0 |
SC200 Module-Inductive Conductivity |
1 |
S/cm |
2 |
ppt |
3 |
Temperature Error |
4 |
Sample Warning |
5 |
? CAL Warning |
6 |
? Meas. Warning |
7 |
Safety Warning |
8 |
Reagent Warning |
9 |
Maint. Required Warning |
10 |
Meas. CAL Error |
11 |
Electronic Adjustment Error |
12 |
Cleaning Error |
13 |
Measuring Module Error |
14 |
Re-initialization Error |
15 |
Hardware Error |
16 |
Internal COMM Error |
17 |
Humidity Error |
18 |
SENS OUT RANGE |
19 |
MEAS TOO HIGH |
20 |
MEAS TOO LOW |
21 |
ZERO TOO HIGH |
22 |
ZERO TOO LOW |
23 |
TEMP TOO HIGH |
24 |
TEMP TOO LOW |
25 |
ADC FAILURE |
26 |
SENSOR MISSING |
27 |
REPLACE SENSOR |
28 |
CAL IN PROGRESS |
29 |
OUTPUTS ON HOLD |
30 |
WRONG LINEAR TC TABLE |
31 |
WRONG TC TABLE |
32 |
WRONG USER CONC TBL |
33 |
WRNG BLT-IN TEMP TBL |
34 |
WRNG BLT-IN CONC TBL |
35 |
CAL OVERDUE |
36 |
NOT CALIBRATED |
37 |
Cond. uS/cm |
38 |
Temp C |
39 |
Conc. % |
40 |
TDS ppm |
41 |
Salinity ppt |
42 |
Cond. mS/cm |
43 |
Cond. S/cm |
44 |
Temp F |
45 |
Temp C |
46 |
Temp Units |
47 |
Temperature |
48 |
Temp USL |
49 |
Temp LSL |
50 |
Temp Min Span |
51 |
Temp Damping |
52 |
Temp Class |
53 |
Temp Data Quality |
54 |
Temp Limit Status |
55 |
Temp Family Status |
56 |
Temp Sensor S/N |
57 |
Temp F |
58 |
Conductivity uS/cm |
59 |
Cond uS/cm Unit |
60 |
Cond uS/cm Value |
61 |
Cond uS/cm USL |
62 |
Cond uS/cm LSL |
63 |
Cond uS/cm Min Span |
64 |
Cond uS/cm Damping |
65 |
Cond uS/cm Class |
66 |
Cond uS/cm Data Quality |
67 |
Cond uS/cm Limit Status |
68 |
Cond uS/cm Family Stat. |
69 |
Cond uS/cm Sensor S/N |
70 |
Conductivity mS/cm |
71 |
Cond mS/cm Unit |
72 |
Cond mS/cm Value |
73 |
Cond mS/cm USL |
74 |
Cond mS/cm LSL |
75 |
Cond mS/cm Min Span |
76 |
Cond mS/cm Damping |
77 |
Cond mS/cm Class |
78 |
Cond mS/cm Data Quality |
79 |
Cond mS/cm Limit Status |
80 |
Cond mS/cm Family Status |
81 |
Cond mS/cm Sensor S/N |
82 |
Conductivity S/cm |
83 |
Cond S/cm Unit |
84 |
Cond S/cm Value |
85 |
Cond S/cm USL |
86 |
Cond S/cm LSL |
87 |
Cond S/cm Min Span |
88 |
Cond S/cm Damping |
89 |
Cond S/cm Class |
90 |
Cond S/cm Data Quality |
91 |
Cond S/cm Limit Status |
92 |
Cond S/cm Family Status |
93 |
Cond S/cm Sensor S/N |
94 |
TDS |
95 |
TDS Unit |
96 |
TDS Value |
97 |
TDS USL |
98 |
TDS LSL |
99 |
TDS Min Span |
100 |
TDS Damping |
101 |
TDS Class |
102 |
TDS Data Quality |
103 |
TDS Limit Status |
104 |
TDS Family Status |
105 |
TDS Sensor S/N |
106 |
Salinity Unit |
107 |
Salinity Value |
108 |
Salinity USL |
109 |
Salinity LSL |
110 |
Salinity Min Span |
111 |
Salinity Damping |
112 |
Salinity Class |
113 |
Salinity Data Quality |
114 |
Salinity Limit Status |
115 |
Salinity Family Status |
116 |
Salinity Sensor S/N |
117 |
Concentration |
118 |
Conc Unit |
119 |
Conc Value |
120 |
Conc USL |
121 |
Conc LSL |
122 |
Conc Min Span |
123 |
Conc Damping |
124 |
Conc Class |
125 |
Conc Data Quality |
126 |
Conc Limit Status |
127 |
Conc Family Status |
128 |
Conc Sensor S/N |
129 |
PV Units |
130 |
Temp C |
131 |
Temperature Units C. |
132 |
Temp F |
133 |
Temperature Units F. |
134 |
The measured value of Temperature in C. |
135 |
5.1f |
136 |
The measured value of Temperature in F. |
137 |
14.4f |
138 |
Temp. Damping |
139 |
8d |
140 |
PV Class |
141 |
PV Data Quality |
142 |
PV Limit Status |
143 |
PV Family Status |
144 |
PV Sensor S/N |
145 |
uS/cm |
146 |
Conductivity uS/Cm unit. |
147 |
The measured value of Conductivity uS/cm. |
148 |
uS/cm USL |
149 |
uS/cm LSL |
150 |
uS/cm Min Span |
151 |
uS/cm Damping |
152 |
mS/cm |
153 |
Conductivity mS/Cm unit |
154 |
The measured value of Conductivity mS/cm. |
155 |
mS/cm USL |
156 |
mS/cm LSL |
157 |
mS/cm Min Span |
158 |
mS/cm Damping |
159 |
Conductivity S/Cm unit. |
160 |
The measured value of Conductivity S/cm. |
161 |
S/cm USL |
162 |
S/cm LSL |
163 |
S/cm Min Span |
164 |
S/cm Damping |
165 |
ppm |
166 |
Conductivity TDS unit. |
167 |
The measured value of TDS. |
168 |
Salinity ppt unit. |
169 |
Salinity |
170 |
The measured value of Salinity. |
171 |
% |
172 |
Concentration % unit. |
173 |
CONC |
174 |
The measured value of CONC. |
175 |
CONC USL |
176 |
CONC LSL |
177 |
CONC Min Span |
178 |
CONC Damping |
179 |
Location String |
180 |
Location or Name of Module. |
181 |
Appl. Code Ver. |
182 |
Application Code Version times 100. |
183 |
Boot Code Ver. |
184 |
Boot Code Version times 100. |
185 |
Module S/N |
186 |
Module serial number. |
187 |
User Temp C |
188 |
Manual Temperature Compensation Value in C. |
189 |
User Temp F |
190 |
Manual Temperature Compensation Value in F. |
191 |
Temp Raw Value |
192 |
The raw, unscaled temperature value. |
193 |
6.4f |
194 |
Temp Offset Value |
195 |
The Offset temperature value. |
196 |
Cell Constant |
197 |
Conductivity Cell Constant. |
198 |
4.2f |
199 |
1/cm |
200 |
Linear Temp Ref. |
201 |
Linear Temperature Compensation Reference Value. |
202 |
Linear Temp Slope |
203 |
Linear Temperature Compensation Slope. |
204 |
%/C |
205 |
TDS Factor |
206 |
TDS Conversion Factor. |
207 |
5.2f |
208 |
ppm/uS |
209 |
Raw Cond. Value |
210 |
Uncompensated Raw Conductivity Value. |
211 |
Raw Cond. Signal |
212 |
Raw Conductivity Signal. |
213 |
T Factor |
214 |
T Conversion Factor. |
215 |
6.1f |
216 |
Ohm |
217 |
Parameter Type |
218 |
Measurement Parameter Type-Conductivity, TDS, Salinity, or Concentration. |
219 |
Conductivity |
220 |
Temp Units C/F |
221 |
Temperature Units C/F. |
222 |
Display Format |
223 |
The display format (resolution) for the measured value on the local controller. |
224 |
AUTO |
225 |
X.XXX |
226 |
XX.XX |
227 |
XXX.X |
228 |
XXXX |
229 |
Filter |
230 |
Filter time constant applied to the measured value. |
231 |
3d |
232 |
Temp Element Type |
233 |
PT-100 |
234 |
PT-1000 |
235 |
MANUAL |
236 |
Meas. Units Auto Display |
237 |
Conductivity measurement unit displayed in Auto mode. |
238 |
Displayed Cond. Unit |
239 |
List of controller displayed conductivity measurement units. |
240 |
Sensor Log Interval |
241 |
The interval at which data will be written to the sensor data log. |
242 |
5 Sec. |
243 |
30 Sec. |
244 |
1 Min. |
245 |
2 Min. |
246 |
5 Min. |
247 |
10 Min. |
248 |
15 Min. |
249 |
30 Min. |
250 |
60 Min. |
251 |
Sensor Running Days |
252 |
Number of days the sensor has been in operation. |
253 |
5d |
254 |
Cond Temp Comp Type |
255 |
Conductivity Temperature Compensation Type. |
256 |
Linear |
257 |
Natural Water |
258 |
Temp Table |
259 |
NONE |
260 |
Conc Temp Comp Type |
261 |
Concentration Temperature Compensation Type. |
262 |
TDS Temp Comp Type |
263 |
TDS Temperature Compensation Type. |
264 |
Conc. Comp. Type |
265 |
Concentration Compensation Type. |
266 |
Built-In |
267 |
User Table |
268 |
Conc. Built-In |
269 |
