0 |
TZID-C |
1 |
Tag |
2 |
Tag- Text that is associated with the Field Device installation. This text can be used by the user in any way. A recommended use is as a unique label to a plant that correlates to a Field Device label: a plant drawing, or on a Control System. This variable is also used as a type of data link layer address handle. The following specification is mandatory for IBIS application: BUS IDENTIFIER |
3 |
Ident. no |
4 |
Valve ID no. |
5 |
Manufacturer's identification number of the associated valve |
6 |
Description |
7 |
User-definable text stored in the field device.The following specification is mandatory for IBIS application: PLANT IDENTIFIER |
8 |
Message |
9 |
User-definable text stored in the field device.The following specification is mandatory for IBIS applications: TAG IDENTIFIER. Description of tag in plain text |
10 |
Pos. type no. |
11 |
Type number of the positioner |
12 |
Access restricted |
13 |
EEPROM status |
14 |
No error |
15 |
AKL status |
16 |
CALCTAB status |
17 |
Device status |
18 |
ROM error |
19 |
RAM error |
20 |
EPROM error |
21 |
WATCHDOG error |
22 |
Test status |
23 |
Leakage towards actuator |
24 |
Setpoint out of range |
25 |
Pos out of sensor range |
26 |
Controller not active |
27 |
Positioning time out |
28 |
Alarm limit of stroke counter exceeded |
29 |
Alarm limit of travel counter exceeded |
30 |
Device error |
31 |
Alarmmask |
32 |
Invalid selection |
33 |
Code too large |
34 |
Code too small |
35 |
Not enough request data |
36 |
Write protect mode active |
37 |
Config status |
38 |
No initialization |
39 |
Initialized, control parameters only |
40 |
Initialized, valve range only |
41 |
Initialized |
42 |
Auto conf locked |
43 |
rest4 |
44 |
Auto conf status |
45 |
Inactive |
46 |
Auto conf started externally |
47 |
Auto configuration is running |
48 |
Error in auto configuration |
49 |
Auto configuration done |
50 |
Auto configuration started locally |
51 |
Spring action actuator |
52 |
Act turn ctclw |
53 |
Act turn clw |
54 |
Auto conf modes |
55 |
Compl auto conf |
56 |
Control parameter |
57 |
Valve range |
58 |
Zeropoint |
59 |
rest3 |
60 |
rest7 |
61 |
rest8 |
62 |
Local configuration is active |
63 |
IP serial number |
64 |
10d |
65 |
IP module |
66 |
3d |
67 |
Max current for I/P |
68 |
Offset min |
69 |
Sensor range |
70 |
° |
71 |
Min reversion time of I/P |
72 |
msec |
73 |
Sensor type |
74 |
Inductive sensor |
75 |
Hall sensor |
76 |
Potentiometer |
77 |
No user-defined characteristic curve |
78 |
Lever zero position |
79 |
Stop turn clw |
80 |
Stop turn ctclw |
81 |
Warning:round-up-error |
82 |
Error in translation from percent to ADC |
83 |
Error in translation from ADC to FLOAT |
84 |
Error in translation from FLOAT to ADC |
85 |
Lower setpoint not between 4..20mA |
86 |
Upper setpoint not between 4..20mA |
87 |
Range error |
88 |
Lower current val |
89 |
5.1f |
90 |
Upper current val |
91 |
Code for unit |
92 |
mA |
93 |
Alarm, S1 and S2 |
94 |
AlarmON=act low |
95 |
S1ON=active low |
96 |
S2ON=active low |
97 |
S1ON=act below |
98 |
S2ON=act below |
99 |
Invalid data |
100 |
EEPROM write count |
101 |
5d |
102 |
WATCHDOG count |
103 |
Power down count |
104 |
EEPROM error count |
105 |
Com error count |
106 |
GAP error count |
107 |
Stroke counter |
108 |
Travel counter |
109 |
Limit stroke counter |
110 |
Limit travel counter |
111 |
Hysteresis |
112 |
Config protection flag |
113 |
Transmitted tolerance band has been limited |
114 |
Tolerance band too small |
115 |
Tolerance band too large |
116 |
Tolerance band |
117 |
5.2f |
118 |
Active tolerance band code |
119 |
Variable tolerance band |
120 |
Fixed tolerance band 1 |
121 |
Fixed tolerance band 2 |
122 |
Fixed tolerance band 3 |
123 |
Fixed tolerance band 4 |
124 |
Operating mode local |
125 |
Controlling mode adaptive |
126 |
Controlling mode fixed |
127 |
Manual operation |
128 |
Manual adjustment |
129 |
Auto configuration |
130 |
Options installed |
131 |
Display |
132 |
Analg pos feedback |
133 |
Dig pos feedback |
134 |
FSK-modem |
135 |
Pressure sensor |
136 |
Valve analysis |
137 |
Characteristic curve |
138 |
Linear |
139 |
1:25equal percentage |
140 |
