0 |
ABB |
1 |
EEPROM 1 error |
2 |
EEPROM 2 error |
3 |
Stat Pres ool |
4 |
Sens Temp ool |
5 |
Elec Temp ool |
6 |
ASIC Update fail |
7 |
ASIC Counter ool |
8 |
EEPROM 1/2 error |
9 |
Field Device Primary Variable Unit - Engineering unit that the Digital Value, Upper Range Value and Lower Range value will be displayed with. |
10 |
inH2O @20DegC |
11 |
inHg @0DegC |
12 |
feet H2O @20DegC |
13 |
mmH2O @20DegC |
14 |
mmHg @0DegC |
15 |
torr @0DegC |
16 |
Transfer Function - Defines the transformation function that will be applied between the Field Device Variable and the respective assigned Analog Output. The transfer function does not affect the Digital Value. |
17 |
Up-Down Scale mode - Defines the setting of the current output when fatal errors are detected. |
18 |
Up-Down Scale mode |
19 |
Field Device Primary Variable Value - Represents the input pressure. |
20 |
.3f |
21 |
.2f |
22 |
.1f |
23 |
Sensor Limit Units and Minimum Span Units - Engineering units that the Upper Sensor Limit, Lower Sensor Limit and Minimum Span will be displayed with. |
24 |
Sensor Limits Units |
25 |
Meter Installation - Defines whether there is a meter installed or not and, if integral, what information the meter will display. |
26 |
Push Buttons - Indicates whether the instrument is fitted with Zero and/or Span calibration buttons. |
27 |
Push Buttons |
28 |
No Push Buttons |
29 |
Zero Pushbutton only |
30 |
Zero & Span Pushbut. |
31 |
Module Type - Defines the Module type of the field instrument. |
32 |
KSA |
33 |
KSB |
34 |
KSC |
35 |
KSD |
36 |
KSK |
37 |
KSM |
38 |
KSN |
39 |
KSP |
40 |
KSR |
41 |
KSV |
42 |
KSG |
43 |
KSS |
44 |
KGF |
45 |
Flange Mount Type - Defines the Flange Mount type of the field instrument. |
46 |
Flange Mount Type |
47 |
DN100 PN25/40 |
48 |
DN100 PN16 |
49 |
DN80 PN16 |
50 |
DN50 PN25/40 |
51 |
DN50 PN64 |
52 |
DN80 PN64 |
53 |
DN50 PN100 |
54 |
DN80 PN100 |
55 |
DN50 PN160 |
56 |
DN80 PN160 |
57 |
2in 300lb |
58 |
2in 400/600lb |
59 |
3in 400/600lb |
60 |
2in 900lb |
61 |
3in 900lb |
62 |
1/2in NPT-F |
63 |
DN80 Table F |
64 |
DN80 Table J |
65 |
DN100 Table F |
66 |
DN100 Table J |
67 |
DN50 PN25 |
68 |
DN25 PN400 |
69 |
DN40 PN40 |
70 |
DIN 11851 |
71 |
Flange Type - Hardware, adjacent to the sensor, that physically connects the process to the sensor. |
72 |
Flange Mount Material - Indicates the construction material of the remote seal flange/s. |
73 |
Flange Mount Material |
74 |
Flange Material - Indicates the material of the flange. |
75 |
17-4-PH |
76 |
Oring Material - Indicates the construction material of a seal that exists between the module and the flange. |
77 |
Nuts and Bolts - Indicates the material of Nuts and Bolts. |
78 |
Nuts and Bolts |
79 |
Alloy Steel |
80 |
Drain Vent Material - Indicates the material of the vents. |
81 |
AISI 303 SS |
82 |
Remote Seal Isolator Material - Defines the material of the remote seal wetted diaphragm. |
83 |
Hastelloy C276 |
84 |
Module Isolator Material - Indicates the material of the sensor diaphragm. |
85 |
SAF 2205 |
86 |
SAF 2304 |
87 |
Block and Trunks material - Indicates the material of the manifold or of the integral orifice trunks. |
88 |
Block & Trunks mtl |
89 |
Orifice Material - Indicates the orifice material. |
90 |
Orifice material |
91 |
Remote Seal Type - Defines the type of Remote seal. |
92 |
TYPE 980.10 |
93 |
Inline |
94 |
Remote Seal Fill Fluid - Defines the remote seal filling liquid. |
95 |
Vegetable oil |
96 |
Glyceryn |
97 |
Number of Remote Seals - Physical quantity of the seals for the remote seal that is installed. |
98 |
Sensor Fill Fluid - Fluid material in the module. |
99 |
Module range - This is the range for the sensor. |
100 |
1.25 kPa |
101 |
2.0 kPa |
102 |
7.0 kPa |
103 |
28 kPa |
104 |
70 kPa |
105 |
150 kPa |
106 |
800 kPa |
107 |
3000 kPa |
108 |
1600 kPa |
109 |
8000 kPa |
110 |
40000 kPa |
111 |
14000 kPa |
112 |
