0 |
Dynisco |
1 |
IPX II |
2 |
Tag |
3 |
Date |
4 |
Month / Day / Year |
5 |
Message |
6 |
Xmtr Serial Number |
7 |
Current Status of transmitter standard measurements |
8 |
AD Zero Circuit Temperature Fault |
9 |
AD Zero Sensor Fault |
10 |
AD Full Scale Sensor Fault |
11 |
AD Zero RTD 1 Sensor Fault |
12 |
AD Full Scale Circuit Temperature Fault |
13 |
AD Circuit Temperature Fault |
14 |
AD Zero RTD 2 Sensor Fault |
15 |
Historical Status of transmitter standard measurements |
16 |
Current Status of System Values |
17 |
Current System EEPROM Fault |
18 |
Current System Circuit Temperature Fault |
19 |
Past System EEPROM Fault |
20 |
Past System Circuit Temperature Fault |
21 |
Current Status of Fault Codes for Sensors |
22 |
AD RTD 1 Sensor Fault |
23 |
Sensor Over Range Fault |
24 |
AD FS RTD1 Sensor Fault |
25 |
AD RTD 2 Sensor Fault |
26 |
AD FS RTD2 Sensor Fault |
27 |
Historical Status of Fault Codes for Sensors |
28 |
Past AD RTD 1 Sensor Fault |
29 |
Past Sensor Over Range Fault |
30 |
Past AD FS RTD1 Sensor Fault |
31 |
Past AD RTD 2 Sensor Fault |
32 |
Past AD FS RTD2 Sensor Fault |
33 |
RTD1 Open Sensor High |
34 |
RTD1 Open Sensor Low |
35 |
Open Sensor High SL |
36 |
Open Sensor Low SL |
37 |
Open Sensor High BL |
38 |
Open Sensor Low BL |
39 |
RTD2 Open Sensor High |
40 |
RTD2 Open Sensor Low |
41 |
RTD1 Open Sensor was High |
42 |
RTD1 Open Sensor was Low |
43 |
Open Sensor was High SL |
44 |
Open Sensor was Low SL |
45 |
Open Sensor was High BL |
46 |
Open Sensor was Low BL |
47 |
RTD2 Open Sensor was High |
48 |
RTD2 Open Sensor was Low |
49 |
Trim 4-20mA |
50 |
TNumber |
51 |
5K 1 RTD |
52 |
5K 1 RTD NO OS |
53 |
0.35K 1 RTD |
54 |
0.35K 1 RTD NO OS |
55 |
5K 2 RTD |
56 |
5K 2 RTD NO OS |
57 |
0.35K 2 RTD |
58 |
0.35K 2 RTD NO OS |
59 |
Line Freq & Filter |
60 |
Indicates the power line frequency selected. |
61 |
50Hz |
62 |
60Hz |
63 |
Smart Smoothing |
64 |
5.2f |
65 |
Deadband |
66 |
Smart Smoothing Deadband |
67 |
Validation Count |
68 |
Validation Count can be between 0 and 100. |
69 |
Display Language |
70 |
The language used by the local display. |
71 |
English |
72 |
German |
73 |
French |
74 |
Spanish |
75 |
Italian |
76 |
Sensor Type |
77 |
AP |
78 |
GP |
79 |
DP |
80 |
Sensor SubType |
81 |
Defines the sensor sub type. |
82 |
SPECIAL |
83 |
AP-3.63 |
84 |
AP-36.3 |
85 |
AP-363 |
86 |
GP-3.63 |
87 |
GP-36.3 |
88 |
GP-363 |
89 |
GP-3630 |
90 |
GP-23200 |
91 |
DP-4 |
92 |
DP-25.7 |
93 |
DP-257 |
94 |
DP-1600 |
95 |
DP-16000 |
96 |
RTD2 |
97 |
Failure Detect |
98 |
Switches the failure detection system on or off. If switched off, the analog output will notreact to a failure. |
99 |
Failsafe Report |
100 |
In case of a failure the analog output is set to the failsafe mA value. Min value - 3.6, Max value - 23.0. |
101 |
2cd mA Source |
102 |
Second mA Source |
103 |
Sensor RTD |
104 |
Xmtr Temp |
105 |
RTD2 Temp |
106 |
SqRootMode |
107 |
Enables or disables the Square Root Function |
108 |
SqRootTrunc |
109 |
Truncation limit for the Square Root Function |
110 |
SqRootFlowFS |
111 |
Flow at sensor Full Scale |
112 |
DispPrec |
113 |
Display Precision |
114 |
SecmAOut |
115 |
Second Ma Out |
116 |
Display Label |
117 |
Label that appears on the local display, max.21 characters. |
118 |
7.2f |
119 |
Special characterization not available |
120 |
Invalid number of pairs of values, 2 - 22 pairs allowed. |
121 |
