0 |
IP address |
1 |
Enter the IP address of the measuring device |
2 |
192.168.1.212 |
3 |
Default gateway |
4 |
Enter IP address for the default gateway of the measuring device |
5 |
0.0.0.0 |
6 |
Subnet mask |
7 |
Enter subnet mask of the measuring device |
8 |
255.255.255.0 |
9 |
DHCP client |
10 |
Switch the DHCP client functionality on and of |
11 |
Off |
12 |
On |
13 |
DomainName 1 |
14 |
0 |
15 |
DomainNameLength 1 |
16 |
PrimaryNameServer |
17 |
MAC address |
18 |
Shows the MAC address of the measuring device |
19 |
|
20 |
SecondaryNameServer |
21 |
WebserverAccess |
22 |
Web server language |
23 |
Set web server language |
24 |
English |
25 |
German |
26 |
French |
27 |
Spanish |
28 |
Italian |
29 |
Dutch |
30 |
Portuguese |
31 |
Polish |
32 |
Russian |
33 |
Swedish |
34 |
Turkish |
35 |
Chinese |
36 |
Japanese |
37 |
Korean |
38 |
Arabic |
39 |
Indonesian |
40 |
Thai |
41 |
Vietnamese |
42 |
Czech |
43 |
Login page |
44 |
Select format of login page |
45 |
Without header |
46 |
With header |
47 |
Web server functionality |
48 |
Switch web server on and off, switch off HTML |
49 |
HTML Off |
50 |
CurrentInput_ActInstance |
51 |
Failure mode |
52 |
Define input behavior in alarm condition |
53 |
(a) Alarm |
54 |
(b) Last valid value |
55 |
(c) Defined value |
56 |
Failure value |
57 |
Enter value to be used by the device if input value from external device is missing |
58 |
.2f |
59 |
|
60 |
% |
61 |
%/mA |
62 |
° |
63 |
°C |
64 |
°F |
65 |
°R |
66 |
µm |
67 |
µs |
68 |
1/K |
69 |
1/K² |
70 |
a |
71 |
A |
72 |
bar a |
73 |
Btu |
74 |
Btu/day |
75 |
Btu/h |
76 |
Btu/min |
77 |
Btu/s |
78 |
Btu/Sft³ |
79 |
Btu/Sm³ |
80 |
cm² |
81 |
d |
82 |
dm² |
83 |
ft |
84 |
ft/s |
85 |
ft² |
86 |
ft³ |
87 |
ft³ FAD |
88 |
ft³ FAD/d |
89 |
ft³ FAD/h |
90 |
ft³ FAD/min |
91 |
ft³ FAD/s |
92 |
ft³/d |
93 |
ft³/h |
94 |
ft³/min |
95 |
ft³/s |
96 |
g |
97 |
g/cm³ |
98 |
g/d |
99 |
g/h |
100 |
g/min |
101 |
g/s |
102 |
g/Scm³ |
103 |
Gcal |
104 |
Gcal/d |
105 |
Gcal/h |
106 |
Gcal/min |
107 |
Gcal/s |
108 |
GJ |
109 |
GJ/d |
110 |
GJ/h |
111 |
GJ/min |
112 |
GJ/s |
113 |
GW |
114 |
GWh |
115 |
h |
116 |
ha |
117 |
Hz |
118 |
in |
119 |
in² |
120 |
J/(kgK) |
121 |
J/kg |
122 |
K |
123 |
kcal |
124 |
kcal/d |
125 |
kcal/h |
126 |
kcal/min |
127 |
kcal/s |
128 |
kg |
129 |
kg/d |
130 |
kg/dm³ |
131 |
kg/h |
132 |
kg/l |
133 |
kg/m³ |
134 |
kg/min |
135 |
kg/Nl |
136 |
kg/Nm³ |
137 |
kg/s |
138 |
kg/Sm³ |
139 |
kJ |
140 |
kJ/d |
141 |
kJ/h |
142 |
kJ/min |
143 |
kJ/Nm³ |
144 |
kJ/s |
145 |
kJ/Sm³ |
146 |
km² |
147 |
kPa a |
148 |
ks |
149 |
kW |
150 |
kWh |
151 |
kWh/(kgK) |
152 |
kWh/Nm³ |
153 |
kWh/Sm³ |
154 |
l |
155 |
l FAD |
156 |
l FAD/d |
157 |
l FAD/h |
158 |
l FAD/min |
159 |
l FAD/s |
160 |
l/d |
161 |
l/h |
162 |
l/min |
163 |
l/s |
164 |
lb |
165 |
lb/d |
166 |
lb/ft³ |
167 |
lb/h |
168 |
lb/min |
169 |
lb/s |
170 |
lb/Sft³ |
171 |
m |
172 |
m/s |
173 |
m² |
174 |
m2K/W |
175 |
m³ |
176 |
m³ FAD |
177 |
m³ FAD/d |
178 |
m³ FAD/h |
179 |
m³ FAD/min |
180 |
m³ FAD/s |
181 |
m³/d |
182 |
m³/h |
183 |
m³/min |
184 |
m³/s |
185 |
mA |
186 |
mbar |
187 |
MBaud |
188 |
MBtu |
189 |
MBtu/d |
190 |
MBtu/h |
191 |
MBtu/min |
192 |
MBtu/s |
193 |
MBtu/Sft³ |
194 |
MBtu/Sm³ |
195 |
Mcal |
196 |
Mcal/d |
197 |
Mcal/h |
198 |
Mcal/min |
199 |
Mcal/s |
200 |
mile² |
201 |
min |
202 |
MJ |
203 |
MJ/d |
204 |
MJ/h |
205 |
MJ/kg |
206 |
MJ/min |
207 |
MJ/s |
208 |
mm |
209 |
mm² |
210 |
MMBtu |
211 |
MMBtu/d |
212 |
MMBtu/h |
213 |
MMBtu/min |
214 |
MMBtu/s |
215 |
MMft³ |
216 |
MMSft³ |
217 |
MMSft³/h |
218 |
MMSft³/min |
219 |
MMSft³/s |
220 |
MPa a |
221 |
ms |
222 |
mV |
223 |
mW |
224 |
MW |
225 |
mW/K |
226 |
MWh |
227 |
Nhl |
228 |
Nhl/d |
229 |
Nhl/h |
230 |
Nhl/min |
231 |
Nhl/s |
232 |
Nl |
233 |
Nl/d |
234 |
Nl/h |
235 |
Nl/min |
236 |
Nl/s |
237 |
Nm³ |
238 |
Nm³/d |
239 |
Nm³/h |
240 |
Nm³/min |
241 |
Nm³/s |
242 |
None |
243 |
nV |
244 |
Ohm |
245 |
oz |
246 |
oz/d |
247 |
oz/h |
248 |
oz/min |
249 |
oz/s |
250 |
Pa s |
251 |
ppm |
252 |
psi a |
253 |
rad |
254 |
s |
255 |
Sbbl (us;liq.) |
256 |
Sbbl (us;oil) |
257 |
Sbbl/d (us;oil) |
258 |
Sbbl/h (us;oil) |
259 |
Sbbl/min (us;oil) |
260 |
Sbbl/s (us;oil) |
261 |
Sft³ |
262 |
Sft³/d |
263 |
Sft³/h |
264 |
Sft³/min |
265 |
Sft³/s |
266 |
Sgal (imp) |
267 |
Sgal (us) |
268 |
Sl |
269 |
Sl/d |
270 |
Sl/h |
271 |
Sl/min |
272 |
Sl/s |
273 |
Sm³ |
274 |
Sm³/d |
275 |
Sm³/h |
276 |
Sm³/min |
277 |
Sm³/s |
278 |
STon |
279 |
STon/d |
280 |
STon/h |
281 |
STon/min |
282 |
STon/s |
283 |
t |
284 |
t/d |
285 |
t/h |
286 |
t/min |
287 |
t/s |
288 |
V |
289 |
W/K |
290 |
W/m²K |
291 |
W/mK |
292 |
yd² |
293 |
Measured values 1 |
294 |
Shows the actual input value of the current input |
295 |
Measured values 2 |
296 |
Measured values 3 |
297 |
Measured current 1 |
298 |
Shows the currenly measured value of the current input |
299 |
Measured current 2 |
300 |
Measured current 3 |
301 |
Current span |
302 |
Select current range for process value output and upper/lower level for alarm signal |
303 |
4...20 mA (4... 20.5 mA) |
304 |
4...20 mA NAMUR (3.8...20.5 mA) |
305 |
4...20 mA US (3.9...20.8 mA) |
306 |
0...20 mA (0... 20.5 mA) |
307 |
0/4 mA value |
308 |
Enter 4 mA value |
309 |
.3f |
310 |
20 mA value |
311 |
Enter 20 mA value |
312 |
Input Source 1 |
313 |
Determines which process variable is transmitted via the current output. |
314 |
Pressure |
315 |
2nd temperature heat flow |
316 |
InsituMassFlow |
317 |
InsituStdVolumeFlow |
318 |
InsituFADVolumeFlow |
319 |
InsituVolumeFlow |
320 |
Input Source 2 |
321 |
Input Source 3 |
322 |
Signal mode |
323 |
Select the signal mode for the current input |
324 |
Passive |
325 |
Active |
326 |
Current input 1 simulation |
327 |
Switch the simulation of the current input on and off |
328 |
Current input 2 simulation |
329 |
Current input 3 simulation |
330 |
Value current input 1 |
331 |
Enter value for simulation of the current input |
332 |
Value current input 2 |
333 |
Value current input 3 |
334 |
Terminal number |
335 |
Shows the terminal numbers used by the current input module |
336 |
Not used |
337 |
26-27 (I/O 1) |
338 |
24-25 (I/O 2) |
339 |
22-23 (I/O 3) |
340 |
20-21 (I/O 4) |
341 |
CurrentOutput_ActInstance |
342 |
Trim |
343 |
Select adjustment mode for trim |
344 |
4 mA |
345 |
20 mA |
346 |
Calculate |
347 |
Reset |
348 |
CorrGain 1 |
349 |
CorrOffset 1 |
350 |
Defines which current the output assumes in the case of an error.
'Min.':
< 3.6mA
'Max.':
> 21.95mA
'Last valid value':
Last valid value before occurrence of the error.
'Actual value':
Output current is equal to the measured value; error is ignored.
'Defined value':
User defined value.
|
351 |
Min. |
352 |
Max. |
353 |
Last valid value |
354 |
Actual value |
355 |
Defined value |
356 |
Failure current |
357 |
Enter current output value in alarm condition |
358 |
Fixed current |
359 |
Defines the fixed output current. |
360 |
Assign current output 1 |
361 |
Temperature |
362 |
Mass flow |
363 |
Corrected volume flow |
364 |
FAD volume flow |
365 |
Volume flow |
366 |
Energy flow |
367 |
Heat flow |
368 |
Density |
369 |
Flow velocity |
370 |
2nd temperature delta heat |
371 |
Electronic temperature |
372 |
Assign current output 2 |
373 |
Assign current output 3 |
374 |
Assign current output 4 |
375 |
InputSelOffVisible 1 |
376 |
Shows the current value of the current output which is currently measured |
377 |
Measured current 4 |
378 |
Measuring mode |
379 |
Select measuring mode for output |
380 |
Forward flow |
381 |
Forward/Reverse flow |
382 |
Reverse flow compensation |
383 |
Select the signal mode for the current output |
384 |
Status |
385 |
Shows the status of the last output current (OutValue) |
386 |
u |
387 |
Output current 1 |
388 |
Shows the actual calculated value of the output current |
389 |
Output current 2 |
390 |
Output current 3 |
391 |
Output current 4 |
392 |
Current output 1 simulation |
393 |
'On'
The current simulation is active . The output current does not correspond to the measured value but to the value defined in the 'Value current output' parameter.
