0 |
<Image> Failure status |
1 |
As long as the image is shown grayed out, the corresponding status bit is not active. |
2 |
<Image> Maintenance required status |
3 |
<Image> Out Of specification status |
4 |
<Image> Function check status |
5 |
Volume Flow |
6 |
Mass Flow |
7 |
Level |
8 |
Volume Totalizer |
9 |
Mass Totalizer |
10 |
Field device temperature |
11 |
Volume Flow unit |
12 |
Volume Flow |
13 |
Format |
14 |
Damping value |
15 |
Process flow sensor serial sumber |
16 |
Upper sensor limit |
17 |
Lower sensor limit |
18 |
Process flow minimum span |
19 |
Class |
20 |
Family |
21 |
Update time |
22 |
Data quality |
23 |
Limit status |
24 |
Family status |
25 |
User defined unit |
26 |
User defined unit conversion factor |
27 |
Volume Flow |
28 |
User defined unit |
29 |
Mass Flow unit |
30 |
Mass Flow |
31 |
User defined unit factor |
32 |
Level measurement unit |
33 |
Level |
34 |
Primary measurement unit; physical unit for the measurand of the active process (e.g. volume flow) as well as for the corresponding limit switch - INFORMATION: changing of this parameter has no effect on the linearization area. |
35 |
m3/s |
36 |
ft3/min |
37 |
gal/min |
38 |
L/min |
39 |
ImpGal/min |
40 |
m3/min |
41 |
gal/s |
42 |
L/s |
43 |
ft3/s |
44 |
ft3/d |
45 |
m3/d |
46 |
ImpGal/h |
47 |
ImpGal/d |
48 |
m3/h |
49 |
ft3/h |
50 |
bbl/s |
51 |
bbl/min |
52 |
bbl/h |
53 |
bbl/d |
54 |
gal/h |
55 |
ImpGal/s |
56 |
L/h |
57 |
gal/d |
58 |
User defined unit |
59 |
User defined unit code defined via configurable factor. Adjustable in the 'Basic Setup' menu. |
60 |
Nm3/s |
61 |
Nm3/h |
62 |
NL/h |
63 |
Sft3/min |
64 |
NL/min |
65 |
NL/s |
66 |
SL/h |
67 |
SL/min |
68 |
SL/s |
69 |
Nm3/d |
70 |
Nm3/min |
71 |
Sft3/d |
72 |
Sft3/h |
73 |
Sft3/s |
74 |
Sm3/d |
75 |
Sm3/h |
76 |
Sm3/min |
77 |
Sm3/s |
78 |
kg/s |
79 |
g/s |
80 |
g/min |
81 |
g/h |
82 |
kg/min |
83 |
kg/h |
84 |
kg/d |
85 |
t/min |
86 |
t/h |
87 |
t/d |
88 |
lb/s |
89 |
lb/min |
90 |
lb/h |
91 |
lb/d |
92 |
STon/min |
93 |
STon/h |
94 |
STon/d |
95 |
LTon/h |
96 |
LTon/d |
97 |
m |
98 |
cm |
99 |
mm |
100 |
in |
101 |
ft |
102 |
PV value; measured value for primary measurand (PV). |
103 |
.0f |
104 |
.1f |
105 |
.2f |
106 |
.3f |
107 |
.4f |
108 |
.5f |
109 |
6e |
110 |
g |
111 |
Defines format specifier for measurements and configuration. Parameters having measurements units: "Full Scale", ranges and sensor limits.
Affects only HART applications (FC375/FC475 screens, AMS faceplates/views, PDM, FDM...) but not instrument's local display. |
112 |
Default (2 digits) |
113 |
0 digits after point |
114 |
1 digit after point |
115 |
3 digits after point |
116 |
4 digits after point |
117 |
5 digits after point |
118 |
Exponential |
119 |
Auto |
120 |
PV damping value; adjustable range 0 - 20 sec. |
121 |
Upper sensor limit; always 1.5 times upper range value. |
122 |
Lower sensor limit; always zero, not changeable. |
123 |
Device variable class. |
124 |
Device variable family. |
125 |
Update time period 'UTP'. |
126 |
Process data quality 'PDQ'. |
127 |
Limit status 'LS'. |
128 |
Family status 'FS'. |
129 |
More device family status available |
130 |
Name of the user defined unit for Volume Flow. |
131 |
Conversion factor for User Defined Volume Flow Unit for Volume Flow. |
132 |
Name of the user defined unit for Mass Flow. |
133 |
Conversion factor for User Defined Volume Flow Unit for Mass Flow. |
134 |
Name of the user defined unit for Level measurement. |
135 |
The value of the user defined unit factor for Level. |
136 |
Volume Totalizer unit |
137 |
Totalizer format |
138 |
Totalizer damping |
139 |
Totalizer sensor serial number |
140 |
Upper total limit |
141 |
Lower total limit |
142 |
Totalizer minimum span |
143 |
Mass Totalizer unit |
144 |
Mass Totalizer |
145 |
Name of the user defined unit for Volume Totalizer. |
146 |
The value of the user defined unit factor for Volume Totalizer. |
147 |
Name of the user defined unit for Mass Totalizer. |
148 |
The value of the user defined unit factor for Mass Totalizer. |
149 |
Counter unit; unit for the totalized flow rate (e.g. volume). |
150 |
m3 |
151 |
ImpGal |
152 |
L |
153 |
gallon |
154 |
bbl |
155 |
ft3 |
156 |
bbl (liq) |
157 |
hl |
158 |
Nm3 |
159 |
NL |
160 |
Sft3 |
161 |
SL |
162 |
Sm3 |
163 |
kg |
164 |
t |
165 |
lb |
166 |
STon |
167 |
LTon |
168 |
SV value; value of the totalizer (SV). |
169 |
Defines format specifier for totalizers' values, that is meaningful only for HART applications (FC375/FC475 screens, AMS faceplates, PDM, FDM...).
