0 |
IZMS Flowmeter |
1 |
Anderson Instr. |
2 |
Operation Status |
3 |
BadConfiguration |
4 |
DAC Gain Not Calibrated |
5 |
DAC Zero Not Calibrated |
6 |
Unique ID Not Set |
7 |
Lost Communication |
8 |
Critical Power Failure. |
9 |
Device Variable Alert. |
10 |
Maintenance Required. |
11 |
Electronic Defect |
12 |
Environmental Conditions Out of Range. |
13 |
Voltage Out of Range. |
14 |
Watchdog Reset Executed. |
15 |
Volatile Memory Defect. |
16 |
Non-volatile Memory Defect. |
17 |
Simulation Active. |
18 |
Flow Rate |
19 |
Volume1 |
20 |
Volume2 |
21 |
Total Volume |
22 |
Damping |
23 |
Flow Rate Units |
24 |
ml/min |
25 |
GAL CDN/min |
26 |
ml/hr |
27 |
GAL CDN/hr |
28 |
V |
29 |
TBD |
30 |
0.2f |
31 |
USL |
32 |
LSL |
33 |
sec |
34 |
Not Classified |
35 |
7d |
36 |
Total 1 |
37 |
Total 2 |
38 |
Total 3 |
39 |
Units |
40 |
ml |
41 |
GAL CDN |
42 |
Total 1 (V) |
43 |
.0f |
44 |
.1f |
45 |
.2f |
46 |
.3f |
47 |
.4f |
48 |
.5f |
49 |
.6f |
50 |
Total 2 (V2) |
51 |
Total 3 (SV) |
52 |
m dim |
53 |
DN |
54 |
Pipe Diameter of the Tranmsitter |
55 |
4.1f |
56 |
mm |
57 |
LFS |
58 |
Deterines the threshold value above which the flow totalizer is active.This setting is a percentage of the full-scale rate Qmax |
59 |
% |
60 |
Average |
61 |
Determines the number of individual measurements required for the value calculation, i.e. determines the response time of the display. |
62 |
1 |
63 |
2 |
64 |
4 |
65 |
8 |
66 |
16 |
67 |
32 |
68 |
Pipe Detect |
69 |
Enables or Disables the internal Empty Pipe Detection which suppresses erroneous flow measurement caused by a partially empty flow tube. |
70 |
Disabled |
71 |
Enabled |
72 |
Output Mode |
73 |
Determines the operation of the pulse outputs. |
74 |
2u |
75 |
Current mode |
76 |
Determines the electrical characteristic of the analog output. |
77 |
0-20 mA. |
78 |
4-20 mA. |
79 |
Standby Mode |
80 |
Reduces power consumption during metering pauses by turnin off meter coil excitation current. |
81 |
0 |
82 |
Parameter Mode |
83 |
Security function for the parameters which allows the parameters to be protected agains unauthorized changes. |
84 |
Qmax |
85 |
Determines the scaling of the analog output, 100% Qmax = 20 mA. |
86 |
pv1 |
87 |
Determines the number of pulses per volume unit seen at output IMP1. Value pv1 is used when several channels are available. |
88 |
pulses/unit Volume |
89 |
pv2 |
90 |
Determines the number of pulses per volume unit seen at output IMP2. Only inflow is possible at Output-mode 1.5. |
91 |
tp1 |
92 |
Determines the maximum ON time duration for the pulse output IMP1. |
93 |
msec. |
94 |
tp2 |
95 |
Determines the maximum ON time duration for the pulse output IMP2. |
96 |
Meter Out Damp (tp3) |
97 |
Damping of optional analog output 0/4-20 mA. |
98 |
it1 |
99 |
Debouncing time Minimum ON time duration required at the digital input IN1 to recognize a valid input. |
100 |
it2 |
101 |
Debouncing time Minimum ON time duration required at the digital input IN2 to recognize a valid input. |
102 |
it3 |
103 |
Debouncing time Minimum ON time duration required at the digital input IN3 to recognize a valid input. |
104 |
it4 |
105 |
Debouncing time Minimum ON time duration required at the digital input IN4 to recognize a valid input. |
106 |
Q-Typ |
107 |
Determines whether the flow rate indication is displayed in units per Minute or per Hour such as gal/h or gal/min. |
108 |
per hr |
109 |
per min |
110 |
V1 Format |
111 |
Sets the number of digits displayed to the right of the decimal point for the display of the main totalizer V1. |
112 |
Decimal Places |
113 |
V2 Format |
114 |
Sets the number of digits displayed to the right of the decimal point for the display of the totalizer V2. |
115 |
Decimal Pt. |
116 |
Selects period (.) or comma (,) as the display symbol for the decimal point. |
117 |
Period (.) |
118 |
Comma (,) |
119 |
Display Mode |
120 |
Determines whether the display unit is to be additionally checked (for trade use). |