1:50equal percentage |
141 |
25:1equal percentage |
142 |
50:1equal percentage |
143 |
User configurable |
144 |
Valve action |
145 |
Direct |
146 |
Reverse |
147 |
rest |
148 |
rest2 |
149 |
Parameter outside 0-100% |
150 |
Alarm limit 1 |
151 |
Alarm limit 2 |
152 |
Mode control flag |
153 |
Internal mode active |
154 |
External mode active |
155 |
Operating mode |
156 |
Setpoint mode |
157 |
Analog setp mode |
158 |
Digital setp mode |
159 |
Set to min % |
160 |
Set to max % |
161 |
Travel setpoint |
162 |
% ValveRange |
163 |
Min valve range |
164 |
Max valve range |
165 |
Shut off value |
166 |
Shut off value too large |
167 |
Shut off value too small |
168 |
Adjusted speed up |
169 |
Adjusted speed dn |
170 |
Dead band time limit |
171 |
Measured up stroke time |
172 |
Measured down stroke time |
173 |
Travel range min |
174 |
Travel range max |
175 |
Range smaller than 10% of sensor range |
176 |
Range smaller than 10% of valve range |
177 |
Setpoint overflow |
178 |
Leakage to actuator |
179 |
Setpt out of range |
180 |
Pos out of range |
181 |
Ctrl inactive |
182 |
Pos time out |
183 |
StrokeCtrExceeded |
184 |
TravelCtrExceeded |
185 |
Output min |
186 |
Output max |
187 |
Output action |
188 |
Alarm message |
189 |
>20mA |
190 |
<4mA |
191 |
min>max |
192 |
Range lower than 10% |
193 |
kpUp |
194 |
kpDn |
195 |
tvUp |
196 |
tvDn |
197 |
Go pulse up |
198 |
Go pulse dn |
199 |
ADC noise |
200 |
Offset max |
201 |
IP type |
202 |
Fail safe / single acting |
203 |
Fail freeze / single acting |
204 |
Fail safe / double acting |
205 |
Fail freeze / double acting |
206 |
Max up stroke time |
207 |
Max down stroke time |
208 |
Offset up |
209 |
3.0f |
210 |
Offset down |
211 |
Simulation |
212 |
Active |
213 |
Position |
214 |
Failure |
215 |
Fail analg feedback |
216 |
Alarm msg active |
217 |
AlarmLimit1 active |
218 |
AlarmLimit2 active |
219 |
Measuring task |
220 |
Reset counters |
221 |
Digital input |
222 |
None |
223 |
Move to pos 0% |
224 |
Move to pos 100% |
225 |
Hold position |
226 |
Lock local conf |
227 |
Lock local operation |
228 |
Lock all |
229 |
Actuator |
230 |
Rotary |
231 |
Current of analog position feedback |
232 |
Current input signal in mA, used as command variable in auto mode |
233 |
Controlled variable (actual value) in % in reference to range of travel range |
234 |
Prim var units |
235 |
-- |
236 |
Signal of analog position feedback in % |
237 |
Setpoint |
238 |
Command variable (setpoint value) in % with consideration of command variable range |
239 |
Setpoint units |
240 |
Temperature |
241 |
5.0f |
242 |
Temp unit |
243 |
°C |
244 |
Difference |
245 |
Deviation from setpoint in % |
246 |
Unit of Deviation from setpoint |
247 |
- |
248 |
Diagnostics |
249 |
Digital setpoint |
250 |
Settings |
251 |
Travel range |
252 |
Alarm limits |
253 |
Adjusted speed |
254 |
TZID-C parameter |
255 |
HART |
256 |
HOTKEY_MENU |
257 |
Information |
258 |
Valve parameters |
259 |
Manual |
260 |
Messages |
261 |
Device Tag |
262 |
Options |
263 |
Control parameters |
264 |
Auto configuration |
265 |
Online |
266 |
Setpoint range |
267 |
Serve/Watch |
268 |
General messages |
269 |
Alarms |
270 |
Master reset |
271 |
Write protect off |
272 |
cancelAKL |
273 |
Start auto conf |
274 |
s21 |
275 |
swp4 |
276 |
ADSM |
277 |
FMU860 |
278 |
DT |
279 |
DVC |
280 |
FCX |
281 |
AS800 |
282 |
340T |
283 |
340C |
284 |
344 |
285 |
Siemens Micro K |
286 |
SITRANS L |
287 |
SIPAN PH |
288 |
SITRANS P |
289 |
75SMT |
290 |
UNIDELTA |
291 |
8320 |
292 |
SX5100 |
293 |
TSV175 |
294 |
DMU |
295 |
3780 |
296 |
BM70 |
297 |
8u |
298 |
Simulation inactive |
299 |
|
300 |
Select simulation mode |
301 |
Alarm limit 1 active |
302 |
Alarm limit 2 active |
303 |
No messages |
304 |
Digital input active |
305 |
S1ON=active if falls below limit |
306 |
S1ON=active if exceeds limit |
307 |
S2ON=active if falls below limit |
308 |
S2ON=active if exceeds limit |
309 |
No alarms |
310 |
Really reset? |
311 |
WRITE-PROTECT-MODE IS NOT VALID FOR 100 SECONDS. |
312 |
Auto configuration cancelled |
313 |
Auto configuration not possible, locked! |
314 |
Invalid setpoint mode for this function |
315 |
Set ext setpoint |