0 |
DRG.M & DRS |
1 |
JSC EPF SIBNA |
2 |
Cистемная ошибка |
3 |
Отсутствует ультразвук |
4 |
Полезный сигнал слишком мал |
5 |
Полезный сигнал слишком плохой |
6 |
Может присутствовать наводка |
7 |
Нет настроек изготовителя |
8 |
Расход больше нуля, но слишком мал |
9 |
Расход слишком велик |
10 |
.3f |
11 |
8.3f |
12 |
PV Update Period |
13 |
|
14 |
7d |
15 |
Flow Lower trim |
16 |
Flow Upper trim |
17 |
Flow Trim support |
18 |
Flow Min lower trim |
19 |
Flow Max lower trim |
20 |
Flow Min upper trim |
21 |
Flow Max upper trim |
22 |
Flow Min trim diff |
23 |
Simulate |
24 |
Update Period |
25 |
Flow |
26 |
Device settings |
27 |
Diagnostics |
28 |
Operate |
29 |
Flow sensor |
30 |
Dynamic Variables |
31 |
PV |
32 |
PV Analog Channel Saturated |
33 |
PV Analog Channel Fixed |
34 |
Wireless |
35 |
WirelessHART Device |
36 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
37 |
Primary |
38 |
Primary Analog Channel |
39 |
Secondary |
40 |
Secondary Analog Channel |
41 |
Tertiary |
42 |
Tertiary Analog Channel |
43 |
Quaternary |
44 |
Quaternary Analog Channel |
45 |
Quinary |
46 |
Quinary Analog Channel |
47 |
Critical Power Failure |
48 |
Lock all |
49 |
Trim not supported |
50 |
Configuration cannot be changed |
51 |
Locked by gateway |
52 |
Analog Input Channel |
53 |
Analog Output Channel |
54 |
Secondary Analog Channel Saturated |
55 |
Tertiary Analog Channel Saturated |
56 |
Quaternary Analog Channel Saturated |
57 |
Quinary Analog Channel Saturated |
58 |
Secondary Analog Channel Fixed |
59 |
Tertiary Analog Channel Fixed |
60 |
Quaternary Analog Channel Fixed |
61 |
Quinary Analog Channel Fixed |
62 |
Simulation active |
63 |
The device is in simulation mode and the level output is not representative of the process. |
64 |
Non-Volatile memory failure |
65 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
66 |
Volatile memory error |
67 |
The RAM memory check is invalid or maybe corrupt |
68 |
Watchdog reset executed |
69 |
A watchdog reset has been performed |
70 |
Voltage conditions out of range |
71 |
A voltage condition is outside its allowable range |
72 |
Environmental conditions out of range |
73 |
An internal or environmental condition is beyond acceptable limits. |
74 |
Electronic failure |
75 |
A hardware problem not related to the sensor has been detected. |
76 |
Subdevice list changed |
77 |
Duplicate master detected |
78 |
Capacity Denied |
79 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
80 |
Bandwidth allocation pending |
81 |
Block transfer pending |
82 |
Battery life |
83 |
Percent range |
84 |
Loop current |
85 |
Primary variable |
86 |
Secondary variable |
87 |
Tertiary variable |
88 |
Quaternary variable |
89 |
Read receive time |
90 |
Write date and time |
91 |
Non-Volatile Clock |
92 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
93 |
Clock Uninitialized |
94 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
95 |
None |
96 |
No restrictions |
97 |
SI Only |
98 |
Restricted to SI Unit codes only |
99 |
Process automation device |
100 |
Discrete device |
101 |
Hybrid:Process automation+discrete |
102 |
I/O System |
103 |
WirelessHART Process automation device |
104 |
WirelessHART Discrete device |
105 |
WirelessHART Process automation+discrete |
106 |
WirelessHART Gateway |
107 |
WirelessHART Access point |
108 |
WirelessHART Process adapter |
109 |
WirelessHART Discrete adapter |
110 |
WirelessHART enabled handheld/portable maintenance tool |
111 |
Device Profile |
112 |
US |
113 |
United States of America |
114 |
JP |
115 |
Japan |
116 |
DE |
117 |
Germany |
118 |
FR |
119 |
France |
120 |
ES |
121 |
Spain |
122 |
RU |
123 |
Russian Federation |
124 |
CN |
125 |
People's Republic of China |
126 |
Secondary Master |
127 |
Primary Master |
128 |
Device Diagnostic Status 0 |
129 |
Device Diagnostic Status 1 |
130 |
I/O and Subdevice Status |
131 |
WirelessHART Status |
132 |
Time Set Option |
133 |
Real Time Clock Flags |
134 |
Country |
135 |
Country of intended device installation |
136 |
SI Unit Control |
137 |
Indicates if device should only display SI unit codes |
138 |
Time Stamp |
139 |
Relative time value on network |
140 |
8u |
141 |
Dynamic Variables Returned for Device Variables |
142 |
Command Response Truncated |
143 |
Configuration Change Counter Mismatch |
144 |
Status bytes mismatch |