0 |
50XM1000 |
1 |
Flow Sensor- Hardware that measures flow rate. |
2 |
totalizer |
3 |
Totalizer forward/reverse - resettable |
4 |
data_link_or_pulse_output |
5 |
detector empty pipe |
6 |
new parameter from keypad |
7 |
low-flow cut-off |
8 |
error detected |
9 |
clear totalizer forward |
10 |
clear totalizer reverse |
11 |
flow direction changed |
12 |
detector empty pipe on/off |
13 |
flow indication |
14 |
calibration factor programable |
15 |
muliplex display is on/off |
16 |
mode is forward/reverse or forward only |
17 |
speed is 10 m/s or 33.33 ft/s |
18 |
noise reduction is on/off |
19 |
current output on alarm |
20 |
display flow |
21 |
ad-converter saturated positiv |
22 |
Uref too small |
23 |
flow greater than 130 % |
24 |
zero return |
25 |
NVRAM defect |
26 |
ad-converter saturated negativ |
27 |
Uref positiv too large |
28 |
Uref negativ too large |
29 |
error excitation |
30 |
mains failure |
31 |
Invalid number of bytes |
32 |
Parameter |
33 |
.2f |
34 |
4.2f |
35 |
.3f |
36 |
7.3f |
37 |
Totalizer |
38 |
Totalizer forward and reverse flow |
39 |
>F |
40 |
<R |
41 |
Total.forw. |
42 |
Totalizer forward flow |
43 |
Total.rev. |
44 |
Totalizer reverse flow |
45 |
Totalizer units |
46 |
Reset totalizer |
47 |
Reset totalizer forward or reverse |
48 |
forward |
49 |
reverse |
50 |
% |
51 |
s |
52 |
Hz |
53 |
mA |
54 |
Totalizer forward Value- Resettable totalizer value. |
55 |
Totalizer reverse Value- Resettable totalizer value. |
56 |
Overflow >F |
57 |
Overflow forward Value - Resettable value. |
58 |
3d |
59 |
Overflow <R |
60 |
Overflow reverse Value - Resettable value. |
61 |
overflow counter forward and reverse |
62 |
Overflow counter forward |
63 |
is incremented every 10,000,000 totalizer units |
64 |
Overflow counter reverse |
65 |
transmitter variables accessed via command 33 |
66 |
damping |
67 |
damping value - 0.1 to 99.9 seconds |
68 |
low flow cutoff |
69 |
cutoff value - 0 to 10 % |
70 |
pulse width value |
71 |
pulse width - 0.032 to 2000 ms |
72 |
span forward flow |
73 |
span forward flow - units of percent |
74 |
span reverse flow |
75 |
span reverse flow - units of percent |
76 |
system zero |
77 |
system zero - -1500 to 1500 Hz |
78 |
Damping |
79 |
|
80 |
Low flow cutoff |
81 |
low_flow cutoff |
82 |
Pulse width |
83 |
ms |
84 |
Pulse Width- Width of the frequency output pulse on frequency output number 'X'. |
85 |
Pulse factor >F |
86 |
Pulse factor <R |
87 |
Span adjust >F |
88 |
Span adjust <R |
89 |
System zero adjust |
90 |
.4f |
91 |
Zero adjust |
92 |
Range |
93 |
Lower Range |
94 |
Range DN |
95 |
current |
96 |
% range |
97 |
%range |
98 |
Filter |
99 |
to get a better process value, if the signal is noisy. |
100 |
off |
101 |
on |
102 |
Detector e.pipe |
103 |
Turns the detector empty pipe off or on |
104 |
Flow mode |
105 |
Flow is measured in forward and reverse or forward only direction |
106 |
forward/reverse |
107 |
forward |
108 |
Metersize |
109 |
Diameter of the tube in units of mm and inch |
110 |
1 mm 1/25 in |
111 |
1.5 mm 1/17 in |
112 |
2 mm 1/12 in |
113 |
3 mm 1/10 in |
114 |
4 mm 5/32 in |
115 |
5 mm 3/16 in |