Has no influence on the instrument display. |
170 |
Default (1 digit) |
171 |
2 digits after point |
172 |
Reaction of the measured value according to process changes; after this time the output value increases to 63% of change in process. |
173 |
Upper sensor limit for Totalizer; fixed point (999e12 cum). |
174 |
Lower sensor limit for Totalizer; always zero, not changeable. |
175 |
Field device temperature unit |
176 |
Field device temperature unit; measured temperature of the field device's electronic components. |
177 |
Field device temperature |
178 |
TV value; measured value of the electronic temperature (TV). |
179 |
Temperature format |
180 |
Defines format specifier for values for electronic temperature, that is meaningful only for HART applications (FC375/FC475 screens, AMS faceplates, PDM, FDM...).
Has no influence on the instrument display. |
181 |
Temperature damping value |
182 |
Temperature sensor serial number |
183 |
Upper temperature sensor limit |
184 |
Upper temperature sensor limit for field device electronic temperature; defined to 125°C. |
185 |
Lower temperature sensor limit |
186 |
Lower sensor limit for field device electronic temperature; defined to -45°C. |
187 |
dummyuun |
188 |
dummy |
189 |
dummyuunh |
190 |
clsETemperature |
191 |
|
192 |
Manufacturer ID |
193 |
Manufacturer ID; References a specific manufacturer, which is usually a company name that is responsible for the manufacture of this field device. |
194 |
Manufacturer device type code |
195 |
Manufacturer device type code; References the type of field device, usually an advertised model number that is unique to a single manufacturer. |
196 |
ESK4A |
197 |
Write protect code |
198 |
Loop current mode |
199 |
Loop current mode; indicates whether the loop current is active or fixed (i.e., the device is in multi-drop). |
200 |
Disabled |
201 |
Enabled |
202 |
Device status |
203 |
Field device status: Data indicating that the field device has detected condition(s) in the field device relating to: its hardware, the validity of a variable, its operating status or an internal process. |
204 |
Maintenance required |
205 |
Maintenance required, function will soon be restricted.
(NE 107 status signal). |
206 |
Failure |
207 |
Operational fault in device. No measurement possible.
(NE 107 status signal). |
208 |
Out of specification |
209 |
Out of specification, measurement continues with less accuracy.
(NE 107 status signal). |
210 |
Function check |
211 |
Testing mode by invoking test or simulation functions.
(NE 107 status signal). |
212 |
Status simulation active |
213 |
Status simulation active; indicates whether the status simulation is currently running. The status simulation can be enabled/disabled under 'Diagnosis/Tests'->'Status simulation and mapping'->'Device status'. |
214 |
Number request preambles |
215 |
Number of request preambles; number of preambles required from the host request by the field device (min. 5). |
216 |
Tag |
217 |
Tag; free text stored in the field device, it is recommended to use it as a unique label for the field device in the plant (max. 8 characters). |
218 |
Long tag |
219 |
Long tag; functions exactly like Tag except the size is larger (max of 32 ISO Latin 1 characters). |
220 |
Device ID |
221 |
Device ID; device identification of the HART transmitter. |
222 |
Number response preambles |
223 |
Number of response preambles; number of preambles the field device has to send in response to a request from host (5 to 20 are possible). |
224 |
Universal command revision |
225 |
Universal revision; revision of the universal device description that the field device conforms to. |
226 |
Device revision |
227 |
Device revision; revision of the specific device description that the field device conforms to. |
228 |
Descriptor; free text stored in the field device, is typically used for the precise description of the metering point. |
229 |
Date; gregorian calendar date stored in the field device, typically the mounting date of the metering point. |
230 |
Message; free text stored in field device; there is no specific recommended use. |
231 |
Final assembly number |
232 |
Final assembly number; free number stored in field device; there is no specific recommended use. |
233 |
Polling address |
234 |
Polling address; address used by the host to identify a field device in multi drop mode; any address from 1 to 15 sets the analog output to a fixed value of about 4 mA. |
235 |
Status group error |
236 |
Temperature sensor failure |
237 |
Hardware failure in the field device; 4-20 mA converter must be replaced. |
