH/ORP |
1839 |
Analytical 2-wire Contacting/Toroidal |
1840 |
Analytical Oxygen - High Temperature |
1841 |
Analytical Conductivity w/ % conc |
1842 |
Analytical pH/ORP/ISE |
1843 |
Analytical Amperometric Analyzer |
1844 |
Analytical Dual Input Analyzer |
1845 |
Pressure Pressure/Level |
1846 |
Analytical Consistency |
1847 |
Analytical Microwave-Pulp Consistency |
1848 |
Analytical Microwave Consistency |
1849 |
Valve Digital Positioner |
1850 |
Valve Smart Valve Positioner |
1851 |
Temperature Differential |
1852 |
Analytical Dissolved Oxygen |
1853 |
Analytical pH Controller |
1854 |
Analytical Conductivity/Resistivity Controller |
1855 |
Analytical Conductivity/Resistivity |
1856 |
Level Displacement |
1857 |
Temperature w/ PID |
1858 |
Valve Universal Positioner |
1859 |
Level Radar - Reflex |
1860 |
Pressure Gauge |
1861 |
Pressure Sealed Gauge |
1862 |
Valve Digital Positioner w/ PID |
1863 |
Valve Intelligent Positioner |
1864 |
Analytical Gas Detector |
1865 |
Analytical Infrared Gas Detector |
1866 |
Analytical Electrochemical Gas Detector |
1867 |
Analytical Measuring Instruments |
1868 |
Level Magnostrictive |
1869 |
Valve On/Off Valve Controller |
1870 |
Level Radar - Pulse |
1871 |
Level Continuous Capactive |
1872 |
Valve Damper Actuator |
1873 |
Valve Electric Damper Actuator |
1874 |
Flow Electronic |
1875 |
Flow Vortex - Multiparameter Mass |
1876 |
Analytical UV Flame Detector |
1877 |
Analytical UVIR Flame Detector |
1878 |
Analytical IR Flame Detector |
1879 |
Analytical Fire Detector |
1880 |
Analytical Gas Detector Display Interface |
1881 |
Analytical Toxic Gas Detector |
1882 |
Analytical Flame Detector |
1883 |
Level Nuclear |
1884 |
Analytical Microwave |
1885 |
Analytical Density - Radiometric |
1886 |
Level Radiometric |
1887 |
Analytical Gas/Steam |
1888 |
Level Nucleonic |
1889 |
Analytical Blade Consistency |
1890 |
Analytical Rotary Consistency |
1891 |
Pressure Absolute/Differential |
1892 |
Positioner |
1893 |
Analytical Combustible Gas Detector |
1894 |
Analytical Point Infrared Gas Detector |
1895 |
Analytical Multi-Detector Monitor System |
1896 |
Valve Positioner/Electro-hydraulic |
1897 |
Valve Monitor |
1898 |
Enable on token-passing data link layer only |
1899 |
Enable on TDMA data link layer only |
1900 |
Enable on both TDMA and token-passing data link layer |
1901 |
WirelessHART Device |
1902 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
1903 |
Primary |
1904 |
Primary Analog Channel |
1905 |
Secondary |
1906 |
Secondary Analog Channel |
1907 |
Tertiary |
1908 |
Tertiary Analog Channel |
1909 |
Quaternary |
1910 |
Quaternary Analog Channel |
1911 |
Quinary |
1912 |
Quinary Analog Channel |
1913 |
Lock all |
1914 |
Trim not supported |
1915 |
Configuration cannot be changed |
1916 |
Locked by gateway |
1917 |
Analog Output Channel |
1918 |
The device is in simulation mode and the level output is not representative of the process. |
1919 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
1920 |
The RAM memory check is invalid or maybe corrupt |
1921 |
A watchdog reset has been performed |
1922 |
Voltage conditions out of range |
1923 |
A voltage condition is outside its allowable range |
1924 |
An internal or environmental condition is beyond acceptable limits. |
1925 |
A hardware problem not related to the sensor has been detected. |
1926 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
1927 |