121 |
Non-approved systems |
122 |
Approved systems |
123 |
m spe |
124 |
Calibration factor: Factor serves to adjust the possible measuring deviations in the complete system. |
125 |
p spe |
126 |
Separate Evaluation Factor for the positive flow. |
127 |
n spe |
128 |
Separate Evaluation Factor for the negative flow. |
129 |
b spe |
130 |
Serves to adjust possible measureing deviations in the complete system for lower flow rates. |
131 |
Span |
132 |
Calibration value of the transmitter. |
133 |
.8f |
134 |
Offset |
135 |
Vmin |
136 |
Smallest permissible measuring amount. |
137 |
eprsum |
138 |
Display of checksum of the program. |
139 |
eparasum |
140 |
Display of checksum for the calibration data. |
141 |
nparasum |
142 |
Display of checksum for the other data. |
143 |
Sensor Type |
144 |
Display of sensor types |
145 |
Sensor Number |
146 |
Display of sensor number. |
147 |
User C2: |
148 |
System SS: |
149 |
Appli. SA: |
150 |
Switch Position |
151 |
Measure |
152 |
Cal |
153 |
Dac Zero |
154 |
|
155 |
Dac Full |
156 |
Invalid Password |
157 |
Invalid Index |
158 |
Master Reset |
159 |
Causes a reset in the HART Module. |
160 |
DebugValues |
161 |
Input Id |
162 |
Process Variables |
163 |
Primary Variables |
164 |
Identification |
165 |
Primary Measurements |
166 |
Range Values |
167 |
Totals |
168 |
PV |
169 |
Rate |
170 |
LRV |
171 |
URV |
172 |
Device Diagnostics |
173 |
Summary |
174 |
Device Status |
175 |
Warning |
176 |
Input/Output Setup |
177 |
Calibration |
178 |
Meter Info |
179 |
HART Info |
180 |
Meter Output |
181 |
Ranging |
182 |
Pulse Outputs |
183 |
Digital Input Debounce |
184 |
Factory Cal Parameters |
185 |
System Cal Parameters |
186 |
Loop Current Cal |
187 |
Meter Setup |
188 |
Display Setup |
189 |
Meter Versions |
190 |
Checksums |
191 |
Fixed Infor |
192 |
User Infor |
193 |
Revision Data |
194 |
Common Tables |
195 |
Interoperable * |
196 |
Universal |
197 |
Common Practice |
198 |
Pressure Universal |
199 |
Pressure Common |
200 |
Menu |
201 |
Rosemount Magflow |
202 |
Rosemount Pressure |
203 |
Moore Products |
204 |
Siemens Pressure |
205 |
P2 Common |
206 |
Munge |
207 |
Analytical Oxygen/Combustion/Methane/CO |
208 |
Flow Totalizer - Rate Indicator |
209 |
Flow Variable Area |
210 |
Flow Coriolis Mass |
211 |
Level Ultrasonic |
212 |
Level Radar - Microwave |
213 |
Pressure Absolute |
214 |
Level Capacitance |
215 |
Pressure Differential |
216 |
Level Hydrostatic |
217 |
Level |
218 |
Pressure Absolute/Relative |
219 |
Level Microwave |
220 |
Level Radar |
221 |
Level Density - Nuclear |
222 |
Pressure Deltabar S Evolution |
223 |
Pressure Cerabar S Evolution |
224 |
Flow Electromagnetic |
225 |
Flow Vortex |
226 |
Flow Magmeter - Rack Version |
227 |
Flow High Performance Magmeter |
228 |
Flow Mass |
229 |
Flow Ultrasonic |
230 |
Flow Magnetic |
231 |
Flow Magnetic - Custody Transfer |
232 |
Flow 2-wire Magnetic |
233 |
Flow Coriolis Mass - Custody Transfer |
234 |
Flow 2-wire Vortex |
235 |
Flow Thermal |
236 |
Temperature Head Mounted |
237 |
Temperature Compact |
238 |
Temperature DIN Rail Mounted |
239 |
Analytical pH |
240 |
Analytical Conductivity - Conductive |
241 |
Analytical Conductivity - Inductive |
242 |
Temperature Sensor |
243 |
Level Servo |
244 |
Temperature DIN Rail |
245 |
Temperature |
246 |
Analytical ORP |
247 |
Analytical pION |
248 |
Analytical IConc |
249 |
Analytical Electrode Conductivity |
250 |
Analytical Toroidal Conductivity |
251 |
Valve Controller |
252 |
Pressure |
253 |
Pressure Multivariable |
254 |
Analytical pH/ORP |
255 |
Flow Coriolis |
256 |
Analytical Conductivity |
257 |
Valve Positioner/Pneumatic |
258 |
Temperature Dual Input |
259 |
Valve Actuator |
260 |
Analytical Density - Nuclear |
261 |
Level Continuous Gamma |
262 |
Level Laser Ranging |
263 |
Pressure Safety |
264 |
Pressure P, dP + Multivariable |
265 |
Temperature 2-wire |