Built-In Concentration Compensation selection list. |
270 |
H3PO4 0-40% |
271 |
HCl 0-18% |
272 |
HCl 22-36% |
273 |
NaOH 0-16% |
274 |
CaCl2 0-22% |
275 |
HNO3 0-28% |
276 |
HNO3 36-96% |
277 |
H2SO4 0-30% |
278 |
H2SO4 40-80% |
279 |
H2SO4 93-99% |
280 |
TDS Factor Type |
281 |
TDS Factor Type Selection. |
282 |
NaCl |
283 |
Custom |
284 |
CAL Reminder Period |
285 |
The period until a calibration is required. |
286 |
OFF |
287 |
1 DAY |
288 |
7 DAYS |
289 |
30 DAYS |
290 |
60 DAYS |
291 |
90 DAYS |
292 |
6 MONTHS |
293 |
9 MONTHS |
294 |
1 YEAR |
295 |
2 YEARS |
296 |
CAL Days |
297 |
The number of days since the last calibration. |
298 |
6d |
299 |
Process Events |
300 |
Process Event Flags. |
301 |
Normal Operation |
302 |
Active Outputs |
303 |
Hold OUtputs |
304 |
Transfer Value |
305 |
Analog Sensor S/N |
306 |
The serial number of the attached analog sensor. |
307 |
Classified Status 1 |
308 |
Status Flags for Measurements 0-3. |
309 |
CAL in Progress |
310 |
The device has been placed in a calibration mode. The measurements may not be valid. |
311 |
Cleaning In Progress |
312 |
The device has been placed in a cleaning mode. The measurements may not be valid. |
313 |
Service/Maint. Menu |
314 |
The device has been placed in a service or maintenance mode in which the measurements may not be valid. |
315 |
Common Error |
316 |
Meas. 0 Quality Bad |
317 |
Meas. 0 Low Limit |
318 |
Meas. 0 High Limit |
319 |
Meas. 1 Quality Bad |
320 |
Meas. 1 Low Limit |
321 |
Meas. 1 High Limit |
322 |
Meas. 2 Quality Bad |
323 |
Meas. 2 Low Limit |
324 |
Meas. 2 High Limit |
325 |
Meas. 3 Quality Bad |
326 |
Meas. 3 Low Limit |
327 |
Meas. 3 High Limit |
328 |
Classified Status 2 |
329 |
Status Flags for Measurements 4-7. |
330 |
Reserved for Future Use |
331 |
Meas. 4 Quality Bad |
332 |
Meas. 4 Low Limit |
333 |
Meas. 4 High Limit |
334 |
Meas. 5 Quality Bad |
335 |
Meas. 5 Low Limit |
336 |
Meas. 5 High Limit |
337 |
Meas. 6 Quality Bad |
338 |
Meas. 6 Low Limit |
339 |
Meas. 6 High Limit |
340 |
Meas. 7 Quality Bad |
341 |
Meas. 7 Low Limit |
342 |
Meas. 7 High Limit |
343 |
Classified Status 3 |
344 |
Status Flags for Measurements 8-11. |
345 |
Meas. 8 Quality Bad |
346 |
Meas. 8 Low Limit |
347 |
Meas. 8 High Limit |
348 |
Meas. 9 Quality Bad |
349 |
Meas. 9 Low Limit |
350 |
Meas. 9 High Limit |
351 |
Meas. 10 Quality Bad |
352 |
Meas. 10 Low Limit |
353 |
Meas. 10 High Limit |
354 |
Meas. 11 Quality Bad |
355 |
Meas. 11 Low Limit |
356 |
Meas. 11 High Limit |
357 |
Classified Status 4 |
358 |
Status Flags for Measurements 12-15. |
359 |
Meas. 12 Quality Bad |
360 |
Meas. 12 Low Limit |
361 |
Meas. 12 high Limit |
362 |
Meas. 13 Quality Bad |
363 |
Meas. 13 Low Limit |
364 |
Meas. 13 High Limit |
365 |
Meas. 14 Quality Bad |
366 |
Meas. 14 Low Limit |
367 |
Meas. 14 High Limit |
368 |
Meas. 15 Quality Bad |
369 |
Meas. 15 Low Limit |
370 |
Meas. 15 High Limit |
371 |
Hach-Lange Logo |
372 |
Sensor Image |
373 |
Concentration % |
374 |
Sensor Bar Graph |
375 |
PV |
376 |
Conductivity Module - ICO |
377 |
Device Variables |
378 |
Identification |
379 |
Sensor Description |
380 |
Primary Variable |
381 |
Measured Values |
382 |
HART Tags |
383 |
Device Info. |
384 |
Revisions |
385 |
Sensor Information |
386 |
Status |
387 |
Diagnostics |
388 |
Device Errors |
389 |
Device Warnings |
390 |
Classified Error |
391 |
Sensor Diagnostics |
392 |
Conductivity Setup |
393 |
TDS Setup |
394 |
Salinity Setup |
395 |
Temp Sensor Setup |
396 |
Concentration Setup |
397 |
Temperature Setup |
398 |
HART Setup |
399 |
Sensor Setup |
400 |
TDS Setup |
401 |
Upload Variables |
402 |
Location |
403 |
sc200 name or location. |
404 |
Application Code Version. |
405 |
Boot Code Version. |
406 |
Serial Number |
407 |
sc200 controller serial number. |
408 |
sc200 controller device warning flags. |
409 |
Overfeed Timer |
410 |
The Overfeed Timer is active. |
411 |
Restart Software |
412 |
Restart to Accept sc200 Software. |
413 |
Network COMM Loss |
414 |
Network Communications Loss. |
415 |
Input 1 triggered |
416 |
Discrete Input 1 Triggered. |
417 |
Input 2 triggered |
418 |
Discrete Input 2 Triggered. |
419 |
Input 3 triggered |
420 |
Discrete Input 3 Triggered. |
421 |
sc200 controller device error flags. |
422 |
Flash Failure |
423 |
Transfer Output 1 |
424 |
Sets the transfer value of Output 1. |
425 |
mA |
426 |
Transfer Output 2 |
427 |
Sets the transfer value of Output 2. |
428 |
LRV Output 1 |
429 |
Sets the minimum output value. |
430 |
LRV Output 2 |
431 |
URV Output 1 |
432 |
Sets the maximum output value. |
433 |
URV Output 2 |
434 |
Knee Value Out 1 |
435 |
Bilinear knee value. |
436 |
Knee Value Out 2 |
437 |
Knee Current Out 1 |
438 |
Bilinear knee current in percent. |
439 |
6.2f |
440 |
Knee Current Out 2 |
441 |
50% Log Output 1 |
442 |
Log 50% setting. |
443 |
50% Log Output 2 |
444 |
PID Man Set Out 1 |
445 |
Sets the PID manual output value (0.0 to 100.0 %). |
446 |
PID Man Set Out 2 |
447 |
PID Setpt Out 1 |
448 |
Sets the PID control setpoint for Output 1. |
449 |
PID Setpt Out 2 |
450 |
Sets the PID control setpoint for Output 2. |
451 |
PID Prop Band Out 1 |
452 |
Sets the PID proportional band for Output 1. |
453 |
PID Prop Band Out 2 |
454 |
Sets the PID proportional band for Output 2. |
455 |
Error Hold Mode |
456 |
Holds Outputs at last known value or switches to Transfer mode when sensor loses communication with controller. |
457 |
Hold Outputs |
458 |
Transfer Outputs to Predefined Value |
459 |
Meas. Select Output 1 |
460 |
Selection list of sensor measurements. |
461 |
Meas. Select Output 2 |
462 |
Type Output 1 |
463 |
Selection list of output modes. |
464 |
PID |
465 |
Logarithmic |
466 |
Bilinear |
467 |
Type Output 2 |
468 |
Filter Output 1 |
469 |
Time constant Output 1. |
470 |
Filter Output 2 |
471 |
Time constant Output 2. |
472 |
0/4 mA Sel Out 1 |
473 |
Minimum current selection Output 1. |
474 |
0 mA |
475 |
4 mA |
476 |
0/4 mA Sel Out 2 |
477 |
Minimum current selection Output 2. |
478 |
PID Mode Output 1 |
479 |
Auto/Manual mode selection for Output 1. |
480 |
Auto |
481 |
Manual |
482 |
PID Mode Output 2 |
483 |
Auto/Manual mode selection for Output 2. |
484 |
Phase Output 1 |
485 |
Direct/Reverse phase selection Output 1. |
486 |
Direct |
487 |
Reverse |
488 |
Phase Output 2 |
489 |
Direct/Reverse phase selection Output 2. |
490 |
PID Integral Out 1 |
491 |
Integral time in seconds Output 1. |
492 |
4d |
493 |
PID Integral Out 2 |
494 |
Integral time in seconds Output 2. |
495 |
PID Derivative Out 1 |
496 |
Derivative time in seconds Output 1. |
497 |
PID Derivative Out 2 |
498 |
Derivative time in seconds Output 2. |
499 |
PID Transit Out 1 |
500 |
Stops all PID control for a selected period of time. |