'Off'
The current simulation is not active. The output current corresponds to the measured value. |
394 |
Current output 2 simulation |
395 |
Current output 3 simulation |
396 |
Current output 4 simulation |
397 |
Value current output 1 |
398 |
Defines the value of the simulated output current. |
399 |
Value current output 2 |
400 |
Value current output 3 |
401 |
Value current output 4 |
402 |
Damping output 1 |
403 |
Reaction time of the output signal on fluctuation in the measured value. |
404 |
.1f |
405 |
Damping output 2 |
406 |
Damping output 3 |
407 |
Damping output 4 |
408 |
Shows the terminal numbers used by the current output module |
409 |
Trim value high |
410 |
Enter upper measured value for trim (around 20 mA) |
411 |
Trim value low |
412 |
Enter lower measured value for the trim (around 4 mA) |
413 |
Turn down |
414 |
Configuration management |
415 |
Select action for managing the device data in the HistoROM backup |
416 |
Cancel |
417 |
Execute backup |
418 |
Restore |
419 |
Compare |
420 |
Clear backup data |
421 |
Last backup |
422 |
Shows when the last data backup was saved to HistoROM backup |
423 |
|
424 |
Backup state |
425 |
Shows the current status of data saving or restoring |
426 |
None |
427 |
Backup in progress |
428 |
Restoring in progress |
429 |
Delete in progress |
430 |
Compare in progress |
431 |
Restoring failed |
432 |
Backup failed |
433 |
Calibration factor |
434 |
Shows the calibration factor matching to the selected calibration data record |
435 |
CalHiLimitDays 1 |
436 |
CalHiLimitHours 1 |
437 |
Calibration counter |
438 |
Shows the number of calibrations performed on the measuring device |
439 |
Select calibration log entry |
440 |
Enter number for the desired calibration data record |
441 |
CalLoLimitHours 1 |
442 |
AM/PM |
443 |
Select AM or PM |
444 |
AM |
445 |
PM |
446 |
Day |
447 |
Enter current day |
448 |
Hour |
449 |
Enter current hour |
450 |
Minute |
451 |
Enter current minute |
452 |
Month |
453 |
Select current month |
454 |
January |
455 |
February |
456 |
March |
457 |
April |
458 |
May |
459 |
June |
460 |
July |
461 |
August |
462 |
September |
463 |
October |
464 |
November |
465 |
December |
466 |
Timestamp |
467 |
Shows the time stamp entered with the calibration factor |
468 |
Calibration date/time |
469 |
Shows date and time of the last calibration |
470 |
Year |
471 |
Enter current year |
472 |
Plant operator |
473 |
Enter plant operator |
474 |
-------------------------------- |
475 |
Date/time format |
476 |
Select date and time format |
477 |
dd.mm.yy hh:mm |
478 |
dd.mm.yy hh:mm am/pm |
479 |
mm/dd/yy hh:mm |
480 |
mm/dd/yy hh:mm am/pm |
481 |
Sensor type |
482 |
-- |
483 |
: |
484 |
C : |
485 |
D : |
486 |
E : |
487 |
Definition is missing |
488 |
G : |
489 |
J : |
490 |
K : |
491 |
O : |
492 |
P : |
493 |
R : |
494 |
S : |
495 |
T : |
496 |
U : |
497 |
V : |
498 |
W : |
499 |
Y : |
500 |
Z : |
501 |
5 : |
502 |
Level of flow fluctuation |
503 |
Select fluctuation level of measured value |
504 |
Slight |
505 |
Moderate |
506 |
Strong |
507 |
Is restore available |
508 |
Maximum authorized temperature |
509 |
Minimum authorized temperature |
510 |
NewCalFactorState |
511 |
.5f |
512 |
Nominal diameter |
513 |
Shows the nominal diameter of the sensor |
514 |
-------------- |
515 |
Location |
516 |
Enter the location where the measuring device is mounted. Information appears in the verification report. |
517 |
Transmitter identifier |
518 |
Select transmitter identifier |
519 |
Unknown |
520 |
500 |
521 |
300 |
522 |
Progress |
523 |
Shows the progress of the process |
524 |
Reset all totalizers |
525 |
Reset all totalizers to 0 and start |
526 |
Reset + totalize |
527 |
SDatImageAvailable |
528 |
No |
529 |
Yes |
530 |
Comparison result |
531 |
Comparison of current device data with HistoROM backup |
532 |
Settings identical |
533 |
Settings not identical |
534 |
No backup available |
535 |
Backup settings corrupt |
536 |
Check not done |
537 |
Dataset incompatible |
538 |
I/O alteration code |
539 |
Enter the code in order to change the I/O configuration |
540 |
Display interval |
541 |
Set time measured values are shown on display if display alternates between values |
542 |
.0f |
543 |
Backlight |
544 |
Switch the local display backlight on and off |
545 |
Disable |
546 |
Enable |
547 |
Contrast display |
548 |
Adjust local display contrast setting to ambient conditions (e.g. lighting or reading angle) |
549 |
Display damping |
550 |
Set display reaction time to fluctuations in the measured value |
551 |
Decimal places 1 |
552 |
This selection does not affect the measurement and calculation accuracy of the device. |
553 |
x |
554 |
x.x |
555 |
x.xx |
556 |
x.xxx |
557 |
x.xxxx |
558 |
Decimal places 2 |
559 |
Decimal places 3 |
560 |
Decimal places 4 |
561 |
Header text |
562 |
Enter display header text |
563 |
------------ |
564 |
Value 1 display |
565 |
Select the measured value that is shown on the local display |
566 |
Totalizer 1 |
567 |
Totalizer 2 |
568 |
Totalizer 3 |
569 |
Current output 1 |
570 |
Current output 2 |
571 |
Current output 3 |
572 |
Current output 4 |
573 |
Value 2 display |
574 |
Value 3 display |
575 |
Value 4 display |
576 |
Backlight |
577 |
Display language |
578 |
Set display language |
579 |
Header |
580 |
Select header contents on local display |
581 |
Device tag |
582 |
Free text |
583 |
Format display |
584 |
Select how measured values are shown on the display |
585 |
1 value, max. size |
586 |
1 bargraph + 1 value |
587 |
2 values |
588 |
1 value large + 2 values |
589 |
4 values |
590 |
Separator |
591 |
Select decimal separator for displaying numerical values |
592 |
. |
593 |
, |
594 |
0% bargraph value 1 |
595 |
Enter 0% value for bar graph display |
596 |
.4f |
597 |
100% bargraph value 1 |
598 |
Enter 100% value for bar graph display |
599 |
0% bargraph value 3 |
600 |
100% bargraph value 3 |
601 |
Assign process variable |
602 |
Select process variable for low flow cut off |
603 |
Flow damping |
604 |
Enter value for damping the flow measured value |
605 |
Temperature damping |
606 |
Enter value for damping the temperature value |
607 |
Installation direction |
608 |
Select sign of flow direction |
609 |
Reverse flow |
610 |
Off value low flow cutoff |
611 |
Enter off value for low flow cut off |
612 |
On value low flow cutoff |
613 |
Enter on value for low flow cut off |
614 |
High value partial filled pipe detection |
615 |
Enter upper limit value for deactivating partialy filled pipe detection |
616 |
Response time part. filled pipe detect. |
617 |
Enter time before diagnostic message is displayed for partially filled pipe detection |
618 |
Select process variable for partially filled pipe detection |
619 |
Low value partial filled pipe detection |
620 |
Enter lower limit value for deactivating partialy filled pipe detection |
621 |
Mass flow offset |
622 |
Mass flow factor |
623 |
Shows the mass flow currently measured |
624 |
Corrected volume flow offset |
625 |
Corrected volume flow factor |
626 |
Shows the corrected volume flow currently calculated |
627 |
Offset 3 |
628 |
Factor 3 |
629 |
Shows the volume flow currently calculated |
630 |
Volume flow offset |
631 |
Volume flow factor |
632 |
Shows the FAD volume flow currently calculated |
633 |
Offset 5 |
634 |
Factor 5 |
635 |
Shows the energy flow currently calculated |
636 |
Temperature offset |
637 |
Temperature factor |
638 |
Shows the medium temperature currently measured |
639 |
Offset 7 |
640 |
Factor 7 |
641 |
Shows the density currently calculated |
642 |
Offset 8 |
643 |
Factor 8 |
644 |
Shows the flow velocity currently measured |
645 |
Offset 9 |
646 |
Factor 9 |
647 |
Shows the heat flow currently calculated |
648 |
Flow override |
649 |
Switch on or off the evaluation of measured values |
650 |
Assign simulation process variable |
651 |
Select a process variable for the simulation process that is activated |
652 |
Process variable value |
653 |
Enter the simulation value for the selected process variable |
654 |
Additional gas component |
655 |
Select additional gas component of biogas to reduce CH4 analysis uncertainty |
656 |
Hydrogen H2 |
657 |
Ammonia NH3 |
658 |
Hydrogen sulfide H2S |
659 |
Calorific value type |
660 |
Select calculation based on gross calorific value or net calorific value |
661 |
Gross calorific value mass |
662 |
Net calorific value mass |
663 |
Delta heat calculation |
664 |
Calculates the transferred heat of a heat exchanger (= delta heat) |
665 |
Device on cold side |
666 |
Device on warm side |
667 |
Density calculation |
668 |
Select the norm the density calculation is based on |
669 |
AGA Nx19 |
670 |
ISO 12213-2 |
671 |
ISO 12213-3 |
672 |
Dew point |
673 |
Enter dew point in the selected temperature unit |
674 |
Enthalpy calculation |
675 |
Select the norm the enthalpy calculation is based on |
676 |
AGA5 |
677 |
ISO 6976 |
678 |
Enthalpy type |
679 |
Define which kind of enthalpy is used |
680 |
Heat |
681 |
Calorific value |
682 |
Linear expansion coefficient |
683 |
Enter linear, medium-specific expansion coefficient for calculating the reference density |
684 |
Enter gross calorific value to calculate the energy flow |
685 |
Fixed density |
686 |
Enter fixed value for medium density |
687 |
Steam quality value |
688 |
Enter fixed value for steam quality |
689 |
Dynamic viscosity |
690 |
Enter the value of dynamic viscosity for a user-specific gas |
691 |
Enter the value of dynamic viscosity for a user-specific liquid |
692 |
Z-factor |
693 |
Enter real gas constant Z for gas under operation conditions |
694 |
Select gas type |
695 |
Select measured gas type |
696 |
Single gas |
697 |
Gas mixture |
698 |
Special gas |
699 |
Liquid type |
700 |
Select measured liquid type |
701 |
Water |
702 |
LPG |
703 |
User-specific liquid |
704 |
Gas composition |
705 |
Select measured gas mixture |
706 |
Air |
707 |
Helium He |
708 |
Neon Ne |
709 |
Argon Ar |
710 |
Krypton Kr |
711 |
Xenon Xe |
712 |
Nitrogen N2 |
713 |
Oxygen O2 |
714 |
Chlorine Cl2 |
715 |
Carbon monoxide CO |
716 |
Carbon dioxide CO2 |
717 |
Hydrogen chloride HCl |
718 |
Methane CH4 |
719 |
Propane C3H8 |
720 |
Ethane C2H6 |
721 |
Butane C4H10 |
722 |
Ethylene C2H4 |
723 |
Ozone O3 |
724 |
Humidity type |
725 |
Select the input value for the gas humidity |
726 |
Relative humidity |
727 |
Water fraction |
728 |
Degrees of superheat limit |
729 |
Select medium |
730 |
Select medium type |
731 |
Gas |
732 |
Liquid |
733 |
Steam |
734 |
Mol% Air |
735 |
Enter amount of substance for the gas mixture |
736 |
Mol% Ar |
737 |
Mol% C2H3Cl |
738 |
Mol% C2H4 |
739 |
Mol% C2H6 |
740 |
Mol% C3H8 |
741 |
Mol% CH4 |
742 |
Mol% Cl2 |
743 |
Mol% CO |
744 |
Mol% CO2 |
745 |
Mol% H2 |
746 |
Mol% H2O |
747 |
Mol% H2S |
748 |
Mol% HCl |
749 |
Mol% He |
750 |
Mol% i-C4H10 |
751 |
Mol% i-C5H12 |
752 |
Mol% Kr |
753 |
Mol% N2 |
754 |
Mol% n-C10H22 |
755 |
Mol% n-C4H10 |
756 |
Mol% n-C5H12 |
757 |
Mol% n-C6H14 |
758 |
Mol% n-C7H16 |
759 |
Mol% n-C8H18 |
760 |
Mol% n-C9H20 |
761 |
Mol% Ne |
762 |
Mol% NH3 |
763 |
Mol% O2 |
764 |
Mol% O3 |
765 |
Mol% other gas |
766 |
Mol% SO2 |
767 |
Mol% Xe |
768 |
Reference combustion temperature |
769 |
Enter reference combustion temperature to calculate the natural gas energy value |
770 |
Select reference temperature for calculation of the gas energy value |
771 |
0 °C |
772 |
15 °C |
773 |
20 °C |
774 |
25 °C |
775 |
60 °F |
776 |
User-defined |
777 |
Reference conditions |
778 |
Select reference conditions for calculation of the corrected volume flow |
779 |
1013.25 mbara, 0 °C |
780 |
1013.25 mbara, 15 °C |
781 |
1013.25 mbara, 20 °C |
782 |
1013.25 mbara, 25 °C |
783 |
1000 mbara, 0 °C |
784 |
1000 mbara, 15 °C |
785 |
1000 mbara, 20 °C |
786 |
1000 mbara, 25 °C |
787 |
14.696 psia, 59 °F |
788 |
14.696 psia, 60 °F |
789 |
FAD conditions |
790 |
Select reference conditions for the calculation of the FAD density (FAD = free air delivery) |
791 |
14.504 psia, 68 °F |
792 |
Reference density |
793 |
Enter fixed value for reference density |
794 |
Reference gross calorific value |
795 |
Enter reference gross calorific value of the natural gas |
796 |
Reference pressure |
797 |
Enter reference pressure for the calulation of the reference density |
798 |
FAD pressure |
799 |
Enter reference pressure for the calulation of the FAD density (FAD = free air delivery) |
800 |
Reference temperature |
801 |
Enter reference temperature for calculating the reference density |
802 |
FAD temperature |
803 |
Enter reference temperature for the calulation of the FAD density (FAD = free air delivery) |
804 |
Reference Z-factor |
805 |
Enter real gas constant Z for gas under reference conditions |
806 |
Relative density |
807 |
Enter a relative density of the natural gas |
808 |
Enter humidity content of air in % |
809 |
Saturated steam calculation mode |
810 |
Select measured gas |
811 |
Special gas name |
812 |
Shows the description of the gas ordered by the customer, e.g. gas name or gas composition |
813 |
|
814 |
Specific heat capacity |
815 |
Enter the specific heat capacity of the medium |
816 |
Standard volume flow type |
817 |
Select whether the water fraction should be included in the standard volume flow calculation or not |
818 |
Wet gas |
819 |
Dry gas |
820 |
Steam calculation mode |
821 |
Saturated steam (T-compensated) |
822 |
Automatic (p-/T-compensated) |
823 |
Steam quality |
824 |
Select compensation mode for steam quality |
825 |
Fixed value |
826 |
Calculated value |
827 |
Burst command 1 |
828 |
Select the HART command that is sent to the HART master |
829 |
Command 1 |
830 |
Command 2 |
831 |
Command 3 |
832 |
Command 9 |
833 |
Command 33 |
834 |
Command 48 |
835 |
Burst command 2 |
836 |
Burst command 3 |
837 |
Burst mode 1 |
838 |
Switch HART burst mode for burst message on |
839 |
Burst mode 2 |
840 |
Burst mode 3 |
841 |
Burst variable 0 |
842 |
For HART command 9 and 33, assign a HART device variable or process variable to burst variable |
843 |
Percent of range |
844 |
Measured current |
845 |
Current input 1 |
846 |
Current input 2 |
847 |
Current input 3 |
848 |
Primary variable (PV) |
849 |
Secondary variable (SV) |
850 |
Tertiary variable (TV) |
851 |
Quaternary variable (QV) |
852 |
HART input |
853 |
Not used |
854 |
Burst variable 1 |
855 |
Burst variable 2 |
856 |
Burst variable 3 |
857 |
Burst variable 4 |
858 |
For HART command 33, assign a HART device variable or process variable to burst variable |
859 |
Burst variable 5 |
860 |
Burst variable 6 |
861 |
Burst variable 7 |
862 |
Max. update period |
863 |
Enter the maximum time span between two burst responses of one burst message |
864 |
Min. update period |
865 |
Enter the minimum time span between two burst responses of one burst message |
866 |
Burst trigger level |
867 |
Enter the burst trigger value that determines together with the option selected in 'Burst trigger mode' parameter the time of burst message |
868 |
Burst trigger mode |
869 |
Select the event that triggers the burst message |
870 |
Continuous |
871 |
Window |
872 |
Rising |
873 |
Falling |
874 |
On change |
875 |
Capture mode |
876 |
Select capture mode via burst or master communication |
877 |
Burst network |
878 |
Master network |
879 |
Assign external process variable |
880 |
Assign variable from external device to process variable
|
881 |
Process pressure |
882 |
Value |
883 |
Shows the value of the device variable recorded by the HART input |
884 |
Shows the status of the device variable recorded by the HART input |
885 |
Manual/Fixed |
886 |
Good |
887 |
Poor accuracy |
888 |
Bad |
889 |
Alarm |
890 |
Defines which current the output assumes in case of an error. |
891 |
Timeout |
892 |
Enter deadline for process variable of external device |
893 |
Burst command |
894 |
Select command to read in external process variable |
895 |
Device ID |
896 |
Enter device ID of external device |
897 |
#.8x |
898 |
Device type |
899 |
Enter device type of external device |
900 |
#.2x |
901 |
Manufacturer ID |
902 |
Enter manufacture ID of external device |
903 |
Slot number |
904 |
Define position of external process variable in burst command |
905 |
Altitude |
906 |
Configuration counter |
907 |
Use this function to display the counter reading for changes to device parameters.