Continuous |
1928 |
The Burst Message is published continuously at (worst case) the Minimum Update Period. |
1929 |
Window |
1930 |
The Burst Message is triggered when the source value deviates more than the specified trigger value |
1931 |
Rising |
1932 |
The Burst Message is triggered when source value Rises Above the specified trigger value. |
1933 |
Falling |
1934 |
The Burst Message is triggered when the source value Falls Below the specified trigger value. |
1935 |
On-change |
1936 |
The Burst Message is triggered when any value in the message changes. |
1937 |
Battery life |
1938 |
Percent range |
1939 |
Loop current |
1940 |
Primary variable |
1941 |
Secondary variable |
1942 |
Tertiary variable |
1943 |
Quaternary variable |
1944 |
Off |
1945 |
Enable event notification on token-passing data link layer |
1946 |
Enable event notification on TDMA data link layer |
1947 |
Enable event notification on TDMA and token-passing data link layer |
1948 |
Configuration changed event pending |
1949 |
Device status event pending |
1950 |
More status available event pending |
1951 |
Disable |
1952 |
Enable single data point trending |
1953 |
Enable filtered trending |
1954 |
The sample is filtered using a time constant equal to one-third the trend sample period |
1955 |
Enable average trending |
1956 |
The value obtained by dividing the sum of all samples in the period by the total number of samples |
1957 |
Read receive time |
1958 |
Write date and time |
1959 |
Non-Volatile Clock |
1960 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
1961 |
Clock Uninitialized |
1962 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
1963 |
Line Power |
1964 |
Device is powered via a hardwired connection to a plant power source. |
1965 |
Battery Power |
1966 |
Device operates solely of its (internal) battery. |
1967 |
Recharg.B./Power Sc. |
1968 |
Rechargeable battery power or power scavenging. The device has a short-term supply of energy (must be at least one hour) that is continuously being replenished. The device's power is being replenished by harvesting and converting energy from the environment surrounding the device (e.g. solar, vibration, heat). |
1969 |
Idle |
1970 |
Active search |
1971 |
Looking for neighbors. |
1972 |
Negotiating |
1973 |
Quarantined |
1974 |
Operational |
1975 |
Suspended |
1976 |
Deep sleep |
1977 |
Ultra-low power |
1978 |
Wireless Signal Found |
1979 |
Network packets have been recognized |
1980 |
Wireless Signal Identified |
1981 |
Wireless Time Synchronized |
1982 |
WirelessHart Signal Identified |
1983 |
Network Admission Requested |
1984 |
Set on transmission of first join request |
1985 |
Join Retrying |
1986 |
Set after the first join request retry (i.e. when number of join requests > 2). Cleared when device is authenticated or when Active Search started. |
1987 |
Join Failed |
1988 |
Set on transition from Active Search mode to Deep Sleep mode. Cleared on transition from Deep Sleep to Active Search. |
1989 |
Network Security Clearance Granted |
1990 |
Network Manager Session Established |
1991 |
Network Joined |
1992 |
Network Joined. Normal superframe and links obtained. |
1993 |
Network Bandwidth Requested |
1994 |
Negotiating Network Properties. Gateway session obtained. |
1995 |
Join Complete |
1996 |
Normal operating mode. |
1997 |
None |
1998 |
No restrictions |
1999 |
SI Only |
2000 |
Restricted to SI Unit codes only |
