0 |
50XM1000 |
1 |
50SM1000 |
2 |
50XM2000 |
3 |
10VT1000 |
4 |
50VM1000 |
5 |
D10A5480 |
6 |
Error register 1 |
7 |
Urefn too big |
8 |
Excitation |
9 |
MAX alarm |
10 |
MIN alarm |
11 |
Primary |
12 |
Function test |
13 |
Totalizer >F |
14 |
Totalizer <R |
15 |
Error register 2 |
16 |
Detec.e.pipe |
17 |
A/D saturated |
18 |
Uref too small |
19 |
Flow > 130% |
20 |
Zero return |
21 |
EEPROM data |
22 |
Totalizer |
23 |
Urefp too big |
24 |
Error register 3 |
25 |
Adjust System zero |
26 |
Error: System zero |
27 |
.3f |
28 |
8.3f |
29 |
Range unit |
30 |
spcl/s |
31 |
programable unit per second |
32 |
spcl/min |
33 |
programable unit per minute |
34 |
spcl/h |
35 |
programable unit per hour |
36 |
spcl/day |
37 |
programable unit per day |
38 |
Totalizer Unit |
39 |
spcl |
40 |
programable unit |
41 |
Flow Sensor- Hardware that measures flow rate. |
42 |
Gross Total- Non-resettable totalizer. |
43 |
Reverse Total- Non-resettable reverse totalizer. |
44 |
4th |
45 |
Status |
46 |
Sensor |
47 |
Sensor info |
48 |
Sensor config |
49 |
Detector e.pipe |
50 |
Reset Totalizer |
51 |
Pulse output |
52 |
Input |
53 |
Signal processing |
54 |
Output |
55 |
Alarm |
56 |
Current |
57 |
Display |
58 |
Units |
59 |
Special Unit |
60 |
Service |
61 |
Primary adjust |
62 |
Primary data |
63 |
Secondary adjust |
64 |
Range parameters |
65 |
Device Info |
66 |
Language |
67 |
Select german, english, french or spanish for the output on the display of the secondary. |
68 |
German |
69 |
English |
70 |
French |
71 |
Spanish |
72 |
Meter size |
73 |
actual meter size of the primary, selectable only if RANGE DN is set to FIXED. |
74 |
1 mm 1/25 in |
75 |
1.5 mm 1/17 in |
76 |
2 mm 1/12 in |
77 |
3 mm 1/8 in |
78 |
4 mm 5/32 in |
79 |
5 mm 3/16 in |
80 |
6 mm 1/4 in |
81 |
8 mm 5/16 in |
82 |
10 mm 3/8 in |
83 |
15 mm 1/2 in |
84 |
20 mm 3/4 in |
85 |
25 mm 1 in |
86 |
32 mm 1-1/4 in |
87 |
40 mm 1-1/2 in |
88 |
50 mm 2 in |
89 |
65 mm 2-1/2 in |
90 |
80 mm 3 in |
91 |
100 mm 4 in |
92 |
125 mm 5 in |
93 |
150 mm 6 in |
94 |
200 mm 8 in |
95 |
250 mm 10 in |
96 |
300 mm 12 in |
97 |
350 mm 14 in |
98 |
400 mm 16 in |
99 |
450 mm 18 in |
100 |
500 mm 20 in |
101 |
600 mm 24 in |
102 |
700 mm 27 in |
103 |
750 mm 30 in |
104 |
800 mm 33 in |
105 |
900 mm 36 in |
106 |
1000 mm 39 in |
107 |
1100 mm 42 in |
108 |
1200 mm 48 in |
109 |
1300 mm 51 in |
110 |
1350 mm 53 in |
111 |
1400 mm 54 in |
112 |
1500 mm 60 in |
113 |
1600 mm 64 in |
114 |
1700 mm 66 in |
115 |
1800 mm 72 in |
116 |
2000 mm 78 in |
117 |
2100 mm 82 in |
118 |
2200 mm 86 in |
119 |
2300 mm 90 in |
120 |
2400 mm 94 in |
121 |
Filter |
122 |
Select Filter on, if the output signal is noisy or for pulsating flows (pulsation free output). |
123 |
off |
124 |
on |
125 |
Prog unit |
126 |
select with density if the programable unit is massflowand without density if it is volumeflow. |
127 |
without density |
128 |
with density |
129 |
Function P1/P2 |
130 |
on operating mode 2 RANGE,AUTOMATIC terminal P1/P2 signals the flow range. On the other operating modes all other functions are available. |
131 |
No Funktion |
132 |
F/R-Signal |
133 |
Empty pipe open |
134 |
Empty pipe closed |
135 |
General alarm open |
136 |
General alarm closed |
137 |
MAX/MIN alarm open |
138 |
MAX/MIN alarm closed |
139 |
MIN alarm open |
140 |
MIN alarm closed |
141 |
MAX alarm open |
142 |
MAX alarm closed |
143 |
Range |
144 |
Function X1 |
145 |
on operating mode 2 RANGE,EXTERN terminal X1 selets the flow range. If the contact is open range 1 is selected, if it is closed range 2 is selected. On the other operating modes the other functions are available. |
146 |
Totalizer reset |
147 |
ext. range 2 |
148 |
Iout at Alarm |
149 |
Select HIGH or LOW current output for error conditions. |
150 |
130 % |
151 |