Info:
Static parameters, whose values change during optimization or configuration, cause this parameter to increment by 1. This supports parameter version management. If several parameters change, e. g. due to loading of parameters from FieldCare, etc. in the device, the counter can show a higher value. The counter can never be reset and is not reset to a default value after a device reset. If the counter overflows, (16 bit), it starts again at 1. |
908 |
HART date code |
909 |
Enter data for individual use |
910 |
2009-07-20 |
911 |
HART descriptor |
912 |
Enter description for the measuring point |
913 |
T-MASS 300 500 |
914 |
Shows the device ID for identifying the device in a HART network |
915 |
Shows the device type with which the measuring device is registered with the HART Communication Foundation |
916 |
Event category 832 |
917 |
Change status signal of diagnostic event with diagnostic number 832 'Electronic temperature too high' |
918 |
Failure (F) |
919 |
Function check (C) |
920 |
Out of specification (S) |
921 |
Maintenance required (M) |
922 |
No effect (N) |
923 |
Event category 833 |
924 |
Change status signal of diagnostic event with diagnostic number 833 'Electronic temperature too low' |
925 |
Event category 842 |
926 |
Change status signal of diagnostic event with diagnostic number 842 'Process limit' |
927 |
Event category 834 |
928 |
Change status signal of diagnostic event with diagnostic number 834 'Process temperature too high' |
929 |
Event category 835 |
930 |
Change status signal of diagnostic event with diagnostic number 835 'Process temperature too low' |
931 |
Event category 976 |
932 |
Change status signal of diagnostic event with diagnostic number 976 'Mass flow out of calibrated range' |
933 |
Event category 979 |
934 |
Change status signal of diagnostic event with diagnostic number 979 'Unstable process conditions' |
935 |
Event category 444 |
936 |
Select category for diagnostic message |
937 |
Event category 441 |
938 |
Change status signal of diagnostic event with diagnostic number 441 'Current output' |
939 |
Event category 442 |
940 |
Change status signal of diagnostic event with diagnostic number 442 'Frequency output' |
941 |
Event category 443 |
942 |
Change status signal of diagnostic event with diagnostic number 443 'Pulse output' |
943 |
Event category 977 |
944 |
Event category 144 |
945 |
Change status signal of diagnostic event with diagnostic number 144 'Sensor drift' |
946 |
#.4x |
947 |
Shows the manufacturer ID device is registered with the HART Communication Foundation |
948 |
Fieldbus writing access |
949 |
Select access method to the measuring device via fieldbus |
950 |
Read + write |
951 |
Read only |
952 |
Final assembly number |
953 |
Latitude |
954 |
Location Description |
955 |
somewhere |
956 |
Location method |
957 |
No fix |
958 |
GPS or Standard Positioning Service fix |
959 |
Differential GPS fix |
960 |
Precise positioning service (PPS) fix |
961 |
Real Time Kinetic (RTK) fixed solution |
962 |
Real Time Kinetic (RTK) float solution |
963 |
Estimated dead reckoning |
964 |
Manual input mode |
965 |
Simulation Mode |
966 |
Locking status |
967 |
Longitude |
968 |
Enter a unique name for the measuring point to identify the device quickly within the plant. |
969 |
t-mass |
970 |
HART message |
971 |
Enter HART message which is sent via HART protocol when requested by the master |
972 |
T-MASS 300 500 |
973 |
No. of preambles |
974 |
Defines the number of preambles in the HART telegram |
975 |
HART address |
976 |
Enter adress for the data exchange via HART protocol |
977 |
Process Unit Tag |
978 |
Process Unit Tag |
979 |
Assign PV |
980 |
Assign measured variable to primary dynamic variable (PV) |
981 |
Shows the current measured value of the primary dynamic variable (PV) |
982 |
Assign QV |
983 |
Assign measured variable to quaternary (fourth) dynamic variable (QV) |
984 |
Shows the current measured value of the quaternary (fourth) dynamic variable (QV) |
985 |
Device revision |
986 |
Shows the device revision with which the device is registered with the HART Communication Foundation |
987 |
HART revision |
988 |
Shows the HART protocol revision of the measuring device |
989 |
Hardware revision |
990 |
Shows the hardware revision of the measuring device |
991 |
Software revision |
992 |
Shows software revision of the measuring device |
993 |
Assign SV |
994 |
Assign measured variable to the second dynamic variable (SV) |
995 |
Shows the current measured value of the secondary dynamic variable (SV) |
996 |
HART short tag |
997 |
Enter a brief description for the measuring point |
998 |
T-MASS |
999 |
Assign TV |
1000 |
Assign measured variable to the third dynamic variable (TV) |
1001 |
Shows the current measured value of the tertiary (third) dynamic variable (TV) |
1002 |
External verification flags |
1003 |
External verification output 1 |
1004 |
External verification output 2 |
1005 |
External verification output 3 |
1006 |
External verification output 4 |
1007 |
Date/time |
1008 |
Overall result |
1009 |
Passed |
1010 |
Not done |
1011 |
Not plugged |
1012 |
Failed |
1013 |
External device information |
1014 |
Enter unique information e.g. serial number of the used measuring equipment |
1015 |
Unknown device |
1016 |
Measured values |
1017 |
Enter the displayed value of the external measuring equipment |
1018 |
Operating time |
1019 |
Indicates how long the device has been in operation |
1020 |
Start verification |
1021 |
Start verification |
1022 |
Start |
1023 |
Output 1 low value |
1024 |
Output 1 high value |
1025 |
Output 2 low value |
1026 |
Output 2 high value |
1027 |
Output 3 low value |
1028 |
Output 3 high value |
1029 |
Output 4 low value |
1030 |
Output 4 high value |
1031 |
Frequency output 1 |
1032 |
Pulse output 1 |
1033 |
Frequency output 2 |
1034 |
Pulse output 2 |
1035 |
Frequency output 3 |
1036 |
Double pulse output |
1037 |
Power coefficient fluctuation |
1038 |
Output values |
1039 |
Shows the simulated value dependent on the selected output |
1040 |
Verification ID |
1041 |
Shows the verification ID of the verification report for an unique assignment |
1042 |
Shows the entered date and time |
1043 |
I/O module |
1044 |
Shows the overall result for the "I/O module" test group |
1045 |
Verification mode |
1046 |
Select verification mode |
1047 |
Standard verification |
1048 |
Extended verification |
1049 |
Shows the overall result of the verification |
1050 |
Sensor electronic module (ISEM) |
1051 |
Shows the overall result for the "sensor electronic module" test group |
1052 |
Sensor |
1053 |
Shows the overall result for the "sensor" test group |
1054 |
Shows the actual status |
1055 |
Done |
1056 |
Busy |
1057 |
System status |
1058 |
Shows the result of the system condition monitoring |
1059 |
Totalizer overflow |
1060 |
Shows the current overflow of the inventory counter |
1061 |
Unit |
1062 |
Shows the unit for the inventory counter |
1063 |
Totalizer value |
1064 |
Shows the current sum of the main measured value. The raw value of the main measured value is totalized. |
1065 |
Resource available |
1066 |
Bootloader revision |
1067 |
Shows the bootloader revision of the module firmware |
1068 |
Build no. software |
1069 |
Shows the build number of the module firmware |
1070 |
Shows the software revision of the module |
1071 |
Shows the hardware revision of the module |
1072 |
- none - |
1073 |
Module name |
1074 |
Shows the name of the module |
1075 |
Serial number |
1076 |
Shows the serial number of the module |
1077 |
AAFFFFAAFFF |
1078 |
PulseFrequencyState_ActInstance |
1079 |
Assign flow direction check |
1080 |
Select process variable for flow direction monitoring |
1081 |
Set reaction time for output signal to fluctuations in the measured value |
1082 |
Define output behavior in alarm condition |
1083 |
0 Hz |
1084 |
Failure frequency |
1085 |
Enter frequency output value in alarm condition |
1086 |
Assign frequency output |
1087 |
Select process variable for frequency output |
1088 |
Maximum frequency value |
1089 |
Enter maximum frequency |
1090 |
Measuring value at maximum frequency |
1091 |
Enter measured value for maximum frequency |
1092 |
Select measuring mode for pulse output |
1093 |
Minimum frequency value |
1094 |
Enter minimum frequency |
1095 |
Measuring value at minimum frequency |
1096 |
Enter measured value for minmum frequency |
1097 |
Output frequency 1 |
1098 |
Shows the value currently measured for the frequency output |
1099 |
Output frequency 2 |
1100 |
Output frequency 3 |
1101 |
Frequency output simulation 1 |
1102 |
Switch the simulation of the frequency output on and off |
1103 |
Frequency output simulation 2 |
1104 |
Frequency output simulation 3 |
1105 |
Frequency value 1 |
1106 |
Enter the frequency value for the simulation |
1107 |
Frequency value 2 |
1108 |
Frequency value 3 |
1109 |
Assign limit |
1110 |
Select process variable for limit function |
1111 |
Assign diagnostic behavior |
1112 |
Select diagnostic behavior for switch output |
1113 |
Alarm or warning |
1114 |
Warning |
1115 |
Operating mode |
1116 |
Define the output as a pulse, frequency or switch output |
1117 |
Pulse |
1118 |
Frequency |
1119 |
Switch |
1120 |
Invert output signal |
1121 |
'No'
The switch output behaves as per its parameter setting.
'Yes'
The switching behavior is inverted as compared to its parameter setting. |
1122 |
Select the signal mode for the PFS output |
1123 |
Passive NAMUR |
1124 |
Response time |
1125 |
Specifies how quickly the output reaches the measured value change of 63 % of 100 % of the measured value change |
1126 |
No pulses |
1127 |
Assign pulse output 1 |
1128 |
Select process variable for pulse output |
1129 |
Assign pulse output 2 |
1130 |
Assign pulse output 3 |
1131 |
Shows the currently output pulse frequency |
1132 |
Pulse output 3 |
1133 |
Pulse output simulation 1 |
1134 |
Set and switch off the pulse output simulation |
1135 |
Down-counting value |
1136 |
Pulse output simulation 2 |
1137 |
Pulse output simulation 3 |
1138 |
Pulse value 1 |
1139 |
Enter the number of pulses for simulation |
1140 |
Pulse value 2 |
1141 |
Pulse value 3 |
1142 |
Pulse scaling |
1143 |
Enter quantity for measured value at which a pulse is output |
1144 |
Pulse width |
1145 |
Define time width of the output pulse |
1146 |
Actual status |
1147 |
Open |
1148 |
Closed |
1149 |
Switch output function |
1150 |
Select function for switch output |
1151 |
Diagnostic behavior |
1152 |
Limit |
1153 |
Flow direction check |
1154 |
Switch status 1 |
1155 |
Shows the current switch output status |
1156 |
Switch status 2 |
1157 |
Switch status 3 |
1158 |
Switch output simulation 1 |
1159 |
'On'
The switch output simulation is active. The status of the switch output does not correspond to the state of the device (e.g. limit violation or alarm) but is directly defined in the 'Switch output status' parameter.
'Off'
The switch output simulation is not active. The status of the switch output corresponds to the state of the device (e.g. limit violation or alarm). |
1160 |
Switch output simulation 2 |
1161 |
Switch output simulation 3 |
1162 |
Current status of the switch output. |
1163 |
Switch-off delay |
1164 |
Defines the delay applied before the output is switched off. |
1165 |
Switch-off value |
1166 |
Enter measured value for the switch-off point |
1167 |
Switch-on delay |
1168 |
Defines the delay applied before the output is switched on. |
1169 |
Switch-on value |
1170 |
Enter measured value for the switch-on point |
1171 |
Assign status |
1172 |
Select device status for switch output |
1173 |
Low flow cut off |
1174 |
Shows the terminal numbers used by the PFS output module |
1175 |
Parameter error |
1176 |
Shows the parameter that failed to meet the preconditions |
1177 |
Installation factor |
1178 |
Zero point |
1179 |
Activate in-situ adjustment |
1180 |
Active gas |
1181 |
Pipe shape |
1182 |
Pipe inner diameter |
1183 |
Character test string |
1184 |
Check the shown character string for correct representations of the characters and digits |
1185 |
0123456789+-,. |
1186 |
Confirm Character Test |
1187 |
SIL confirmation |
1188 |
SIL preparation |
1189 |
Shows the actual status of the verification of the preconditions |
1190 |
In progress |
1191 |
Finished |
1192 |
Check and confirm or refuse displayed setting |
1193 |
4 mA value |
1194 |
|
1195 |
Output mode |
1196 |
Damping |
1197 |
Pressure value |
1198 |
Gas type |
1199 |
Assign low flow cutoff |
1200 |
Coal gas/bio gas |
1201 |
Natural gas |
1202 |
Natural gas - using sound velocity |
1203 |
User-specific gas |
1204 |
Insertion depth |
1205 |
SIL status |
1206 |
Not active |
1207 |
SIL sequence active |
1208 |
Code incorrect |
1209 |
Abort SIL confirmation sequence or reenter SIL locking code |
1210 |
Reenter code |
1211 |
Abort sequence |
1212 |
Enter access code |
1213 |
Enter access code to disable write protection of parameters |
1214 |
Confirm access code |
1215 |
Confirm the entered access code |
1216 |
Define access code |
1217 |
Restrict write-access to parameters to protect the configuration of the device against unintentional changes |
1218 |
ChangeLoginPasswordState 1 |
1219 |
NoEncryptionNeeded |
1220 |
CurrentLoginCodeValid |
1221 |
LoginCodeFirstValid |
1222 |
LoginCodeSecondvalid |
1223 |
Customized |
1224 |
Firmware version |
1225 |
Shows the device firmware version installed |
1226 |
01.00 |
1227 |
Extended order code 1 |
1228 |
Use this function to display the first, second and/or third part of the extended order code. On account of length restrictions, the extended order code is split into a maximum of 3 parameters. The extended order code indicates the version of all the features of the product structure for the device and thus uniquely identifies the device. It can also be found on the nameplate.
Info:
Uses of the extended order code
- To order an identical spare device.
- To check the ordered device features against the shipping note. |
1229 |
-------------------- |
1230 |
Extended order code 2 |
1231 |
Extended order code 3 |
1232 |
Order code |
1233 |
Shows the device order code |
1234 |
- none - |
1235 |
The serial number is a unique alphanumerical code identifying the device.
It is printed on the nameplate.