116 |
6 mm 1/4 in |
117 |
8 mm 5/16 in |
118 |
10 mm 3/8 in |
119 |
15 mm 1/2 in |
120 |
20 mm 3/4 in |
121 |
25 mm 1 in |
122 |
32 mm 1-1/4 in |
123 |
40 mm 1-1/2 in |
124 |
50 mm 2 in |
125 |
65 mm 2-1/2 in |
126 |
80 mm 3 in |
127 |
100 mm 4 in |
128 |
125 mm 5 in |
129 |
150 mm 6 in |
130 |
200 mm 8 in |
131 |
250 mm 10 in |
132 |
300 mm 12 in |
133 |
350 mm 14 in |
134 |
400 mm 16 in |
135 |
450 mm 18 in |
136 |
500 mm 20 in |
137 |
600 mm 24 in |
138 |
700 mm 28 in |
139 |
750 mm 30 in |
140 |
800 mm 32 in |
141 |
900 mm 36 in |
142 |
1000 mm 40 in |
143 |
1100 mm 42 in |
144 |
1200 mm 48 in |
145 |
1300 mm 51 in |
146 |
1400 mm 54 in |
147 |
1500 mm 60 in |
148 |
1600 mm 64 in |
149 |
1700 mm 66 in |
150 |
1800 mm 72 in |
151 |
2000 mm 78 in |
152 |
2100 mm 82 in |
153 |
2200 mm 86 in |
154 |
2300 mm 90 in |
155 |
2400 mm 94 in |
156 |
Excitation |
157 |
Frequency that the coils operate at. |
158 |
6 1/4 |
159 |
7 1/2 |
160 |
12 1/2 |
161 |
15 |
162 |
Pulse fact. |
163 |
Pulse factor - pulse per totalizer unit. 0.001 - 1000 |
164 |
Threshold |
165 |
Empty pipe threshold. value found by adjusting empty pipe. |
166 |
Flow direction |
167 |
Broadcast |
168 |
Units |
169 |
alarm |
170 |
Communication |
171 |
Empty pipe |
172 |
Totalizer reset |
173 |
RESET |
174 |
Variables |
175 |
Transmitter |
176 |
Transmitter starts again, no change of parameters |
177 |
config.chang.flag |
178 |
configuration changed flag is reseted |
179 |
Initialisation |
180 |
Transmitter is initializied, all parameters are changed to factory settings |
181 |
FMU860 |
182 |
DT |
183 |
DVC |
184 |
FCX |
185 |
AS800 |
186 |
340T |
187 |
340C |
188 |
344 |
189 |
Siemens Micro K |
190 |
SITRANS L |
191 |
SIPAN PH |
192 |
SITRANS P |
193 |
75SMT |
194 |
UNIDELTA |
195 |
8320 |
196 |
SX5100 |
197 |
TSV175 |
198 |
DMU |
199 |
3780 |
200 |
BM70 |
201 |
8u |
202 |
low |
203 |
high |
204 |
tmp_av |
205 |
Pulse output- scaled frequency output from 0-1000 Hz, linear with input. |
206 |
Gross Total- Non-resettable totalizer. |
207 |
Net Total Value- Resettable totalizer. |
208 |
Reverse Total- Non-resettable reverse totalizer. |
209 |
Analog Output |
210 |
Flow Units |
211 |
Device Info |
212 |
Revision #'s |
213 |
Test/Status |
214 |
HART Output |
215 |
Input |
216 |
Status |
217 |
Offline |
218 |
Puls outp config |
219 |
write variables |
220 |
About to enter electronics trim |
221 |
The previous error was seen while trying to initiate electronics trim |
222 |
Waiting for trim to stabilize. |
223 |
Device failure. Device may be stuck in Digital Trim |
224 |
Device failed Digital trim. Device may be out of calibration. |
225 |
The previous error was seen while trying to burn eeprom |
226 |
Digital Trim Passed |
227 |
About to perform xmtr self test |
228 |
Performing self test |
229 |
Aborting method. Device maybe stuck in selftest. |
230 |
Self test passed |
231 |
6.2f |
232 |
7d |
233 |
About to send command 11 |
234 |
about to perform transmitter RESET |
235 |
about to RESET configuration changed flag |
236 |
about to perform transmitter INITIALIZATION, all parameters are changed to factory settings |