42000 kPa |
113 |
250 kPa |
114 |
600 kPa |
115 |
2500 kPa |
116 |
4000 kPa |
117 |
6000 kPa |
118 |
16000 kPa |
119 |
Calibration Type - Indicates if std. or specific on operating pressure or temperature or both. |
120 |
Procedure Type - It is the type of any special procedure required for the manufacture of the sensor, e.g. degreasing. |
121 |
Procedure Type |
122 |
Oxygen Cleaning |
123 |
Chlorine Cleaning |
124 |
Hydrogen Preparation |
125 |
Special Degreasing |
126 |
Orifice Internal Diameter - Specifies the internal diameter of the integral orifice. |
127 |
Orifice int diam |
128 |
0.5 mm |
129 |
0.8 mm |
130 |
0.9 mm |
131 |
1.3 mm |
132 |
1.6 mm |
133 |
2.1 mm |
134 |
2.8 mm |
135 |
3.5 mm |
136 |
5.0 mm |
137 |
Manifold or Integral Orifice - Specifies whether the field instrument is fitted with a manifold or an orifice. |
138 |
Manif/intg orifice |
139 |
3V Manf Direct |
140 |
3V Manf with Adaptor |
141 |
Internal Orifice |
142 |
Int Orif+Valve Manf |
143 |
External Orifice |
144 |
Ext Orif+Valve Manf |
145 |
Special Transfer Function. |
146 |
Special Transfer Function |
147 |
Lower Sensor Trim Point - Applied process pressure at which the last low sensor trim was performed. Pressure Sensor - Pressure hardware that measures pressure with respect to some reference pressure. |
148 |
Upper Sensor Trim Point - Applied process pressure at which the last upper sensor trim was performed. Pressure Sensor - Pressure hardware that measures pressure with respect to some reference pressure. |
149 |
Sensor trim units - It is the unit of the sensor trim points. |
150 |
Sensor trim units |
151 |
Maximum Working Pressure - Indicates the maximum pressure to which the transmitter can be submitted without causing danger and damage. |
152 |
Maximum Working Pressure Unit - The unit of the Maximum working pressure. |
153 |
Analog Output value - Indicates the current output of the field instrument. |
154 |
Analog Output |
155 |
Percent of Range - Digital value that is proportional to the range defined by the Lower Range Value and the Upper Range Value. The units of this variable is always in percent. |
156 |
% |
157 |
Upper Sensor Limit - Value that defines the absolute upper endpoint (largest magnitude) for the digital value. Pressure - Pressure of the process measured with respect to some reference pressure. |
158 |
Lower Sensor Limit - Value that defines the absolute lower endpoint (smallest magnitude) for the digital value. Pressure - Pressure of the process measured with respect to some reference pressure. |
159 |
Upper Range - Defines the operational endpoint from which the Analog Value and the Percent of Range are derived. In addition, the range values define the points at which the 'analog output saturated' warning is set. |
160 |
Lower Range - Defines the operational endpoint from which the Analog Value and the Percent of Range are derived. In addition, the range values define the points at which the 'analog output saturated' warning is set. |
161 |
Damping Value - Damping time constant applied to both the Digital Value and Analog Value of the respective output. The Unit of this variable are always in seconds. |
162 |
2.2f |
163 |
5.2f |
164 |
Tertiary variable Static Pressure Value. |
165 |
Static Pres |
166 |
Tertiary variable Static Pressure Unit. |
167 |
Sta pres unit |
168 |
MPa |
169 |
Static Pressure trim point - The pressure at which static trim is to take place. |
170 |
Stat Pres trim pt |
171 |
Static Pressure Trim Unit - Units of the static pressure trim point. |
172 |
Stat Pres trim unit |
173 |
Secondary variable Sensor Temperature Value - The displayed temperature is not the process temperature, it is the temperature in the sensor's core. |
174 |
Snsr temp |
175 |
Secondary variable Sensor Temperature Unit. |
176 |
Snsr temp unit |
177 |
Fourth Variable - Temperature of the electronics. |
178 |
Elec temp |
