0 |
BiT (Barksdale Intelligent Transmitter) |
1 |
Barksdale Control Products |
2 |
PV Over-Range |
3 |
PV Under-Range |
4 |
Reserved |
5 |
Loop Test |
6 |
Pressure |
7 |
Pressure |
8 |
.3f |
9 |
Pres Dev fmly |
10 |
Pres Class |
11 |
Pres PDQ |
12 |
Pres LS |
13 |
Pres Fmly stat |
14 |
Pressure Update Period |
15 |
|
16 |
7d |
17 |
Pres Lower trim |
18 |
Pres Upper trim |
19 |
Pres Trim support |
20 |
Pres Min lower trim |
21 |
Pres Max lower trim |
22 |
Pres Min upper trim |
23 |
Pres Max upper trim |
24 |
Pres Min trim diff |
25 |
Simulate |
26 |
Update Period |
27 |
Build Number |
28 |
1.2f |
29 |
Product Configuration |
30 |
Device Variables |
31 |
Primary Variables |
32 |
PV Measurement |
33 |
Range Values |
34 |
PV Status |
35 |
Shortcut |
36 |
Pressure Trend |
37 |
Device Information |
38 |
Identification |
39 |
Device Identification |
40 |
Revisions |
41 |
Device Setup |
42 |
Guided Setup |
43 |
Performs Zero Calibration |
44 |
Restores the process zero to the factory settings |
45 |
Performs loop test |
46 |
Rerange the limits |
47 |
Manual Setup |
48 |
Basic Setup |
49 |
Pressure Sensor |
50 |
Ranging |
51 |
Output Setup |
52 |
HART Setup |
53 |
Diagnostics |
54 |
Status |
55 |
More device Status |
56 |
Start |
57 |
Device Status |
58 |
Ext Fld Device Status |
59 |
Primary Variable |
60 |
Restore Factory Zero |
61 |
Restores the process zero to the factory settings. |
62 |
PV Analog Channel Saturated |
63 |
PV Analog Channel Fixed |
64 |
Wireless |
65 |
WirelessHART Device |
66 |
IEEE 802.15.4 2.4GHz DSSS with O-QPSK Modulation |
67 |
Primary |
68 |
Primary Analog Channel |
69 |
Secondary |
70 |
Secondary Analog Channel |
71 |
Tertiary |
72 |
Tertiary Analog Channel |
73 |
Quaternary |
74 |
Quaternary Analog Channel |
75 |
Quinary |
76 |
Quinary Analog Channel |
77 |
Critical Power Failure |
78 |
Lock all |
79 |
Trim not supported |
80 |
Configuration cannot be changed |
81 |
Locked by gateway |
82 |
Analog Input Channel |
83 |
Analog Output Channel |
84 |
Secondary Analog Channel Saturated |
85 |
Tertiary Analog Channel Saturated |
86 |
Quaternary Analog Channel Saturated |
87 |
Quinary Analog Channel Saturated |
88 |
Secondary Analog Channel Fixed |
89 |
Tertiary Analog Channel Fixed |
90 |
Quaternary Analog Channel Fixed |
91 |
Quinary Analog Channel Fixed |
92 |
Simulation active |
93 |
The device is in simulation mode and the level output is not representative of the process. |
94 |
Non-Volatile memory failure |
95 |
The Non-Volatile memory check is invalid or maybe corrupt, or the battery of a battery-backed memory has failed. |
96 |
Volatile memory error |
97 |
The RAM memory check is invalid or maybe corrupt |
98 |
Watchdog reset executed |
99 |
A watchdog reset has been performed |
100 |
Voltage conditions out of range |
101 |
A voltage condition is outside its allowable range |
102 |
Environmental conditions out of range |
103 |
An internal or environmental condition is beyond acceptable limits. |
104 |
Electronic failure |
105 |
A hardware problem not related to the sensor has been detected. |
106 |
Subdevice list changed |
107 |
Duplicate master detected |
108 |
Capacity Denied |
109 |
The device was unable to acquire the communication bandwidth required to support the Burst Messaging specified |
110 |
Bandwidth allocation pending |
111 |
Block transfer pending |
112 |
Battery life |
113 |
Percent range |
114 |
Loop current |
115 |
Primary variable |
116 |
Secondary variable |
117 |
Tertiary variable |
118 |
Quaternary variable |
119 |
Read receive time |
120 |
Write date and time |
121 |
Non-Volatile Clock |
122 |
When set the device contains a battery-backed clock. In this case, the clock does not need to be reset if there is a power failure. |
123 |
Clock Uninitialized |
124 |
The real-time clock has never been set with the date and time. For example, the clock is volatile and power was removed from and restored to the device. |
125 |
None |
126 |
No restrictions |
127 |
SI Only |
128 |
Restricted to SI Unit codes only |
129 |
Process automation device |
130 |
Discrete device |
131 |
Hybrid:Process automation+discrete |
132 |
I/O System |
133 |
WirelessHART Process automation device |
134 |
WirelessHART Discrete device |
135 |
WirelessHART Process automation+discrete |
136 |
WirelessHART Gateway |
137 |
WirelessHART Access point |
138 |
WirelessHART Process adapter |
139 |
WirelessHART Discrete adapter |
140 |
WirelessHART enabled handheld/portable maintenance tool |
141 |
Device Profile |
142 |
US |
143 |
United States of America |
144 |
JP |
145 |
Japan |
146 |
DE |
147 |
Germany |
148 |
FR |
149 |
France |
150 |
ES |
151 |
Spain |
152 |
RU |
153 |
Russian Federation |
154 |
CN |
155 |
People's Republic of China |
156 |
Secondary Master |
157 |
Primary Master |
158 |
Device Diagnostic Status 0 |
159 |
Device Diagnostic Status 1 |
160 |
I/O and Subdevice Status |
161 |
WirelessHART Status |
162 |
Time Set Option |
163 |
Real Time Clock Flags |
164 |
Country |
165 |
Country of intended device installation |
166 |
SI Unit Control |
167 |
Indicates if device should only display SI unit codes |
168 |
Time Stamp |
169 |
Relative time value on network |
170 |
8u |
171 |
Dynamic Variables Returned for Device Variables |
172 |
Command Response Truncated |
173 |
Configuration Change Counter Mismatch |
174 |
Status bytes mismatch |
175 |
8.3f |
176 |
Device Variable |
177 |
Variable to trim |
178 |
This will restore the factory zero, continue? |
179 |
Yes;Exit |
180 |
Factory zero restored successfully, loop my be resturned to automatic control. |
181 |
other_value |