Warning: Turning Sensor Offset Curve System ON |
122 |
|
123 |
SecmAURV |
124 |
Second mA Output Upper Range Value. |
125 |
SecmA LRV |
126 |
Second mA Output Lower Range Value. |
127 |
SecmAOut Value |
128 |
Sec mA Output value. |
129 |
mA |
130 |
Density |
131 |
Density of the Flow Media |
132 |
Density Units |
133 |
Units used for density |
134 |
Totalizer |
135 |
Enables or disables the Totalizer Function |
136 |
Accumulation |
137 |
Total Flow since Totalizer function was enabled or reset |
138 |
Totalizer Units |
139 |
Units used for totalizer function. |
140 |
Engineering Units |
141 |
PV AOut |
142 |
Analog Output in mA. |
143 |
Damping |
144 |
Exponential damping of input signal, maximum time constant 32 seconds. |
145 |
.2f |
146 |
4.2f |
147 |
USL |
148 |
LSL |
149 |
Sensor Serial # |
150 |
7d |
151 |
% Range |
152 |
PV in percent of range. |
153 |
URV |
154 |
URV - Upper Range Value. |
155 |
LRV |
156 |
LRV - Lower Range Value. |
157 |
Flow |
158 |
Pressure |
159 |
Percent |
160 |
Flow in Engineering Units. |
161 |
Pressure in Engineering Units |
162 |
Percent of Full Scale |
163 |
Sensor Bridge Temp |
164 |
Sensor Bridge Temperature. |
165 |
Sensor Temp Units |
166 |
Select the units used for the Sensor Bridge Temperature measurement. |
167 |
Elec Int Temp |
168 |
Electronics Internal Temperature. |
169 |
4.0f |
170 |
Xmtr Temp Units |
171 |
Select the units used for the Electronics Internal Temperature measurement. |
172 |
Snout Temp |
173 |
Snout Temperature value |
174 |
Snout Temp Units |
175 |
Select the units used for the Snout Temperature measurement. |
176 |
Snsr Offset Curve |
177 |
Correction or characterization of input sensor(s). 2-22 pairs of values. |
178 |
Offset Curve Stat. |
179 |
Display the status of the Sensor Offset Curve System. |
180 |
Pressure Units |
181 |
Flow Units |
182 |
Engineering Units |
183 |
Set the engineering unit to be displayed with the Digital Value representation, Upper Range Value, Lower Range Value, and Square Root Values. |
184 |
Set the engineering unit to be displayed with the Digital Value representation, Upper Range Value and Lower Range Value. |
185 |
Exit Engineering Units Setup |
186 |
Xmtr Int Units |
187 |
Set the units to be displayed with the Sensor Bridge and Electronics Internal Temperatures. |
188 |
Exit Non PV Units Setup |
189 |
Set the units to be displayed with the Snout Temperature. |
190 |
Exit RTD 2 Units Setup |
191 |
Line Freq & Filt |
192 |
Set the power line frequency and filter. |
193 |
Exit Line Freq & Filter Setup |
194 |
Smart Smoothing |
195 |
Exit Smart Smoothing Setup |
196 |
Set LRV |
197 |
Specify the Lower Range Value, (the 4ma value). |
198 |
Exit LRV Setup |
199 |
Set URV |
200 |
Specify the Upper Range Value, (the 20ma value). |
201 |
Exit URV Setup |
202 |
Apply LRV |
203 |
Perform a device rerange by applying the 4ma value to the device input. |
204 |
Apply URV |
205 |
Perform a device rerange by applying the 20ma value to the device input. |
206 |
Set Damping |
207 |
Specify exponential damping of input signal, maximum time constant 32 seconds. |
208 |
Exit DAMPING Setup |
209 |
Temperature |
210 |
Specify the Upper Range Value, (the 20mA value), and the Lower Range Value, (the 4ma value) for the Second mA Output. |
211 |
Exit Sec mA URV/LRV Setup |
212 |
Failsafe Setup |
213 |
Configuration of the mA output upon failsafe. |
214 |
Exit Failsafe Setup |
215 |