501 |
PID Transit Out 2 |
502 |
Range Output 1 |
503 |
Selection List of sensor ranges. |
504 |
Range Output 2 |
505 |
High Alarm A |
506 |
Sets the High Alarm setpoint for Alarm A. |
507 |
High Alarm B |
508 |
Sets the High Alarm setpoint for Alarm B. |
509 |
High Alarm C |
510 |
Sets the High Alarm setpoint for Alarm C. |
511 |
High Alarm D |
512 |
Sets the High Alarm setpoint for Alarm D. |
513 |
Low Alarm A |
514 |
Sets the Low Alarm setpoint for Alarm A. |
515 |
Low Alarm B |
516 |
Sets the Low Alarm setpoint for Alarm B. |
517 |
Low Alarm C |
518 |
Sets the Low Alarm setpoint for Alarm C. |
519 |
Low Alarm D |
520 |
Sets the Low Alarm setpoint for Alarm D. |
521 |
High Deadband A |
522 |
Sets the High Alarm deadband for Alarm A. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint |
523 |
High Deadband B |
524 |
Sets the High Alarm deadband for Alarm B. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint |
525 |
High Deadband C |
526 |
Sets the High Alarm deadband for Alarm C. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint |
527 |
High Deadband D |
528 |
Sets the High Alarm deadband for Alarm D. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint |
529 |
Low Deadband A |
530 |
Sets the Low Alarm deadband for Alarm A. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint |
531 |
Low Deadband B |
532 |
Sets the Low Alarm deadband for Alarm B. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint |
533 |
Low Deadband C |
534 |
Sets the Low Alarm deadband for Alarm C. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint |
535 |
Low Deadband D |
536 |
Sets the Low Alarm deadband for Alarm D. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint |
537 |
Setpoint Control A |
538 |
Sets the Controller Setpoint for Relay A. |
539 |
Setpoint Control B |
540 |
Sets the Controller Setpoint for Relay B. |
541 |
Setpoint Control C |
542 |
Sets the Controller Setpoint for Relay C. |
543 |
Setpoint Control D |
544 |
Sets the Controller Setpoint for Relay D. |
545 |
Deadband Control A |
546 |
Proportional Band A |
547 |
Sets the Controller Deadband/Proportional Band for Relay A. |
548 |
Deadband Control B |
549 |
Proportional Band B |
550 |
Sets the Controller Deadband/Proportional Band for Relay B. |
551 |
Deadband Control C |
552 |
Proportional Band C |
553 |
Sets the Controller Deadband/Proportional Band for Relay C. |
554 |
Deadband Control D |
555 |
Proportional Band D |
556 |
Sets the Controller Deadband/Proportional Band for Relay D. |
557 |
Setpoint Event A |
558 |
Sets the Event Controller Setpoint for Relay A. |
559 |
Setpoint Event B |
560 |
Sets the Event Controller Setpoint for Relay B. |
561 |
Setpoint Event C |
562 |
Sets the Event Controller Setpoint for Relay C. |
563 |
Setpoint Event D |
564 |
Sets the Event Controller Setpoint for Relay D. |
565 |
Deadband A |
566 |
Dead Zone A |
567 |
Sets the Controller Deadband/Dead Zone for Relay B. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint. Dead Zone is a band around the setpoint. In this band the controller does not change the output signal. |
568 |
Deadband B |
569 |
Dead Zone B |
570 |
Sets the Controller Deadband/Dead Zone for Relay B. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint. Dead Zone is a band around the setpoint. In this band the controller does not change the output signal |
571 |
Deadband C |
572 |
Dead Zone C |
573 |
Sets the Controller Deadband/Dead Zone for Relay C. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint. Dead Zone is a band around the setpoint. In this band the controller does not change the output signal |
574 |
Deadband D |
575 |
Dead Zone D |
576 |
Sets the Controller Deadband/Dead Zone for Relay D. Deadband is a hysteresis so the relay will not swing unregulated when the process value converges to the setpoint. Dead Zone is a band around the setpoint. In this band the controller does not change the output signal |
577 |
Manual Value A |
578 |
Sets the Manual control output level (%) Relay A. |
579 |
Manual Value B |
580 |
Sets the Manual control output level (%) Relay B. |
581 |
Manual Value C |
582 |
Sets the Manual control output level (%) Relay C. |
583 |
Manual Value D |
584 |
Sets the Manual control output level (%) Relay D. |
585 |
Pulse Width A |
586 |
Period A |
587 |
Sets the period/pulse width for pwm/freq control Relay A. |
588 |
4.1f |
589 |
Pulse Width B |
590 |
Period B |
591 |
Sets the period/pulse width for pwm/freq control Relay B. |
592 |
Pulse Width C |
593 |
Period C |
594 |
Sets the period/pulse width for pwm/freq control Relay C. |
595 |
Pulse Width D |
596 |
Period D |
597 |
Sets the period/pulse width for pwm/freq control Relay 4. |
598 |
Min Pulse Width A |
599 |
Min Pulses A |
600 |
Sets the minimum pulse width for PWM in seconds (0.1 to Max Pulse Width) or sets the minimum number of pulses for Frequency control (0.001 to Max Number of Pulses) for Relay A. |
601 |
6.3f |
602 |
Min Pulse Width B |
603 |
Min Pulses B |
604 |
Sets the minimum pulse width for PWM in seconds (0.1 to Max Pulse Width) or sets the minimum number of pulses for Frequency control (0.001 to Max Number of Pulses) for Relay B. |
605 |
Min Pulse Width C |
606 |
Min Pulses C |
607 |
Sets the minimum pulse width for PWM in seconds (0.1 to Max Pulse Width) or sets the minimum number of pulses for Frequency control (0.001 to Max Number of Pulses) for Relay C. |
608 |
Min Pulse Width D |
609 |
Min Pulses D |
610 |
Sets the minimum pulse width for PWM in seconds (0.1 to Max Pulse Width) or sets the minimum number of pulses for Frequency control (0.001 to Max Number of Pulses) for Relay D. |
611 |
Max Pulse Width A |
612 |
Max Pulses A |
613 |
Sets the maximum pulse width for PWM in seconds (Min Pulse Width to Period) or sets the maximum number of pulses for Frequency control (Min Number of Pulses to 60 ) for Relay A. |
614 |
Max Pulse Width B |
615 |
Max Pulses B |
616 |
Sets the maximum pulse width for PWM in seconds (Min Pulse Width to Period) or sets the maximum number of pulses for Frequency control (Min Number of Pulses to 60 ) for Relay B. |
617 |
Max Pulse Width C |
618 |
Max Pulses C |
619 |
Sets the maximum pulse width for PWM in seconds (Min Pulse Width to Period) or sets the maximum number of pulses for Frequency control (Min Number of Pulses to 60 ) for Relay C. |
620 |
Max Pulse Width D |
621 |
Max Pulses D |
622 |
Sets the maximum pulse width for PWM in seconds (Min Pulse Width to Period) or sets the maximum number of pulses for Frequency control (Min Number of Pulses to 60 ) for Relay D. |
623 |
Calculated Value |
624 |
sc200 Calculated Value |
625 |
Language |
626 |
sc200 language selection list. |
627 |
English |
628 |
German |
