0 |
GTD2000 |
1 |
GASTRON |
2 |
Gas Value |
3 |
.3f |
4 |
gas unit |
5 |
Gas LS |
6 |
Gas PDQ |
7 |
Gas damping Value |
8 |
|
9 |
8.3f |
10 |
gas sensor serial number |
11 |
|
12 |
7d |
13 |
Gas Lower trim |
14 |
Gas Upper trim |
15 |
Gas Trim support |
16 |
Gas Min lower trim |
17 |
Gas Max lower trim |
18 |
Gas Min upper trim |
19 |
Pres Max upper trim |
20 |
Gas Min trim diff |
21 |
gas |
22 |
Simulate |
23 |
Update Period |
24 |
Alrm 1 level Set |
25 |
Edits the alarm 1 setpoint |
26 |
Alrm 2 level Set |
27 |
Edits the alarm 2 setpoint |
28 |
Gas Fmly stat |
29 |
Gas Class |
30 |
Gas Dev fmly |
31 |
gas upper sensor limit |
32 |
gas_lower_sensor_limit |
33 |
gas_minimum_span |
34 |
Gas Update Period |
35 |
F/W REV |
36 |
Alarm1 |
37 |
5.3f |
38 |
Alarm2 |
39 |
cal mode |
40 |
NORMAL |
41 |
ZERO MODE |
42 |
SPAN MODE |
43 |
UNKNOWN MODE |
44 |
cal status |
45 |
CAL PROCESSING STATUS |
46 |
CAL OK STATUS |
47 |
CAL FAIL STATUS |
48 |
UNKNOWN STATUS |
49 |
cal do mode |
50 |
DO ZERO |
51 |
DO SPAN |
52 |
gas name |
53 |
cal test gas name |
54 |
unit str |
55 |
calibration gas name |
56 |
calibraion leave |
57 |
calibraion gas |
58 |
GTD2000 Setup |
59 |
GTD2000 Setup Menu |
60 |
status |
61 |
PV Analog Channel Saturated |
62 |
PV Analog Channel Fixed |
63 |
Wireless |
64 |
WirelessHART Device |
65 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
66 |
Primary |
67 |
Primary Analog Channel |
68 |
Secondary |
69 |
Secondary Analog Channel |
70 |
Tertiary |
71 |
Tertiary Analog Channel |
72 |
Quaternary |
73 |
Quaternary Analog Channel |
74 |
Quinary |
75 |
Quinary Analog Channel |
76 |
Critical Power Failure |
77 |
Lock all |
78 |
Trim not supported |
79 |
Configuration cannot be changed |
80 |
Locked by gateway |
81 |
Analog Input Channel |
82 |
Analog Output Channel |
83 |
Secondary Analog Channel Saturated |
84 |
Tertiary Analog Channel Saturated |
85 |
Quaternary Analog Channel Saturated |
86 |
Quinary Analog Channel Saturated |
87 |
Secondary Analog Channel Fixed |
88 |
Tertiary Analog Channel Fixed |
89 |
Quaternary Analog Channel Fixed |
90 |
Quinary Analog Channel Fixed |
91 |
Simulation active |
92 |
The device is in simulation mode and the level output is not representative of the process. |
93 |
Non-Volatile memory failure |
94 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
95 |
Volatile memory error |
96 |
The RAM memory check is invalid or maybe corrupt |
97 |
Watchdog reset executed |
98 |
A watchdog reset has been performed |
99 |
Voltage conditions out of range |
100 |
A voltage condition is outside its allowable range |
101 |
Environmental conditions out of range |
102 |
An internal or environmental condition is beyond acceptable limits. |
103 |
Electronic failure |
104 |
A hardware problem not related to the sensor has been detected. |
105 |
Subdevice list changed |
106 |
Duplicate master detected |
107 |
Capacity Denied |
108 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
109 |
Bandwidth allocation pending |
110 |
Block transfer pending |
111 |
Battery life |
112 |
Percent range |
113 |
Loop current |
114 |
Primary variable |
115 |
Secondary variable |
116 |
Tertiary variable |
117 |
Quaternary variable |
118 |
Read receive time |
119 |
Write date and time |
120 |
Non-Volatile Clock |
121 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
122 |
Clock Uninitialized |
123 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
124 |
None |
125 |
No restrictions |
126 |
SI Only |
127 |
Restricted to SI Unit codes only |
128 |
Process automation device |
129 |
Discrete device |
130 |
Hybrid:Process automation+discrete |
131 |
I/O System |
132 |
WirelessHART Process automation device |
133 |
WirelessHART Discrete device |
134 |
WirelessHART Process automation+discrete |
135 |
WirelessHART Gateway |
136 |
WirelessHART Access point |
137 |
WirelessHART Process adapter |
138 |
WirelessHART Discrete adapter |
139 |
WirelessHART enabled handheld/portable maintenance tool |
140 |
Device Profile |
141 |
US |
142 |
United States of America |
143 |
JP |
144 |
Japan |
145 |
DE |
146 |
Germany |
147 |
FR |
148 |
France |
149 |
ES |
150 |
Spain |
151 |
RU |
152 |
Russian Federation |
153 |
CN |
154 |
People's Republic of China |
155 |
Secondary Master |
156 |
Primary Master |
157 |
Device Diagnostic Status 0 |
158 |
Device Diagnostic Status 1 |
159 |
I/O and Subdevice Status |
160 |
WirelessHART Status |
161 |
Time Set Option |
162 |
Real Time Clock Flags |
163 |
Country |
164 |
Country of intended device installation |
165 |
SI Unit Control |
166 |
Indicates if device should only display SI unit codes |
167 |
Time Stamp |
168 |
Relative time value on network |
169 |
8u |
170 |
Dynamic Variables Returned for Device Variables |
171 |
Command Response Truncated |
172 |
Configuration Change Counter Mismatch |
173 |
Status bytes mismatch |
174 |
Alarm 1 level |
175 |
Alarm 2 level |
176 |
Warning This will affect sensor calibration |
177 |
Select Calibration |
178 |
Zero;Span |
179 |
Entering Zero mode |
180 |
Entering Span mode |
181 |
Time:%[d]{to_time}
Zero gas(do zero calibration after 30 second)
Test Concentration= %{2}%{1} |
182 |
Device is doing Zero Calibration, please wait |
183 |
zero calibration processing |
184 |
zero calibration ok |
185 |
zero calibration fail |
186 |
Span Calibration must be done at local device |