In combination with the Operations app it allows to access all device related documentation. |
1236 |
79AFFF16000 |
1237 |
Enter the name for the measuring point |
1238 |
t-mass |
1239 |
ENP version |
1240 |
Shows the version of the electronic nameplate (ENP) |
1241 |
2.02.00 |
1242 |
Device name |
1243 |
Shows the name of the transmitter |
1244 |
t-mass 300 500 |
1245 |
XML build number |
1246 |
Languages supported |
1247 |
Deutsch |
1248 |
Nederlands |
1249 |
Français |
1250 |
Bahasa Indonesia |
1251 |
Italiano |
1252 |
Polski |
1253 |
Portuguesa |
1254 |
Español |
1255 |
Svenska |
1256 |
Türkçe |
1257 |
Activate SW option |
1258 |
Enter the application package code or code of another re-ordered functionality to enable it |
1259 |
Indicates the write protection with the highest priority that is currently active |
1260 |
Hardware locked |
1261 |
SIL locked |
1262 |
Temporarily locked |
1263 |
Device reset |
1264 |
Reset the device configuration - either entirely or in part - to a defined state |
1265 |
To delivery settings |
1266 |
Restart device |
1267 |
Delete powerfail data |
1268 |
Delete T-DAT |
1269 |
Delete HistoROM backup |
1270 |
Reset faulty parameters |
1271 |
Delete delivery settings |
1272 |
Restore S-DAT backup |
1273 |
Reset access code |
1274 |
Reset access code to factory settings |
1275 |
0x00 |
1276 |
Reset write protection |
1277 |
Reset write protection code |
1278 |
Set write protection |
1279 |
Enter SIL locking code |
1280 |
Software option overview |
1281 |
Shows all enabled software options |
1282 |
Extended HistoROM |
1283 |
SIL |
1284 |
Heartbeat Verification |
1285 |
Second gas |
1286 |
Heartbeat Monitoring |
1287 |
SW option enabled overview |
1288 |
UDL features |
1289 |
Upload support |
1290 |
Download support |
1291 |
Multibuffer support |
1292 |
UDL operation |
1293 |
Initiate upload |
1294 |
Download to different device |
1295 |
Download to identical device |
1296 |
Abort up-/download |
1297 |
Terminate up-/download |
1298 |
Confirm download status |
1299 |
UDL status |
1300 |
Up-/download inactive |
1301 |
Download temporary impossible |
1302 |
Upload active |
1303 |
Download active |
1304 |
Up-/Download verification active |
1305 |
Download succeeded |
1306 |
Download terminated with warnings |
1307 |
Download failed |
1308 |
Access status |
1309 |
Shows the role the user is currently logged in. The role defines his access authorization to parameters. |
1310 |
Operator |
1311 |
Maintenance |
1312 |
Service |
1313 |
Production |
1314 |
Development |
1315 |
StateInput_ActInstance |
1316 |
Active level |
1317 |
Define input signal level at which the assigned function is triggered |
1318 |
High |
1319 |
Low |
1320 |
Assign status input |
1321 |
Select function for the status input |
1322 |
Reset totalizer 1 |
1323 |
Reset totalizer 2 |
1324 |
Reset totalizer 3 |
1325 |
Gas group |
1326 |
Zero point adjustment |
1327 |
Value status input |
1328 |
Shows the current input signal level |
1329 |
Response time status input |
1330 |
Define the minimum amount of time the input signal level must be present before the selected function is triggered |
1331 |
Status input simulation 1 |
1332 |
Switch simulation of the status input on and off |
1333 |
Status input simulation 2 |
1334 |
Status input simulation 3 |
1335 |
Input signal level 1 |
1336 |
Select the signal level for the simulation of the status input |
1337 |
Input signal level 2 |
1338 |
Input signal level 3 |
1339 |
Shows the terminal numbers used by the status input module |
1340 |
Alarm delay |
1341 |
Enter time interval. Only after the expiration of this time interval the device generates certain diagnostic messages. |
1342 |
Clear event list |
1343 |
Delete all entries of the event list |
1344 |
Clear data |
1345 |
Status signal |
1346 |
OK |
1347 |
--- |
1348 |
Actual diagnostics |
1349 |
Shows the current occured diagnostic event along with its diagnostic information |
1350 |
-------- |
1351 |
C431 Trim 1 |
1352 |
C431 Trim 2 |
1353 |
C431 Trim 3 |
1354 |
C431 Trim 4 |
1355 |
C491 Current output 1 simulation |
1356 |
C491 Current output 2 simulation |
1357 |
C491 Current output 3 simulation |
1358 |
C491 Current output 4 simulation |
1359 |
F882 Input signal |
1360 |
F281 Electronic initialization |
1361 |
I1079 Sensor changed |
1362 |
I1089 Power on |
1363 |
I1090 Configuration reset |
1364 |
I1091 Configuration changed |
1365 |
I1092 HistoROM backup deleted |
1366 |
F437 Configuration incompatible |
1367 |
F242 Software incompatible |
1368 |
M438 Dataset |
1369 |
F252 Modules incompatible |
1370 |
F270 Main electronic failure |
1371 |
F272 Main electronic failure |
1372 |
F275 I/O module 1 defective |
1373 |
F275 I/O module 2 defective |
1374 |
F275 I/O module 3 defective |
1375 |
F275 I/O module 4 defective |
1376 |
F276 I/O module 1 faulty |
1377 |
F276 I/O module 2 faulty |
1378 |
F276 I/O module 3 faulty |
1379 |
F276 I/O module 4 faulty |
1380 |
F271 Main electronic failure |
1381 |
I1137 Electronic changed |
1382 |
F442 Frequency output 1 |
1383 |
442 Frequency output 1 |
1384 |
M442 Frequency output 1 |
1385 |
C442 Frequency output 1 |
1386 |
S442 Frequency output 1 |
1387 |
F442 Frequency output 2 |
1388 |
442 Frequency output 2 |
1389 |
M442 Frequency output 2 |
1390 |
C442 Frequency output 2 |
1391 |
S442 Frequency output 2 |
1392 |
F442 Frequency output 3 |
1393 |
442 Frequency output 3 |
1394 |
M442 Frequency output 3 |
1395 |
C442 Frequency output 3 |
1396 |
S442 Frequency output 3 |
1397 |
F410 Data transfer |
1398 |
F443 Pulse output 1 |
1399 |
443 Pulse output 1 |
1400 |
M443 Pulse output 1 |
1401 |
C443 Pulse output 1 |
1402 |
S443 Pulse output 1 |
1403 |
F443 Pulse output 2 |
1404 |
443 Pulse output 2 |
1405 |
M443 Pulse output 2 |
1406 |
C443 Pulse output 2 |
1407 |
S443 Pulse output 2 |
1408 |
F443 Pulse output 3 |
1409 |
443 Pulse output 3 |
1410 |
M443 Pulse output 3 |
1411 |
C443 Pulse output 3 |
1412 |
S443 Pulse output 3 |
1413 |
C492 Simulation frequency output 1 |
1414 |
C492 Simulation frequency output 2 |
1415 |
C492 Simulation frequency output 3 |
1416 |
C493 Pulse output 1 simulation active |
1417 |
C493 Pulse output 2 simulation active |
1418 |
C493 Pulse output 3 simulation active |
1419 |
C494 Switch output simulation 1 |
1420 |
C494 Switch output simulation 2 |
1421 |
C494 Switch output simulation 3 |
1422 |
C484 Failure mode simulation |
1423 |
F842 Process limit |
1424 |
842 Process limit |
1425 |
M842 Process limit |
1426 |
C842 Process limit |
1427 |
S842 Process limit |
1428 |
C485 Measured variable simulation |
1429 |
C453 Flow override |
1430 |
F361 I/O module 1 faulty |
1431 |
F361 I/O module 2 faulty |
1432 |
F361 I/O module 3 faulty |
1433 |
F361 I/O module 4 faulty |
1434 |
I1151 History reset |
1435 |
F273 Main electronic failure |
1436 |
F441 Current output 1 |
1437 |
441 Current output 1 |
1438 |
M441 Current output 1 |
1439 |
C441 Current output 1 |
1440 |
S441 Current output 1 |
1441 |
F441 Current output 2 |
1442 |
441 Current output 2 |
1443 |
M441 Current output 2 |
1444 |
C441 Current output 2 |
1445 |
S441 Current output 2 |
1446 |
F441 Current output 3 |
1447 |
441 Current output 3 |
1448 |
M441 Current output 3 |
1449 |
C441 Current output 3 |
1450 |
S441 Current output 3 |
1451 |
F441 Current output 4 |
1452 |
441 Current output 4 |
1453 |
M441 Current output 4 |
1454 |
C441 Current output 4 |
1455 |
S441 Current output 4 |
1456 |
I1155 Reset electronic temperature |
1457 |
I1156 Memory error trend |
1458 |
I1157 Memory error event list |
1459 |
F083 Memory content |
1460 |
F803 Current loop |
1461 |
F833 Electronic temperature too low |
1462 |
833 Electronic temperature too low |
1463 |
M833 Electronic temperature too low |
1464 |
C833 Electronic temperature too low |
1465 |
S833 Electronic temperature too low |
1466 |
F832 Electronic temperature too high |
1467 |
832 Electronic temperature too high |
1468 |
M832 Electronic temperature too high |
1469 |
C832 Electronic temperature too high |
1470 |
S832 Electronic temperature too high |
1471 |
F834 Process temperature too high |
1472 |
834 Process temperature too high |
1473 |
M834 Process temperature too high |
1474 |
C834 Process temperature too high |
1475 |
S834 Process temperature too high |
1476 |
F835 Process temperature too low |
1477 |
835 Process temperature too low |
1478 |
M835 Process temperature too low |
1479 |
C835 Process temperature too low |
1480 |
S835 Process temperature too low |
1481 |
F372 Sensor electronic (ISEM) faulty |
1482 |
I1221 Zero point adjust failure |
1483 |
I1222 Zero point adjustment ok |
1484 |
F283 Memory content |
1485 |
M311 Electronic failure |
1486 |
F082 Data storage |
1487 |
I1256 Display: access status changed |
1488 |
F375 I/O-1 communication failed |
1489 |
F375 I/O-2 communication failed |
1490 |
F375 I/O-3 communication failed |
1491 |
F375 I/O-4 communication failed |
1492 |
I1264 Safety sequence aborted |
1493 |
I1278 I/O module restarted |
1494 |
F262 Sensor electronic connection faulty |
1495 |
F537 Configuration |
1496 |
F201 Device failure |
1497 |
S961 Delta temperature |
1498 |
I1335 Firmware changed |
1499 |
C495 Diagnostic event simulation |
1500 |
I1361 Web server: login failed |
1501 |
F382 Data storage |
1502 |
F383 Memory content |
1503 |
C496 Status input simulation |
1504 |
I1397 Fieldbus: access status changed |
1505 |
I1398 CDI: access status changed |
1506 |
I1444 Device verification passed |
1507 |
I1445 Device verification failed |
1508 |
I1457 Measurement error verification failed |
1509 |
I1459 I/O module verification failed |
1510 |
I1461 Sensor verification failed |
1511 |
I1462 Sensor electronic module verific. failed |
1512 |
S539 Flow computer configuration incorrect |
1513 |
F444 Current input 1 |
1514 |
444 Current input 1 |
1515 |
M444 Current input 1 |
1516 |
C444 Current input 1 |
1517 |
S444 Current input 1 |
1518 |
F444 Current input 2 |
1519 |
444 Current input 2 |
1520 |
M444 Current input 2 |
1521 |
C444 Current input 2 |
1522 |
S444 Current input 2 |
1523 |
F444 Current input 3 |
1524 |
444 Current input 3 |
1525 |
M444 Current input 3 |
1526 |
C444 Current input 3 |
1527 |
S444 Current input 3 |
1528 |
C486 Current input 1 simulation |
1529 |
C486 Current input 2 simulation |
1530 |
C486 Current input 3 simulation |
1531 |
C302 Device verification in progress |
1532 |
I1512 Download started |
1533 |
I1513 Download finished |
1534 |
I1514 Upload started |
1535 |
I1515 Upload finished |
1536 |
C412 Processing download |
1537 |
I1554 Safety sequence started |
1538 |
I1555 Safety sequence confirmed |
1539 |
I1556 Safety mode off |
1540 |
I1618 I/O module replaced |
1541 |
I1619 I/O module replaced |
1542 |
M303 I/O 1 configuration changed |
1543 |
M303 I/O 2 configuration changed |
1544 |
M303 I/O 3 configuration changed |
1545 |
M303 I/O 4 configuration changed |
1546 |
I1621 I/O module replaced |
1547 |
I1622 Calibration changed |
1548 |
I1624 Reset all totalizers |
1549 |
I1625 Write protection activated |
1550 |
I1626 Write protection deactivated |
1551 |
I1627 Web server: login successful |
1552 |
I1628 Display: login successful |
1553 |
I1629 CDI: login successful |
1554 |
F520 I/O 1 hardware configuration invalid |
1555 |
F520 I/O 2 hardware configuration invalid |
1556 |
F520 I/O 3 hardware configuration invalid |
1557 |
F520 I/O 4 hardware configuration invalid |
1558 |
I1631 Web server access changed |
1559 |
I1632 Display: login failed |
1560 |
I1633 CDI: login failed |
1561 |
I1634 Reset to factory settings |
1562 |
I1635 Reset to delivery settings |
1563 |
I1639 Max. switch cycles number reached |
1564 |
F387 HistoROM data faulty |
1565 |
I1649 Hardware write protection activated |
1566 |
I1650 Hardware write protection deactivated |
1567 |
C594 Relay output simulation |
1568 |
F332 Writing in HistoROM backup failed |
1569 |
I1712 New flash file received |
1570 |
M330 Flash file invalid |
1571 |
F331 Firmware update failed |
1572 |
F373 Sensor electronic (ISEM) faulty |
1573 |
I1725 Sensor electronic module (ISEM) changed |
1574 |
I1726 Configuration backup failed |
1575 |
F979 Unstable process conditions |
1576 |
979 Unstable process conditions |
1577 |
M979 Unstable process conditions |
1578 |
C979 Unstable process conditions |
1579 |
S979 Unstable process conditions |
1580 |
F144 Sensor drift |
1581 |
144 Sensor drift |
1582 |
M144 Sensor drift |
1583 |
C144 Sensor drift |
1584 |
S144 Sensor drift |
1585 |
F004 Sensor error |
1586 |
F378 Supply voltage ISEM faulty |
1587 |
F976 Mass flow out of calibrated range |
1588 |
976 Mass flow out of calibrated range |
1589 |
M976 Mass flow out of calibrated range |
1590 |
C976 Mass flow out of calibrated range |
1591 |
S976 Mass flow out of calibrated range |
1592 |
F977 Reverse flow detected |
1593 |
977 Reverse flow detected |
1594 |
M977 Reverse flow detected |
1595 |
C977 Reverse flow detected |
1596 |
S977 Reverse flow detected |
1597 |
S941 Flow velocity too high |
1598 |
Displays the timestamp for the currently active diagnostic message |
1599 |
I/O capabilities |
1600 |
Current output |
1601 |
Exi |
1602 |
Event category 1 |
1603 |
Timestamp of the diagnostic message. |
1604 |
Event category 2 |
1605 |
Event category 3 |
1606 |
Event category 4 |
1607 |
Event category 5 |
1608 |
Diagnostics 1 |
1609 |
Displays the currently active diagnostic message with the highest priority. |
1610 |
Diagnostics 2 |
1611 |
Displays the currently active diagnostic message with the second highest priority. |
1612 |
Diagnostics 3 |
1613 |
Shows the currently active diagnostic message with the third highest priority. |
1614 |
Diagnostics 4 |
1615 |
Shows the currently active diagnostic message with the fourth highest priority. |
1616 |
Diagnostics 5 |
1617 |
Shows the currently active diagnostic message with the fifth-highest priority. |
1618 |
Update Event |
1619 |
ElectronicTempSensorAvailable 1 |
1620 |
Assign behavior of diagnostic no. 832 |
1621 |
Change behavior of diagnostic event with diagnostic number 832 'Electronic temperature too high' |
1622 |
Logbook entry only |
1623 |
Assign behavior of diagnostic no. 833 |
1624 |
Change behavior of diagnostic event with diagnostic number 833 'Electronic temperature too low' |
1625 |
Assign behavior of diagnostic no. 976 |
1626 |