238 |
Sensor B failure |
239 |
Sensor A failure |
240 |
Invalid drift between digital and reference voltage |
241 |
Crystal failure |
242 |
Memory corruption detected |
243 |
Data in the memory of the field device are inconsistent; restart is recommended; if error still exists then the 4-20mA converter must be replaced. |
244 |
NVRAM (FRAM) error |
245 |
ROM error |
246 |
Status group warning 1 |
247 |
PV between 1.1 x FS and 1.5 x FS |
248 |
Primary variable between 1.1 x FS and 1.5 x FS (FS: full scale value) |
249 |
Electronic temperature out of limits (-45°...+125°) |
250 |
Temperature in the field device out of limits; replacing the 4-20mA converter is recommended |
251 |
No output linearization |
252 |
Linearization of the primary variable is not active; to meet the measurement accuracy, linearization at the manufacturer is recommended for the field device |
253 |
No temperature compensation |
254 |
Temperature compensation in the field device is not active; to meet the measurement accuracy over the temperature range, replacing the 4-20mA converter is recommended |
255 |
No pre linearization |
256 |
Linearization of the sensors from field device is not active; to meet the measurement accuracy, linearization at the manufacturer is recommended for the field device |
257 |
PV out of upper limit (1.5 x full scale value) |
258 |
Value of the primary variable exceeds the upper limit and no longer follows the current process; review process and adjust if necessary |
259 |
Electronic temperature out of range (-40°...+85°) |
260 |
Temperature in the field device is out of range, which may lead to a permanent defect; review process temperature and adjust if necessary |
261 |
Internal communication failed |
262 |
Internal communication failed |
263 |
Status group warning 2 |
264 |
y value for last table index is not 100% |
265 |
Failure during linearization process; to meet the measurement accuracy, linearization at the manufacturer is recommended for the field device |
266 |
x value for first table index is not 0% |
267 |
x y values not monotonous increasing |
268 |
Too few number of x y values |
269 |
Conflict between unit system and unit code |
270 |
Linearization table under configuration |
271 |
New linearization table bad, use old table |
272 |
Failure in new linearization table; field device works with prior linearization table |
273 |
No linearization table valid |
274 |
No valid linearization table; to meet the measurement accuracy, linearization at the manufacturer is recommended for the field device |
275 |
Status group warning 3 |
276 |
Reserved |
277 |
- |
278 |
Local transmitter configuration activated |
279 |
Local control of the field device is active; writing of parameters is currently not possible |
280 |
Loop test by local push-button activated |
281 |
Local loop current test is active; 4-20mA loop current applies not to current process |
282 |
Restart of device |
283 |
Field device has performed a restart; download of all parameters is recommended |
284 |
Totalizer value lost or overflow |
285 |
Wrong secondary variable (Totalizer); reset of totalized value is recommended |
286 |
No FS calibration of current output |
287 |
No gain adjustment; to meet the measurement accuracy, gain adjustment of the analog output is recommended |
288 |
No zero calibration of current output |
289 |
No zero adjustment; to meet the measurement accuracy, zero adjustment of the analog output is recommended |
290 |
Status group information 1 |
291 |
B2: SV >= SV switch point limit |
292 |
The current value of the secondary variable (Totalize) exceeds switching point limit (B2) |
293 |
B2: PV < (PV switch point limit - PV switch point hysteresis) |
294 |
The current value of the primary variable has fallen below switching point limit - including hysteresis (B2) |
295 |
B2: PV >= PV switch point limit |
296 |
The current value of the primary variable exceeds switching point limit (B2) |
297 |
Binary output B2 (ESK4-IO module) is activated |
298 |
Binary output B2 is active and ready for use |
299 |
B1: SV >= SV switch point limit |
300 |
The current value of the secondary variable (Totalize) exceeds switching point limit (B1) |
301 |
B1: PV < (PV switch point limit - PV switch point hysteresis) |
302 |
The current value of the primary variable has fallen below switching point limit - including hysteresis (B1) |
303 |
B1: PV >= PV switch point limit |
304 |
The current value of the primary variable exceeds switching point limit (B1) |
305 |
Binary output B1 (ESK4-IO module) is activated |