629 |
Spanish |
630 |
French |
631 |
Italian |
632 |
Netherland |
633 |
Danish |
634 |
Swedish |
635 |
Chinese |
636 |
Polish |
637 |
Japanese |
638 |
Korean |
639 |
Portuguese |
640 |
Russian |
641 |
Hungarian |
642 |
Romanian |
643 |
Czech |
644 |
Greek |
645 |
Slovenian |
646 |
Polish UTF8 |
647 |
Date Format |
648 |
sc200 Date Format. |
649 |
YYYY-MM-DD 24h |
650 |
YYYY-MM-DD 12h |
651 |
DD/MM/YYYY 24h |
652 |
DD/MM/YYYY 12h |
653 |
MM/DD/YYYY 24h |
654 |
MM/DD/YYYY 12h |
655 |
Display Contrast |
656 |
sc200 Display Contrast, 1 to 9. |
657 |
Calc Log Mode |
658 |
sc200 Calculated Value logging mode |
659 |
Snap Shot |
660 |
Average |
661 |
Maximum |
662 |
Minimum |
663 |
Calc Log Interval |
664 |
sc200 Calculated Value logging interval |
665 |
5 sec. |
666 |
30 sec. |
667 |
Calc Math Formula |
668 |
The formula selection for the Calculated Value. |
669 |
None |
670 |
X/Y |
671 |
X+Y |
672 |
X-Y |
673 |
(X/Y)% |
674 |
(X/Y)/2 |
675 |
X*Y |
676 |
(X-Y)%/X |
677 |
Discrete Input 1 |
678 |
Input State 1 |
679 |
Discrete Input 2 |
680 |
Input State 2 |
681 |
Discrete Input 3 |
682 |
Input State 3 |
683 |
Modbus Stats Clear |
684 |
Clears statistics for Modbus communication. |
685 |
Normal |
686 |
Clear |
687 |
Measurement A |
688 |
Measurement selection list for Relay A. |
689 |
Measurement B |
690 |
Measurement selection list for Relay B. |
691 |
Measurement C |
692 |
Measurement selection list for Relay C. |
693 |
Measurement D |
694 |
Measurement selection list for Relay D. |
695 |
Type A |
696 |
Type selection list for Relay A. |
697 |
Alarm |
698 |
Feeder Control |
699 |
Warning |
700 |
Event Control |
701 |
PWM Control |
702 |
Freq Control |
703 |
Type B |
704 |
Type selection list for Relay B. |
705 |
Type C |
706 |
Type selection list for Relay C. |
707 |
Type D |
708 |
Type selection list for Relay D. |
709 |
Transfer Set A |
710 |
State selection for Relay A. |
711 |
Inactive |
712 |
Active |
713 |
Transfer Set B |
714 |
State selection for Relay B. |
715 |
Transfer Set C |
716 |
State selection for Relay C. |
717 |
Transfer Set D |
718 |
State selection for Relay D. |
719 |
Alarm On Delay A |
720 |
Turn on time delay for Relay A. |
721 |
Alarm On Delay B |
722 |
Turn on time delay for Relay B. |
723 |
Alarm On Delay C |
724 |
Turn on time delay for Relay C. |
725 |
Alarm On Delay D |
726 |
Turn on time delay for Relay D. |
727 |
Alarm Off Delay A |
728 |
Turn off time delay for Relay A. |
729 |
Alarm Off Delay B |
730 |
Turn off time delay for Relay B. |
731 |
Alarm Off Delay C |
732 |
Turn off time delay for Relay C. |
733 |
Alarm Off Delay D |
734 |
Turn off time delay for Relay D. |
735 |
Phase Control A |
736 |
Select direct/reverse for Relay A. |
737 |
Low |
738 |
High |
739 |
Phase Control B |
740 |
Select direct/reverse for Relay B. |
741 |
Phase Control C |
742 |
Select direct/reverse for Relay C. |
743 |
Phase Control D |
744 |
Select direct/reverse for Relay D. |
745 |
Overfeed Timer A |
746 |
Sets a time period for de-activating an active relay if the process setpoint cannot be reached. Once an overfeed alarm is present, it must be manually reset. |
747 |
Overfeed Timer B |
748 |
Overfeed Timer C |
749 |
Overfeed Timer D |
750 |
On Delay A |
751 |
Sets a delay time for the relay to turn on. |
752 |
On Delay B |
753 |
On Delay C |
754 |
On Delay D |
755 |
Off Delay A |
756 |
Sets a delay time for the relay to turn off. |
757 |
Off Delay B |
758 |
Off Delay C |
759 |
Off Delay D |
760 |
Reset Overfeed Timer A |
761 |
Resets the Overfeed Timer for Relay A |
762 |
Undefined |
763 |
Non-Zero Resets |
764 |
Reset Overfeed Timer B |
765 |
Resets the Overfeed Timer for Relay B |
766 |
Reset Overfeed Timer C |
767 |
Resets the Overfeed Timer for Relay C |
768 |
Reset Overfeed Timer D |
769 |
Resets the Overfeed Timer for Relay D |
770 |
Max On Time A |
771 |
Sets the maximum time the relay can remain on. |
772 |
Max On Time B |
773 |
Max On Time C |
774 |
Max On Time D |
775 |
Min On Time A |
776 |
Sets the time the relay will remain on independent from the measured value. |
777 |
Min On Time B |
778 |
Min On Time C |
779 |
Min On Time D |
780 |
Max Off Time A |
781 |
Sets the maximum time the relay can remain off. |
782 |
Max Off Time B |
783 |
Max Off Time C |
784 |
Max Off Time D |
785 |
Min Off Time A |
786 |
Sets the time the relay will remain off independent from the measured value. |
787 |
Min Off Time B |
788 |
Min Off Time C |
789 |
Min Off Time D |
790 |
Warning Level A |
791 |
Sets the level for device warning activation. |
792 |
Warning Level B |
793 |
Warning Level C |
794 |
Warning Level D |
795 |
PWM Mode A |
796 |
Freq Mode A |
797 |
Auto, the relay output works as a PID controller. Manual, the relay output has an On/Off ratio as set in the PI Manual setting. |
798 |
PWM Mode B |
799 |
Freq Mode B |
800 |
PWM Mode C |
801 |
Freq Mode C |
802 |
PWM Mode D |
803 |
Freq Mode D |
804 |
PWM Integral A |
805 |
Freq Integral A |
806 |
Sets the integral part of the PID controller. |
807 |
PWM Integral B |
808 |
Freq Integral B |
809 |
PWM Integral C |
810 |
Freq Integral C |
811 |
PWM Integral D |
812 |
Freq Integral D |
813 |
Range A |
814 |
Range B |
815 |
Range C |
816 |
Range D |
817 |
Fail Safe Mode A |
818 |
Fail Safe Mode 'ON' implies the relay is energized in the non-alarm state. |
819 |
NO |
820 |
YES |
821 |
Fail Safe Mode B |
822 |
Fail Safe Mode C |
823 |
Fail Safe Mode D |
824 |
Net Port % Good Msg |
825 |
Percentage of good messages on the Network Card Port. |
826 |
Svc Port % Good Msg |
827 |
Percentage of good messages on the Service Port. |
828 |
Port 1 % Good Msg |
829 |
Percentage of good messages on Port 1. |
830 |
Port 2 % Good Msg |
831 |
Percentage of good messages on Port 2. |
832 |
Port 3 % Good Msg |
833 |
Percentage of good messages on Port 3. |
834 |
Port 4 % Good Msg |
835 |
Percentage of good messages on Port 4. |
836 |
Current Temperature |
837 |
Internal temperature of the sc200. |
838 |
12V Supply Voltage |
839 |
Measured value of the sc200 12 volt supply. |
840 |
3.3V Supply Current |
841 |
Total 3.3V Supply current (A). |
842 |
5.3f |
843 |
Amps |
844 |
12V Supply Current |
845 |
Total 12V Supply current (A). |
846 |
Port 3 Supply Current |
847 |
Smart Sensor 1 - 12V Supply current (A). |
848 |
Port 4 Supply Current |
849 |
Smart Sensor 2 - 12V Supply current (A). |
850 |
Port 1 Supply Current |
851 |
Analog Sensor 1 - 12V Supply current (A). |
852 |
Port 2 Supply Current |
853 |
Analog Sensor 2 - 12V Supply current (A). |
854 |
Max Temperature |
855 |
The daily maximum sc200 internal temperature in C. |
856 |
Min Temperature |
857 |
The daily minimum sc200 internal temperature in C. |
858 |
12V Ground Potential |
859 |