Change behavior of diagnostic event with diagnostic number 976 'Mass flow out of calibrated range' |
1627 |
Assign behavior of diagnostic no. 842 |
1628 |
Change behavior of diagnostic event with diagnostic number 842 'Process limit' |
1629 |
Assign behavior of diagnostic no. 834 |
1630 |
Change behavior of diagnostic event with diagnostic number 834 'Process temperature too high' |
1631 |
Assign behavior of diagnostic no. 835 |
1632 |
Change behavior of diagnostic event with diagnostic number 835 'Process temperature too low' |
1633 |
Assign behavior of diagnostic no. 979 |
1634 |
Change behavior of diagnostic event with diagnostic number 979 'Unstable process conditions' |
1635 |
Assign behavior of diagnostic no. 444 |
1636 |
Change behavior of diagnistic event with diagnostic number 444 'Current input' |
1637 |
Assign behavior of diagnostic no. 441 |
1638 |
Change behavior of diagnostic event with diagnostic number 441 'Current output' |
1639 |
Assign behavior of diagnostic no. 442 |
1640 |
Change behavior of diagnostic event with diagnostic number 442 'Frequency output' |
1641 |
Assign behavior of diagnostic no. 443 |
1642 |
Change behavior of diagnostic event with diagnostic number 443 'Pulse output' |
1643 |
Assign behavior of diagnostic no. 977 |
1644 |
Change behavior of diagnostic event with diagnostic number 977 'Reverse flow detected' |
1645 |
Assign behavior of diagnostic no. 144 |
1646 |
Change behavior of diagnostic event with diagnostic number 144 'Sensor drift' |
1647 |
Assign behavior of diagnostic no. 302 |
1648 |
Change behavior of diagnostic event with diagnostic number 302 'Device verification in progress' |
1649 |
Prepare state |
1650 |
Filter options |
1651 |
Define which category of event messages is shown in the Events list submenu |
1652 |
All |
1653 |
Out of specification (S) |
1654 |
Information (I) |
1655 |
PE_method_read_event |
1656 |
Entries list |
1657 |
Operating time from restart |
1658 |
Shows the time the device has been in operation since the last device restart |
1659 |
Previous diagnostics |
1660 |
Shows the diagnostic event that occurred prior to the current diagnostic event along with its diagnostic information |
1661 |
Shows the timestamp of the previous diagnostic message |
1662 |
Diagnostic event simulation |
1663 |
Select a diagnostic event to simulate this event |
1664 |
004 Sensor error |
1665 |
082 Data storage |
1666 |
083 Memory content |
1667 |
201 Device failure |
1668 |
242 Software incompatible |
1669 |
252 Modules incompatible |
1670 |
262 Sensor electronic connection faulty |
1671 |
270 Main electronic failure |
1672 |
271 Main electronic failure |
1673 |
272 Main electronic failure |
1674 |
273 Main electronic failure |
1675 |
275 I/O module 1 defective |
1676 |
275 I/O module 2 defective |
1677 |
275 I/O module 3 defective |
1678 |
275 I/O module 4 defective |
1679 |
276 I/O module 1 faulty |
1680 |
276 I/O module 2 faulty |
1681 |
276 I/O module 3 faulty |
1682 |
276 I/O module 4 faulty |
1683 |
281 Electronic initialization |
1684 |
283 Memory content |
1685 |
302 Device verification in progress |
1686 |
303 I/O 1 configuration changed |
1687 |
303 I/O 2 configuration changed |
1688 |
303 I/O 3 configuration changed |
1689 |
303 I/O 4 configuration changed |
1690 |
311 Electronic failure |
1691 |
330 Flash file invalid |
1692 |
331 Firmware update failed |
1693 |
332 Writing in HistoROM backup failed |
1694 |
361 I/O module 1 faulty |
1695 |
361 I/O module 2 faulty |
1696 |
361 I/O module 3 faulty |
1697 |
361 I/O module 4 faulty |
1698 |
372 Sensor electronic (ISEM) faulty |
1699 |
373 Sensor electronic (ISEM) faulty |
1700 |
375 I/O-1 communication failed |
1701 |
375 I/O-2 communication failed |
1702 |
375 I/O-3 communication failed |
1703 |
375 I/O-4 communication failed |
1704 |
378 Supply voltage ISEM faulty |
1705 |
382 Data storage |
1706 |
383 Memory content |
1707 |
387 HistoROM data faulty |
1708 |
410 Data transfer |
1709 |
412 Processing download |
1710 |
431 Trim 1 |
1711 |
431 Trim 2 |
1712 |
431 Trim 3 |
1713 |
431 Trim 4 |
1714 |
437 Configuration incompatible |
1715 |
438 Dataset |
1716 |
453 Flow override |
1717 |
484 Failure mode simulation |
1718 |
485 Measured variable simulation |
1719 |
486 Current input 1 simulation |
1720 |
486 Current input 2 simulation |
1721 |
486 Current input 3 simulation |
1722 |
491 Current output 1 simulation |
1723 |
491 Current output 2 simulation |
1724 |
491 Current output 3 simulation |
1725 |
491 Current output 4 simulation |
1726 |
492 Simulation frequency output 1 |
1727 |
492 Simulation frequency output 2 |
1728 |
492 Simulation frequency output 3 |
1729 |
493 Pulse output 1 simulation active |
1730 |
493 Pulse output 2 simulation active |
1731 |
493 Pulse output 3 simulation active |
1732 |
494 Switch output simulation 1 |
1733 |
494 Switch output simulation 2 |
1734 |
494 Switch output simulation 3 |
1735 |
496 Status input simulation |
1736 |
520 I/O 1 hardware configuration invalid |
1737 |
520 I/O 2 hardware configuration invalid |
1738 |
520 I/O 3 hardware configuration invalid |
1739 |
520 I/O 4 hardware configuration invalid |
1740 |
537 Configuration |
1741 |
539 Flow computer configuration incorrect |
1742 |
594 Relay output simulation |
1743 |
803 Current loop |
1744 |
882 Input signal |
1745 |
941 Flow velocity too high |
1746 |
961 Delta temperature |
1747 |
Enter service ID of diagnostic event to simulate this event |
1748 |
Device alarm simulation |
1749 |
Switch the device alarm on and off |
1750 |
SwitchOutput_ActInstance |
1751 |
Defines the state of the switch output in case of an error. |
1752 |
Relay output function |
1753 |
Select the function for the relay output |
1754 |
Digital Output |
1755 |
Defines which process variable will be checked for limit violation. |
1756 |
Max. switch cycles number |
1757 |
Shows the maximal number of guaranteed switch cycles |
1758 |
Defines to which behavior of diagnostic events the switch output reacts. |
1759 |
Switch cycles |
1760 |
Shows number of all performed switch cycles |
1761 |
Switch status |
1762 |
Relay output 1 simulation |
1763 |
Relay output 2 simulation |
1764 |
Relay output 3 simulation |
1765 |
Select status of the relay output for the simulation |
1766 |
Defines the switch-off point.
The output is opened if the assigned process variable falls below this point. |
1767 |
Defines the switch-on point.
The output is closed if the assigned process variable rises above this point. |
1768 |
Shows the terminal numbers used by the relay output module |
1769 |
Powerless relay status |
1770 |
Select quietscent state for relay |
1771 |
Calorific value unit |
1772 |
Select calorific value unit |
1773 |
Corrected volume unit |
1774 |
Select corrected volume unit |
1775 |
Corrected volume flow unit |
1776 |
Select corrected volume flow unit |
1777 |
Density unit |
1778 |
Select density unit |
1779 |
Dynamic viscosity unit |
1780 |
Select dynamic viscosity unit |
1781 |
Energy unit |
1782 |
Select energy unit |
1783 |
Energy flow unit |
1784 |
Select energy flow unit |
1785 |
FAD volume unit |
1786 |
Select FAD volumen unit (FAD = free air delivery) |
1787 |
FAD volume flow unit |
1788 |
Select FAD volumen flow unit (FAD = free air delivery) |
1789 |
Length unit |
1790 |
Select length unit for nominal diameter |
1791 |
Mass unit |
1792 |
Select mass unit |
1793 |
Mass flow unit |
1794 |
Select mass flow unit |
1795 |
Pressure unit |
1796 |
Select process pressure unit |
1797 |
Reference density unit |
1798 |
Select reference density unit |
1799 |
Specific enthalpy |
1800 |
Specific heat capacity unit |
1801 |
Select unit for specific heat capacity |
1802 |
Temperature unit |
1803 |
Select temperature unit |
1804 |
TemperatureDifference 1 |
1805 |
Velocity unit |
1806 |
Select velocity unit |
1807 |
Volume unit |
1808 |
Select volume unit |
1809 |
Volume flow unit |
1810 |
Select volume flow unit |
1811 |
Maximum value |
1812 |
Shows the highest previously measured temperature for the main electronic module in the transmitter |
1813 |
Minimum value |
1814 |
Shows the lowest previously measured temperature for the main electronic module in the transmitter |
1815 |
Indication of the current temperature of the electronics. |
1816 |
Gas component |
1817 |
Select the gas component that is measured by an external gas analyzer |
1818 |
Mol% |
1819 |
Gas compensation |
1820 |
Select the input type for gas compensation. The selected gas component is measured by an external gas analyzer |
1821 |
External value |
1822 |
Measurement application |
1823 |
Select measurement application |
1824 |
Air or compressed air |
1825 |
Gas or gas mixture |
1826 |
Energy |
1827 |
Shows the currently calculated gross calorific value or net calorific value |
1828 |
Shows the currently calculated dynamic viscosity |
1829 |
Select the gas that the device is currently using for the measurement |
1830 |
FluidGasGroupSelectState |
1831 |
Ok |
1832 |
Heat transfer coefficient |
1833 |
Shows the heat transfer coefficient currently calculated |
1834 |
Mach number |
1835 |
Shows the Mach number currently calculated. For the calculation the density and the pressure are required. |
1836 |
Nusselt number |
1837 |
Shows the Nusselt number currently calculated |
1838 |
Prandtl number |
1839 |
Shows the currently calculated Prandtl number |
1840 |
Shows depending on the setting the entered or external process pressure |
1841 |
Enter fixed value for the process pressure |
1842 |
External pressure |
1843 |
Shows the external process pressure value |
1844 |
Pressure compensation |
1845 |
Select pressure compensation type |
1846 |
Shows the currently calculated reference density |
1847 |
FAD density |
1848 |
Shows the currently calculated FAD density (FAD = free air delivery) |
1849 |
Reynolds number |
1850 |
Shows the Reynolds number currently calculated |
1851 |
Sound velocity |
1852 |
Shows the currently calculated sound velocity |
1853 |
Shows the currently calculated specific heat capacity |
1854 |
Shows the highest previously measured medium temperature |
1855 |
Shows the lowest previously measured medium temperature |
1856 |
Shows 2nd temperature for heat flow calculation. The temperature can be an external or fixed entered value. |
1857 |
Enter fixed value for the 2nd temperature for the heat flow calculation |
1858 |
External 2nd temperature heat flow |
1859 |
Shows the value for the external 2nd temperature for heat flow calculation |
1860 |
Input type 2nd temperature heat flow |
1861 |
Select input type for the 2nd temperature for the heat flow calculation |
1862 |
Thermal conductivity |
1863 |
Shows the currently calculated thermal conductivity |
1864 |
Select the position of the measuring device in relation to the external temperature sensor |
1865 |
Upstream |
1866 |
Downstream |
1867 |
Delete values |
1868 |
Delete previous adjustment values and descriptions |
1869 |
Confirm |
1870 |
Confirm deletion |
1871 |
Description 1 |
1872 |
Description for in-situ adjustment: e.g. facility, operator, date |
1873 |
Description 2 |
1874 |
Description 3 |
1875 |
Description 4 |
1876 |
Stability check |
1877 |
Activate stability check. New adjustment value is only accepted when the measurement is stable |
1878 |
Activate the in-situ adjustment. The points stored by the user are used for the in-situ adjustment |
1879 |
Gas description 1/2 |
1880 |
Shows the 1st part of the description of the set gas used in the in-situ adjustment |
1881 |
|
1882 |
Gas description 2/2 |
1883 |
Shows the 2nd part of the description of the set gas used in the in-situ adjustment |
1884 |
Input type reference value |
1885 |
Select input type for the reference value |
1886 |
Manual |
1887 |
InSituNumberOfPoints 1 |
1888 |
Status |
1889 |
Shows the validity of the actual reference value |
1890 |
Replaced |
1891 |
Unstable |
1892 |
Invalid |
1893 |
Flow value 1 description |
1894 |
Shows the process conditions at the time when the measured value is stored |
1895 |
Flow value 2 description |
1896 |
Flow value 11 description |
1897 |
Flow value 12 description |
1898 |
Flow value 13 description |
1899 |
Flow value 14 description |
1900 |
Flow value 15 description |
1901 |
Flow value 16 description |
1902 |
Flow value 3 description |
1903 |
Flow value 4 description |
1904 |
Flow value 5 description |
1905 |
Flow value 6 description |
1906 |
Flow value 7 description |
1907 |
Flow value 8 description |
1908 |
Flow value 9 description |
1909 |
Flow value 10 description |
1910 |
External reference value |
1911 |
Shows the external reference value for the in situ adjustment |
1912 |
Reference value |
1913 |
Enter fixed value as reference value used for the in situ adjustment |
1914 |
Actual flow value |
1915 |
Shows the actual flow in relation to the maximum, factory-measured value that is adapted to the actual process conditions |
1916 |
Flow value 1 |
1917 |
Shows the stored flow value in relation to the maximum, factory-measured value that is adapted to the actual process conditions |
1918 |
Flow value 2 |
1919 |
Flow value 11 |
1920 |
Flow value 12 |
1921 |
Flow value 13 |
1922 |
Flow value 14 |
1923 |
Flow value 15 |
1924 |
Flow value 16 |
1925 |
Flow value 3 |
1926 |
Flow value 4 |
1927 |
Flow value 5 |
1928 |
Flow value 6 |
1929 |
Flow value 7 |
1930 |
Flow value 8 |
1931 |
Flow value 9 |
1932 |
Flow value 10 |
1933 |
Apply value |
1934 |
Apply the actual value |
1935 |
Select flow reference |
1936 |
Select process variable. This process variable is used as reference value for the in situ adjustment. |
1937 |
Enter factor to compensate the mounting-related measurement error |
1938 |
InstallationType 1 |
1939 |
Flowcell |
1940 |
Insertion |
1941 |
Shows calculated insertion depth of the sensor |
1942 |
Mounting set height |
1943 |
Enter mounting set height |
1944 |
Enter the internal diameter of a circular pipe |
1945 |
Duct height |
1946 |
Enter inner duct height. Duct height and sensor shaft are parallel. |
1947 |
Select the shape of the pipe |
1948 |
Circular |
1949 |
Rectangular |
1950 |
Pipe wall thickness |
1951 |
Enter the pipe wall thickness |
1952 |
Duct width |
1953 |
Enter inner duct width. The duct width is vertical to the sensor shaft. |
1954 |
Power coefficient |
1955 |
Shows the power coefficient currently measured. The sign shows the flow direction. Plus: with flow direction, Minus: against flow direction |