0 % |
152 |
select ON if the detector e.pipe shall signals an empty pipe. |
153 |
Alarm empty pipe |
154 |
If set to ON an empty pipe is signaled with the combined output signal. If set to off no contact output signal will be set. |
155 |
Iout at empty pipe |
156 |
Select HIGH or LOW current output on empty pipe. |
157 |
Totalizer funct. |
158 |
If STANDARD is selected the count pulses for forward and reverse flow directions are integrated separately in two different counters. On DIFFER.TOTAL only a single difference totalizer is utilized for both flow directions. On forward flow the totalizer is incremented, on reverse flow he is decremented. |
159 |
standard |
160 |
differ. total |
161 |
1st line |
162 |
The process display for the 1st line of the secondary. |
163 |
Q [Bargraph] |
164 |
Q [mA] |
165 |
Q [unit] |
166 |
Q [%] |
167 |
Detector e.P. |
168 |
Signal p/n |
169 |
Reference p/n |
170 |
Signal, Ref. |
171 |
Blanks |
172 |
TAG number |
173 |
Mains Freqency |
174 |
2nd line |
175 |
The process display for the 2nd line of the secondary. |
176 |
1st line multipl. |
177 |
The multiplex mode for the 1st line of the secondary. |
178 |
2nd line multipl. |
179 |
The multiplex mode for the 2nd line of the secondary. |
180 |
Operating mode |
181 |
Select STANDARD for continuous flow. Select FAST for piston pump operation and short time fills >3 s. 2 RANGE, AUTOMATIC sets function P1 P2 to RANGE. MIN- and MAX-Alarm always refer to range 1. 2 RANGE, EXTERN sets function X1 to EXT.RANGE. MIN- and MAX-Alarm always refer to the selected range. |
182 |
fast |
183 |
2 Range, auto. |
184 |
2 Range, ext. |
185 |
Flowdirection |
186 |
flowdirection is selected in forward and reverse flow or forward flow only. |
187 |
forward |
188 |
forward/reverse |
189 |
Flowindication |
190 |
Reverses the flow direction designations. |
191 |
opposite |
192 |
Module |
193 |
Selects the hardware module placed in the secondary |
194 |
none |
195 |
Range velocity |
196 |
Selects range velocity in m/s or ft/s. |
197 |
10 m/s |
198 |
33.33 ft/s |
199 |
range<.05rangeDN |
200 |
Ability to select upper range value less than .05 rangeDN. |
201 |
range DN |
202 |
Range DN set to FIXED allows the selection of METER SIZE from the implemented list. Range DN set to programable allows direct input to Range DN, metersize is not selectable. |
203 |
fixed |
204 |
programable |
205 |
Debit excitation |
206 |
debit excitation |
207 |
6.25 Hz AC/DC |
208 |
7.5 Hz AC/DC |
209 |
12.5 Hz AC/DC |
210 |
15 Hz AC/DC |
211 |
25 Hz AC/DC |
212 |
30 Hz AC/DC |
213 |
6.25 Hz DC |
214 |
7.5 Hz DC |
215 |
12.5 Hz DC |
216 |
15 Hz DC |
217 |
25 Hz DC |
218 |
30 Hz DC |
219 |
negativ |
220 |
positiv |
221 |
excitation |
222 |
6.25 Hz AC |
223 |
7.5 Hz AC |
224 |
12.5 Hz AC |
225 |
15 Hz AC |
226 |
25 Hz AC |
227 |
30 Hz AC |
228 |
Analog range |
229 |
analog range |
230 |
V=1 man. |
231 |
V=2 man. |
232 |
V=4 man. |
233 |
V=8 man. |
234 |
V=1 auto. |
235 |
V=2 auto. |
236 |
V=4 auto. |
237 |
V=8 auto. |
238 |
Preamplifier |
239 |
preamplifier |
240 |
yes |
241 |
no |
242 |
Collection char variables |
243 |
char variables |
244 |
MAX alarm from 0% to 130%. |
245 |
3d |
246 |
MIN alarm from 0% to 130%. |
247 |
Overflow >F |
248 |
overflow >F is incremented every 10,000,000 selected units. |
249 |
5d |
250 |
Overflow <R |
251 |
overflow <R is incremented every 10,000,000 selected units. |
252 |
Mains interrupt |
253 |
mains interrupt |
254 |
Code number |
255 |
code number |
256 |
Calibration mode |
257 |
calibration mode |
258 |
col ui_var |
259 |
help ui variables |
260 |
|
261 |
Range 2 |
262 |
Only valid if operating mode is set to 2 FLOW RANGE. Range 2 from 0.05*Range DN to upper range value. |
263 |
Pulse factor |
264 |