The measured voltage between A/D common and the 12 volt supply ground. |
860 |
Output 1 Value |
861 |
Display or Set level on Output 1. |
862 |
Output 2 Value |
863 |
Display or Set level on Output 2. |
864 |
Off |
865 |
Sensor 1 |
866 |
Sensor 2 |
867 |
Network Module |
868 |
sc200 |
869 |
Network Errors |
870 |
Sensor communication error flags. |
871 |
Sensor 1 Com Err |
872 |
Sensor 2 Com Err |
873 |
Network Status |
874 |
Sensor communication and relay status. |
875 |
Sensor 1 Connected |
876 |
Sensor 2 Connected |
877 |
Relay A Active |
878 |
Relay B Active |
879 |
Relay C Active |
880 |
Relay D Active |
881 |
Set Defaults |
882 |
Test Enable Out 1 |
883 |
Enables test of Output 1. |
884 |
Disabled |
885 |
Enabled |
886 |
Test Enable Out 2 |
887 |
Enables test of Output 2. |
888 |
Cal 4 mA Out 1 |
889 |
Calibration counts for 4 mA Output 1. |
890 |
Counts |
891 |
Cal 4 mA Out 2 |
892 |
Calibration counts for 4 mA Output 2. |
893 |
Cal 20 mA Out 1 |
894 |
Calibration counts for 20 mA Output 1. |
895 |
Cal 20 mA Out 2 |
896 |
Calibration counts for 20 mA Output 2. |
897 |
Test Relay A Enable |
898 |
Enables test of Relay A. |
899 |
Test Relay B Enable |
900 |
Enables test of Relay B. |
901 |
Test Relay C Enable |
902 |
Enables test of Relay C. |
903 |
Test Relay D Enable |
904 |
Enables test of Relay D. |
905 |
Test Relay A Value |
906 |
Sets the test state for Relay A. |
907 |
Test Relay B Value |
908 |
Sets the test state for Relay B. |
909 |
Test Relay C Value |
910 |
Sets the test state for Relay C. |
911 |
Test Relay D Value |
912 |
Sets the test state for Relay D. |
913 |
Discrete Input 1 Mode |
914 |
The Modes ON/High and OFF/Low are set by jumpers per the Instruction Manual. |
915 |
Active ON/High |
916 |
Active OFF/Low |
917 |
Discrete Input 2 Mode |
918 |
Discrete Input 3 Mode |
919 |
DI 1 Warning Enable |
920 |
When Enabled, a sc200 Warning will be generated when the Input is Active. |
921 |
DI 2 Warning Enable |
922 |
DI 3 Warning Enable |
923 |
DI 1 Hold Mode |
924 |
Selection list for the Discrete Input's Output Hold Mode. |
925 |
Hold |
926 |
Transfer |
927 |
DI 2 Hold Mode |
928 |
DI 3 Hold Mode |
929 |
DI 1 On Delay (0-999) |
930 |
The delay in seconds before the Input goes Active. |
931 |
DI 2 On Delay (0-999) |
932 |
DI 3 On Delay (0-999) |
933 |
DI 1 Off Delay (0-999) |
934 |
The delay in seconds before the Input goes Inactive. |
935 |
DI 2 Off Delay (0-999) |
936 |
DI 3 Off Delay (0-999) |
937 |
Net Mod Good Msg |
938 |
Number of good messages on the network module. |
939 |
10d |
940 |
Net Mod Bad Msg |
941 |
Number of bad messages on the Network Card Port. |
942 |
Svc Port Good Msg |
943 |
Number of good messages on the Service Port. |
944 |
Svc Port Bad Msg |
945 |
Number of bad messages on the Service Port. |
946 |
Port 1 Good Msg |
947 |
Number of good messages on Port 1. |
948 |
Port 1 Bad Msg |
949 |
Number of bad messages on Port 1. |
950 |
Port 2 Good Msg |
951 |
Number of good messages on Port 2. |
952 |
Port 2 Bad Msg |
953 |
Number of bad messages on Port 2. |
954 |
Port 3 Good Msg |
955 |
Number of good messages on Port 3. |
956 |
Port 3 Bad Msg |
957 |
Number of bad messages on Port 3. |
958 |
Port 4 Good Msg |
959 |
Number of good messages on Port 4. |
960 |
Port 4 Bad Msg |
961 |
Number of bad messages on Port 4. |
962 |
Math Units |
963 |
Six character measurement unit for the sc200 Calculated Value. |
964 |
Math Parameters |
965 |
Six character measurement parameter for the sc200 Calculated Value. |
966 |
Reset Modbus Stats |
967 |
Clears all Modbus stats to zero. |
968 |
Test Relay A |
969 |
Method to test Relay A. |
970 |
Test Relay B |
971 |
Method to test Relay B. |
972 |
Test Relay C |
973 |
Method to test Relay C. |
974 |
Test Relay D |
975 |
Method to test Relay D. |
976 |
Clear Event Logs |
977 |
This method is used to clear an event log for sensor1, sensor2, the network module or the sc200. |
978 |
Clear Data Logs |
979 |
This method is used to clear a data log for sensor1, sensor2, the network module or the sc200. |
980 |
Resets controller configuration settings to default values. |
981 |
This method will reset the over feed timer for relay A. |
982 |
This method will reset the over feed timer for relay B |
983 |
This method will reset the over feed timer for relay C. |
984 |
This method will reset the over feed timer for relay D. |
985 |
Output 1 Setup |
986 |
This method is used to setup or configure Output 1. |
987 |
Output 2 Setup |
988 |
This method is used to setup or configure output 2. |
989 |
Relay A Setup |
990 |
This method is used to setup or configure relay A. |
991 |
Relay B Setup |
992 |
This method is used to setup or configure relay B. |
993 |
Relay C Setup |
994 |
This method is used to setup or configure relay C. |
995 |
Relay D Setup |
996 |
This method is used to setup or configure relay D. |
997 |
Return Relay to Automatic Control |
998 |
Sensor 1 Status |
999 |
Sensor 1 Installation Status. |
1000 |
Installed |
1001 |
Sensor 2 Status |
1002 |
Sensor 2 Installation Status |
1003 |
Loop Current 1 |
1004 |
Loop 1 Gauge |
1005 |
Loop Current 2 |
1006 |
Loop 2 Gauge |
1007 |
Loop Currents |
1008 |
sc200 Identification |
1009 |
Loop 1 |
1010 |
Loop 2 |
1011 |
Loop Output Maintenance |
1012 |
Tests and Resets |
1013 |
sc200 Warnings / Errors |
1014 |
Internal Modbus Message Stats |
1015 |
Output 1 Maintenance |
1016 |
Output 2 Maintenance |
1017 |
Overfeed Timer A Reset |
1018 |
Overfeed Timer B Reset |
1019 |
Overfeed Timer C Reset |
1020 |
Overfeed Timer D Reset |
1021 |
12V Supply |
1022 |
Supply Currents |
1023 |
sc200 Internal Temperatures |
1024 |
Relay Test |
1025 |
Log Clears |
1026 |
Service Port Status |
1027 |
Ports Status |
1028 |
Sensor Network Status |
1029 |
sc200 Relay Status |
1030 |
Discrete Inputs |
1031 |
User Setup Menu |
1032 |
Output Information |
1033 |
An Output must be mapped to the HARTFieldDevice (sensor)to be displayed. |
1034 |
See Output Info Help. |
1035 |
Output Setup |
1036 |
Relay Information |
1037 |
A Relay must be mapped to the HART Field Device (sensor)to be displayed. |
1038 |
See Relay Info Help. |
1039 |
Relays Setup |
1040 |
Discrete Input Setup |
1041 |
General Setup |
1042 |
sc200 Output 1 |
1043 |
sc200 Output 2 |
1044 |
Error Mode |
1045 |
% range |
1046 |
Loop Current A |
1047 |
Alarm Type Loop A |
1048 |
Channel A Flags |
1049 |
Loop Current B |
1050 |
Alarm Type Loop B |
1051 |
Channel B Flags |
1052 |
Loop Current C |
1053 |
Loop 1 Current |
1054 |
.3f |
1055 |
Loop 2 Current |
1056 |
Loop A Current |
1057 |
Alarm A Select |
1058 |
Loop A Flags |
1059 |
Loop B Current |
1060 |
Alarm B Select |
1061 |
Loop B Flags |
1062 |
Loop C Current |
1063 |
Alarm C Select |
1064 |
Loop C Flags |
1065 |