306 |
Binary output B1 is active and ready for use |
307 |
Status group information 2 |
308 |
Extended module ESK4-Fieldbus detected |
309 |
Extended Fieldbus module detected |
310 |
Extended module ESK4-IO detected |
311 |
Extended IO module detected |
312 |
Device is in multi drop mode |
313 |
Field device is in multi drop mode; 4-20mA loop current does not apply to current process |
314 |
Binary input B3 (ESK4-IO module) is activated |
315 |
Binary input B3 is active and ready for use |
316 |
Electronics |
317 |
F Electronics |
318 |
Configuration |
319 |
C Configuration |
320 |
Sensor |
321 |
S Sensor |
322 |
S Electronics |
323 |
S Configuration |
324 |
Gas bubbles in the liquid |
325 |
Gas bubbles in the liquid |
326 |
Pulsating flow |
327 |
Pulsating flow |
328 |
External magnetic fields |
329 |
External magnetic fields |
330 |
Internal communication error |
331 |
Sensor failure |
332 |
Blocked float |
333 |
Blocked float |
334 |
Binary I/O activation |
335 |
HART mode |
336 |
Extension modules |
337 |
Totalizer |
338 |
Binary output B2 |
339 |
Binary output B1 |
340 |
Perform warmstart |
341 |
Perform warmstart; restart the firmware of the field device. |
342 |
Loop test |
343 |
Test current loop; analog output is fixed to transferred current value WARNING! and is not tracking the active prozess (flow). |
344 |
Transmitter selftest |
345 |
Selftest; performs a selftest in the field device; the result is visible in field device status. |
346 |
Device under local control |
347 |
Loop current |
348 |
PV loop current; declaration of value in mA (range 4 - 20 mA). |
349 |
Alarm selection code |
350 |
Alarm selection code; In the event of an error the analogue output can signalize a failure high signal >21mA or failure low signal <3.6mA. Some device versions are limited to fail high option only. |
351 |
High |
352 |
Low |
353 |
Percent of range |
354 |
Percent of range; declaration of value in percent of the measured value. |
355 |
Transfer Function |
356 |
Transfer function; ESK4A output is linear. |
357 |
URV |
358 |
Upper range value; final value for which the field device is calibrated. |
359 |
LRV |
360 |
Lower range value; always zero, not changeable. |
361 |
Binary input |
362 |
Binary input; by H-or L-level at the binary input B3 (terminal 7/8), the totalizer can be controlled (function reset or start/stop). |
363 |
Inactive |
364 |
Reset (active high) |
365 |
Reset (active low) |
366 |
Start (active high) / Stop (active low) |
367 |
Start (active low) / Stop (active high) |
368 |
Device in level measurement mode |
369 |
LFC control |
370 |
Lfc control; switching the lfc on or off. |
371 |
Off |
372 |
On |
373 |
LFC on value |
374 |
Lfc on value; if PV (primary measurand) falls below this value, the measurement scale is set to zero (adjustable between 1% and 19%). |
375 |
LFC off value |
376 |
Lfc off value; if PV (primary measurand) exceeds this value, the measurement scale follows the actual flow rate (adjustable between 2% and 20%). |
377 |
Counter option |
378 |
Totalizer stopped |
379 |
Totalizer resumed |
380 |
Pulse width |
381 |
Pulse width; following pulse widths can be adjusted, 50ms (max pulse = 36000 /s), 100ms (max pulse = 18000 /s), 200ms (max pulse = 9000 /s), 500ms (max pulse = 3600 /s). |
382 |
50 ms |
383 |
100 ms |
384 |
200 ms |
385 |
500 ms |
386 |
Pulse / Unit |
387 |
Pulse value; pulse pro volume (mass) value. The maximum frequency of the pulse output mustn't exceed even at maximum flow (final value). Valid range of values: 0.001 to 999.0 |
388 |
Unit conflict |
389 |
Number of calibration points |
390 |
Number of calibration points; number of saved calibration points. |
391 |
Type of primary measured value |
392 |
Calibrated unit system; shows the primary measurand. |
393 |
Full scale linearization value |
394 |
Full scale calibration value; full scale of the primary measurand at the time of linearization. |
395 |
Linearization unit |
396 |
Calibration unit; unit of the primary measurand. |
397 |
Phase of fluid |
398 |
Phase of operating fluid (0 =liquid; 1 = gaseous). |
399 |
Liquid |
400 |
Gaseous |
401 |
Phase of ref. fluid |
402 |
Phase of reference fluid (0=liquid; 1=gaseous). |
403 |
Pressure reference |
404 |
Pressure reference; reference for the pressure designation (under-, over-, normalpressure). |
405 |
Absolute |
406 |
Gauge over absolute pressure |
407 |
Low |
408 |
Density reference |
409 |
Density reference; reference for the density designation (operating-, normalpressure). |
410 |
Normal |
411 |
Operating |
412 |
Volume Flow reference |