2001 |
Open - accept all devices |
2002 |
Use Whitelist for access |
2003 |
Use Blacklist |
2004 |
Use Whitelist and Blacklist |
2005 |
Lockdown - disable join links |
2006 |
Process automation device |
2007 |
Discrete device |
2008 |
Hybrid:Process automation+discrete |
2009 |
I/O System |
2010 |
WirelessHART Process automation device |
2011 |
WirelessHART Discrete device |
2012 |
WirelessHART Process automation+discrete |
2013 |
WirelessHART Gateway |
2014 |
WirelessHART Access point |
2015 |
WirelessHART Process adapter |
2016 |
WirelessHART Discrete adapter |
2017 |
WirelessHART enabled handheld/portable maintenance tool |
2018 |
Don't attempt to join |
2019 |
Join now |
2020 |
Attempt to join immediately on powerup or reset |
2021 |
US |
2022 |
United States of America |
2023 |
JP |
2024 |
Japan |
2025 |
DE |
2026 |
Germany |
2027 |
FR |
2028 |
France |
2029 |
ES |
2030 |
Spain |
2031 |
RU |
2032 |
Russian Federation |
2033 |
CN |
2034 |
People's Republic of China |
2035 |
Nominal |
2036 |
Device Power Status is nominal |
2037 |
Low |
2038 |
Device Power Status is low |
2039 |
Critically Low |
2040 |
Device Power Status is critically low |
2041 |
Recharging - Low |
2042 |
Recharging - High |
2043 |
Secondary Master |
2044 |
Primary Master |
2045 |
Device Profile |
2046 |
Device Diagnostic Status 0 |
2047 |
Device Diagnostic Status 1 |
2048 |
I/O and Subdevice Status |
2049 |
WirelessHART Status |
2050 |
Time Set Option |
2051 |
Real Time Clock Flags |
2052 |
Country |
2053 |
Country of intended device installation |
2054 |
SI Unit Control |
2055 |
Indicates if device should only display SI unit codes |
2056 |
Burst Trigger Units |
2057 |
Burst Trigger Class |
2058 |
Wired HART Enabled |
2059 |
Enabled on Wired HART device connection only |
2060 |
Wireless HART Enabled |
2061 |
Enabled on WirelessHART device connection only |
2062 |
Both Wired and WirelessHart Enabled |
2063 |
Enabled on both Wired and WirelessHART connections |
2064 |
Burst Msg Trigger Mode |
2065 |
Event Status |
2066 |
Event Notification Control |
2067 |
Operate mode Mask |
2068 |
Not Defined |
2069 |
Power Source |
2070 |
Power source of the device |
2071 |
Wireless Mode |
2072 |
Join Status |
2073 |
The current location in the joining sequence of operations. |
2074 |
Network Access Mode |
2075 |
Join Mode |
2076 |
Power Status |
2077 |
Power status of the device |
2078 |
Master Mode |
2079 |
This sets the I/O System's Data Link Layer operation on all channels as either primary or secondary master mode. |
2080 |
Trend Units |
2081 |
Trend Device Variable Unit Code |
2082 |
Trend Classification |
2083 |
Trend Device Variable Classification |
2084 |
Trend Control |
2085 |
Device Status Mask |
2086 |
Ext dev status Mask |
2087 |
Device Diagnostic Status 0 Mask |
2088 |
Device Diagnostic Status 1 Mask |
2089 |
Device Diagnostic Status 2 Mask |
2090 |
Device Diagnostic Status 3 Mask |
2091 |
AO saturated Mask |
2092 |
AO fixed Mask |
2093 |
Latched Device Status |
2094 |
Latched Ext dev status |
2095 |
Latched Operate Mode |
2096 |
Latched Device Diagnostic Status 0 |
2097 |
Latched Device Diagnostic Status 1 |
2098 |
Latched Device Diagnostic Status 2 |
2099 |
Latched Device Diagnostic Status 3 |
2100 |
Latched AO saturated |
2101 |
Latched AO fixed |
2102 |
Wireless Module Device Type |
2103 |
Device type of the Wireless Radio |
2104 |
Wireless Module Manufacturer ID |
2105 |