LRV Loop A |
1066 |
Lower Range Value Loop A. |
1067 |
LRV Loop B |
1068 |
Lower Range Value Loop B. |
1069 |
LRV Loop C |
1070 |
Lower Range Value Loop C. |
1071 |
URV Loop A |
1072 |
Upper Range Value Loop A. |
1073 |
URV Loop B |
1074 |
Upper Range Value Loop B. |
1075 |
URV Loop C |
1076 |
Upper Range Value Loop C. |
1077 |
Transfer Val Loop A |
1078 |
Sets the transfer value. Range 3.0 to 23.0 mA (default 4.000). |
1079 |
Transfer Val Loop B |
1080 |
Transfer Val Loop C |
1081 |
Test Value Loop A. |
1082 |
Test Value Loop B. |
1083 |
Test Value Loop C. |
1084 |
LSL Loop A |
1085 |
Lower Sensor Limit Loop A. |
1086 |
LSL Loop B |
1087 |
Lower Sensor Limit Loop B. |
1088 |
LSL Loop C |
1089 |
Lower Sensor Limit Loop C. |
1090 |
USL Loop A |
1091 |
Upper Sensor Limit Loop A. |
1092 |
USL Loop B |
1093 |
Upper Sensor Limit Loop B. |
1094 |
USL Loop C |
1095 |
Upper Sensor Limit Loop C. |
1096 |
Transfer to defined Value |
1097 |
Meas. Select Loop A |
1098 |
Meas. Select Loop B |
1099 |
Meas. Select Loop C |
1100 |
Filter Loop A |
1101 |
Loop Filter Time Constant. |
1102 |
Filter Loop B |
1103 |
Filter Loop C |
1104 |
4mA Cal Count A |
1105 |
Output Loop 4mA calibration value in D/A counts. |
1106 |
4mA Cal Count B |
1107 |
4mA Cal Count C |
1108 |
20mA Cal Count A |
1109 |
Output Loop 20mA calibration value in D/A counts. |
1110 |
20mA Cal Count B |
1111 |
20mA Cal Count C |
1112 |
Test Enable Loop A |
1113 |
Test Enable Loop B |
1114 |
Test Enable Loop C |
1115 |
User Hold Loop A |
1116 |
Selection List of user Hold Modes. |
1117 |
User Hold Loop B |
1118 |
User Hold Loop C |
1119 |
Units Loop A |
1120 |
Engineering Units Loop A. |
1121 |
Units Loop B |
1122 |
Engineering Units Loop B. |
1123 |
Units Loop C |
1124 |
Engineering Units Loop C. |
1125 |
HART Loop A Mode |
1126 |
HART Loop Modes. Fixed Current = 4 mA. Active Current = 4-20 mA. |
1127 |
Fixed Current |
1128 |
Active Current |
1129 |
HART Loop B Mode |
1130 |
HART Loop A Address |
1131 |
HART Loop Address (0-63) 0->Single Loop. |
1132 |
2d |
1133 |
HART Loop B Address |
1134 |
Mapping Relay A |
1135 |
Status of Relay A mapping to HART sensor. |
1136 |
Mapping Relay B |
1137 |
Status of Relay B mapping to HART sensor. |
1138 |
Mapping Relay C |
1139 |
Status of Relay C mapping to HART sensor. |
1140 |
Mapping Relay D |
1141 |
Status of Relay D mapping to HART sensor. |
1142 |
Mapping Output 1 |
1143 |
Status of sc200 Output 1 mapping to HART sensor. |
1144 |
Mapping Output 2 |
1145 |
Status of sc200 Output 2 mapping to HART sensor. |
1146 |
Mapping Output A |
1147 |
Status of HART Output A mapping to HART sensor. |
1148 |
Mapping Output B |
1149 |
Status of HART Output B mapping to HART sensor. |
1150 |
Mapping Output C |
1151 |
Status of HART Output C mapping to HART sensor. |
1152 |
HART Channel A |
1153 |
Status of HART Channel A mapping to HART sensor. |
1154 |
HART Channel B |
1155 |
Status of HART Channel B mapping to HART sensor. |
1156 |
Status sc200 |
1157 |
Status of Device Mapping sc200. |
1158 |
Location or Name of HART Module. |
1159 |
HART Module serial number. |
1160 |
Date |
1161 |
Sets the controller date. |
1162 |
Time |
1163 |
Sets the controller time. |
1164 |
Fix analog output A |
1165 |
Fix analog output B |
1166 |
Fix analog output C |
1167 |
Fix analog output 1 |
1168 |
Fix analog output 2 |
1169 |
Trim analog output A |
1170 |
Trim analog output B |
1171 |
Trim analog output C |
1172 |
Trim analog output 1 |
1173 |
Trim analog output 2 |
1174 |
Loop A Gauge |
1175 |
Loop B Gauge |
1176 |
Loop C Gauge |
1177 |
Start |
1178 |
Diagnostics / Maintenance |
1179 |
HART Network Module |
1180 |
HART Module Identification |
1181 |
Loop A |
1182 |
Loop B |
1183 |
Loop C |
1184 |
Loop Maintenance |
1185 |
Device Mapping |
1186 |
Status of Relays and Outputs Mapped to the HART sensor. |
1187 |
Loop A Maintenance |
1188 |
Loop B Maintenance |
1189 |
Loop C Maintenance |
1190 |
HART Network Module Settings |
1191 |
Controller Date and Time Settings |
1192 |
Output A Setup |
1193 |
Output B Setup |
1194 |
Output C Setup |
1195 |
Hold Modes |
1196 |
Common Tables |
1197 |
Interoperable * |
1198 |
Universal |
1199 |
Common Practice |
1200 |
Pressure Universal |
1201 |
Pressure Common |
1202 |
Menu |
1203 |
Rosemount Magflow |
1204 |
Rosemount Pressure |
1205 |
Moore Products |
1206 |
Siemens Pressure |
1207 |
P2 Common |
1208 |
Wireless |
1209 |
Munge |
1210 |
Analytical Oxygen/Combustion/Methane/CO |
1211 |
Flow Totalizer - Rate Indicator |
1212 |
Flow Variable Area |
1213 |
Flow Coriolis Mass |
1214 |
Flow Ultrasonic - Gas |
1215 |
Flow Ultrasonic - Liquid |
1216 |
Level Ultrasonic |
1217 |
Level Radar - Microwave |
1218 |
Pressure Absolute |
1219 |
Level Capacitance |
1220 |
Pressure Differential |
1221 |
Level Hydrostatic |
1222 |
Level |
1223 |
Pressure Absolute/Relative |
1224 |
Level Microwave |
1225 |
Level Radar |
1226 |
Level Density - Nuclear |
1227 |
Flow Electromagnetic |
1228 |
Flow Vortex |
1229 |
Flow Magmeter - Rack Version |
1230 |
Flow High Performance Magmeter |
1231 |
Flow Mass |
1232 |
Flow Ultrasonic |
1233 |
Flow Magnetic |
1234 |
Flow Magnetic - Custody Transfer |
1235 |
Flow 2-wire Magnetic |
1236 |
Flow Coriolis Mass - Custody Transfer |
1237 |
Flow 2-wire Vortex |
1238 |
Flow Thermal |
1239 |
Temperature Head Mounted |
1240 |
Temperature Compact |
1241 |
Temperature DIN Rail Mounted |
1242 |
Analytical pH |
1243 |
Analytical Conductivity - Conductive |
1244 |
Analytical Conductivity - Inductive |
1245 |
Temperature Sensor |
1246 |
Level Servo |
1247 |
Temperature DIN Rail |
1248 |
Analytical ORP |
1249 |
Analytical pION |
1250 |
Analytical IConc |
1251 |
Analytical Electrode Conductivity |
1252 |
Analytical Toroidal Conductivity |
1253 |
Valve Positioner |
1254 |
Valve Controller |
1255 |
Pressure |
1256 |
Pressure Multivariable |
1257 |
Analytical pH/ORP |
1258 |
Flow Coriolis |
1259 |
Analytical Conductivity |
1260 |
Valve Positioner/Pneumatic |
1261 |
Valve Actuator - Electrical |
1262 |
Temperature Dual Input |
1263 |
Valve Actuator |
1264 |
Analytical Corrosion |
1265 |
Analytical Density - Nuclear |
1266 |
Level Continuous Gamma |
1267 |
Level Laser Ranging |
1268 |
Pressure Safety |
1269 |
Flow Vortex/Swirl |
1270 |
Flow |
1271 |
Analytical 4 Electrode Conductivity |
1272 |
Analytical 2 Electrode Conductivity |
1273 |
Analytical Troidal Conductivity |
1274 |
Analytical pH/ORP/pIon/Ion Conc |
1275 |
Analytical Oxygen |
1276 |
Pressure P, dP + Multivariable |
1277 |
Temperature 2-wire |
1278 |
Pressure w/ PID |
1279 |
Pressure Saturated Steam |
1280 |
Analytical Density - Gamma Ray |
1281 |
Level Gamma Ray |
1282 |
Analytical Weight - Gamma Ray |
1283 |
Level w/ Density - Gamma Ray |
1284 |