413 |
Volume flow reference; shows the reference for the primary measurand (operating- resp. standard conditions). |
414 |
Volume reference |
415 |
Normal: Volume flow under normal conditions according to DIN 1343; Standard: Volume flow under standard conditions according to ISO 13443:1996. |
416 |
Standard |
417 |
Firmware version |
418 |
Firmware version; version that corresponds to the firmware of the field device. |
419 |
Production order |
420 |
Production order; production order for the complete field device. |
421 |
Temperature |
422 |
Fluid temperature; temperature of the process the field device is calibrated for. |
423 |
Pressure |
424 |
Fluid pressure; pressure of the process the field device is calibrated for. |
425 |
Density |
426 |
Fluid density; fluid density of the process the field device is calibrated for. |
427 |
Viscosity |
428 |
Viscosity; viscosity of the process the field device is calibrated for. |
429 |
Compressibility |
430 |
Compressibility factor; specifies the deviation between the real gas and ideal gas. |
431 |
Actual function (B1) |
432 |
Switchpoint actual function; specifies the allocation for the binary output B1 (inactive / limitswitch primary measurement / limitswitch totalizer / pulse output*) (* The pulse output is only available in case of an IO module). |
433 |
Limit for Process Value |
434 |
Limit for Totalizer |
435 |
Pulse output |
436 |
Limit for Level |
437 |
PV switch-point (B1) |
438 |
PV switch point limit; range 0.0 ... upper range value, if current primary measurement exceeds the appointed switchpoint, the output changes the binary status. |
439 |
PV switch-point hysteresis (B1) |
440 |
PV switch point hysteresis; range 0.0 ... switchpoint, if current primary measurement exceeds the appointed switchpoint, the output changes the binary status. To return to initial position, the switchpoint value reduced by the hysteresis must be under-run. |
441 |
Totalizer switch-point (B1) |
442 |
SV switchpoint limit; range 0.0 ... totalizer limit, if the current totalizer value exceeds adjusted limit switch value, the output changes the binary status. There is no hysteresis adjustment for this switchpoint. |
443 |
Type of contact (B1) |
444 |
Switchpoint type of contact; the binary limit switch output can be assigned to normally closed contact or normally open contact. |
445 |
Normally open |
446 |
Normally closed |
447 |
Actual function (B2) |
448 |
Switchpoint actual function; specifies the allocation for the binary output B2 (inactive / limitswitch primary measurement / limitswitch totalizer / pulse output*) (* The pulse output is only available in case of an IO module). |
449 |
PV switch-point (B2) |
450 |
PV switch-point hysteresis (B2) |
451 |
Totalizer switch-point (B2) |
452 |
Type of contact (B2) |
453 |
Hysteresis value higher than limit. |
454 |
Warning: Item is currently not applicable |
455 |
Name of fluid |
456 |
Fluid name; fluid for which the field device is calibrated. |
457 |
Meter type |
458 |
Meter type; manufacturer code for used meter type. |
459 |
H250 |
460 |
H250 C |
461 |
BW25 |
462 |
H250 H |
463 |
H250 U |
464 |
Special |
465 |
Indicator type |
466 |
Indicator type; shows the used indicator type. |
467 |
M9 |
468 |
M40 |
469 |
Nominal meter size |
470 |
Nominal meter size; nominal meter size of used measuring tube. |
471 |
15 mm |
472 |
25 mm |
473 |
50 mm |
474 |
80 mm |
475 |
100 mm |
476 |
Not used |
477 |
Type of cone |
478 |
Type of cone, shows the used type of cone. |
479 |
K 15.1 |
480 |
K 15.2 |
481 |
K 15.3 |
482 |
K 15.4 |
483 |
K 15.5 |
484 |
K 15.6 |
485 |
K 15.7 |
486 |
K 15.8 |
487 |
K 25.1 |
488 |
K 25.2 |
489 |
K 25.3 |
490 |
K 25.4 |
491 |
K 25.5 |
492 |
K 55.1 |
493 |
K 55.2 |
494 |
K 55.3 |
495 |
K 85.1 |
496 |
K 85.2 |
497 |
K 105.1 |
498 |
K 005 |
499 |
K 010 |
500 |
K 015 |
501 |
K 040 |
502 |
K 080 |
503 |
K 125 |
504 |
K 200 |
505 |
K 300 |
506 |
K 340 |
507 |
E 17.1 |
508 |
E 17.2 |
509 |
E 17.3 |
510 |
E 17.4 |
511 |
E 17.5 |
512 |
E 17.6 |
513 |
E 17.7 |
514 |
E 17.8 |
515 |
E 27.1 |
516 |
E 27.2 |
517 |
E 27.3 |
518 |
E 27.4 |
519 |
E 27.5 |
520 |
E 57.1 |
521 |
E 57.2 |
522 |
E 57.3 |
523 |
E 87.1 |
524 |
E 87.2 |
525 |
E 107.1 |
526 |
E 107.2 |
527 |
E 57.4 |
528 |
E 87.3 |
529 |
New Cone 1 |
530 |
New Cone 2 |
531 |
Not used |
532 |
Type of float |
533 |
Type of float; manufacturer code for used type of float. |
534 |
C IV 15 |
535 |
D IV 15 |
536 |
T IV 15 |
537 |
D IV T 15 |
538 |
C IV 25 |
539 |
D IV 25 |
540 |
T IV 25 |
541 |
C IV 55 |
542 |
D IV 55 |
543 |
T IV 55 |
544 |
D IV T 55 |