1956 |
Sensitivity |
1957 |
Enter the threshold value for process stability. The higher the value, the better disturbances are detected |
1958 |
Reset min/max values |
1959 |
Select measured variable whose minimum value and maximum value are to be reset |
1960 |
SpecialGasAvailable |
1961 |
Temperature difference |
1962 |
Shows the temperature difference between temperature sensor and heating element currently measured |
1963 |
Zero point adjustment control |
1964 |
Start zero point adjustment |
1965 |
Zeropoint adjust state |
1966 |
Zero point adjust failure |
1967 |
Shows the power coefficient currently measured. |
1968 |
Resistance |
1969 |
Shows the resistance of the Pt100 currently measured |
1970 |
Status 1 |
1971 |
Shows the temperature of the Pt100 currently measured |
1972 |
Shows the temperature difference between Pt100 and reference. If the Pt100 is the reference, an invalid is shown. |
1973 |
Select process variable for totalizer |
1974 |
method_update_TIC_TotUnit_1 |
1975 |
method_update_TIC_TotUnit_2 |
1976 |
method_update_TIC_TotUnit_3 |
1977 |
Control Totalizer 1 |
1978 |
Control totalizer value |
1979 |
Totalize |
1980 |
Reset + hold |
1981 |
Preset + hold |
1982 |
Preset + totalize |
1983 |
Hold |
1984 |
Control Totalizer 2 |
1985 |
Control Totalizer 3 |
1986 |
Define totalizer behavior in alarm condition |
1987 |
Stop |
1988 |
Assign gas |
1989 |
Select the gas that the totalizer uses. This gas is only totalized when it is currently active ('Active gas' parameter) |
1990 |
Both gases |
1991 |
Totalizer overflow 1 |
1992 |
Shows the current totalizer overflow |
1993 |
Totalizer overflow 2 |
1994 |
Totalizer overflow 3 |
1995 |
Preset value 1 |
1996 |
Specify start value for totalizer |
1997 |
Preset value 2 |
1998 |
Preset value 3 |
1999 |
Totalizer operation mode |
2000 |
Select totalizer calculation mode |
2001 |
Net flow total |
2002 |
Forward flow total |
2003 |
Reverse flow total |
2004 |
Unit totalizer 1 |
2005 |
Select process variable totalizer unit |
2006 |
Unit totalizer 2 |
2007 |
Unit totalizer 3 |
2008 |
Totalizer value 1 |
2009 |
Shows the current totalizer counter value |
2010 |
Totalizer value 2 |
2011 |
Totalizer value 3 |
2012 |
Data logging control |
2013 |
Select option for data logging |
2014 |
Delete + start |
2015 |
Logging delay |
2016 |
Enter time delay for data logging |
2017 |
Read trend curves |
2018 |
Read trend channel 1 |
2019 |
Read trend channel 2 |
2020 |
Read trend channel 3 |
2021 |
Read trend channel 4 |
2022 |
Assign channel 1 |
2023 |
Assign a process variable to logging channel |
2024 |
Assign channel 2 |
2025 |
Assign channel 3 |
2026 |
Assign channel 4 |
2027 |
Entire logging duration |
2028 |
Shows the total logging duration of the data logging |
2029 |
Data logging |
2030 |
Select method of data logging |
2031 |
Overwriting |
2032 |
Not overwriting |
2033 |
MaxTrendEntries 1 |
2034 |
OperationHours 1 |
2035 |
Data logging status |
2036 |
Shows the status of the data logging |
2037 |
Delay active |
2038 |
Stopped |
2039 |
Clear logging data |
2040 |
Clear the entire logging data |
2041 |
Logging interval |
2042 |
Define the logging interval tlog for data logging. This value defines the time interval between the individual data points in the memory |
2043 |
TrendListStatus 1 |
2044 |
TrendNextListPosition 1 |
2045 |
TrendPackageSize 1 |
2046 |
Trend storage time |
2047 |
TrendSupportedPackageSize 1 |
2048 |
Read number of value |
2049 |
Version 1 |
2050 |
UniversalInputOutput_ActInstance |
2051 |
PFS output |
2052 |
Current input |
2053 |
Status input |
2054 |
Relay output |
2055 |
Configurable |
2056 |
Restart needed |
2057 |
Apply I/O configuration |
2058 |
Apply parameterization of the freely configurable I/O module |
2059 |
IsMultiModeEnabled |
2060 |
I/O module 1 type |
2061 |
Shows the I/O module type |
2062 |
Status input |
2063 |
Pulse/frequency/switch output |
2064 |
Relay output |
2065 |
I/O module 2 type |
2066 |
I/O module 3 type |
2067 |
I/O module 4 type |
2068 |
I/O module 1 information |
2069 |
Shows information of the plugged I/O module |
2070 |
Not configurable |
2071 |
HART |
2072 |
I/O module 2 information |
2073 |
I/O module 3 information |
2074 |
I/O module 4 information |
2075 |
I/O module 1 terminal numbers |
2076 |
Shows the terminal numbers used by the I/O module |
2077 |
I/O module 2 terminal numbers |
2078 |
I/O module 3 terminal numbers |
2079 |
I/O module 4 terminal numbers |
2080 |
Select antenna |
2081 |
Select internal or external antenna for reception |
2082 |
External antenna |
2083 |
Internal antenna |
2084 |
Apply changes |
2085 |
Use changed WLAN settings |
2086 |
Security identification |
2087 |
Select security settings and download these settings via menu Data management > Security > WLAN |
2088 |
Trusted issuer certificate |
2089 |
Device certificate |
2090 |
Device private key |
2091 |
Enable Broadcast SSID |
2092 |
WLAN |
2093 |
Activate or deactivate WLAN |
2094 |
WLAN IP address |
2095 |
Enter IP address of the WLAN interface of the device |
2096 |
IP address domain name server |
2097 |
Enter the IP address of the domain name server |
2098 |
Gateway IP address |
2099 |
Enter the IP address of the gateway |
2100 |
Connection state |
2101 |
Shows the current connection state |
2102 |
Connected |
2103 |
Not connected |
2104 |
WLAN availble |
2105 |
WLAN MAC address |
2106 |
Enter MAC address of the WLAN interface of the device |
2107 |
FF-FF-FF-FF-FF-FF |
2108 |
WLAN mode |
2109 |
Select WLAN mode |
2110 |
WLAN access point |
2111 |
WLAN Client |
2112 |
SSID name |
2113 |
Enter the user-defined SSID name (max. 32 characters) |
2114 |
2.4 GHz WLAN channel |
2115 |
Shows WLAN channel |
2116 |
WLAN password |
2117 |
Enter WLAN password |
2118 |
Received signal strength |
2119 |
Shows the received signal strength |
2120 |
Medium |
2121 |
Network security |
2122 |
Select the security type of the WLAN network |
2123 |
Unsecured |
2124 |
WPA2-PSK |
2125 |
EAP-PEAP with MSCHAPv2 |
2126 |
EAP-PEAP MSCHAPv2 no server authentic. |
2127 |
EAP-TLS |
2128 |
WLAN passphrase |
2129 |
Enter the network key (8 to 32 characters) |
2130 |
Assign SSID name |
2131 |
Select which name will be used for SSID: device tag or user-defined name |
2132 |
WLAN subnet mask |
2133 |
Enter subnet mask of the WLAN interface of the device |
2134 |
User name |
2135 |
Enter user name |
2136 |
WLANPassphraseVisibile 1 |
2137 |
Remedy information |
2138 |
Actual remedy information |
2139 |
Remedy information 1 |
2140 |
Remedy information 2 |
2141 |
Remedy information 3 |
2142 |
Remedy information 4 |
2143 |
Remedy information 5 |
2144 |
Previous remedy information |
2145 |
Edit: Reset all totalizers |
2146 |
Edit: Configuration management |
2147 |
Edit: Start verification |
2148 |
Edit: Code incorrect |
2149 |
Edit: Device reset |
2150 |
Edit: Clear event list |
2151 |
Edit: Zero point adjustment control |
2152 |
Edit: Clear logging data |
2153 |
Edit: Apply I/O configuration |
2154 |
STD_SWOptionEnabledOverview_1 |
2155 |
Response_Code_msg |
2156 |
BCT_request |
2157 |
Blocktransfer DWORD(4)_1 |
2158 |
Blocktransfer DWORD(4)_2 |
2159 |
Blocktransfer DWORD(4)_3 |
2160 |
Blocktransfer DWORD(4)_4 |
2161 |
Blocktransfer DWORD(4)_5 |
2162 |
Blocktransfer DWORD(4)_6 |
2163 |
Blocktransfer DWORD(4)_7 |
2164 |
Blocktransfer DWORD(4)_8 |
2165 |
Blocktransfer DWORD(4)_9 |
2166 |
Blocktransfer DWORD(4)_10 |
2167 |
Blocktransfer DWORD(4)_11 |
2168 |
Blocktransfer DWORD(4)_12 |
2169 |
Blocktransfer DWORD(4)_13 |
2170 |
Blocktransfer DWORD(4)_14 |
2171 |
Blocktransfer DWORD(4)_15 |
2172 |
Blocktransfer DWORD(4)_16 |
2173 |
Blocktransfer DWORD(4)_17 |
2174 |
Blocktransfer DWORD(4)_18 |
2175 |
Blocktransfer DWORD(4)_19 |
2176 |
Blocktransfer DWORD(4)_20 |
2177 |
Blocktransfer DWORD(4)_21 |
2178 |
Blocktransfer DWORD(4)_22 |
2179 |
Blocktransfer DWORD(4)_23 |
2180 |
Blocktransfer DWORD(4)_24 |
2181 |
Blocktransfer DWORD(4)_25 |
2182 |
CorrGain |
2183 |
CorrOffset |
2184 |
DomainNameLength |
2185 |
DomainName |
2186 |
Display |
2187 |
HARTOutput |
2188 |
Data logging |
2189 |
Pulse/frequency/switch output 1 |
2190 |
Pulse/frequency/switch output 2 |
2191 |
Pulse/frequency/switch output 3 |
2192 |
Endress+Hauser |
2193 |
Process |
2194 |
HeartbeatResultsThermalFlowMeter |
2195 |
Diagnostics |
2196 |
Device |
2197 |
HARTInput |
2198 |
CDI Ethernet |
2199 |
Status input 1 |
2200 |
Status input 2 |
2201 |
Status input 3 |
2202 |
HARTBurstMessage |
2203 |
Heartbeat |
2204 |
Relay output 1 |
2205 |
Relay output 2 |
2206 |
Relay output 3 |
2207 |
I/O module 1 |
2208 |
I/O module 2 |
2209 |
I/O module 3 |
2210 |
I/O module 4 |
2211 |
FluidHandler |
2212 |
ThermalFlowMeter |
2213 |
14.730 Psi, 60 °F |
2214 |
Sulfur dioxide SO2 |
2215 |
Vinyl chloride C2H3Cl |
2216 |
Nitrous oxide N2O |
2217 |
Others |
2218 |
port |
2219 |
Sensor number |
2220 |
Sensor 1 |
2221 |
Sensor 2 |
2222 |
Curve ID |
2223 |
Data transfer finished |
2224 |
X minimum value |
2225 |
X maximum value |
2226 |
X decimation value |
2227 |
Preparation status |
2228 |
X engineering unit |
2229 |
UNITS_CODE(45) |
2230 |
Y engineering unit |
2231 |
Transmission length |
2232 |
Number of data points |
2233 |
Compression state |
2234 |
success |
2235 |
inefficient (nur geräteintern) |
2236 |
Dst2Small |
2237 |
WrIntoRd |
2238 |
Fail (schwerer interner Fehler) |
2239 |
Corrected Xmin |
2240 |
Device corrected starting point in engineering unit |
2241 |
Corrected Xmax |
2242 |
Device corrected ending point in engineering unit |
2243 |
function_code |
2244 |
Master Byte Count |
2245 |
Device Byte Count |
2246 |
Segment Length Changed |
2247 |
Port not Found |
2248 |
Port in Use |
2249 |
Maximum Ports In Use |
2250 |
Segment Length Too Small |
2251 |
Blocktransfer Float_1 |
2252 |
Blocktransfer Float_2 |
2253 |
Blocktransfer Float_3 |
2254 |
Blocktransfer Float_4 |
2255 |
Blocktransfer Float_5 |
2256 |
Blocktransfer Float_6 |
2257 |
Blocktransfer Float_7 |
2258 |
Blocktransfer Float_8 |
2259 |
Blocktransfer Float_9 |
2260 |
Blocktransfer Float_10 |
2261 |
Blocktransfer Float_11 |
2262 |
Blocktransfer Float_12 |
2263 |
Blocktransfer Float_13 |
2264 |
Blocktransfer Float_14 |
2265 |
Blocktransfer Float_15 |
2266 |
Blocktransfer Float_16 |
2267 |
number_bytes_message |
2268 |
Port not Open |
2269 |
Close port |
2270 |
End of transfer |
2271 |
Progress |
2272 |
Device Settings |
2273 |
Maintenance |
2274 |
Feature not supported |
2275 |
Offline |
2276 |
Diagnostics |
2277 |
Header |
2278 |
Administration |
2279 |
Advanced setup |
2280 |
Application |
2281 |
Calibration |
2282 |
Logbook |
2283 |
Web server |
2284 |
Pt100 1 |
2285 |
Pt100 2 |
2286 |
Pt100 3 |
2287 |
Communication |
2288 |
Configuration backup |
2289 |
Device information |
2290 |
Diagnostic configuration |
2291 |
Diagnostic list |
2292 |
Diagnostics |
2293 |
Operation |
2294 |
Diagnostic behavior |
2295 |
Diagnostic handling |
2296 |
Event logbook |
2297 |
Expert |
2298 |
External compensation |
2299 |
Gas properties |
2300 |
Measurement mode |
2301 |
Burst configuration |
2302 |
Burst configuration 1 |
2303 |
Burst configuration 2 |
2304 |
Burst configuration 3 |
2305 |
Configuration |
2306 |
Information |
2307 |
Input |
2308 |
HART output |
2309 |
Output |
2310 |
Heartbeat Technology |
2311 |
Heartbeat base settings |
2312 |
Performing verification |
2313 |
Heartbeat setup |
2314 |
Verification results |
2315 |
Input values |
2316 |
In-situ adjustment |
2317 |
Adjustment values in use |
2318 |
Inventory counter |
2319 |
Main electronic temperature |
2320 |
Medium temperature |
2321 |
Min/max values |
2322 |
Display module |
2323 |
Main electronic module + I/O module 1 |
2324 |
Sensor module |
2325 |
Totalizer handling |
2326 |
Process parameters |
2327 |
Process variables |
2328 |
Relay output 1 |
2329 |
Relay output 2 |
2330 |
Relay output 3 |
2331 |
Sensor adjustment |
2332 |
Setup |
2333 |
Simulation |
2334 |
Value status input 1 |
2335 |
Value status input 2 |
2336 |
Value status input 3 |
2337 |
System |
2338 |
System units |
2339 |
System values |
2340 |
Totalizer |
2341 |
I/O configuration |
2342 |
WLAN settings |
2343 |
Additional settings |
2344 |
Current output 1-1 |
2345 |
Current output 2-1 |
2346 |
Current output 3-1 |
2347 |
Current output 4-1 |
2348 |
Current output 1-2 |
2349 |
Current output 2-2 |
2350 |
Current output 3-2 |
2351 |
Current output 4-2 |
2352 |
Current output 1-3 |
2353 |
Current output 2-3 |
2354 |
Current output 3-3 |
2355 |
Current output 4-3 |
2356 |
Extended order code |
2357 |
Device information 1 |
2358 |
Display 1 |
2359 |
Display 2 |
2360 |
Burst message 1 |
2361 |
Burst message 2 |
2362 |
Burst message 3 |
2363 |
Device information 2 |
2364 |
HART info |
2365 |
Settings |
2366 |
Sensor module |
2367 |
Process value simulation |
2368 |
Output simulation |
2369 |
Input simulation |
2370 |
Alteration code |
2371 |
Input/output 1 |
2372 |
Input/output 2 |
2373 |
Input/output 3 |
2374 |
Input/output 4 |
2375 |
Deactivate SIL |
2376 |
abort_Window_SILSequence_SequenceMethod_1 |
2377 |
abort_HH_SILSequence_SequenceMethod_1 |
2378 |
Upload variables |
2379 |
Instrument health status |
2380 |
Line recorder PV / SV |
2381 |
Measured values |
2382 |
Line recorder TV / QV |
2383 |
Bargraph |
2384 |
Line recorder |
2385 |
HART Diagnostics |
2386 |
Extended Device Status |
2387 |
Device standardized status 0 |
2388 |
Device Status |
2389 |
Status Byte 0 |
2390 |
Status Byte 1 |
2391 |
Status Byte 2 |
2392 |
Status Byte 3 |
2393 |
Status Byte 4 |
2394 |
Status Byte 5 |
2395 |
Status Byte 14 |
2396 |
Status Byte 15 |
2397 |
Status Byte 16 |
2398 |
Status Byte 17 |
2399 |
Status Byte 18 |
2400 |
Status Byte 19 |
2401 |
Status Byte 21 |
2402 |
Status Byte 22 |
2403 |
Status Byte 23 |
2404 |
Hart diagnosis |
2405 |
HartLogo |
2406 |
Configuration Flag Reset |
2407 |
Commands reset the configuration flag. |
2408 |
Failure |
2409 |
Out of Specification |
2410 |
Function Check |
2411 |
C431 Trim X
Remedy information
Carry out trim |
2412 |
C491 Current output X simulation
Remedy information
Deactivate simulation |
2413 |
C485 Measured variable simulation -> Remedy information: Deactivate simulation |
2414 |
976 Mass flow out of calibrated range -> Remedy information: 1. Check process cond. 2. Increase system pressure |