Analytical Motorized Density |
1285 |
Flow Multivariable Mass |
1286 |
Temperature Multivariable |
1287 |
Specialty HART-to-Analog Signal Conv |
1288 |
Flow dP |
1289 |
Pressure Low Power |
1290 |
Pressure Certified SIL2 |
1291 |
Interoperable |
1292 |
Analytical Density |
1293 |
Valve Positioner/Electropneumatic |
1294 |
Flow Magnetic Inductive |
1295 |
Analytical |
1296 |
Analytical Opacity Monitor |
1297 |
Analytical Oxygen/Combustion |
1298 |
Analytical 2-wire Conductivity |
1299 |
Analytical 2-wire Conductivity w/ pure H20 |
1300 |
Analytical 2-wire Conductivity w/ % conc |
1301 |
Analytical 2-wire Oxygen/Chlorine/Ozone |
1302 |
Analytical 2-wire pH/ORP |
1303 |
Analytical 2-wire Contacting/Toroidal |
1304 |
Analytical Oxygen - High Temperature |
1305 |
Analytical Conductivity w/ % conc |
1306 |
Analytical pH/ORP/ISE |
1307 |
Analytical Amperometric Analyzer |
1308 |
Analytical Dual Input Analyzer |
1309 |
Pressure Pressure/Level |
1310 |
Analytical Consistency |
1311 |
Analytical Microwave-Pulp Consistency |
1312 |
Analytical Microwave Consistency |
1313 |
Valve Digital Positioner |
1314 |
Valve Smart Valve Positioner |
1315 |
Temperature Differential |
1316 |
Analytical Dissolved Oxygen |
1317 |
Analytical pH Controller |
1318 |
Analytical Conductivity/Resistivity Controller |
1319 |
Analytical Conductivity/Resistivity |
1320 |
Level Displacement |
1321 |
Temperature w/ PID |
1322 |
Valve Universal Positioner |
1323 |
Level Radar - Reflex |
1324 |
Pressure Gauge |
1325 |
Pressure Sealed Gauge |
1326 |
Valve Digital Positioner w/ PID |
1327 |
Valve Intelligent Positioner |
1328 |
Analytical Gas Detector |
1329 |
Analytical Infrared Gas Detector |
1330 |
Analytical Electrochemical Gas Detector |
1331 |
Analytical Measuring Instruments |
1332 |
Level Magnostrictive |
1333 |
Valve On/Off Valve Controller |
1334 |
Level Radar - Pulse |
1335 |
Level Continuous Capactive |
1336 |
Valve Damper Actuator |
1337 |
Valve Electric Damper Actuator |
1338 |
Flow Electronic |
1339 |
Flow Vortex - Multiparameter Mass |
1340 |
Analytical UV Flame Detector |
1341 |
Analytical UVIR Flame Detector |
1342 |
Analytical IR Flame Detector |
1343 |
Analytical Fire Detector |
1344 |
Analytical Gas Detector Display Interface |
1345 |
Analytical Toxic Gas Detector |
1346 |
Analytical Flame Detector |
1347 |
Level Nuclear |
1348 |
Analytical Microwave |
1349 |
Analytical Density - Radiometric |
1350 |
Level Radiometric |
1351 |
Analytical Gas/Steam |
1352 |
Level Nucleonic |
1353 |
Analytical Blade Consistency |
1354 |
Analytical Rotary Consistency |
1355 |
Pressure Absolute/Differential |
1356 |
Positioner |
1357 |
Analytical Combustible Gas Detector |
1358 |
Analytical Point Infrared Gas Detector |
1359 |
Analytical Multi-Detector Monitor System |
1360 |
Valve Positioner/Electro-hydraulic |
1361 |
Valve Monitor |
1362 |
Enable on token-passing data link layer only |
1363 |
Enable on TDMA data link layer only |
1364 |
Enable on both TDMA and token-passing data link layer |
1365 |
WirelessHART Device |
1366 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
1367 |
Primary |
1368 |
Primary Analog Channel |
1369 |
Secondary |
1370 |
Secondary Analog Channel |
1371 |
Tertiary |
1372 |
Tertiary Analog Channel |
1373 |
Quaternary |
1374 |
Quaternary Analog Channel |
1375 |
Quinary |
1376 |
Quinary Analog Channel |
1377 |
Critical Power Failure |
1378 |
Lock all |
1379 |
Trim not supported |
1380 |
Configuration cannot be changed |
1381 |
Locked by gateway |
1382 |
Analog Input Channel |
1383 |
Analog Output Channel |
1384 |
Secondary Analog Channel Saturated |
1385 |
Tertiary Analog Channel Saturated |
1386 |
Quaternary Analog Channel Saturated |
1387 |
Quinary Analog Channel Saturated |
1388 |
Secondary Analog Channel Fixed |
1389 |
Tertiary Analog Channel Fixed |
1390 |
Quaternary Analog Channel Fixed |
1391 |
Quinary Analog Channel Fixed |
1392 |
Simulation active |
1393 |
The device is in simulation mode and the level output is not representative of the process. |
1394 |
Non-Volatile memory failure |
1395 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
1396 |
Volatile memory error |
1397 |
The RAM memory check is invalid or maybe corrupt |
1398 |
Watchdog reset executed |
1399 |
A watchdog reset has been performed |
1400 |
Voltage conditions out of range |
1401 |
A voltage condition is outside its allowable range |
1402 |
Environmental conditions out of range |
1403 |
An internal or environmental condition is beyond acceptable limits. |
1404 |
Electronic failure |
1405 |
A hardware problem not related to the sensor has been detected. |
1406 |
Subdevice list changed |
1407 |
Duplicate master detected |
1408 |
Capacity Denied |
1409 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
1410 |
Bandwidth allocation pending |
1411 |
Block transfer pending |
1412 |
Continuous |
1413 |
The Burst Message is published continuously at (worst case) the Minimum Update Period. |
1414 |
Window |
1415 |
The Burst Message is triggered when the source value deviates more than the specified trigger value |
1416 |
Rising |
1417 |
The Burst Message is triggered when source value Rises Above the specified trigger value. |
1418 |
Falling |
1419 |
The Burst Message is triggered when the source value Falls Below the specified trigger value. |
1420 |
On-change |
1421 |
The Burst Message is triggered when any value in the message changes. |
1422 |
Battery life |
1423 |
Percent range |
1424 |
Loop current |
1425 |
Primary variable |
1426 |
Secondary variable |
1427 |
Tertiary variable |
1428 |
Quaternary variable |
1429 |
Enable event notification on token-passing data link layer |
1430 |
Enable event notification on TDMA data link layer |
1431 |
Enable event notification on TDMA and token-passing data link layer |
1432 |
Configuration changed event pending |
1433 |
Device status event pending |
1434 |
More status available event pending |
1435 |
Disable |
1436 |
Enable single data point trending |
1437 |
Enable filtered trending |
1438 |
The sample is filtered using a time constant equal to one-third the trend sample period |
1439 |
Enable average trending |
1440 |
The value obtained by dividing the sum of all samples in the period by the total number of samples |
1441 |
Read receive time |
1442 |
Write date and time |
1443 |
Non-Volatile Clock |
1444 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
1445 |
Clock Uninitialized |
1446 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
1447 |
Line Power |
1448 |
Device is powered via a hardwired connection to a plant power source. |
1449 |
Battery Power |
1450 |
Device operates solely of its (internal) battery. |
1451 |
Recharg.B./Power Sc. |
1452 |