545 |
C IV 85 |
546 |
D IV 85 |
547 |
T IV 85 |
548 |
D IV T 85 |
549 |
C IV 105 |
550 |
D IV 105 |
551 |
N1 |
552 |
N2 |
553 |
T IV 105 |
554 |
D IV T 105 |
555 |
N3 |
556 |
D IV TB 15 F02 |
557 |
D IV T 25 F04 |
558 |
D IV T 55 F06 |
559 |
D IV T 85 F09 |
560 |
D IV L 105 F09 |
561 |
D IV TB 15 F03 |
562 |
D IV T 25 F05 |
563 |
D IV T 55 F08 |
564 |
D IV T 85 F11 |
565 |
D IV L 105 F11 |
566 |
D IV TR 15 |
567 |
C IV TL 25 |
568 |
D IV TL 25 |
569 |
D IV L 55 |
570 |
C IV L 85 |
571 |
D IV L 85 |
572 |
D IV L 105 |
573 |
D IV L 25 |
574 |
D IV 55/30 |
575 |
T IV B 15 F02 |
576 |
T IV B 15 F03 |
577 |
T IV 25 F04 |
578 |
T IV 25 F05 |
579 |
T IV 55 F06 |
580 |
T IV 55 F07 |
581 |
T IV 55 F08 |
582 |
D IV 55 F07 |
583 |
T IV 85 F09 |
584 |
T IV 85 F10 |
585 |
T IV 85 F11 |
586 |
D IV T 85 F10 |
587 |
D IV T 105 F09 |
588 |
D IV T 105 F10 |
589 |
D IV T 105 F11 |
590 |
D IV L 105 F10 |
591 |
T IV L 15 |
592 |
D IV TB 15 F22 |
593 |
D IV T 25 F24 |
594 |
D IV T 55 F26 |
595 |
D IV T 85 F29 |
596 |
D IV L 105 F29 |
597 |
D IV L 105 F31 |
598 |
Not Used |
599 |
Material of float |
600 |
Material of float; shows the used material of float. |
601 |
Stainless steel |
602 |
Aluminium |
603 |
Hastelloy B2 |
604 |
Hastelloy C4 |
605 |
PTFE |
606 |
Ceramic |
607 |
Titanium |
608 |
POM |
609 |
Ruby |
610 |
PEEK |
611 |
Teflon-TFM |
612 |
Hard-rubber |
613 |
Glass |
614 |
Password |
615 |
Write protection |
616 |
If activated the field device does not accept any changes; e.g. causes that actions on some commands can not occur. |
617 |
Level Unit |
618 |
Length of displacement rod |
619 |
Displacement rod length; length of the used displacement rod. |
620 |
Type of process connection |
621 |
Level process connection type; connection to the process (e.g. specification of nominal size and pressure stage). |
622 |
Serial number of meter |
623 |
Serial number of meter; serial number of the complete field device |
624 |
Electronic revision |
625 |
Electronic revision; revision that corresponds to the electronics hardware of the field device. |
626 |
IO module status |
627 |
IO module status; status of optional IO module (not available / active). |
628 |
Not available |
629 |
Active (good) |
630 |
IO module firmware version |
631 |
IO module firmware version; firmware version of the field device's IO module, eg.: "V01.1.13" |
632 |
Display rotation |
633 |
Control value for rotation of the display view direction (ESK4A-IO ) |
634 |
0° |
635 |
90° |
636 |
180° |
637 |
270° |
638 |
Serial number of IO module |
639 |
Serial number of IO module; serial number of optional IO module. |
640 |
Article Codes |
641 |
Display mode |
642 |
Selected display mode (optional module ESK4-IO ) |
643 |
PV measured value |
644 |
SV (Totalize measured value) |
645 |
Cyclic PV & Totalizer |
646 |
Static PV & Totalizer |
647 |
PV in percent of range |
648 |
Selected language |
649 |
Selected language (local Display optional module ESK4-IO ) |
650 |
English |
651 |
German |
652 |
French |
653 |
Italian |
654 |
Spanish |
655 |
Czech |
656 |
Polish |
657 |
Dutch |
658 |
Danish |
659 |
Invalid device variable index |
660 |
Device variable index not allowed for this command |
661 |
Invalid transaction number |
662 |
Unit code factor too large |
663 |
Status Bit Not Supported |
664 |
No Effect |
665 |
Maintenance Required |
666 |
Failure |
667 |
Out of Specification |
668 |
Function Check |
669 |
Reset |
670 |
Set |
671 |
Secondary Analog Channel Fixed |
672 |
Used to map a status condition to a severity level. |
673 |
Tertiary Analog Channel Fixed |
674 |
Quaternary Analog Channel Fixed |
675 |
Quinary Analog Channel Fixed |
676 |
Condensed status simulation |
677 |
Allows simulation of different status conditions. |
678 |
Condensed status value |
679 |
Device Specific Error |
680 |
Starting status map index must be even value. |
681 |
Bit Index |
682 |
Reset Condensed Status Map |
683 |
Show single events |
684 |
On occurence |
685 |
Always |
686 |
Never |
687 |
F Sensor |
688 |
F Configuration |
689 |
Process |
690 |
F Process |
691 |
C Sensor |
692 |
C Electronics |
693 |
C Process |
694 |
S Process |
695 |
M Sensor |
696 |
M Electronics |
697 |
M Configuration |
698 |
M Process |
699 |
Extension module ESK4-Fieldbus detected |
700 |
Status information, no action necessary |
701 |
Extension module ESK4-IO detected |
702 |
Device is in multi drop mode |
703 |
Binary input B3 (ESK4-IO module) is activated |
704 |
Binary output B2 (ESK4-IO module) is activated |
705 |
Binary output B1 (ESK4-IO module) is activated |
706 |
