0 |
6u |
1 |
FMR53x |
2 |
|
3 |
electronics defect A111 |
4 |
electronics defect A113 |
5 |
electronics defect A114 |
6 |
electronics defect A164 |
7 |
checksum error general reset & new calibr.required A102 |
8 |
electronics defect A121 |
9 |
electronics defect A171 |
10 |
checksum error general reset & new calibr.required A110 |
11 |
checksum error general reset & new calibr.required A160 |
12 |
electronics defect A155 |
13 |
sensor 1 defect check connection A231 |
14 |
electronics defect A115 |
15 |
electronics defect amplifier A272 |
16 |
downloading please wait A106 |
17 |
download error repeat download A116 |
18 |
no usable echo channel 1 check calibr. E641 |
19 |
linearisation ch1 not complete, not usable A671 |
20 |
level in safety distance - risk of overspill E651 |
21 |
custody switch undef check position A270 |
22 |
reduced accuracy check installation W271 |
23 |
reduced accuracy W273 |
24 |
reduced accuracy check pipe diameter W274 |
25 |
electronics defect factory settings W275 |
26 |
current ch1 out of range W681 |
27 |
recording of mapping please wait W512 |
28 |
no factory cali- bration ch1 W511 |
29 |
less than 2 linea- risation points for channel 1 W611 |
30 |
linearisation ch1 curve not monotone W601 |
31 |
simulation ch. 1 on W621 |
32 |
initialising - please wait W103 |
33 |
initialising - please wait W153 |
34 |
PERCENT RANGE |
35 |
% |
36 |
6.1f |
37 |
horizonzal zyl. |
38 |
manual |
39 |
semi automatic |
40 |
activate table |
41 |
clear table |
42 |
MIN. SPAN |
43 |
LOW SENSOR LIMIT |
44 |
.4f |
45 |
HIGH SENSOR LIMIT |
46 |
SERIAL-NO. SENS. |
47 |
7u |
48 |
FORMAT |
49 |
01u |
50 |
NUL_UNIT |
51 |
none |
52 |
DUMMY_FLOAT |
53 |
no.of decimals |
54 |
x |
55 |
x.x |
56 |
x.xx |
57 |
x.xxx |
58 |
x.xxxx |
59 |
measured value |
60 |
9.0f |
61 |
9.1f |
62 |
9.2f |
63 |
9.3f |
64 |
9.4f |
65 |
unlock parameter |
66 |
6.1u |
67 |
tank shape |
68 |
dome ceiling |
69 |
horizontal cyl |
70 |
bypass |
71 |
stilling well |
72 |
flat ceiling |
73 |
sphere |
74 |
medium property |
75 |
unknown |
76 |
DC: < 1.9 |
77 |
DC: 1.9 ... 4 |
78 |
DC: 4 ... 10 |
79 |
DC: > 10 |
80 |
process cond. |
81 |
standard |
82 |
calm surface |
83 |
turb. surface |
84 |
add. agitator |
85 |
fast change |
86 |
test:no filter |
87 |
distance process
conn. to min. level |
88 |
empty calibr. |
89 |
distance unit |
90 |
m |
91 |
ft |
92 |
mm |
93 |
inch |
94 |
span |
95 |
full calibr. |
96 |
inner diameter of
bypass/stilling well |
97 |
pipe diameter |
98 |
only after
first installation |
99 |
history reset |
100 |
no |
101 |
yes |
102 |
output on alarm |
103 |
MIN (<=3.6mA) |
104 |
MAX (22mA) |
105 |
hold |
106 |
user specific |
107 |
output on alarm |
108 |
7.2f |
109 |
mA |
110 |
outp. echo loss |
111 |
alarm |
112 |
ramp %/min |
113 |
ramp %span/min |
114 |
10.3f |
115 |
%/min |
116 |
in case of echo loss
max. 4000 sec. |
117 |
delay time |
118 |
5.1u |
119 |
s |
120 |
from antenna tip/
lower edge of horn |
121 |
safety distance |
122 |
in safety dist. |
123 |
warning |
124 |
self holding |
125 |
ackn. alarm |
126 |
overspill prot. |
127 |
german WHG |
128 |
auto correction |
129 |
off |
130 |
on |
131 |
pipe diam. corr. |
132 |
dip table mode |
133 |
view |
134 |
manual |
135 |
semi-automatic |
136 |
table on |
137 |
table off |
138 |
clear table |
139 |
uncorr meas val. |
140 |
dip table handl. |
141 |
next point |
142 |
previous point |
143 |
new point |
144 |
edit point |
145 |
store point |
146 |
delete point |
147 |
return |
148 |
dip value |
149 |
dip table state |
150 |
rem table entr. |
151 |
3.1u |
152 |