2415 |
C453 Flow override -> Remedy information: Deactivate flow override |
2416 |
842 Process limit -> Remedy information: Low flow cut off active! 1. Check low flow cut off configuration |
2417 |
F382 Data storage -> Remedy information: 1. Insert T-DAT 2. Replace T-DAT |
2418 |
F083 Memory content -> Remedy information: 1. Restart device 2. Restore HistoROM S-DAT backup ('Device reset' parameter) 3. Replace HistoROM S-DAT |
2419 |
F242 Software incompatible -> Remedy information: 1. Check software 2. Flash or change main electronics module |
2420 |
F262 Sensor electronic connection faulty -> Remedy information: 1. Check/replace connection cable between sensor electronic module (ISEM) and main electr. 2. Check/replace module cartridge, ISEM, main electr. |
2421 |
F437 Configuration incompatible -> Remedy information: Restart device |
2422 |
M438 Dataset -> Remedy information: 1. Check data set file 2. Check device configuration 3. Up- and download new configuration |
2423 |
C484 Failure mode simulation -> Remedy information: Deactivate simulation |
2424 |
F803 Current loop -> Remedy information: 1. Check wiring 2. Change I/O module |
2425 |
F276 I/O module X faulty
Remedy information
1. Restart device
2. Change I/O module |
2426 |
M311 Electronic failure -> Remedy information: 1. Do not reset device 2. Contact service |
2427 |
F410 Data transfer -> Remedy information: 1. Check connection 2. Retry data transfer |
2428 |
F273 Main electronic failure -> Remedy information: Change electronic |
2429 |
F275 I/O module X defective
Remedy information
Change I/O module |
2430 |
441 Current output X
Remedy information
1. Check process
2. Check current output settings |
2431 |
442 Frequency output X
Remedy information
1. Check process
2. Check frequency output settings |
2432 |
443 Pulse output X
Remedy information
1. Check process
2. Check pulse output settings |
2433 |
C492 Simulation frequency output X
Remedy information
Deactivate simulation frequency output |
2434 |
C493 Pulse output X simulation active
Remedy information
Deactivate pulse output simulation |
2435 |
C494 Switch output simulation X
Remedy information
Deactivate simulation switch output |
2436 |
C495 Diagnostic event simulation -> Remedy information: Deactivate simulation |
2437 |
F882 Input signal -> Remedy information: 1. Check input configuration 2. Check external device or process conditions |
2438 |
C486 Current input X simulation
Remedy information
Deactivate simulation |
2439 |
444 Current input X
Remedy information
1. Check process
2. Check current input settings |
2440 |
F082 Data storage -> Remedy information: 1. Check module connections 2. Change electronic modules |
2441 |
C412 Processing download -> Remedy information: Download active, please wait |
2442 |
832 Electronic temperature too high -> Remedy information: Reduce ambient temperature |
2443 |
833 Electronic temperature too low -> Remedy information: Increase ambient temperature |
2444 |
834 Process temperature too high -> Remedy information: Reduce process temperature |
2445 |
835 Process temperature too low -> Remedy information: Increase process temperature |
2446 |
979 Unstable process conditions -> Remedy information: 1. Check process cond. 2. Increase system pressure |
2447 |
977 Reverse flow detected -> Remedy information: Check flow direction |
2448 |
F252 Modules incompatible -> Remedy information: 1. Check electronic modules 2. Check if correct modules are available (e.g. NEx, Ex) 3. Replace electronic modules |
2449 |
F270 Main electronic failure -> Remedy information: Change main electronic module |
2450 |
F271 Main electronic failure -> Remedy information: 1. Restart device 2. Change main electronic module |
2451 |
F272 Main electronic failure -> Remedy information: Restart device |
2452 |
F201 Device failure -> Remedy information: Restart device |
2453 |
F004 Sensor error -> Remedy information: Change sensor |
2454 |
S941 Flow velocity too high -> Remedy information: 1. Check process cond. 2. Increase system pressure |
2455 |
S961 Delta temperature -> Remedy information: Check flow rate |
2456 |
144 Sensor drift -> Remedy information: 1. Check sensor 2. Replace sensor |
2457 |
F283 Memory content -> Remedy information: Reset device |
2458 |
F383 Memory content -> Remedy information: 1. Restart device 2. Delete T-DAT via 'Reset device' parameter 3. Replace T-DAT |
2459 |
F537 Configuration -> Remedy information: 1. Check IP addresses in network 2. Change IP address |
2460 |
C302 Device verification in progress -> Remedy information: Device verification active, please wait. |
2461 |
F375 I/O-X communication failed
Remedy information
1. Restart device
2. Check if failure recurs
3. Replace module rack inclusive electronic modules |
2462 |
S539 Flow computer configuration incorrect -> Remedy information: 1. Check input value (pressure, temperature) 2. Check allowed values of the medium properties |
2463 |
F281 Electronic initialization -> Remedy information: Firmware update active, please wait! |
2464 |
F378 Supply voltage ISEM faulty -> Remedy information: Check supply voltage to the ISEM |
2465 |
M303 I/O X configuration changed
Remedy information
1. Apply I/O module configuration (parameter 'Apply I/O configuration')
2. Afterwards reload device description and check wiring |
2466 |
F332 Writing in HistoROM backup failed -> Remedy information: Replace user interface board Ex d/XP: replace transmitter |
2467 |
F520 I/O X hardware configuration invalid
Remedy information
1. Check I/O hardware configuration
2. Replace wrong I/O module
3. Plug the module of double pulse output on correct slot |
2468 |
C594 Relay output simulation -> Remedy information: Deactivate simulation switch output |
2469 |
F387 HistoROM data faulty -> Remedy information: Contact service organization |
2470 |
F331 Firmware update failed -> Remedy information: 1. Update firmware of device 2. Restart device |
2471 |
M330 Flash file invalid -> Remedy information: 1. Update firmware of device 2. Restart device |
2472 |
F372 Sensor electronic (ISEM) faulty -> Remedy information: 1. Restart device 2. Check if failure recurs 3. Replace sensor electronic module (ISEM) |
2473 |
F373 Sensor electronic (ISEM) faulty -> Remedy information: Transfer data or reset device |
2474 |
F361 I/O module X faulty
Remedy information
1. Restart device
2. Check electronic modules
3. Change I/O Modul or main electronics |
2475 |
C496 Status input simulation -> Remedy information: Deactivate simulation status input |
2476 |
Update Time Period |
2477 |
LOW RANGE VALUE (dummy) |
2478 |
UP RANGE VALUE (dummy) |
2479 |
MIN SPAN VALUE (dummy) |
2480 |
Device family |
2481 |
Classification |
2482 |
Device family status |
2483 |
Process data quality |
2484 |
Limit status |
2485 |
Lower trim |
2486 |
Upper trim |
2487 |
Trim support |
2488 |
Level Min lower trim |
2489 |
Level Max lower trim |
2490 |
Level Min upper trim |
2491 |
Level Max upper trim |
2492 |
Level Min trim diff |
2493 |
Dummy |
2494 |
Update Period |
2495 |
0x80 |
2496 |
0x04 |
2497 |
0x84 |
2498 |
0x01 |
2499 |
0x81 |
2500 |
0x08 |
2501 |
0x88 |
2502 |
0x02 |
2503 |
0x82 |
2504 |
0x10 |
2505 |
0x20 |
2506 |
0xA0 |
2507 |
Event buffer selection |
2508 |
Event buffer selection : 1-10 |
2509 |
Event buffer selection : 11-20 |
2510 |
Event buffer selection : 21-30 |
2511 |
Event buffer selection : 31-40 |
2512 |
Event buffer selection : 41-50 |
2513 |
Event buffer selection : 51-60 |
2514 |
Event buffer selection : 61-70 |
2515 |
Event buffer selection : 71-80 |
2516 |
Event buffer selection : 81-90 |
2517 |
Event buffer selection : 91-100 |
2518 |
Read events |
2519 |
Event list |
2520 |
Status signal + Remedy information |
2521 |
Event |
2522 |
No Event |
2523 |
View trend |
2524 |
Displayed selected curves. |
2525 |
Maximum |
2526 |
Minimum |
2527 |
Y Max: |
2528 |
Y Min: |
2529 |
Unit |
2530 |
W |
2531 |
Pa a |
2532 |
Pa |
2533 |
Loop Warning Variables |
2534 |
Loop Warning Variables- Variables that display a warning message before new values are sent. |
2535 |
PV Analog Channel Saturated |
2536 |
PV Analog Channel Fixed |
2537 |
Wireless |
2538 |
WirelessHART Device |
2539 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
2540 |
Primary |
2541 |
Primary Analog Channel |
2542 |
Secondary |
2543 |
Secondary Analog Channel |
2544 |
Tertiary |
2545 |
Tertiary Analog Channel |
2546 |
Quaternary |
2547 |
Quaternary Analog Channel |
2548 |
Quinary |
2549 |
Quinary Analog Channel |
2550 |
Critical Power Failure |
2551 |
Lock all |
2552 |
Trim not supported |
2553 |
Configuration cannot be changed |
2554 |
Locked by gateway |
2555 |
Analog Input Channel |
2556 |
Analog Output Channel |
2557 |
Secondary Analog Channel Saturated |
2558 |
Tertiary Analog Channel Saturated |
2559 |
Quaternary Analog Channel Saturated |
2560 |
Quinary Analog Channel Saturated |
2561 |
Secondary Analog Channel Fixed |
2562 |
Tertiary Analog Channel Fixed |
2563 |
Quaternary Analog Channel Fixed |
2564 |
Quinary Analog Channel Fixed |
2565 |
Simulation active |
2566 |
The device is in simulation mode and the level output is not representative of the process. |
2567 |
Non-Volatile memory failure |
2568 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
2569 |
Volatile memory error |
2570 |
The RAM memory check is invalid or maybe corrupt |
2571 |
Watchdog reset executed |
2572 |
A watchdog reset has been performed |
2573 |
Voltage conditions out of range |
2574 |
A voltage condition is outside its allowable range |
2575 |
Environmental conditions out of range |
2576 |
An internal or environmental condition is beyond acceptable limits. |
2577 |
Electronic failure |
2578 |
A hardware problem not related to the sensor has been detected. |
2579 |
Subdevice list changed |
2580 |
Duplicate master detected |
2581 |
Capacity Denied |
2582 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
2583 |
Bandwidth allocation pending |
2584 |
Block transfer pending |
2585 |
Battery life |
2586 |
Percent range |
2587 |
Loop current |
2588 |
Primary variable |
2589 |
Secondary variable |
2590 |
Tertiary variable |
2591 |
Quaternary variable |
2592 |
Read receive time |
2593 |
Write date and time |
2594 |
Non-Volatile Clock |
2595 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
2596 |
Clock Uninitialized |
2597 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
2598 |
No restrictions |
2599 |
SI Only |
2600 |
Restricted to SI Unit codes only |
2601 |
Process automation device |
2602 |
Discrete device |
2603 |
Hybrid:Process automation+discrete |
2604 |
I/O System |
2605 |
WirelessHART Process automation device |
2606 |
WirelessHART Discrete device |
2607 |
WirelessHART Process automation+discrete |
2608 |
WirelessHART Gateway |
2609 |
WirelessHART Access point |
2610 |
WirelessHART Process adapter |
2611 |
WirelessHART Discrete adapter |
2612 |
WirelessHART enabled handheld/portable maintenance tool |
2613 |
Device Profile |
2614 |
US |
2615 |
United States of America |
2616 |
JP |
2617 |
Japan |
2618 |
DE |
2619 |
Germany |
2620 |
FR |
2621 |
France |
2622 |
ES |
2623 |
Spain |
2624 |
RU |
2625 |
Russian Federation |
2626 |
CN |
2627 |
People's Republic of China |
2628 |
Secondary Master |
2629 |
Primary Master |
2630 |
Device Diagnostic Status 0 |
2631 |
Device Diagnostic Status 1 |
2632 |
I/O and Subdevice Status |
2633 |
WirelessHART Status |
2634 |
Time Set Option |
2635 |
Real Time Clock Flags |
2636 |
Country |
2637 |
Country of intended device installation |
2638 |
SI Unit Control |
2639 |
Indicates if device should only display SI unit codes |
2640 |
Burst Trigger Units |
2641 |
Enable on token-passing data link layer only |
2642 |
Enable on TDMA data link layer only |
2643 |
Enable on both TDMA and token-passing data link layer |
2644 |
Burst Trigger Class |
2645 |
Continuous |
2646 |
The Burst Message is published continuously at (worst case) the Minimum Update Period. |
2647 |
Window |
2648 |
The Burst Message is triggered when the source value deviates more than the specified trigger value |
2649 |
Rising |
2650 |
The Burst Message is triggered when source value Rises Above the specified trigger value. |
2651 |
Falling |
2652 |
The Burst Message is triggered when the source value Falls Below the specified trigger value. |
2653 |
On-change |
2654 |
The Burst Message is triggered when any value in the message changes. |
2655 |
Off |
2656 |
Enable event notification on token-passing data link layer |
2657 |
Enable event notification on TDMA data link layer |
2658 |
Enable event notification on TDMA and token-passing data link layer |
2659 |
Configuration changed event pending |
2660 |
Device status event pending |
2661 |
More status available event pending |
2662 |
Wired HART Enabled |
2663 |
Enabled on Wired HART device connection only |
2664 |
Wireless HART Enabled |
2665 |
Enabled on WirelessHART device connection only |
2666 |
Both Wired and WirelessHart Enabled |
2667 |
Enabled on both Wired and WirelessHART connections |
2668 |
Burst Msg Trigger Mode |
2669 |
Event Status |
2670 |
Event Notification Control |
2671 |
Device Status Mask |
2672 |
Ext dev status Mask |
2673 |
Device Diagnostic Status 0 Mask |
2674 |
Device Diagnostic Status 1 Mask |
2675 |
Device Diagnostic Status 2 Mask |
2676 |
Device Diagnostic Status 3 Mask |
2677 |
AO saturated Mask |
2678 |
AO fixed Mask |
2679 |
Latched Device Status |
2680 |
Operate mode Mask |
2681 |
Not Defined |
2682 |
Latched Ext dev status |
2683 |
Latched Device Diagnostic Status 0 |
2684 |
Latched Device Diagnostic Status 1 |
2685 |
Latched Device Diagnostic Status 2 |
2686 |
Latched Device Diagnostic Status 3 |
2687 |
Latched AO saturated |
2688 |
Latched AO fixed |
2689 |
Latched Operate Mode |
2690 |
Time Stamp |
2691 |
Relative time value on network |
2692 |
8u |
2693 |
Dynamic Variables Returned for Device Variables |
2694 |
Command Response Truncated |
2695 |
Configuration Change Counter Mismatch |
2696 |
Status bytes mismatch |
2697 |
count |
2698 |
Device Variable |
2699 |
Variable to trim |
2700 |
8.3f |
2701 |
7d |
2702 |
Actual diagnostics |
2703 |
: %{SPV_CurrentSysConditionUnion_1} |
2704 |
Carry out trim
(Service ID: 4) |
2705 |
1. Check input configuration
2. Check external device or process conditions
(Service ID: 49) |
2706 |
Firmware update active, please wait!