SV >= SV switch point limit |
707 |
PV < (PV switch point limit-PV switch point hysteresis) |
708 |
PV >= PV switch point limit |
709 |
New linearization table bad, use old Table |
710 |
Linearization by trained personell: a valid linearization table has to be written. |
711 |
Totalizer value lost or overflow |
712 |
Totalizer starts counting at 0 again. No action necessary. |
713 |
Check environment for external magnetic fields, remove measuring system from external magnetic field |
714 |
Check application |
715 |
Gas bubbles in the liquid |
716 |
Check application. |
717 |
Check application. Perform maintenance of meter as described by manufacturer. |
718 |
Sensor B failure |
719 |
Restart device, if error still is signaled, exchange electronic module. |
720 |
Sensor A failure |
721 |
Temperature sensor failure |
722 |
Adopt measures to adapt the environmental temperature of electronics. |
723 |
ESK4-IO firmware not compatible |
724 |
Replace ESK4-IO module with a one running compatible firmware |
725 |
Internal communication failed |
726 |
Check 6-pole cable between ESK4 Basic and ESK4-IO module, exchange ESK4-IO module |
727 |
No FS calibration of current output |
728 |
Linearization by trained personell: full scale calibration (20 mA) of current output has to be done |
729 |
No zero calibration of current output |
730 |
Linearization by trained personell: zero calibration (4 mA) of current output has to be done |
731 |
y value for last table index is not 100% |
732 |
Linearization by trained personell: check and correct y value of linearization table |
733 |
x value for first table index is not 0% |
734 |
Linearization by trained personell: check and correct x value of linearization table |
735 |
x y values not monotonous increasing |
736 |
Linearization by trained personell: check and correct x y values of linearization table |
737 |
Too few number of x y values |
738 |
Linearization by trained personell: choose more x y values for linearization |
739 |
Conflict between unit system and unit code |
740 |
Linearization by trained personell: choose propper unit code |
741 |
Linearization table under configuration |
742 |
Output linearization has to be finished by trained personell -> write linearization data to the device |
743 |
No linearization table valid |
744 |
Output linearization has to be done at manufacturer site |
745 |
No output linearization |
746 |
Output linearization has to be done at manufacturer site |
747 |
No temperature compensation |
748 |
Temperature compensation has to be done at manufacturer site |
749 |
No pre linearization |
750 |
Pre linearization has to be done at manufacturer site |
751 |
Electronic temperature
T < -40°C or T > +85°C |
752 |
Electronic temperature
T < -45°C or T > +125°C |
753 |
PV between 1.1 x FS and 1.5 x FS |
754 |
Check calibration |
755 |
PV out of upper limit (1.5 x FS) |
756 |
Local transmitter configuration activated |
757 |
Exit menu of module ESK4-IO |
758 |
Current loop test by local push-button activated |
759 |
Exit current loop test by:
a) waiting 60 seconds
b) pushing local button for more than 3 seconds |
760 |
Invalid drift between digital and reference voltage |
761 |
Crystal failure |
762 |
Memory corruption detected |
763 |
NVRAM (FRAM) error |
764 |
ROM error |
765 |
Reset to default |
766 |
Reset the mappings to the condensed status to default values. |
767 |
Set simulation bits |
768 |
Set simulation bits; This method sets the simulation bits in the device. |
769 |
Enable/disable status simulation |
770 |
Enable/disable status simulation. |
771 |
Device status display |
772 |
Device status display menu.
Provides access to the current device status. |
773 |
Condensed status (NE 107) |
774 |
Condensed status (NE 107) menu.
Displays the HART condensed device status indicators according to NAMUR NE107. |
775 |
Classic view |
776 |
Standard status display menu.
Provides access to the device status according to HART standard. |
777 |
Detail |
778 |
Failure ('F') |
779 |
Function check ('C') |
780 |
Out of specification ('S') |
781 |
Group status view |
782 |
Additional status display menu.
Provides access to additional device specific status. |
783 |
Device status simulation menu.
Provides access to simulation functions for the device status. |
784 |
Simulation values |
785 |
Simulation values for the device status. |
786 |
Simulation status |
787 |
Select the bits that should be simulated. |
788 |
Variable F/C/S/M |
789 |
Current device status |
790 |
Shows the current device status. |
791 |
Status mapping |
792 |
Status mapping menu.