level/ullage |
153 |
level CU |
154 |
level DU |
155 |
ullage CU |
156 |
ullage DU |
157 |
linearisation |
158 |
linear |
159 |
customer unit |
160 |
l |
161 |
hl |
162 |
m3 |
163 |
dm3 |
164 |
cm3 |
165 |
ft3 |
166 |
usgal |
167 |
i gal |
168 |
kg |
169 |
t |
170 |
lb |
171 |
ton |
172 |
 j |
173 |
table no. |
174 |
input level |
175 |
input volume |
176 |
max. scale |
177 |
diameter vessel |
178 |
check distance |
179 |
distance = ok |
180 |
dist.too small |
181 |
dist. too big |
182 |
dist. unknown |
183 |
input of
mapping range |
184 |
range of mapping |
185 |
start mapping |
186 |
pres. map dist. |
187 |
cust. tank map |
188 |
inactive |
189 |
active |
190 |
reset |
191 |
echo quality |
192 |
4.1u |
193 |
dB |
194 |
will be added to the
measured level |
195 |
offset |
196 |
output damping |
197 |
5.1f |
198 |
blocking dist. |
199 |
commun. address |
200 |
2.0i |
201 |
no. of preambels |
202 |
low output limit |
203 |
fixed current |
204 |
fixed cur. value |
205 |
8.2f |
206 |
simulation |
207 |
sim. off |
208 |
sim. level |
209 |
sim. volume |
210 |
sim. current |
211 |
simulation value |
212 |
output current |
213 |
5.2f |
214 |
language |
215 |
English |
216 |
Deutsch |
217 |
Français |
218 |
Italiano |
219 |
Español |
220 |
Nederlands |
221 |
Japanese |
222 |
back to home |
223 |
format display |
224 |
decimal |
225 |
ft-in-1/16'' |
226 |
sep. character |
227 |
. |
228 |
, |
229 |
present error |
230 |
|
231 |
A101
checksum error
general reset & new
calibr.required |
232 |
A102
checksum error
general reset & new
calibr.required |
233 |
W103
initialising -
please wait
|
234 |
A106
downloading
please wait
|
235 |
A110
checksum error
general reset & new
calibr.required |
236 |
A111
electronics defect
|
237 |
A113
electronics defect
|
238 |
A114
electronics defect
|
239 |
A115
fault power supply
|
240 |
A116
download error
repeat download
|
241 |
A121
electronics defect
|
242 |
A152
checksum error
general reset & new
calibr.required |
243 |
W153
initialising -
please wait
|
244 |
A155
electronics defect
|
245 |
A160
checksum error
general reset & new
calibr.required |
246 |
A164
electronics defect
|
247 |
A171
electronics defect
|
248 |
A231
sensor 1 defect
check connection
|
249 |
A270
custody switch undef
check position
|
250 |
W271
reduced accuracy
check installation
|
251 |
A272
electronics defect
amplifier
|
252 |
W273
reduced accuracy
|
253 |
W274
reduced accuracy
check pipe diameter
|
254 |
W275
electronics defect
factory settings
|
255 |
W511
no factory cali-
bration ch1
|
256 |
W512
recording of mapping
please wait
|
257 |
W601
linearisation ch1
curve not monotone
|
258 |
W611
less than 2 linea-
risation points
for channel 1 |
259 |
W621
simulation ch. 1
on
|
260 |
E641
no usable echo
channel 1
check calibr. |
261 |
E651
level in safety
distance - risk
of overspill |
262 |
A671
linearisation ch1
not complete,
not usable |
263 |
W681
current ch1 out
of range
|
264 |
previous error |
265 |
clear last error |
266 |
keep |
267 |
erase |
268 |
for reset code
see manual |
269 |
reset |
270 |
measured dist. |
271 |
measured level |
272 |
application par. |
273 |
not modified |
274 |
modified |
275 |
custody mode |
276 |
active pos. |
277 |
active neg. |
278 |
tag no. |
279 |
protocol+sw-no. |
280 |
custody transfer |
281 |
software no. |
282 |
serial no. |
283 |
download mode |
284 |
parameter only |
285 |
param+cust.map |
286 |
mapping only |
287 |
pres. amplitude |
288 |
4.1i |
289 |
ampl. over map. |
290 |
ampl. over FAC |
291 |
unfilt. distance |
292 |
pres. edge param |
293 |
present FEF |
294 |