179 |
Fourth Variable Electronic Temperature Unit. |
180 |
Product Code - Specifies the transmitter's code number. |
181 |
Product code |
182 |
Separator &/or Services - Indicates the code of remote seal or code for special services or calibration. |
183 |
Sepratr&/Service |
184 |
Manifold or Orifice - Indicates the code of manifold or integral orifice. |
185 |
Manf or orifice |
186 |
Minimum Span value - Indicates the minimum allowable value for the span. The span is the algebraic difference between the Upper and Lower Range Value. |
187 |
Min span |
188 |
Sensor Serial Number - Indicates the sensor module serial number. |
189 |
7d |
190 |
Up Down Scale Mode |
191 |
This is the array for the dynamic variables |
192 |
Field Device Dynamic variables array |
193 |
|
194 |
Type Code Mismatch |
195 |
Type code mismatch |
196 |
Excess Correction Attempted |
197 |
Configure |
198 |
Zero/Span cal |
199 |
Status |
200 |
Pres sensor trim |
201 |
Sensor trim points |
202 |
Sensor |
203 |
Pres sensor |
204 |
Pres sensor info |
205 |
Temp sensor |
206 |
Stat sensor |
207 |
Pres input scaling |
208 |
Display Limits |
209 |
Product codes |
210 |
Material Info |
211 |
Revision #'s |
212 |
Misc Info |
213 |
write_variables |
214 |
Offline |
215 |
Danger for max working pressure |
216 |
Back to normal |
217 |
Full trim method - The full trimming allows the performance of high or low trim. |
218 |
Full trim |
219 |
Static trim method - The static trimming allows a single point trim of Static Pressure |
220 |
Static trim |
221 |
Rerange 4-20mA |
222 |
Perform a device rerange to 4 - 20mA by applying source pressure input. |
223 |
Before up down scale |
224 |
Before polling |
225 |
Loop in manual |
226 |
Commands the DPK pressure electronics to perform a selftest. |
227 |
FMU860 |
228 |
DT |
229 |
DVC |
230 |
FCX |
231 |
AS800 |
232 |
340T |
233 |
340C |
234 |
344 |
235 |
Siemens Micro K |
236 |
SITRANS L |
237 |
SIPAN PH |
238 |
SITRANS P |
239 |
75SMT |
240 |
UNIDELTA |
241 |
8320 |
242 |
SX5100 |
243 |
TSV175 |
244 |
DMU |
245 |
3780 |
246 |
BM70 |
247 |
8u |
248 |
low |
249 |
high |
250 |
Field Device Variable Unit- Engineering unit to be displayed with the Digital Value representation, Minimum Span, Upper Range Value, Lower Range Value, Lower Sensor Limit, and Upper Sensor Limit. Pressure- Pressure of the process measured with respect to a reference pressure. |
251 |
Send warning |
252 |
Send Warning- Yields a units code notice to the User. |
253 |
Variables which use this as the units code will be in the previous units until this value is sent to the device. |
254 |
DANGER: Change of this value affects plant and personnel safety. MUST be done by qualified personnel only. |
255 |
Note: Loop may be returned to automatic control when SEND is done |
256 |
Applied values read:
PV: %{1}
Units: %{0} |
257 |
Applied zero reads:
PV: %{1}
Units: %{0} |
258 |
Last Input val used:
Units: %{0}
Hival: %{2}
Loval: %{1} |
259 |
Select choice: |
260 |
High Trim;Low Trim;Display limits;Exit |
261 |
Apply a Hival Pres. Higher than Loval |
262 |
Pressure stabilizing. PLEASE WAIT... |
263 |
Units: %{0}
Pres. applied: %{1} |
264 |
Enter applied Hival: |
265 |
Aborting procedure due to last error |
266 |
Apply a Loval Pres. Lower than Hival |
267 |
Enter applied Loval: |
268 |
SENSOR LIMITS:
Units:%{0}
USL: %{2}
LSL: %{1} |
269 |
Static value read
stat value: %{0}
units: %{1} |
270 |
Modify;Ready |
271 |
Enter static value: |
272 |
Now Apply input pressure
(URV is %{0})
(LRV is %{1}) |
273 |
Current process value: %{0} %{1} |
274 |
Read new value;Set as 4mA value;Set as 20mA value;Exit |
275 |
WARN: Up/Down scale mode affects the TX behaviour in case of fault: the failsafe condition should be set. |
276 |
WARN: TX with polling address different from 0 cannot be part of a control loop. |
277 |
Executing selftest. PLEASE WAIT... |
278 |
Self test terminated |