266 |
Pressure w/ PID |
267 |
Pressure Saturated Steam |
268 |
Analytical Density - Gamma Ray |
269 |
Level Gamma Ray |
270 |
Analytical Weight - Gamma Ray |
271 |
Level w/ Density - Gamma Ray |
272 |
Analytical Motorized Density |
273 |
Flow Multivariable Mass |
274 |
Temperature Multivariable |
275 |
Specialty HART-to-Analog Signal Conv |
276 |
Flow dP |
277 |
Pressure Low Power |
278 |
Pressure Certified SIL2 |
279 |
Interoperable |
280 |
Analytical Density |
281 |
Valve Positioner/Electropneumatic |
282 |
Flow Magnetic Inductive |
283 |
Flow |
284 |
Analytical Oxygen |
285 |
Analytical |
286 |
Analytical Opacity Monitor |
287 |
Analytical Oxygen/Combustion |
288 |
Analytical 2-wire Conductivity |
289 |
Analytical 2-wire Conductivity w/ pure H20 |
290 |
Analytical 2-wire Conductivity w/ % conc |
291 |
Analytical 2-wire Oxygen/Chlorine/Ozone |
292 |
Analytical 2-wire pH/ORP |
293 |
Analytical 2-wire Contacting/Toroidal |
294 |
Analytical Oxygen - High Temperature |
295 |
Analytical Conductivity w/ % conc |
296 |
Analytical pH/ORP/ISE |
297 |
Analytical Amperometric Analyzer |
298 |
Pressure Pressure/Level |
299 |
Analytical Consistency |
300 |
Analytical Microwave-Pulp Consistency |
301 |
Valve Digital Positioner |
302 |
Valve Positioner |
303 |
Valve Smart Valve Positioner |
304 |
Temperature Differential |
305 |
Analytical Dissolved Oxygen |
306 |
Analytical pH Controller |
307 |
Analytical Conductivity/Resistivity Controller |
308 |
Analytical Conductivity/Resistivity |
309 |
Level Displacement |
310 |
Temperature w/ PID |
311 |
Valve Universal Positioner |
312 |
Level Radar - Reflex |
313 |
Valve Digital Positioner w/ PID |
314 |
Valve Intelligent Positioner |
315 |
Analytical Gas Detector |
316 |
Analytical Infrared Gas Detector |
317 |
Analytical Electrochemical Gas Detector |
318 |
Level Magnostrictive |
319 |
Valve On/Off Valve Controller |
320 |
Level Radar - Pulse |
321 |
Analytical Corrosion |
322 |
Level Continuous Capactive |
323 |
Valve Damper Actuator |
324 |
Valve Electric Damper Actuator |
325 |
Flow Electronic |
326 |
Flow Vortex - Multiparameter Mass |
327 |
Analytical Flame Detector |
328 |
Level Nuclear |
329 |
Analytical Density - Radiometric |
330 |
Level Radiometric |
331 |
Analytical Gas/Steam |
332 |
Level Nucleonic |
333 |
Analytical Blade Consistency |
334 |
Analytical Rotary Consistency |
335 |
FMU860 |
336 |
DT |
337 |
DVC |
338 |
FCX |
339 |
AS800 |
340 |
340T |
341 |
340C |
342 |
344 |
343 |
Siemens Micro K |
344 |
SITRANS L |
345 |
SIPAN PH |
346 |
SITRANS P |
347 |
75SMT |
348 |
UNIDELTA |
349 |
8320 |
350 |
SX5100 |
351 |
TSV175 |
352 |
DMU |
353 |
3780 |
354 |
BM70 |
355 |
8u |
356 |
8.3f |
357 |
Output Status |
358 |
Output Status Byte |
359 |
Uninitialized |
360 |
Normal - one sensor |
361 |
Normal - two sensors |
362 |
Normal - three sensors |
363 |
Shorted |
364 |
Shorted- shorted field wiring. |
365 |
Limited high |
366 |
Limited high- block can not respond to upward movement of value. |
367 |
Open |
368 |
Open- open field wiring. |
369 |
Limited low |
370 |
Limited low- block can not respond to upward movement of target. |
371 |
Initialization done |
372 |
Initialization done- block initialization is complete. |
373 |
Not selected |
374 |
Not selected- target value provided by block was not selected. |
375 |
No path |
376 |
No path- there is no path to the process. |
377 |
Fail |
378 |
Fail- hardware failure. |
379 |
Bad |
380 |
Bad- block is out of service or has bad input. |
381 |
Not from process |
382 |
Not from process- value is not directly affected by any process information. |
383 |
Local override |
384 |
Local override- block has LO mode. |
385 |
Not Cascade Mode |
386 |
Not RCas Mode |
387 |
Not ROut Mode |
388 |
No communication |
389 |
No communication- (NO_COM). |
390 |
uint16_var_blk_char |
391 |
uint32_var_blk_char |
392 |
uint8_var_blk_char |
393 |
int8_var_blk_char |
394 |
new itest redef1 label |