Provides access to the mapping of device status into the indicators of the HART condensed status according to NAMUR NE107. |
793 |
Manufacturer image |
794 |
Process Variables |
795 |
Measured Values |
796 |
Device variables |
797 |
HART Variables |
798 |
Measured values (chart) |
799 |
Measured values (bar) |
800 |
Measured values (scope) |
801 |
Current output |
802 |
Current output (chart) |
803 |
Current output (bar) |
804 |
% range |
805 |
Loop current |
806 |
Current output (scope) |
807 |
Diagnosis/Tests |
808 |
Status simulation and mapping |
809 |
Test / Reset |
810 |
Methods to test and reset the device. |
811 |
Device tests |
812 |
Device resets |
813 |
Device root menu |
814 |
Basic setup |
815 |
Engineering units |
816 |
Detailed setup |
817 |
Device information |
818 |
Process input |
819 |
Primary measured value |
820 |
Totalizer |
821 |
Field device temperature |
822 |
Output |
823 |
Limit switch functions |
824 |
B1 |
825 |
B2 |
826 |
Sensor |
827 |
Type of device |
828 |
Linearization condition |
829 |
Identification |
830 |
Operating fluid |
831 |
IO module |
832 |
HART |
833 |
General |
834 |
Identification |
835 |
Parameter protection |
836 |
Revisions |
837 |
Preambles |
838 |
Display settings |
839 |
Display settings for the ESK4A-IO module |
840 |
Offline |
841 |
Identification device |
842 |
Setup |
843 |
Limit switches |
844 |
DD-Version |
845 |
Version number of the device description according to NAMUR specification. 01.01.01-01 |
846 |
01.01.01 |
847 |
Write variables |
848 |
Read variables |
849 |
Reset Configuration Changed flag |
850 |
Reset configuration changed flag; resets the configuration changed flag, according to HCF_SPEC-191 Rev. 8.0 |
851 |
Stop/Resume Totalizer |
852 |
Handle Totalizer; totalizer start / stop. |
853 |
Reset Totalizer |
854 |
Reset Totalizer; set counter to zero, counter will not be stopped. |
855 |
Set to default values |
856 |
Standard values; restore factory setting, current linearization table and associated parameters stay maintained. |
857 |
Change password |
858 |
If write protection is disabled changing the password is possible. Password must be a positive value (0..4294967295). |
859 |
Change write protection |
860 |
Enable / Disable write protection. If enabled the field device does not accept any changes; e.g. causes that actions on some commands can not occur. |
861 |
Simulate alarm current |
862 |
Simulate alarm current; i.e. set current to either low or high alarm current depending on the setting of the Alarm Selection Code. |
863 |
Reset extended status |
864 |
Reset extended status; resets all warnings from extended status byte Command 48 |
865 |
PV Analog Channel Saturated |
866 |
PV Analog Channel Fixed |
867 |
Analog Input Channel |
868 |
Analog Output Channel |
869 |
Device Profile |
870 |
Device Diagnostic Status 0 |
871 |
Device Diagnostic Status 1 |
872 |
I/O and Subdevice Status |
873 |
WirelessHART Status |
874 |
Wireless |
875 |
WirelessHART Device |
876 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
877 |
Secondary Analog Channel Saturated |
878 |
Tertiary Analog Channel Saturated |
879 |
Quaternary Analog Channel Saturated |
880 |
Quinary Analog Channel Saturated |
881 |
Critical Power Failure |
882 |
Process automation device |
883 |
Discrete device |
884 |
Hybrid:Process automation+discrete |
885 |
I/O System |
886 |
WirelessHART Process automation device |
887 |
WirelessHART Discrete device |
888 |
WirelessHART Process automation+discrete |
889 |
WirelessHART Gateway |
890 |
WirelessHART Access point |
891 |
WirelessHART Process adapter |
892 |
WirelessHART Discrete adapter |
893 |
WirelessHART enabled handheld/portable maintenance tool |
894 |
Simulation active |
895 |
The device is in simulation mode and the level output is not representative of the process. |
896 |
Non-Volatile memory failure |
897 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
898 |
Volatile memory error |
899 |
The RAM memory check is invalid or maybe corrupt |
900 |
Watchdog reset executed |
901 |
A watchdog reset has been performed |
902 |
Voltage conditions out of range |
903 |
A voltage condition is outside its allowable range |
904 |
Environmental conditions out of range |
905 |
An internal or environmental condition is beyond acceptable limits. |
906 |
Electronic failure |
907 |
A hardware problem not related to the sensor has been detected. |
908 |
Subdevice list changed |
909 |
Duplicate master detected |
910 |
Capacity Denied |
911 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
912 |
Bandwidth allocation pending |
913 |
Block transfer pending |
914 |
Time Stamp |
915 |
Relative time value on network |
916 |
8u |
917 |
Dynamic Variables Returned for Device Variables |
918 |
Command Response Truncated |
919 |
Configuration Change Counter Mismatch |
920 |
Status bytes mismatch |
921 |
Device Variable |
922 |
8.3f |
923 |
Are you sure? |
924 |
No;Yes |
925 |
Mappings have been reset. |
926 |
Set status simulation to |
927 |
Failed to enable status simulation. |
928 |
Status simulation disabled. |
929 |
Status simulation enabled. |
930 |
Failed to disable status simulation. |
931 |
OK |
932 |
Totalizer |
933 |
Stop;Resume |
934 |
Counters are set to zero. |
935 |
Device is reset to default parameter. |
936 |
Writeprotection still active |
937 |
Please enter password. |
938 |
var1_passw |
939 |
Please reenter password. |
940 |
var2_passw |
941 |
Password changed. |
942 |
Passwords are not equal. |
943 |
var_passw |
944 |
Write protection changed. |
945 |
Start simulation? This will set the current output into alarm current. |
946 |
The device is in multi drop mode and, as a result, the command cannot be executed |
947 |
Simulation is running. Do you want to end it? |
948 |
Extended device status succussfully reset |