Manufacturer of the Wireless Radio contained in this device |
2106 |
Subdevice Device Type |
2107 |
Device type of the subdevice attached to this system. |
2108 |
Subdevice Manufacturer Id |
2109 |
Manufacturer of the subdevice attached to this system. |
2110 |
Time Stamp |
2111 |
Relative time value on network |
2112 |
8u |
2113 |
Dynamic Variables Returned for Device Variables |
2114 |
Command Response Truncated |
2115 |
Configuration Change Counter Mismatch |
2116 |
Status bytes mismatch |
2117 |
Device Variable |
2118 |
Analog Channel Number |
2119 |
Analog Channel Number- Index into an array of Analog Channels. |
2120 |
Index 1 into Analog Channel Array |
2121 |
Index into Analog Channel Array- Is the first of an array of addresses, whose value is identified by the Analog Channel Code. |
2122 |
Index 2 into Analog Channel Array |
2123 |
Index into Analog Channel Array- Is the second of an array of addresses, whose value is identified by the Analog Channel Code. |
2124 |
Index 3 into Analog Channel Array |
2125 |
Index into Analog Channel Array- Is the third of an array of addresses, whose value is identified by the Analog Channel Code. |
2126 |
Index 4 into Analog Channel Array |
2127 |
Index into Analog Channel Array- Is the fourth of an array of addresses, whose value is identified by the Analog Channel Code. |
2128 |
Are you sure? |
2129 |
No;Yes |
2130 |
Cold start is being executed,
Wait... |
2131 |
Confirmation Key |
2132 |
Access denied.
Invalid access level. |
2133 |
|
2134 |
|
2135 |
Safety Mode |
2136 |
Please reload data from device. |
2137 |
; |
2138 |
Write Lock Selection |
2139 |
Identnumber:
%{0}
Software Version:
%{2}
Production Date:
%{3} |
2140 |
Stop All Simulations |
2141 |
Stop Simulation |
2142 |
Set Value |
2143 |
Set value in %{0} |
2144 |
Start Simulation |
2145 |
Set value |
2146 |
Simulated Pulses: %[i,D]{ui32gdc_10021_28_PODSimulationValue_Value} |
2147 |
Simulated Pulses: %[i,D]{ui32gdc_5669_28_POASimulationValue_Value} |
2148 |
Simulated Pulses: %[i,D]{ui32gdc_5925_28_POBSimulationValue_Value} |
2149 |
Errors have been reset. |
2150 |
Access level %{0} granted. |
2151 |
Enter password |
2152 |
Enable Expert Mode? |
2153 |
Disable Expert Mode? |
2154 |
Warm start is being executed,
Wait... |
2155 |
%[L]{gdc_32542_28_Get_work_dataset_crc}:
%{gdc_32542_28_Get_work_dataset_crc} |
2156 |
This function will trim the device variable 'Mass Flow' (the base variable of the sensor).
Do you wish to continue? |
2157 |
Calibration finished |
2158 |
Select calibration mode |
2159 |
Break;Manual;Factory Calib.;Automatic |
2160 |
Enter Value in percent: |
2161 |
Factory Calibration OK |
2162 |
Calibration takes %[.0f]{0}s.
Please wait ... |
2163 |
Calibrate Zero %{0}. |
2164 |
Calibrate Zero %{0}%. |
2165 |
Density Calibration? |
2166 |
Enter Product Density Value in %{0} : |
2167 |
Density Calibration %{0}. |
2168 |
Mappings have been reset. |
2169 |
Set status simulation to |
2170 |
Failed to enable status simulation. |
2171 |
Status simulation disabled. |
2172 |
Status simulation enabled. |
2173 |
Failed to disable status simulation. |
2174 |
All totaliser resetted |
2175 |
Totalizer locked. |
2176 |
Select measurement |
2177 |
Totalizer started. |
2178 |
Totalizer stopped. |
2179 |
Enter preset value in %{0} |
2180 |
Totaliser set to %[f]{flTotalizerValueX} |
2181 |
Totaliser reset |
2182 |
Please wait ... |
2183 |
Select analog output |