(Service ID: 60) |
2707 |
Restart device
(Service ID: 96) |
2708 |
1. Check software
2. Flash or change main electronics module
(Service ID: 103) |
2709 |
1. Check data set file
2. Check device configuration
3. Up- and download new configuration
(Service ID: 106) |
2710 |
1. Check electronic modules
2. Check if correct modules are available (e.g. NEx, Ex)
3. Replace electronic modules
(Service ID: 107) |
2711 |
Change main electronic module
(Service ID: 120) |
2712 |
Restart device
(Service ID: 121) |
2713 |
Change I/O module
(Service ID: 122) |
2714 |
1. Restart device
2. Change I/O module
(Service ID: 123) |
2715 |
Change main electronic module
(Service ID: 124) |
2716 |
1. Restart device
2. Change main electronic module
(Service ID: 125) |
2717 |
Change main electronic module
(Service ID: 127) |
2718 |
Change main electronic module
(Service ID: 128) |
2719 |
1. Restart device
2. Change I/O module
(Service ID: 129) |
2720 |
Change main electronic module
(Service ID: 132) |
2721 |
1. Check process
2. Check frequency output settings
(Service ID: 138) |
2722 |
1. Check connection
2. Retry data transfer
(Service ID: 139) |
2723 |
1. Check process
2. Check pulse output settings
(Service ID: 140) |
2724 |
Deactivate simulation frequency output
(Service ID: 141) |
2725 |
Deactivate pulse output simulation
(Service ID: 142) |
2726 |
Deactivate simulation switch output
(Service ID: 143) |
2727 |
Low flow cut off active!
1. Check low flow cut off configuration
(Service ID: 145) |
2728 |
Deactivate flow override
(Service ID: 148) |
2729 |
1. Restart device
2. Check electronic modules
3. Change I/O Modul or main electronics
(Service ID: 149) |
2730 |
Change electronic
(Service ID: 152) |
2731 |
1. Check process
2. Check current output settings
(Service ID: 153) |
2732 |
Change main electronic module
(Service ID: 159) |
2733 |
1. Restart device
2. Restore HistoROM S-DAT backup ('Device reset' parameter)
3. Replace HistoROM S-DAT
(Service ID: 160) |
2734 |
1. Check wiring
2. Change I/O module
(Service ID: 173) |
2735 |
1. Check process
2. Check current output settings
(Service ID: 182) |
2736 |
Increase ambient temperature
(Service ID: 193) |
2737 |
Reduce ambient temperature
(Service ID: 195) |
2738 |
Reduce process temperature
(Service ID: 197) |
2739 |
Increase process temperature
(Service ID: 198) |
2740 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 212) |
2741 |
Reset device
(Service ID: 225) |
2742 |
1. Do not reset device
2. Contact service
(Service ID: 226) |
2743 |
Change electronic
(Service ID: 229) |
2744 |
1. Check module connections
2. Change electronic modules
(Service ID: 231) |
2745 |
1. Restart device
2. Check if failure recurs
3. Replace module rack inclusive electronic modules
(Service ID: 263) |
2746 |
Change electronic
(Service ID: 267) |
2747 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 281) |
2748 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 288) |
2749 |
1. Check process
2. Check pulse output settings
(Service ID: 289) |
2750 |
1. Check process
2. Check frequency output settings
(Service ID: 290) |
2751 |
1. Check/replace connection cable between sensor electronic module (ISEM) and main electr.
2. Check/replace module cartridge, ISEM, main electr.
(Service ID: 329) |
2752 |
1. Check IP addresses in network 2. Change IP address
(Service ID: 330) |
2753 |
Restart device
(Service ID: 331) |
2754 |
Check flow rate
(Service ID: 332) |
2755 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 362) |
2756 |
1. Insert T-DAT
2. Replace T-DAT
(Service ID: 365) |
2757 |
1. Restart device
2. Delete T-DAT via 'Reset device' parameter
3. Replace T-DAT
(Service ID: 366) |
2758 |
Restart device
(Service ID: 367) |
2759 |
Deactivate simulation status input
(Service ID: 368) |
2760 |
1. Check input value (pressure, temperature)
2. Check allowed values of the medium properties
(Service ID: 485) |
2761 |
1. Check input value (pressure, temperature)
2. Check allowed values of the medium properties
(Service ID: 486) |
2762 |
1. Check process
2. Check current input settings
(Service ID: 491) |
2763 |
Device verification active, please wait.
(Service ID: 494) |
2764 |
Download active, please wait
(Service ID: 516) |
2765 |
1. Apply I/O module configuration (parameter 'Apply I/O configuration')
2. Afterwards reload device description and check wiring
(Service ID: 620) |
2766 |
1. Check I/O hardware configuration
2. Replace wrong I/O module
3. Plug the module of double pulse output on correct slot
(Service ID: 630) |
2767 |
Contact service organization
(Service ID: 648) |
2768 |
Deactivate simulation switch output
(Service ID: 698) |
2769 |
1. Check if correct electronic modul is plugged
2. Replace electronic module
(Service ID: 704) |
2770 |
Replace user interface board
Ex d/XP: replace transmitter
(Service ID: 711) |
2771 |
1. Update firmware of device
2. Restart device
(Service ID: 713) |
2772 |
1. Update firmware of device
2. Restart device
(Service ID: 714) |
2773 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 715) |
2774 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 716) |
2775 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 717) |
2776 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 718) |
2777 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 719) |
2778 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 720) |
2779 |
Transfer data or reset device
(Service ID: 721) |
2780 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 722) |
2781 |
Increase ambient temperature
(Service ID: 723) |
2782 |
Reduce ambient temperature
(Service ID: 724) |
2783 |
Change main electronic module
(Service ID: 727) |
2784 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 991) |
2785 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 992) |
2786 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 993) |
2787 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 994) |
2788 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 995) |
2789 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 996) |
2790 |
1. Restart device
2. Check if failure recurs
3. Replace sensor electronic module (ISEM)
(Service ID: 997) |
2791 |
1. Check process cond.
2. Increase system pressure
(Service ID: 1001) |
2792 |
1. Check sensor
2. Replace sensor
(Service ID: 1002) |
2793 |
1. Check sensor
2. Replace sensor
(Service ID: 1003) |
2794 |
Change sensor
(Service ID: 1004) |
2795 |
Change sensor
(Service ID: 1005) |
2796 |
Change sensor
(Service ID: 1006) |
2797 |
Check supply voltage to the ISEM
(Service ID: 1008) |
2798 |
1. Check process cond.
2. Increase system pressure
(Service ID: 1019) |
2799 |
Check flow direction
(Service ID: 1081) |
2800 |
1. Check process cond.
2. Increase system pressure
(Service ID: 1097) |
2801 |
- |
2802 |
Deactivate simulation |
2803 |
Reset all totalizers |
2804 |
Configuration management |
2805 |
Start verification |
2806 |
Code incorrect |
2807 |
Set write protection |
2808 |
Reset write protection |
2809 |
Device reset |
2810 |
Clear event list |
2811 |
Zero point adjustment control |
2812 |
Clear logging data |
2813 |
Apply I/O configuration |
2814 |
Define access code |
2815 |
Confirm access code |
2816 |
SIL preparation |
2817 |
: %{SIL_Prepare_1} |
2818 |
Parameter error |
2819 |
: %{SIL_BadPreconditions_1} |
2820 |
Character test string |
2821 |
: %{SIL_CharacterTestString_1} |
2822 |
SIL confirmation |
2823 |
: %{SIL_ConfirmCharacterTest_1} |
2824 |
Installation direction |
2825 |
: %{SIL_ReadBackInstallationDirection_1} |
2826 |
: %{SIL_ConfirmInstallationDirection_1} |
2827 |
: %{SIL_ReadBackCOOperatingMode_1} |
2828 |
: %{SIL_ConfirmCOOperatingMode_1} |
2829 |
Output mode |
2830 |
: %{SIL_ReadbackCOOutSignalMode_1} |
2831 |
: %{SIL_ConfirmOutSignalMode_1} |
2832 |
: %{SIL_ReadBackCOInput04mA_1} |
2833 |
: %{SIL_ConfirmCOInput04mA_1} |
2834 |
: %{SIL_ReadBackCOInput20mA_1} |
2835 |
: %{SIL_ConfirmCOInput20mA_1} |
2836 |
Damping |
2837 |
: %{SIL_ReadBackCOTauDamping_1} |
2838 |
: %{SIL_ConfirmCOTauDamping_1} |
2839 |
Failure mode |
2840 |
: %{SIL_ReadBackCOFailsafeMode_1} |
2841 |
: %{SIL_ConfirmCOFailsafeMode_1} |
2842 |
Select gas type |
2843 |
: %{SIL_ReadBackFluidSelectorGas_1} |
2844 |
: %{SIL_ConfirmFluidSelectorGas_1} |
2845 |
Gas type |
2846 |
: %{SIL_ReadBackFLHSingleGasSelector_1} |
2847 |
: %{SIL_ConfirmSingleGasSelector_1} |
2848 |
Gas mixture |
2849 |
: %{SIL_ReadbackFLHGasMixture_1} |
2850 |
: %{SIL_ConfirmGasMixture_1} |
2851 |
: %{SIL_ReadBackFLHMolPercentN2_1} |
2852 |
: %{SIL_ConfirmMolPercentN2_1} |
2853 |
: %{SIL_ReadBackFLHMolPercentC2H6_1} |
2854 |
: %{SIL_ConfirmMolPercentC2H6_1} |
2855 |
: %{SIL_ReadBackFLHMolPercentCH4_1} |
2856 |
: %{SIL_ConfirmMolPercentCH4_1} |
2857 |
: %{SIL_ReadBackFLHMolPercentCO2_1} |
2858 |
: %{SIL_ConfirmMolPercentCO2_1} |
2859 |
Pipe inner diameter |
2860 |
: %{SIL_ReadBackTFMPipeInsDiamInternal_1} |
2861 |
: %{SIL_ConfirmTFMPipeInsDiamInternal_1} |
2862 |
Insertion depth |
2863 |
: %{SIL_ReadBackTFMPipeInsertionDepth_1} |
2864 |
: %{SIL_ConfirmTFMPipeInsertionDepth_1} |
2865 |
Assign low flow cutoff |
2866 |
: %{SIL_ReadBackFlowMonitoringSelector_1} |
2867 |
: %{SIL_ConfirmFlowMonitoringSelector_1} |
2868 |
On value low flow cutoff |
2869 |
: %{SIL_ReadBackLowFlowLimit_1} |
2870 |
: %{SIL_ConfirmLowFlowLimit_1} |
2871 |
Off value low flow cutoff |
2872 |
: %{SIL_ReadBackLowFlowHisteresys_1} |
2873 |
: %{SIL_ConfirmLowFlowHisteresys_1} |
2874 |
Pressure value |
2875 |
: %{SIL_ReadBackFixPressure_1} |
2876 |
: %{SIL_ConfirmFixPressure_1} |
2877 |
End of sequence |
2878 |
Locking status |
2879 |
Execute Configuration Flag Reset? |
2880 |
Preparation in progress,
please wait! |
2881 |
Prepare busy |
2882 |
%{SPV_FilterOptions_1} : |
2883 |
No Event |
2884 |
Event buffer selection |
2885 |
%{0}% |
2886 |
Close |
2887 |
select |
2888 |
%{ConfigChanged_Para_ID} (%{ConfigChanged_Para_ID_Ext})
%{ConfigChanged_OldValue_Int} -> %{ConfigChanged_NewValue_Int} |
2889 |
%{ConfigChanged_Para_ID} (%{ConfigChanged_Para_ID_Ext})
%{ConfigChanged_OldValue_Int} %{ConfigChanged_Unit_ID} -> %{ConfigChanged_NewValue_Int} %{ConfigChanged_Unit_ID} |
2890 |
%{ConfigChanged_Para_ID} (%{ConfigChanged_Para_ID_Ext})
%{ConfigChanged_OldValue_Enum} -> %{ConfigChanged_NewValue_Enum} |
2891 |
%{ConfigChanged_Para_ID} (%{ConfigChanged_Para_ID_Ext})
%{ConfigChanged_OldValue_Enum} %{ConfigChanged_Unit_ID} -> %{ConfigChanged_NewValue_Enum} %{ConfigChanged_Unit_ID} |
2892 |
%{ConfigChanged_Para_ID} (%{ConfigChanged_Para_ID_Ext})
%{ConfigChanged_OldValue_Float} -> %{ConfigChanged_NewValue_Float} |
2893 |
%{ConfigChanged_Para_ID} (%{ConfigChanged_Para_ID_Ext})
%{ConfigChanged_OldValue_Float} %{ConfigChanged_Unit_ID} -> %{ConfigChanged_NewValue_Float} %{ConfigChanged_Unit_ID} |
2894 |
%{ConfigChanged_Para_ID} (%{ConfigChanged_Para_ID_Ext}) |