Rechargeable battery power or power scavenging. The device has a short-term supply of energy (must be at least one hour) that is continuously being replenished. The device's power is being replenished by harvesting and converting energy from the environment surrounding the device (e.g. solar, vibration, heat). |
1453 |
Idle |
1454 |
Active search |
1455 |
Looking for neighbors. |
1456 |
Negotiating |
1457 |
Quarantined |
1458 |
Operational |
1459 |
Suspended |
1460 |
Deep sleep |
1461 |
Ultra-low power |
1462 |
Wireless Signal Found |
1463 |
Network packets have been recognized |
1464 |
Wireless Signal Identified |
1465 |
Wireless Time Synchronized |
1466 |
WirelessHart Signal Identified |
1467 |
Network Admission Requested |
1468 |
Set on transmission of first join request |
1469 |
Join Retrying |
1470 |
Set after the first join request retry (i.e. when number of join requests > 2). Cleared when device is authenticated or when Active Search started. |
1471 |
Join Failed |
1472 |
Set on transition from Active Search mode to Deep Sleep mode. Cleared on transition from Deep Sleep to Active Search. |
1473 |
Network Security Clearance Granted |
1474 |
Network Manager Session Established |
1475 |
Network Joined |
1476 |
Network Joined. Normal superframe and links obtained. |
1477 |
Network Bandwidth Requested |
1478 |
Negotiating Network Properties. Gateway session obtained. |
1479 |
Join Complete |
1480 |
Normal operating mode. |
1481 |
No restrictions |
1482 |
SI Only |
1483 |
Restricted to SI Unit codes only |
1484 |
Open - accept all devices |
1485 |
Use Whitelist for access |
1486 |
Use Blacklist |
1487 |
Use Whitelist and Blacklist |
1488 |
Lockdown - disable join links |
1489 |
Process automation device |
1490 |
Discrete device |
1491 |
Hybrid:Process automation+discrete |
1492 |
I/O System |
1493 |
WirelessHART Process automation device |
1494 |
WirelessHART Discrete device |
1495 |
WirelessHART Process automation+discrete |
1496 |
WirelessHART Gateway |
1497 |
WirelessHART Access point |
1498 |
WirelessHART Process adapter |
1499 |
WirelessHART Discrete adapter |
1500 |
WirelessHART enabled handheld/portable maintenance tool |
1501 |
Don't attempt to join |
1502 |
Join now |
1503 |
Attempt to join immediately on powerup or reset |
1504 |
US |
1505 |
United States of America |
1506 |
JP |
1507 |
Japan |
1508 |
DE |
1509 |
Germany |
1510 |
FR |
1511 |
France |
1512 |
ES |
1513 |
Spain |
1514 |
RU |
1515 |
Russian Federation |
1516 |
CN |
1517 |
People's Republic of China |
1518 |
Nominal |
1519 |
Device Power Status is nominal |
1520 |
Device Power Status is low |
1521 |
Critically Low |
1522 |
Device Power Status is critically low |
1523 |
Recharging - Low |
1524 |
Recharging - High |
1525 |
Secondary Master |
1526 |
Primary Master |
1527 |
PV Analog Channel Saturated |
1528 |
PV Analog Channel Fixed |
1529 |
Device Profile |
1530 |
|
1531 |
Device Diagnostic Status 0 |
1532 |
Device Diagnostic Status 1 |
1533 |
I/O and Subdevice Status |
1534 |
WirelessHART Status |
1535 |
Time Set Option |
1536 |
Real Time Clock Flags |
1537 |
Country |
1538 |
Country of intended device installation |
1539 |
SI Unit Control |
1540 |
Indicates if device should only display SI unit codes |
1541 |
Burst Trigger Units |
1542 |
Burst Trigger Class |
1543 |
Wired HART Enabled |
1544 |
Enabled on Wired HART device connection only |
1545 |
Wireless HART Enabled |
1546 |
Enabled on WirelessHART device connection only |
1547 |
Both Wired and WirelessHart Enabled |
1548 |
Enabled on both Wired and WirelessHART connections |
1549 |
Burst Msg Trigger Mode |
1550 |
Event Status |
1551 |
Event Notification Control |
1552 |
Operate mode Mask |
1553 |
Not Defined |
1554 |
Power Source |
1555 |
Power source of the device |
1556 |
Wireless Mode |
1557 |
Join Status |
1558 |
The current location in the joining sequence of operations. |
1559 |
Network Access Mode |
1560 |
Join Mode |
1561 |
Power Status |
1562 |
Power status of the device |
1563 |
Master Mode |
1564 |
This sets the I/O System's Data Link Layer operation on all channels as either primary or secondary master mode. |
1565 |
Trend Units |
1566 |
Trend Device Variable Unit Code |
1567 |
Trend Classification |
1568 |
Trend Device Variable Classification |
1569 |
Trend Control |
1570 |
uint16_var_blk_char |
1571 |
uint8_var_blk_char |
1572 |
Device Status Mask |
1573 |
Ext dev status Mask |
1574 |
Device Diagnostic Status 0 Mask |
1575 |
Device Diagnostic Status 1 Mask |
1576 |
Device Diagnostic Status 2 Mask |
1577 |
Device Diagnostic Status 3 Mask |
1578 |
AO saturated Mask |
1579 |
AO fixed Mask |
1580 |
Latched Device Status |
1581 |
Latched Ext dev status |
1582 |
Latched Operate Mode |
1583 |
Latched Device Diagnostic Status 0 |
1584 |
Latched Device Diagnostic Status 1 |
1585 |
Latched Device Diagnostic Status 2 |
1586 |
Latched Device Diagnostic Status 3 |
1587 |
Latched AO saturated |
1588 |
Latched AO fixed |
1589 |
Wireless Module Device Type |
1590 |
Device type of the Wireless Radio |
1591 |
Wireless Module Manufacturer ID |
1592 |
Manufacturer of the Wireless Radio contained in this device |
1593 |
Subdevice Device Type |
1594 |
Device type of the subdevice attached to this system. |
1595 |
Subdevice Manufacturer Id |
1596 |
Manufacturer of the subdevice attached to this system. |
1597 |
8u |
1598 |
Dynamic Variables Returned for Device Variables |
1599 |
Command Response Truncated |
1600 |
Configuration Change Counter Mismatch |
1601 |
Status bytes mismatch |
1602 |
8.3f |
1603 |
Output Status |
1604 |
Output Status Byte |
1605 |
Uninitialized |
1606 |
Normal - one sensor |
1607 |
Normal - two sensors |
1608 |
Normal - three sensors |
1609 |
Shorted |
1610 |
Shorted- shorted field wiring. |
1611 |
Limited high |
1612 |
Limited high- block can not respond to upward movement of value. |
1613 |
Open |
1614 |
Open- open field wiring. |
1615 |
Limited low |
1616 |
Limited low- block can not respond to upward movement of target. |
1617 |
Initialization done |
1618 |
Initialization done- block initialization is complete. |
1619 |
Not selected |
1620 |
Not selected- target value provided by block was not selected. |
1621 |
No path |
1622 |
No path- there is no path to the process. |
1623 |
Fail |
1624 |
Fail- hardware failure. |
1625 |
Bad |
1626 |
Bad- block is out of service or has bad input. |
1627 |
Not from process |
1628 |
Not from process- value is not directly affected by any process information. |
1629 |
Local override |
1630 |
Local override- block has LO mode. |
1631 |
Not Cascade Mode |
1632 |
Not RCas Mode |
1633 |
Not ROut Mode |
1634 |
No communication |
1635 |
No communication- (NO_COM). |
1636 |
uint32_var_blk_char |
1637 |
int8_var_blk_char |
1638 |
new itest redef1 label |