device name |
295 |
order code |
296 |
MAM filt. length |
297 |
MAM filt. border |
298 |
low pass filter |
299 |
4.1f |
300 |
hysterese width |
301 |
8.3f |
302 |
max. fill. speed |
303 |
inch/s |
304 |
mm/s |
305 |
max. drain speed |
306 |
unfilt. dist.raw |
307 |
unflt. dist.fine |
308 |
unflt.dist.phase |
309 |
env. statistics |
310 |
env. smoothing |
311 |
env. avg. count |
312 |
1 |
313 |
4 |
314 |
8 |
315 |
16 |
316 |
ZF average |
317 |
envel. energy |
318 |
7.1f |
319 |
mapping adder |
320 |
mapping scanrate |
321 |
mapping average |
322 |
fact. map. valid |
323 |
FAC adder |
324 |
FAC scan rate |
325 |
range fact. map |
326 |
not active |
327 |
active |
328 |
cust. map. valid |
329 |
edge detec. mode |
330 |
front of echo |
331 |
edge parameter |
332 |
first echo fact. |
333 |
FEF threshold |
334 |
FEF at near dist |
335 |
FEF dist. near |
336 |
FEF dist. far |
337 |
FEF edge |
338 |
max.ampl.o.FAC |
339 |
Tank Bottom Det. |
340 |
min. ampl. TBD |
341 |
max. level TBD |
342 |
fill/drain speed |
343 |
HF module |
344 |
µP II.1 |
345 |
µP II.2 |
346 |
µP III.1 |
347 |
µP III.2 |
348 |
zero distance |
349 |
pres. micro fact |
350 |
module frequency |
351 |
MHz |
352 |
trig. fail count |
353 |
antenna type |
354 |
rod aerial |
355 |
horn aerial |
356 |
dish antenna |
357 |
planar antenna |
358 |
inactive length |
359 |
total length |
360 |
max. meas. dist. |
361 |
pos. ref. pulse |
362 |
ampl. ref. pulse |
363 |
qual. calc. PD |
364 |
present PD |
365 |
anal.phase state |
366 |
IC save begin |
367 |
IC save end |
368 |
IC state |
369 |
2.1u |
370 |
fine env. varia. |
371 |
aut. base gain |
372 |
base gain val. |
373 |
automatic gain |
374 |
near dist. gain |
375 |
far dist. gain |
376 |
distance gain |
377 |
pres. gain value |
378 |
Plausib.Function |
379 |
PF maximum delta |
380 |
PF upper area |
381 |
display version |
382 |
calc. cycle time |
383 |
ms |
384 |
temp. of electr. |
385 |
°C |
386 |
sw. vers. appl. |
387 |
7.1u |
388 |
para. vers. appl |
389 |
D/A adjust 4mA |
390 |
D/A adjust 20mA |
391 |
debug index 1 |
392 |
debug index 2 |
393 |
debug value |
394 |
11.3f |
395 |
err. state alg. |
396 |
10.1u |
397 |
state algorithm |
398 |
HW fail counter |
399 |
MEAS_VAL_UNIT |
400 |
VARIABLE_ARRAY_INDEX |
401 |
VARIABLE_ARRAY_VALUE |
402 |
VARIABLE_ARRAY_UNIT |
403 |
FORMAT_TABLE_INDEX |
404 |
FORMAT_TABLE |
405 |
%-RANGE |
406 |
Set to nearest possible value |
407 |
Invalid value selection |
408 |
basic setup |
409 |
safety settings |
410 |
mounting calibr. |
411 |
linearisation |
412 |
extended calibr. |
413 |
output |
414 |
display |
415 |
service |
416 |
info |
417 |
distance |
418 |
envelope |
419 |
mapping |
420 |
edge |
421 |
first echo |
422 |
tank bottom |
423 |
module |
424 |
antenna table |
425 |
algorithm 1 |
426 |
algorithm 2 |
427 |
gain settings |
428 |
system 1 |
429 |
system 2 |
430 |
debug |
431 |
diagnostics |
432 |
system parameters |
433 |
MATRIX GROUP SEL. |
434 |
DEVICE DATA |
435 |
HART OUTPUT |
436 |
UPLOAD |
437 |
Reset Configuration Changed Flag |
438 |
Restart Device |
439 |
Synchronize tag to parTagNumber |
440 |
Synchronize parTagNumber to tag |
441 |
FMU860 |
442 |
DT |
443 |
DVC |
444 |
FCX |
445 |
AS800 |
446 |
340T |
447 |
340C |
448 |
344 |
449 |
Siemens Micro K |
450 |
SITRANS L |
451 |
SIPAN PH |
452 |
SITRANS P |
453 |
75SMT |
454 |
UNIDELTA |
455 |
8320 |
456 |
SX5100 |
457 |
TSV175 |
458 |
DMU |
459 |
3780 |
460 |
BM70 |
461 |
8u |
462 |
Do you want to reset the 'Config Changed Flag' ? |
463 |
Attention ! Device will be restarted !
Loss of information possible ! |