pulse factor from 0.001 to 1000 per selected unit. Max. count frequency is 5 kHz. Depends on the the selected pulse width and will be automaticly corrected. |
265 |
.4f |
266 |
9.4f |
267 |
Pulse width |
268 |
pulse width from 0.1 to 2000 ms. Depends on the the selected pulse factor and will be automaticly corrected. |
269 |
ms |
270 |
Low flow cutoff |
271 |
Low flow cutoff from 0 to 10% of the selected flow upper range value. |
272 |
8.4f |
273 |
Density |
274 |
Density in the range from 0.01 to 5 g/cm3 for mass flow. |
275 |
System zero |
276 |
system zero from -50 to 50 Hz |
277 |
Unit factor |
278 |
unit factor for the special unit based on liters. |
279 |
.5f |
280 |
8.5f |
281 |
Threshold |
282 |
threshold empty pipe |
283 |
.1f |
284 |
6.1f |
285 |
Span adjust >F |
286 |
span adjust >F |
287 |
Span adjust <R |
288 |
span adjust <R |
289 |
Zero adjust |
290 |
zero adjust |
291 |
Adjust Iout 4mA |
292 |
adjust Iout 4mA |
293 |
Adjust Iout 20mA |
294 |
adjust Iout 20mA |
295 |
Calibration |
296 |
calibration |
297 |
.2f |
298 |
8.2f |
299 |
Span Cs 6.25 Hz |
300 |
span Cs 6.25 Hz |
301 |
Zero Cz 6.25 Hz |
302 |
zero Cz 6.25 Hz |
303 |
Span Cs 12.5 Hz |
304 |
span Cs 12.5 Hz |
305 |
Zero Cz 12.5 Hz |
306 |
zero Cz 12.5 Hz |
307 |
Span Cs 25 Hz |
308 |
span Cs 25 Hz |
309 |
Zero Cz 25 Hz |
310 |
zero Cz 25 Hz |
311 |
freq. emp.pipe |
312 |
frequency measured by detector empty pipe |
313 |
.f |
314 |
Collection float variables |
315 |
Help float variables |
316 |
Reset Total. >F |
317 |
Reset Total. <R |
318 |
Reset Overflow >V |
319 |
Reset Overflow <R |
320 |
Name special unit |
321 |
Name of the special unit (4 byte ASCII) |
322 |
device busy |
323 |
Auto adj. sys.zero |
324 |
Load Primary Data |
325 |
Error EEPROM or Error ext.EEPROM |
326 |
Converter in XM1000-Mode |
327 |
Store Primary Data |
328 |
Error EEPROM |
329 |
FMU860 |
330 |
DT |
331 |
DVC |
332 |
FCX |
333 |
AS800 |
334 |
340T |
335 |
340C |
336 |
344 |
337 |
Siemens Micro K |
338 |
SITRANS L |
339 |
SIPAN PH |
340 |
SITRANS P |
341 |
75SMT |
342 |
UNIDELTA |
343 |
8320 |
344 |
SX5100 |
345 |
TSV175 |
346 |
DMU |
347 |
3780 |
348 |
BM70 |
349 |
8u |
350 |
6.2f |
351 |
7d |
352 |
4.2f |
353 |
Pulse Output Unit- Engineering units that the frequency andtotalizer outputs will be displayed with. |
354 |
Gross Total Value- Non-resettable totalizer value. Counts frequency output pulses while total control is turned on. This value will be reset to 0 when the pulse scaling, line size, or units are changed. |
355 |
Reverse Total Value- Non-resettable totalizer value. Counts frequency output pulses while total control is turned on and flow is in the reverse direction. This value will be reset to 0 when the pulse scaling, line size, or units are changed. |
356 |
Pulse output units- Engineering units that the frequency and totalizer outputs will be displayed with |
357 |
Gross Total Value- Counts frequency output pulses while total control is turned on. This value will be reset to 0 when the pulse scaling, line size, or units are changed |
358 |
Reverse Total Value- Counts frequency output pulses while total control is turned on and flow is in the reverse direction. This value will be reset to 0 when the pulse scaling, line size, or units are changed |
359 |
Pulse output- scaled frequency output from 0-1000 Hz, linear with input. |
360 |
Net Total Value- Resettable totalizer. |
361 |
Really reset totalizer forward ? |
362 |
Really reset totalizer reverse ? |
363 |
Really reset overflow counter totalizer forward ? |
364 |
Really reset overflow counter totalizer reverse ? |
365 |
Really start automatic adjust system zero ? |
366 |
automatic adjust system zero has been started
* Please wait * |
367 |
Error system zero |
368 |
adjust system zero ok
new value:
%{0} |
369 |
Really load primary data ? |
370 |
Really store primary data ? |