Sensor Pos Adjust |
216 |
Adjust sensor position. |
217 |
Zero Trim |
218 |
Zero Trim. |
219 |
Full Scale Trim |
220 |
Full Scale Trim. |
221 |
Reset Trim |
222 |
Reset sensor position trim to factory values. |
223 |
Trim 4-20mA |
224 |
Clear Hist Status |
225 |
Clear the historical status information for failures. The historical status information is not automatically cleared when the failure is removed. They have to be cleared manually. |
226 |
Offline Configuration |
227 |
Online |
228 |
Offline |
229 |
Display Data |
230 |
Review Setup |
231 |
Review Input |
232 |
Xmtr Setup |
233 |
Input Setup |
234 |
Output Setup |
235 |
Trim |
236 |
Sensor Trim |
237 |
Output Trim |
238 |
Other Setup |
239 |
Xmtr Filtering |
240 |
Local Display |
241 |
Xmtr Identifiers |
242 |
Tag Setup |
243 |
Device Information |
244 |
Diagnostics |
245 |
Xmtr Internal Diag |
246 |
Failure Status |
247 |
Xmtr Internal Vars |
248 |
FMU860 |
249 |
DT |
250 |
DVC |
251 |
FCX |
252 |
AS800 |
253 |
340T |
254 |
340C |
255 |
344 |
256 |
Siemens Micro K |
257 |
SITRANS L |
258 |
SIPAN PH |
259 |
SITRANS P |
260 |
75SMT |
261 |
UNIDELTA |
262 |
8320 |
263 |
SX5100 |
264 |
TSV175 |
265 |
DMU |
266 |
3780 |
267 |
BM70 |
268 |
8u |
269 |
Enter the number of pairs of values, (Min-2, Max-22) |
270 |
There must be at least 2 pairs of values. |
271 |
Point %{local_pos} Indicated Value
Unit: %{0} |
272 |
Actual Value
Unit: %{0} |
273 |
Sensor Offset Curve System OFF |
274 |
Sensor Offset Curve System ON with %{0} pairs of values. |
275 |
Engineering Units set to %{0}. |
276 |
Electronics Internal Temp Units |
277 |
Sensor Bridge Temp Units |
278 |
Electronics Internal Temp Units set to %{1}. |
279 |
Sensor Bridge Temp Units set to %{0}. |
280 |
Snout Temperature Units |
281 |
Snout Temperature Units set to %{0}. |
282 |
Line Frequency |
283 |
Line Freq. & Filter set to %{0}. |
284 |
Enter Smart Smoothing value
(0-30) |
285 |
Enter Smoothing Deadband
(0-32000) |
286 |
Enter Validation Count
(0-100) |
287 |
Smart Smoothing set to %{0} sec., Deadband = %{1}, Validation Count = %{2} |
288 |
Enter LRV |
289 |
LRV set to %{0} %{1} |
290 |
Enter URV |
291 |
URV set to %{0} %{1} |
292 |
PV = %{1} %{2}
LRV = %{0} %{2} |
293 |
New LRV %{1} |
294 |
Accept new value;Read new value;Abort |
295 |
Please wait. |
296 |
PV = %{1} %{2}
URV = %{0} %{2} |
297 |
New URV %{1} |
298 |
Enter Damping
(32 sec. maximum) |
299 |
Damping set to %{0} sec. |
300 |
Enter Sec mA URV |
301 |
Enter Sec mA LRV |
302 |
Sec mA URV set to %{0} %{1}, Sec mA LRV set to %{2} %{1} |
303 |
Sensor Failsafe Detection |
304 |
Sensor Failsafe Detection
OFF |
305 |
Sensor Failsafe Detection
ON
Failsafe Report
%{0}mA |
306 |
Set sensor to zero, press OK when ready. |
307 |
Sensor postion adjusted successfully. |
308 |
Apply sensor zero (4mA) pressure. |
309 |
Sensor zero (4mA) pressure applied successfully. |
310 |
Apply sensor full scale (20mA) pressure. |
311 |
Sensor full scale (20mA) pressure applied successfully. |
312 |
OK to reset sensor position and trim to Factory Values? |
313 |
Sensor position and trim rest to factory values. |
314 |
Secondary mA output is fixed at %0 mA |
315 |
Setting secondary mA output to 4mA |
316 |
Secondary mA output %0 mA equal to reference meter? |
317 |
Setting secondary mA output to 20mA |
318 |
Clear historical status? |
319 |
No;Yes |
320 |
Historical status NOT cleared. |
321 |
Historical status cleared. |